• Title/Summary/Keyword: Heat accident

Search Result 341, Processing Time 0.028 seconds

In-depth investigation of natural convection thermal characteristics of BALI experiment through Eulerian computational fluid dynamics code and comparison with Lagrangian code

  • Hyeongi Moon;Sohyun Park;Eungsoo Kim;Jae-Ho Jeong
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.9-18
    • /
    • 2024
  • In-vessel retention through external reactor vessel cooling (IVR-ERVC) is a severe accident management (SAM) strategy that has been adopted and used in many nuclear reactors such as AP1000, APR1400, and light water reactor etc. Some reactor accidents have raised concerns about nuclear reactors among residents, leading to a decrease in residents' acceptability and many studies on SAM are being conducted. Experiments on IVR-ERVC are almost impossible due to its specificity, so fluid characteristics are analyzed through BALI experiments with similar condition. In this study, computational fluid dynamics (CFD) via Reynolds-averaged Navier-Stokes (RANS) and large eddy simulation (LES) for BALI experiments were performed. Steady-state CFD analysis was performed on three turbulence models, and SST k-ω model was in good agreement with the experimental measurement temperature within the maximum error range of 1.9%. LES CFD analysis was performed based on the RANS analysis results and it was confirmed that the temperature and wall heat flux for depth was consistent within an error range of 1.0% with BALI experiment. The LES CFD analysis results were compared with those of the Lagrangian-based solver. LES matched the temperature distribution better than SOPHIA, but SOPHIA calculated the position of boundary between stratified layer and convective layer more accurately. On the other hand, Lagrangian-based solver predicted several small eddy behaviors of the convective layer and LES predicted large vortex behavior. The vibration characteristics near the cooling part of the BALI experimental device were confirmed through Fast Fourier Transform (FFT) investigation. It was found that the power spectral density for pressure at least 10 times higher near the side cooling than near the top cooling.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Deformation Characteristics of Zircaloy-4 Fuel Cladding due to Oxidation in Environment of High Temperature and Steam (고온, 수증기 속에서 산화된 질칼로이-4 핵연료 피복관의 변형 특성에 관한 연구)

  • Jung, Sung-Hoon;Suh, Kyung-Soo;Kim, In-Sup
    • Nuclear Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.218-227
    • /
    • 1986
  • Studies were conducted to determine the extent of oxidation and same of the mechanical property changes of Zircaloy-4 fuel cladding after it was exposed to hot steam environment. The purpose of these tests was to provide some informations on the embrittlement behavior of CANDU type fuel cladding, which could be experienced under the loss-of-coolant accident conditions. The Zircaloy fuel cladding tubes were exposed in a steam environment at the temperature of 90$0^{\circ}C$, 1,00$0^{\circ}C$. The growth of the ZrO$_2$ layer combined with an oxygen rich $\alpha$-phase layer into the Zircaloy tube material was found as a function of time t and temperature of steam exposure, E=1.1√Dt+0.002 where D is a temperature dependent diffusion coefficient. The tensile strength of the specimens exposed for a short period increased but decreased continuously with further exposure. The circumferential elongation was drastically changed with the exposure time while the hoop strength did't decrease greatly. The X-ray measurement of preferred orientation of the Zircaloy tube material indicated that grains in the as received tube were oriented such that the poles of the basal (0001) planes were predominantly radial, while the poles of the basal plane in the tube materials heattreated at 1,00$0^{\circ}C$ were oriented tangentially. It appears that this reoriented texture may contribute to lessening the decrease of the hoop strength of the heat treated Zircaloy tube material.

  • PDF

A Study on the Vent Path Through the Pressurizer Manway and Steam Generator Manway under Loss of Residual Heat Removal System During Mid-loop Operation in PWR (가압경수로의 부분충수 운전중 잔열제거계통 기능 상실사고시 가압기와 증기발생기 Manway 유출유로를 이용한 사고완화에 관한 연구)

  • Y. J. Chung;Kim, W. S.;K. S. Ha;W. P. Chang;K. J. Yoo
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.137-149
    • /
    • 1996
  • The present study is to analyze an integral test, BETHSY test 6.9c, which represent loss of RURS accident under mid-loop operation. Both the pressurizer manway and the steam generator outlet plenum manway are opened as vent paths in order to prevent the system from pressurization by removing the steam generated in the core. The main purposes are to gain insights into the physical phenomena and identify sensitive parameters. Assessment of capability of CATHARE2 prediction can be established the effective recovery procedures using the code in an actual plant. Most of important physical phenomena in the experiment could be predicted by the CATHARE2 code. The peak pressure in the upper plenum is predicted higher than experimental value by 7 kPa since the differential pressure between the pressurizer and the surge line is overestimated. The timing of core uncovery is delayed by 500 seconds mainly due to discrepancy in the core void distribution. It is demonstrated that openings of the pressurizer manwey and the steam generator manway can prevent the core uncovery using only gravity feed injection. Although some disagreements are found in the detailed phenomena, the code prediction is considered reasonable for the overall system behaviors.

  • PDF

An Experimental Study on Flow Distributor Performance with Single-Train Passive Safety System of SMART-ITL (SMART-ITL 1 계열 피동안전계통을 이용한 유동분사기 성능에 대한 실험연구)

  • Ryu, Sung Uk;Bae, Hwang;Yang, Jin Hwa;Jeon, Byong Guk;Yun, Eun Koo;Kim, Jaemin;Bang, Yoon Gon;Kim, Myung Joon;Yi, Sung-Jae;Park, Hyun-Sik
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.124-132
    • /
    • 2016
  • In order to estimate the effect of flow distributors connected to an upper nozzle of CMT(Core Makeup Tank) on the thermal-hydraulic characteristics in the tank, a simplified 2 inch Small Break Loss of Coolant Accident(SBLOCA) was simulated by skipping the decay power and Passive Residual Heat Removal System(PRHRS) actuation. The CMT is a part of safety injection systems in the SMART (System Integrated Modular Advanced Reactor). Each test was performed with reliable boundary conditions. It means that the pressure distribution is provided with repeatable and reproducible behavior during SBLOCA simulations. The maximum flow rates were achieved at around 350 seconds after the initial opening of the isolation valve installed in CMT. After a short period of decreased flow rate, it attained a steady injection flow rate after about 1,250 seconds. This unstable injection period of the CMT coolant is due to the condensation of steam injected into the upper part of CMT. The steady injection flow rate was about 8.4% higher with B-type distributor than that with A-type distributor. The gravity injection during hot condition tests were in good agreement with that during cold condition tests except for the early stages.

Method for Preventing Asphyxiation Accidents by a CO2 Extinguishing System on a Ship (선박 내 CO2 소화설비에 의한 질식사고 방지 기법)

  • Ha, Yeon-Chul;Seo, Jung-Kwan;Hwang, Jun-Ho;Im, Kichang;Ryu, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.57-64
    • /
    • 2015
  • Carbon dioxide extinguishing systems are broadly used for onshore and offshore fire accidents because of excellent performance and low cost. However, there is risk with carbon dioxide systems, which have caused many injuries and deaths by suffocation associated with industrial and marine fire protection applications. In this study, a numerical analysis was performed to predict the fire suppression characteristics of a carbon dioxide system in the compressor room of ships. A double protection safety system is suggested to prevent suffocation accidents from carbon dioxide extinguishing systems. Four scenarios were selected to study the variation of the heat release rate, maximum temperature, a $CO_2$ and $O_2$ mole fraction, and fire suppression characteristics with the carbon dioxide system. The importance of proper design is suggested for a ventilation system in the compressor room of ships.

A Study on the Probability of BLEVE of Above-ground LP Gas Storage Tanks Exposed to External Fire (지상식 LPG 저장탱크의 외부화재에 의한 BLEVE 가능성 해석)

  • Lee Seung-Lim;Lee Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.19-23
    • /
    • 2003
  • The purpose of this thesis is to investigate the BLEVE probability of LP gas storage tanks which are relatively more dangerous, by the deductive calculating method using the results of Birk's pilot tank test and the required heat capacity of BLEVE. The result that BLEVEs can occur in only above 43.68 percent of liquid filling level under $600^{\circ}C$ of tank pate temperature and $53^{\circ}C$ of inner liquid temperature, was obtained and will be useful for preventing the BLEVE of LP gas storage tanks in fire sites. In addition, this research showed conditions of external leak and fire causing BLEVE, based on 15ton capacity of LP gas tank which has the same specifications as those in Puchon LP gas filling station accident. The result of the calculation is that the minimum pool fire conditions of BLEVE are above 7.2mm equivalent diameter under a liquid release condition and above 17.6mm equivalent diameter under a two-phase release condition. In the end, the result of calculating the pool size corresponding the above conditions using EFFECTS version 2.1, concludes that a minimum of 3.3 meters of diameter and 10.4 meters of height should be needed for BLEVE outbreak.

  • PDF

DISTRIBUTION AND PHYSIOLOGICAL CHARACTERISTICS OF BACILLUS CEREUS IN RICE AND RICE PRODUCTS (미반류에 있어서 Bacillus cereus균의 분포와 생리적특성에 관한 연구)

  • LEE Myeong-Sook;CHANG Dong-Suck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.13 no.4
    • /
    • pp.163-171
    • /
    • 1980
  • Recently, Bacillus has been identified as one of food poisoning bacteria especially in products of cereal foods in foreign countries. Therefore, the quantitative distribution of Bacillus cereus in market foods, its physiological characteristics, growth rate by temperature and heat resistance of its spore were examined. Thirty two samples of cooked rice, 20 samples of kimbab(cooked rice rolled with laver), 23 samples of rice cake, 13 samples of rice ana 13 samples of barley were collected from restaurents and food stores in Busan, Korea during the period from May to November in 1980. Forty samples of 101 samples submitted to the test appeared positive for Bacillus cereus showing abut $40\%$ in detection ratio. Detection ratio of Bacillus cereus was higher than $50\%$ in barley and rice, and about $30\%$ in rice products. Average Bacillus cereus content of in the samples was $2.6\times10^6/g$ in cooked rice, $2.3\times10^6/g$in kimbab, $4.9\times10^4/g$ in rice cake while that in rice and barley was about $10^3/g$. The result of biochemical tests of the bacterium was $100\%$ positive in catalase, egg yolk reaction, gelatin hydrolysis and glucose fermentation, $100\%$ negative in xylose, arabinose and mannitol oxidation, about $90\%$ positive in acetoin production, $80.0\%$ positive in nitrate reduction and citrate utilization and $55.0\%$ positive in starch hydrolysis test. Isolation ratio of Bacillus ceresus which showed haemolysis positive and starch hydrolysis negative results, was about $38\%$ in 40 strains examined. It is known that those strains has a close relation to food poisoning accident. Growth rate and generation time of Bacillus cereus isolated from the cooked rice were $0.34hr^{-1},\;2.02hr\;at\;20^{\circ}C,\;0.73hr^{-1},\;0.95hr\;at\;30^{\circ}C\;and\;0.49hr^{-1},\;1.44\;hr\;at\;40^{\circ}C$ respectively. Heat resistance value of Bacillus cereus spores suspended in phosphate buffer solution was $D_{90}=29.0min,\;D_{95}=8.7min,\;D_{98}=3.7\;min\;and\;D_{101}=2.3\;min(z=10.5)$.

  • PDF

Development of Embedded Board for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm (일체형 방사선 피폭 방호 소방관 인명구조 경보기의 임베디드 보드 개발)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1461-1464
    • /
    • 2019
  • In this paper, we propose the development of embedded board for integrated radiation exposure protection fireman's life-saving alarm capable of location tracking and radiation measurement. The proposed techniques consist of signal processing unit, communication unit, power unit, main control unit. Signal processing units apply shielding design, noise reduction technology and electromagnetic wave subtraction technology. The communication unit is designed to communicate using the wifi method. In the main control unit, power consumption is reduced to a minimum, and a high performance system is formed through small, high density and low heat generation. The proposed techniques are equipment operated by exposure to poor conditions, such as disaster and fire sites, so they are designed and manufactured for external appearance considering waterproof and thermal endurance. The proposed techniques were tested by an authorized testing agency to determine the effectiveness of embedded board. The waterproof grade has achieved the IP67 rating, which can maintain stable performance even when flooded with water at the disaster site due to the nature of the fireman's equipment. The operating temperature was measured in the range of -10℃ to 50℃ to cope with a wide range of environmental changes at the disaster site. The battery life was measured to be available 144 hours after a single charge to cope with emergency disasters such as a collapse accident. The maximum communication distance, including the PCB, was measured to operate at 54.2 meters, a range wider than the existing 50 meters, at a straight line with the command-and-control vehicle in the event of a disaster. Therefore, the effectiveness of embedded board for embedded board for integrated radiation exposure protection fireman's life-saving alarm has been demonstrated.

The Research about the Classification System Improvement and Cord Development of Korean Classification of Disease on Oriental Internal Medicine (한국표준질병사인분류중 한방내과영역의 분류체계 개선 및 진단명 구성에 관한 연구)

  • Lee, Won-Chul
    • The Journal of Internal Korean Medicine
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Objectives : It is necessary that the international classification of diseases (ICD) be examined in order to comprise the third revision of the Korean Classification of Disease on Oriental Medicine (KCD-OM) and disease classification in the oriental internal medicine field. It is essential that the selection, classification and definition of disease and pattern names of oriental concepts in internal medicine be clear. Since 2008, the fifth revision of the Korean Classification of Disease (KCD-5) has been used in Korea. It was required to use the reference classification from the Oriental medicine area based on the ICD-10. Methods : In this review, the necessity for, meaning of and content of the third revision are briefly described. The ICD system was reviewed and KCD-OM was reconstructed. How diagnosis in the oriental internal medicine area had changed is discussed. Review and Results : In 1973, the disease classification of oriental medicine was established the basis on the contents of Dongeuibogam. It was irrespective of the ICD. As to the classification system in the Oriental internal medicine field, systemic disease was comprised of wind, cold, warm, wet, dryness, heat, spirit, ki, blood, phlegm and retained fluid, consumptive disease, etc. Diseases of internal medicine comprised a system according to the five viscera and the six internal organs and followed the classification system of Dongeuibogam. The first and second revisions were of the classification system based on the curriculum in 1979 and 1995. In 1979, in the first revision, geriatric disease and idiopathic types of disease were deleted, and skin disease was included among surgery diseases. This classification was expanded to 792 small classification items and 1,535 detailed classification items to the dozen disease classes. In 1995, in the second revision, it was adjusted to 644 small classes and 1,784 detailed classification items in the dozen disease classes. KCD-OM3 did KCD from this basis. It added and comprised the oriental medical doctor's concept names of diseases considering the special conditions in Korea. KCD-OM3 examined the KCD-OMsecond revised edition (1994). It improved the duplex classification, improper classifications, etc. It is difficult for us to separate the disease names and pattern names in oriental medicine. We added to the U code and made one classification system. By considering the special conditions in Korea, 169 codes (83 disease name codes, 86 pattern name codes) became the pre-existence classification and links among 306 U codes of KCD-OM3. 137 codes were newly added in the third revision. U code added 3 domains. These are composed of the disease name (U20-U33, 97 codes), the disease pattern name (U50-U79, 191 codes) and the constitution pattern name of each disease (U95-U98, 18 codes). Conclusion : The introduction of KCD-OM3 conforms to the diagnostic system by which oriental medical doctors examine classes used with the basic structure of the reference classification of WHO and raises the clinical study and academic activity of the Korean oriental medicine and makes the production of all kinds of nation statistical indices possible. The introduction of KCD-OM3 promotes the diagnostic system by which doctors of Oriental medicine examine classes using the association with KCD-5. It will raise the smoothness and efficiency of oriental medical treatment payments in the health insurance, automobile insurance, industrial accident compensation insurance, etc. In addition, internationally, the eleventh revision work of the ICD has been initiated. It needs to consider incorporating into the International Classification of Diseases some of every country's traditional medicine.