Browse > Article
http://dx.doi.org/10.5916/jkosme.2008.32.1.131

Weldment Design of Supports for Cryogenic Storage Tank considering Insulation  

Choi, Dong-Jun (부영CST(주))
Oh, Jung-Taek (한국해양대학교 대학원 기계공학과)
Jung, Jae-Hyun (한국해양대학교 기계정보공학부)
Cho, Jong-Rae (한국해양대학교 기계정보공학부)
Abstract
The double-walled steel vessel with powder insulation in the space between the walls is used to minimize heat transfer by radiation and conduction in cryogenic storage tank. The vacuum required the insulation is much less extreme than with high-vacuum or multilayer insulations. The solid supports are used to bear the weight of the inner container. Thermal and structural analysis of the tank have been carried out to study the effect of vacuum and weldment geometry of the internal supports. Heat flux in wall is increased with increasing of thermal conductivity of perlite. Heat flux and stress of support is not affected by weldment geometry.
Keywords
Cryogenic storage tank; Double-walled vessel; Support; Weldment design; Insulation;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 김호연, 최성희, 박영, 이정환, 윤익근, 김동혁, 하종만, 주상우, LNG 저장탱크의 종합 열유동 해석프로그램 개발, 한국가스학회지, Vol.5, No.2, pp. 52-61, 2001
2 Ansys user manual, Ansys Inc
3 ASME Boiler & pressure vessel Sec. II, Part D, ASME, 2007
4 T.M. Flynn, Cryogenic engineering, second ed., 2005, Marcel Dekker
5 Unigraphics NX4, UGS
6 김청균, 최동열, 내부탱크 저장 시스템에서 9% 니켈강재 구조물의 설계 안전성에 관한 연구, 한국가스학회지, Vol.5, No.4, pp. 49-55, 2001
7 박병휘, 이현철, 박두선, 손무룡, 초저온액화가스 저장탱크 내에서의 액화질소의 거동, 한국가스학회지, Vol.2, No.3, pp. 37-48, 1998
8 김청균, 조승현, 초저온 하중을 고려한 내부탱크 바닥판의 설계 안정성에 관한 유한요소해석, 한국가스학회지 제8권 제3호, pp. 8-15, 2004년 9월