• 제목/요약/키워드: Heat Storage Tank

검색결과 296건 처리시간 0.031초

태양열 급탕 난방 복합 축열조 열성능 (Thermal Performance of Solar Hot Water and Space Heating in a Combi - Storage Tank)

  • 곽희열;주홍진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.266-269
    • /
    • 2009
  • The Purpose of this study was thermal performance of solar hot water and space heating thermal storage tank. The combi storage tank was designed Tank in Tank type. The tank volume for space heating was 700 $\ell $ and tank volume for hot water was 150 $\ell $. Tank in Tank type storage tank was to replace heat exchange to hot water tank. The result showed that the Heating value was 67.25MJ and domestic hot water value was 51.93MJ. Supply to the hot water volume was 521 $\ell $ more than about 3 times as that of the hot water tank volume.

  • PDF

수소저장합금을 이용한 수소저장탱크의 구조에 따른 수소저장 특성 연구 (Study on the Characteristics of Hydrogen Storage according to the Structure of Storage Tank using Metal Hydride)

  • 심규성;명광식;김정덕;김종원
    • 한국수소및신에너지학회논문집
    • /
    • 제13권1호
    • /
    • pp.90-99
    • /
    • 2002
  • In order to utilize hydrogen energy in a large-scale in the future, development of effective hydrogen storage method is essentially required as well as that of efficient hydrogen production method. The hydrogen storage method using metal hydrides has been holding the spotlight as a safer and higher-density hydrogen storage method than conventional hydrogen storage methods such as liquid hydrogen or compressed hydrogen storage method. However when metals react with hydrogen to store hydrogen as metal hydrides, they undergo exothermic reactions, while metal hydrides evolve hydrogen by endothermic reaction. Therefore, hydrogen storage tank should have such structure that it can absorb or release reaction heat rapidly and efficiently. In this study, a review on the improvement of the heat release and absorption structure in the hydrogen storage tank was conducted, and as a result, a new type of hydrogen storage tank with the structure of vertical-type wall was designed and manufactured. Experimental results showed that this new type of tank could be used as an efficient hydrogen storage tank because its structure is simpler and manufacture is easier than cup-type hydrogen storage tank with the structure of packed horizontal cup.

열교환코일 내장형 태양열 축열조의 성능향상 (제1보 실증실험) (Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 1 : Verification Experiment))

  • 이욱재;홍희기
    • 설비공학논문집
    • /
    • 제27권4호
    • /
    • pp.213-219
    • /
    • 2015
  • A thermal storage tank with internal heat exchange coils is commonly used in solar thermal systems with a collector area below $100m^2$. The coils are installed in the lower part of the tank because the temperature of the upper part of the tank can drop if the outlet temperature of the collector becomes lower than the upper temperature of the tank, which is a kind of temperature reversal. As an alternative to the well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and have achieved superior thermal stratification in the tank, which results in increased collector efficiency and solar fraction. But, the phenomenon of temperature reversal was often observed in the tank when the load or solar radiation changed rapidly. In the present work, revised control was successfully applied, i.e., to heat only the lower coil using a three way valve if temperature reversal occurs and to operate the collector at a low flow rate when the quality of solar radiation is not good.

자동차용 액체수소 저장 용기의 열해석 (Thermal analysis of a LH2 storage for vehicles)

  • 오병수;정진삼
    • 한국수소및신에너지학회논문집
    • /
    • 제10권3호
    • /
    • pp.151-157
    • /
    • 1999
  • The development of hydrogen vehicles has been actively progressed in the developed countries such as U. S., Japan and Germany. The most important technology of using hydrogen fuel is to develope a compatible storage tank with respect to the fossil fuel tank. Among many storage methods, the liquid hydrogen is the most desirable state because of the lowest volume and weight. The metal hydride tank is too heavy and the compressed hydrogen tank is too bulky. Because of these reasons, it is the principal purpose to analyze the theoretical heat transfer for designing and manufacturing an actual $LH_2$ tank. The insulation methods of the room between inner and outer vessel are non-vacuum, vacuum, vacuum with MLI(Multi-Layer Insulation). According to the results of the numerically calculated heat leak through the walls of the $LH_2$ tank, the vacuum insulated tank has 20 times and the MLI tank has 5616 times less heat leak than the non-vacuum tank.

  • PDF

수직다발관형 빙축열 탱크내 물의 응고과정시 열전달특성에 관한 연구 (An Experimental Study on the Heat Transfer Characteristics during the Freezing Process of Water in the Vertical Multi Tube Type Ice Storage Tank)

  • 김영기;임장순
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.95-105
    • /
    • 1998
  • In this study, basic design data which were required for development of highly efficient ice storage system with low temperature latent heat were experimentally obtained. The ice storage system considered in this study was the one that has been widly used in the developed country and called the ice-on-coil type. Using the system, the ice storage performance for various design parameters which were the flow direction and the inlet temperature of the secondary fluid was tested. In addition, the timewise variation of the interface profiles between the solid and the liquid were visualized, and the heat transfer characteristics of the Phase Change Material(PCM) in the ice storage tank were Investigated. During the freezing processes in the ice storage tank with several vertical tubes, decrease of the heat transfer area and the heat resistance of the ice layer made the increasing rate of ice packing factor(IPF) less. The total freezing energy for the upward flow of the secondary fluid was higher than that for the downward flow. The average ice storage efficiency for the upward flow of the secondary fluid was higher than that for the downward flow.

  • PDF

석유류 저장 탱크에서의 액면 및 유츌화재에 대한 복사열의 실험적 연구 (Experimental Study of Radiation Heat Flux for the Pool and Spill Fire in Petroleum Storage Tanks)

  • 김홍;박형주
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.88-93
    • /
    • 2004
  • This experimental study was carried out to evaluate effect of the radiation heat flux for the pool and spill fire in petroleum storage tanks, which were made form steel. Each of them had the capacity of 250, 2500 and 25000 liter, respectively. The effects of the radiation heat flux are as follows; 1) The intensity of radiation heat flux from a flame decreased exponentially with increasing distance from outside wall of tanks, and increased significantly with surface area of tank and dyke. 2) In the case of 25000L tank, the radiation heat flux was about max. 98.9kW/$m^2$ in 1m from wall of tank. 3) The distance, that was able to ignite wood or plastics by radiation heat flux of approximately 12.5kW/$m^2$, was about 3.14m from wall of 25000L tank.

축열조를 이용한 냉매과냉각 시스템의 전력수요관리 효과에 대한 연구 (A Study on the DSM Effect of a Refrigerant-Subcooling Refrigeration System with an Ice Storage Tank)

  • 김정배;이은지;이동원
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.845-851
    • /
    • 2010
  • This study was experimentally performed to find the effects of refrigerant subcooling in the refrigeration system and to propose how to get the efficient use of energy. A refrigerant-subcooling refrigeration system consisted of a typical single vapor-compression refrigeration cycle, a subcooler, and an ice storage tank. The degree of subcooling at the exit of the condenser can be increased by the heat transfer between the subcooler and the ice storage tank. The cold heat in the ice storage tank was stored by using the refrigeration cycle during night time and then used to absorb the heat from the subcooler during daytime. The cooling capacity and COP of this system were higher than those of the conventional system due to the increase in the degree of subcooling. Typically, the refrigerant-subcooling system showed superior performance to the conventional refrigeration system and would also contribute to load leveling.

축열수조의 성능에 관한 실험적 연구 (Experimental Study on the Performance of Heat Storage Tank Using Water)

  • 김시범;김효경
    • 대한설비공학회지:설비저널
    • /
    • 제11권2호
    • /
    • pp.10-15
    • /
    • 1982
  • An experimental study on the storage tank which uses sensible heat of water is done. The influence of inlet flow rate (Re), the difference between initial temperature and inlet water temperature(Gr) and the location of inlet and outlet on the performance of storage tank is studied. Development of stratification is examined by measuring the transient temperatures of 36 points inside the tank. Measured values are transformed to the dimensionless parameters in order to calculate the temperature efficiency of storage tank. In the presence of combined natural and forced convection, the development of stratification becomes clearer and thus the efficiency becomes higher, as $Gr/Re^2$ increases.

  • PDF

기상조건과 축열조 용량에 따른 평판형 태양열 집열기 시스템의 동적 성능 해석 (Dynamic performance analysis of flat plate solar collector system according to weather conditions and capacity of heat storage tank)

  • 박배덕;김규덕;김경훈
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.57-65
    • /
    • 2014
  • Solar energy has attracted wide attention as a promising renewable energy source. The goal of this paper is to estimate the dynamic performance of solar flat plate collector system according to the weather conditions and the capacity of heat storage tank. This study provides a detailed description of the modeling methods and materials of the system. The effects of the daily clearness index and the volume of the heat storage tank on the hourly and daily performances of the system are numerically investigated. Special attention is focused on the important system variables including the solar insolation on the collector surface, useful energy, heat loss at the collector, and collector efficiency.

단열을 고려한 초저온 액체질소 저장 탱크의 지지대 용접부 설계 (Weldment Design of Supports for Cryogenic Storage Tank considering Insulation)

  • 최동준;오정택;정재현;조종래
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.131-136
    • /
    • 2008
  • The double-walled steel vessel with powder insulation in the space between the walls is used to minimize heat transfer by radiation and conduction in cryogenic storage tank. The vacuum required the insulation is much less extreme than with high-vacuum or multilayer insulations. The solid supports are used to bear the weight of the inner container. Thermal and structural analysis of the tank have been carried out to study the effect of vacuum and weldment geometry of the internal supports. Heat flux in wall is increased with increasing of thermal conductivity of perlite. Heat flux and stress of support is not affected by weldment geometry.