광합성과 증발산의 미기상학적 측정기술 (Technique for Estimating $CO_2$ and $H_2O$ Exchange between the Atmosphere and the Biosphere : Eddy Covariance Method)

  • Wonsik Kim
    • 한국농림기상학회:학술대회논문집
    • /
    • 한국농림기상학회 2003년도 춘계 학술발표논문집
    • /
    • pp.115-128
    • /
    • 2003
  • o What is the flux \ulcorner Flux is the transfer of a quantity per unit area per unit time. The quantities are mass, heat, moisture, momentum and pollutant in micrometeorology. Kinematic flux (Fluid). The reduction in wind speed due to frictional drag transfers momentum from the atmosphere to the surface, creating turbulence that mixes the air and transports heat and water from the surface into the lower atmosphere. (omitted)

  • PDF

표면의 대류열전달계수, 방사율 및 화염 열유속 역해석 연구 (Inverse Estimation of Convective Heat Transfer Coefficient, Emissivity and Flame Heat Flux on the Surface)

  • 윤경범;박원희
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.15-20
    • /
    • 2013
  • 반발 입자 군집 최적화 알고리즘을 이용하여 시편 표면에서의 대류열전달 계수, 방사율 및 화염에 의한 열유속을 예측하였다. 콘 칼로리미터를 이용하여 여러 열유속 조건 하에서의 방무목 시편의 표면 온도와 질량감소율 및 발화시간을 측정하였다. 본 연구에서 최적화된 대류열전달계수, 방사율 및 화염에 의한 열유속을 이용하여 계산된 표면온도는 실험결과와 각 열유속에 대하여 평균오차가 2% 내로 잘 일치하였다. 본 연구에서 제시한 방법을 이용하여 실험적 방법으로 직접 측정하기 매우 어려운 화염이 발생하는 표면에서 열전달과 관련된 여러 물리량을 구할 수 있다.

복사열을 이용한 소나무와 굴참나무 낙엽의 연소특성 분석 (A Combustion Characteristic Analysis of Quercus Variabilis and Pinus Densiflora Fallen Leaves Using Radiation Heat Flux)

  • 박형주;김응식;김장환;김동현
    • 한국화재소방학회논문지
    • /
    • 제21권3호
    • /
    • pp.41-46
    • /
    • 2007
  • 본 연구에서는 지표화의 연소물질인 소나무와 굴참나무 낙엽에 대해 일정한 외부 복사열에 의한 연소특성을 분석하였다. 일정한 외부 복사열에 노출된 낙엽의 착화시간, 착화온도, 임계열유속, 질량감소속도를 측정하기 위해 낙엽의 종류별로 5개의 시료를 사용하였으며, 낙엽에 복사열을 노출시키기 위해 Mass loss calorimeter를 사용하였다. 시료 용기의 크기는 $100\;mm{\times}100\;mm{\times}12\;mm$로 소나무와 굴참나무 낙엽을 건조 후 분쇄하여 사용하였다. 연구결과, 소나무 낙엽과 굴참나무 낙엽의 시료에서 외부 복사열이 $9\;kW/m^2$ 미만에서는 착화가 발생하지 않았다. 또한, 연소시간 동안 표면온도 변화는 굴참나무 낙엽에 비해 소나무 낙엽이 더 오랜 시간동안 고온을 유지함을 알 수 있었으며, 최대질량감소속도와 평균질랑감소속도에 있어서는 굴참나무 낙엽이 소나무 낙엽 보다 더 빠르게 진행됨을 알 수 있었다. 향후, 연소특성에 대한 구체적인 연소반응 특성에 대한 실험연구가 필요할 것으로 판단된다.

수평관내 이산화탄소의 냉각열전달과 압력강하 특성에 관한 연구 (Heat transfer and pressure drop characteristics during cooling process of supercritical $CO_2$ in a horizontal tube)

  • 손창효;김종열;노건상;구학근;박기원;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.244-245
    • /
    • 2005
  • This paper presents the heat transfer and pressure drop characteristics during cooling process of carbon dioxide in a horizontal tube. The test section is a tube in tube type heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. It was made of a stainless steel tube with the inner diameter of 7.75 [mm], the outer 2 diameter of 9.53 [mm] and length of 6000 [mm]. The refrigerant mass fluxes were $200{\sim}400$ [kg/$m^2s$] and the average pressure varied from 7.5 [MPa] to 10.0 [MPa]. The main results were summarized as follows The heat transfer coefficient of supercritical $CO_2$ increases in decrease of the gas cooler pressure. And the heat transfer coefficient increases with respect to the increase of the refrigerant mass flux. Among some correlations proposed in a transcritical region, Bringer-Smith's correlation has some analogy with experimental results. The pressure drop decreases in increase of the gas cooler pressure and increases with respect to increase the refrigerant mass flux.

  • PDF

수평관내 이산화탄소의 증발 압력강하 (Evaporation pressure drop of $CO_2$ in a horizontal tube)

  • 이동건;손창효;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.552-559
    • /
    • 2005
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation pressure drop of $CO_2$ are highly dependent on the vapor qualify, heat flux and saturation temperature. The evaporation pressure drop of $CO_2$ is very lower than that of R-22. In comparison with test results and existing correlations. the best fit of the present experimental data is obtained with the correlation of Choi et al. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

An Experimental Study on Dryout Pattern of Two-Phase Flow in Helically Coiled Tubes

  • Chung, Won-Seok;Sa, Young-Cheol;Lee, Joon-Sik
    • Journal of Mechanical Science and Technology
    • /
    • 제16권11호
    • /
    • pp.1540-1549
    • /
    • 2002
  • Experimental results are presented for the effects of coil diameter, system pressure and mass flux on dryout pattern of two-phase flow in helically coiled tubes. Two tubes with coil diameters of 215 and 485 mm are used in the present study, Inlet system pressures range from 0.3 to 0.7 MPa, mass flux from 300 to 500 kg/㎡s, and heat flux from 36 to 80 kw/㎡. A partial dryout region exists because of the geometrical characteristics of the helically coiled tube. The length of the partial dryout region increases with coil diameter and system pressure. On the other hand, it decreases with increasing mass flux. The critical quality at the tube top side increases with mass flux, but decreases with increasing system pressure. This tendency is more notable when the coil diameter is larger. When the centrifugal force effect becomes stronger, dryout starts at the top and bottom sides of the tube. However, when the gravity effect becomes stronger, dryout is delayed at the tube bottom side. In some cases when the mass flux is low, dryout occurs earlier at the outer side than at the inner side of the tube because of film inversion.

증발분출냉각의 열전달 특성에 관한 실험적 연구 (Experimental study on the heat transfer characteristics of evaporative transpiration cooling)

  • 이진호;남궁규완;김홍제;주성백
    • 대한기계학회논문집
    • /
    • 제12권5호
    • /
    • pp.1130-1137
    • /
    • 1988
  • 본 연구에서는 증발분출냉각장치의 설계 및 이의 응용을 위하여 두께가 비교 적 두꺼운(120mm) 다공물질층을 모델로 사용하여 증발분출냉각에 관한 열전달특성을 실험적으로 조사하였다. 실험은 열과 유체의 흐름이 1차원 정상상태에 대하여 증발 영역의 발생과 그 길이 및 상변화위치, 그리고 다공물질층의 표면온도등에 영향을 미 치는 인자들을 조사하며, 아울러 냉각수의 상변화시 다공층내 냉각수 유동의 안정성 여부를 관찰하였다.

Study on the heat and mass transfer in ultrasonic assisting vacuum membrane distillation

  • Guo, Hao;Peng, Changsheng;Ma, Weifang;Yuan, Hetao;Yang, Ke
    • Membrane and Water Treatment
    • /
    • 제8권3호
    • /
    • pp.293-310
    • /
    • 2017
  • An ultrasonic assisting vacuum membrane distillation (VMD) system was designed to promote the heat and mass transfer in membrane distillation (MD) process. Both the effects of operating conditions and ultrasonic parameters to permeation flux in this process were investigated; the heat and mass transfer mechanism was also being discussed in this paper. The results showed that the performance of VMD process was improved significantly by ultrasonic assisting. The permeation flux was boosted at a certain feed solution temperature, pressure at permeate side and feed solution velocity whether or not to PP and PTFE. The results also indicated that ultrasonic power and frequency also was the key factor affecting the mass and transfer efficiencies. The feed side transfer coefficient ($K_f$), corresponding to ultrasonic power ($K_f=4.406-0.026{\times}P+7.824{\times}10^{-5}{\times}P^2$) and ultrasonic frequency ($K_f=0.941+0.598{\times}f-0.012{\times}f^2+6.283{\times}10^{-5}f^3$), was obtained and employed in the modeling of ultrasonic assisting VMD process. The modeling results showed that the calculated value of $K_f$ aligned with experimental results well. Both variations of temperature polarization coefficient (TPC) and concentration polarization coefficient (CPC) were studied based on the obtained data. The results showed that both TPC and CPC were improved obviously by the ultrasonic parameters.

수평평활관내의 비공비 혼합냉매의 응축에 대한 예측모델 (A Prediction Model for Condensation of Zeotropic Refrigerant Mixtures Inside a Horizontal Smooth Tube)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.262-270
    • /
    • 2001
  • This paper deals with a prediction method for the condensation of ternary refrigerant mixture inside a horizontal smooth tube. Based on some reliable assumptions, the governing equations for the local heat and mass transfer characteristics are derived, and the prediction for the condensation of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a, including R407C, is carried out. The local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, mass flux etc. are obtained for a constant wall temperature and a constant wall heat flux conditions, and the effects of the composition of HFC32/HFC125/HFC134a on heat transfer characteristics are examined. The prediction result is also compared with experimental data for condensation of ternary refrigerant mixtures. The predicted wall temperature distribution has a similar trend with experimental data but the predicted local heat transfer coefficients are 20-30% higher than the experimental data.

  • PDF

판형 열교환기에서 맥동유동이 냉매의 증발에 미치는 영향 (Effects of Pulsating Flow on Evaporation of Refrigerant in a Plate Heat Exchanger)

  • 강병하;정일권;김석현
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.627-634
    • /
    • 2006
  • Evaporation heat transfer characteristics by pulsating flow in a plate heat exchanger have been investigated experimentally in this study. R-l34a is evaporated by receiving heat from the hot water in the plate heat exchanger. The pulsating frequency in refrigerant side of the plate heat exchanger is varied in the range of 5-25 Hz. The operating pressure of R-l34a and mass flux of hot water are also varied 0.6-0.9 MPa and $45-105 kg/m^2s$, respectively. The experimental results indicate that evaporation heat transfer coefficient of pulsating flow is improved up to 6.3% compared with that of the steady flow at 10 Hz and $G_w=45 kg/m^2s$. It is also found that the evaporation heat transfer enhancement ratio is decreased with an increase in mass flux of hot water, and the evaporation heat transfer enhancement is little influenced by operating pressure of R-l34a.