• 제목/요약/키워드: Heat Transfer Control

검색결과 549건 처리시간 0.034초

밀폐형 차량 냉각시스템에 대한 열평형 연구 (A Study on the Heat Balance of Cooling System for Armored Vehicles)

  • 김성광;안석환;남기우
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.70-75
    • /
    • 2007
  • Heat transfer coefficient and fin efficiency of a heat exchanger dispersed in the microelement of control volume were predicted with various flow patterns, conditions and material properties. A computational program was developed by using the method of efficiency-NTU(Number of transfer unit). The modelling was applied to heat exchangers, also was integrated in power pack cooling system in an armored vehicle. The compatibility and the generality were proved by comparing the prediction values with the test results. The developed program may be useful for the design of the cooling system in an armored vehicle.

  • PDF

지중가온이 온실의 난방부하에 미치는 영향 (The Effect of Soil Warming on the Greenhouse Heating Load)

  • 남상운
    • 한국농공학회논문집
    • /
    • 제48권5호
    • /
    • pp.51-60
    • /
    • 2006
  • In order to examine the heat transfer characteristic of a soil warming system and effects of soil warming on the greenhouse heating load, control experiments were performed in two greenhouses covered with double polyethylene film. One treated the soil warming with an electric heat wire and the other treated a control. Inside and outside air temperature, soil temperature and heat flux, and heating energy consumption were measured under the set point of heating temperature of $5,\;10,\;15,\;and\;20^{\circ}C$, respectively. Soil temperatures in a soil warming treatment were observed $4.1\;to\;4.9^{\circ}C$ higher than a control. Heating energy consumptions decreased by 14.6 to 30.8% in a soil warming treatment. As the set point of heating temperature became lower, the rate of decrease in the heating energy consumptions increased. The percentage of soil heat flux in total heating load was -49.4 to 24.4% and as the set point of heating temperature became higher, the percentage increased. When the set point of heating temperature was low in a soil warming treatment, the soil heat flux load was minus value and it had an effect on reducing the heating load. Soil heat flux loads showed in proportion to the air temperature difference between the inside and outside of greenhouse but they showed big difference according to the soil warming treatment. So new model for estimation of the soil heat flux load should be introduced. Convective heat transfer coefficients were in proportion to the 1/3 power of temperature difference between the soil surface and the inside air. They were $3.41\;to\;12.42\;W/m^{2}^{\circ}C$ in their temperature difference of $0\;to\;10^{\circ}C$. Radiative heat loss from soil surface in greenhouse was about 66 to 130% of total heating load. To cut the radiation loss by the use of thermal curtains must be able to contribute for the energy saving in greenhouse.

열연 조압연공정에 있어서의 평균온도 예측모델 개발 (Development of Prediction Model for Average Temperature in the Roughing Mill)

  • 문창호;박해두
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 제5회 압연심포지엄 신 시장 개척을 위한 압연기술
    • /
    • pp.368-377
    • /
    • 2004
  • A mathematical model was developed for the prediction of the average temperature and RDT(RM Delivery temperature) in a roughing mill. The model consisted of three parts as follows (1) The intermediate numerical model calculated the deformation and heat transfer phenomena in the rolling: region by steady state FEM and the heat transfer phenomena in the interpass region by unsteady state FEM (2) The Off-line prediction model was derived from non-linear regression analysis based on the results of intermediate numerical model considering the various rolling conditions, (3) Using the heat flux in rolling region, temperature profile along thickness direction was calculated. For validation of the presented model, the rolling force per pass and RDT measued in on-line process was compared with those of model and the results showed close agreement with the existing data. In order to demonstrate the effectiveness of the proposed model, the various rolling conditions was tested.

  • PDF

파울링 예측을 위한 가스-입자 이상 유동 해석(1)-고온 풍동 설계 및 성능실험- (Particulate Two-Phase Flow Analysis for Fouling Prediction(I)-Design of Hot Wind Tunnel and Its Performance Experiment-)

  • 하만영;이대래
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3695-3705
    • /
    • 1996
  • We designed the hot wind tunnel to reproduce the conditions of utility boiler and carried out its performance test, in order to investigate the particulate two-phase flow behaviour, the fouling and heat transfer characteristics to the heat exchanger. The hot wind tunnel introduces the control system to control the temperature in the test section. The particle is injected into the hot gas stream. The fouling probe (cylindrical tube) is positioned normal to the particulate gas-particle two-phase flow and cooled by the air. The temperature of gas and cooling air, and temperature in the fouling probe are measured as a function of time, giving the local and averaged heat transfer and fouling factor. The shape of particulate deposition adhered to the fouling probe is also observed.

마이크로 캡슐 잠열재 슬러리를 적용한 미소채널 열교환기의 열분배 성능평가 (Experimental Study on the Heat Distribution in the Rectangular Mini Channel Heat Exchangers with MPCM Slurry)

  • 전종욱;백창현;김용찬;김영득;최종민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.645-650
    • /
    • 2006
  • The heat transfer performance and energy transport ability are relatively high due to higher specific heat. Therefore, it can be used in fields such as heating, ventilating, air-conditioning, refrigeration and heat exchangers. In this study, liquid-cooling heat exchangers were designed and tested by varying geometry and operating conditions. In addition, liquid-cooling heat exchangers were tested to provide performance data for MPCM slurry. The liquid-cooling heat exchangers had twelve rectangular channels with flow paths of 1, 2, 4 and 12. Silicon rubber heaters were used to control the heat load to the heat exchanger. Heat input ranged from 293 to 800 W, and inlet temperatures of working fluid varied from 15S to $27^{\circ}C$. The standard deviation of surface temperature was strongly affected by the coolant of MPCM Slurry, All MPCM-cooling heat exchangers showed higher cooling performance than the water-cooling heat exchanger except one path channel heat exchanger.

  • PDF

펄스형 Nd:YAG 레이저와 단락이행모드의 직류 GMA 열원을 이용한 하이브리드 용접 공정에 대한 연구 (A Study on the Process of Hybrid Welding Using Pulsed Nd:YAG Laser and Dip-transfer DC GMA Heat Sources)

  • 조원익;나석주
    • Journal of Welding and Joining
    • /
    • 제25권6호
    • /
    • pp.71-77
    • /
    • 2007
  • Until now, many researches on laser-arc hybrid welding processes have been conducted mainly for high power CW laser and high direct current arc to weld the thick steel plates for shipbuilding. Recently, however the usage of thin steel plates, which tend to be deformed easily by thermal energy, is been increasing because of demand of light structure such as car body in the automobile industry. Accordingly, heat sources having relatively low heat input such as pulsed laser, dip-transfer DC GMA and pulsed GMA seem to be applied more increasingly and the study about those heat sources is needed more intensively. Any heat source mentioned above can not stand alone without weld defects at a relatively high welding speed for increasing the welding productivity. This is main reason to apply the hybrid welding process which uses pulsed laser and low-heat-input GMA heat sources simultaneously to weld the thin steel plate. In this study, parameters of pulsed laser and dip-transfer DC GMA welding are studied firstly through preliminary experiments, and then analyzed in the viewpoint of their physical phenomena. Before conducting the hybrid welding, a pulse control technique is developed based on the parallel port communication and Visual C++ 6.0. Owing to development of this technique, interactions of laser and arc pulses can be controlled consistently. Using the pulse control technique, the hybrid welding is conducted and then its interactive welding phenomenon is analyzed.

대형 가스오븐 시스템의 최적 설계 (Optimization Design of Large Gas Oven Systems)

  • 김도현;유병훈;금성민;이창언
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.205-207
    • /
    • 2015
  • In this study, we examined through experimental study of the combustion conditions in order to optimize the 20,000kcal/hr class combustor being used in the commercial large gas oven. Through a consideration of the shape and the heat transfer area of the heat exchanger that is suitable for supplying heat quantity is designed and manufactured two heat exchangers were examined cooking chamber temperature change of the oven by the convection fan control method through advanced research.

  • PDF

Design of Cooling Channels of Preburners for Small Liquid Rocket Engines with Computational Flow and Heat Transfer Analysis

  • Moon, In-Sang;Lee, Seon-Mi;Moon, Il-Yoon;Yoo, Jae-Han;Lee, Soo-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • 제28권3호
    • /
    • pp.233-239
    • /
    • 2011
  • A series of computational analyses was performed to predict the cooling process by the cooling channel of preburners used for kerosene-liquid oxygen staged combustion cycle rocket engines. As an oxygen-rich combustion occurs in the kerosene fueled preburner, it is of great importance to control the wall temperature so that it does not exceed the critical temperature. However, since the heat transfer is proportional to the speed of fluid running inside the channel, the high heat transfer leads to a trade-off of pressure loss. For this reason, it is necessary to establish a certain criteria between the pressure loss and the heat transfer or the wall surface temperature. The design factors of the cooling channel were determined by the computational research, and a test model was manufactured. The test model was used for the hot fire tests to prove the function of the cooling mechanism, among other purposes.

다공물질 표면처리가 경사판의 증발냉각에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effects of Porous Layer Treatment on Evaporative Cooling of an Inclined Surface)

  • 이대영;이재완;강병하
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.25-32
    • /
    • 2005
  • Falling film heat transfer has been widely used in many applications in which heat and mass transfer occur simultaneously, such as evaporative coolers, cooling towers, absorption chillers, etc. In such cases, it is desirable that the falling film spreads widely on the surface forming thin liquid film to enlarge contact surface and to reduce the thermal resistance across the film and/or the flow resistance to the vapor stream over the film. In this work, the surface is treated to have thin porous layer on the surface. With this treatment, the liquid can be spread widely on the surface by the capillary force resulting from the porous structure. In addition to this, the liquid can be held within the porous structure to improve surface wettedness regardless of the surface inclination. The experiment on the evaporative cooling of an inclined surface has been conducted to verify the effectiveness of the surface treatment. It is measured that the evaporative heat transfer increases about $50\%$ by the porous layer treatment as compared with that from orignal bare surfaces.

NUMERICAL ANALYSIS ON THE NATURAL CONVECTION IN A LONG HORIZONTAL PIPE WITH THERMAL STRATIFICATION

  • Ahn, Jang-Sun;Park, Byeong-Ho;Kim, Seoug-Beom;Kim, Eun-Kee;Park, Man-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.95-101
    • /
    • 1996
  • In this paper, the steady 2-dimensional model for a long horizontal line with different end temperatures undergoing natural convection at very high Rayleigh number is proposed to numerically investigate the heat transfer and flow characteristics. The dimensionless governing equations are solved by using SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm which is developed using control volumes and staggered grids. The numerical results are verified by comparison with the operating PWR test data. The analysis focuses on the effects of variation of the heat transfer rates at the pipe surface, the thermal conductivities of the pipe material and the thickness of the pipe wall on the thermal stratification. The results show that the heat transfer rate at the pipe surface is the controlling parameter. A significant reduction and disappearance of thermal stratification phenomenon is observed at the Biot number of 5.0$\times$10$^{-2}$. The results also show that the increment of the thermal conductivity and thickness of the wall weakens the thermal stratification and somewhat reduces azimuthal temperature gradient in the pipe wall. Those effects are however minor, when compared with those due to the variation of the heat transfer rates at the surface of the pipe wall.

  • PDF