• Title/Summary/Keyword: Heat Release rate

Search Result 666, Processing Time 0.025 seconds

Identification of Muscle Proteins Related to Objective Meat Quality in Korean Native Black Pig

  • Hwang, I.H.;Park, B.Y.;Cho, S.H.;Kim, J.H.;Choi, Y.S.;Lee, J.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.11
    • /
    • pp.1599-1607
    • /
    • 2004
  • This study examined the effects of pre-slaughter fasting, chasing stress and chiller ageing on objective meat quality, and their relations to the proteome profile of longissimus muscle using 20 male Korean native black pigs. Treatments were composed of two levels of pre-slaughter feed withdrawal, two levels of pre-slaughter stress and four chiller ageing times. A 15 min chasing stress immediately prior to slaughter significantly (p<0.05) decreased detectable levels of $\mu$-calpain activity during rigor development and chiller ageing, but did not have any direct effect on objective meat quality. On the other hand, pigs fed until the morning of slaughter resulted in significantly (p<0.05) higher hunter L* value and cooking loss than those which received an 18 h feed withdrawal prior to slaughter. Cooking loss and hunter L* value were constant during 7 d of chiller ageing, followed by significant increases at 14 d. The fed animals showed a significantly (p<0.05) higher hunter a* value at both 3 and 7 d, while the other group maintained a stable redness for 7 d. WB-shear force was not affected by the pre-slaughter treatments, but had significant (p<0.05) linear reduction from 1 to 7 d. A gelbased proteome analysis was performed on selected animals for low and high hunter L* values at 1 d. Ten and five spots had greater than two-fold spot densities for the low and high hunter L* groups, respectively. The ten spots included chain A, deoxyribounclease I complex with actin, heat shock protein 27 kDa, a protein similar to cardiac $Ca^{2+}$ release channel, and myosin heavy chain, while the five spots included chain A aldehyde dehydrogenase, glycerol-3 phosphate dehydrogenase, and hemoglobin alpha chain. In general, feeding until the morning of slaughter resulted in more desirable meat color, but appeared to reduce palatability due to increased cooking loss. Proteome analysis demonstrated that various proteins were concomitantly involved in the determination of final meat color. The most noticeable observation in the current study was that various isoforms for a particular protein differed in degradation and/or expression rate depending on meat quality.

Method for Preventing Asphyxiation Accidents by a CO2 Extinguishing System on a Ship (선박 내 CO2 소화설비에 의한 질식사고 방지 기법)

  • Ha, Yeon-Chul;Seo, Jung-Kwan;Hwang, Jun-Ho;Im, Kichang;Ryu, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.57-64
    • /
    • 2015
  • Carbon dioxide extinguishing systems are broadly used for onshore and offshore fire accidents because of excellent performance and low cost. However, there is risk with carbon dioxide systems, which have caused many injuries and deaths by suffocation associated with industrial and marine fire protection applications. In this study, a numerical analysis was performed to predict the fire suppression characteristics of a carbon dioxide system in the compressor room of ships. A double protection safety system is suggested to prevent suffocation accidents from carbon dioxide extinguishing systems. Four scenarios were selected to study the variation of the heat release rate, maximum temperature, a $CO_2$ and $O_2$ mole fraction, and fire suppression characteristics with the carbon dioxide system. The importance of proper design is suggested for a ventilation system in the compressor room of ships.

A Study on Fire Performance Evaluation of EIFS on Anti-Flaming Finish by Cone Calorimeter Test (콘칼로리미터에 의한 외단열시스템의 방염 화재성능평가를 위한 연구)

  • Min, Se-Hong;Sun, Ju-Seok;Kim, Sang-Chul;Choi, Yong-Mook;Lee, Seok-Ki
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.106-111
    • /
    • 2012
  • In this study, EIFS (Exterior insulation finish system) of exterior cladding was applied Cone calorimeter test to confirm the effect of flame retardant. As a results, the initial ignition points in accordance with the coated form and concentration of the flame retardant was delayed. But flame resistant treatment of EIFS cladding to control the fire will not affect confirmed that. In addition, EIFS that uses high-density and low-density due to difference in the density of the impact of the fire was no difference. The exterior of the ignition experiment occurred before and after 40 seconds, heat release rate to 100 seconds appears to occur about 90 % compared with the other exterior wall materials, the initial fire spread very fast was confirmed. EIFS cladding in order to prevent the spread of fire in the application of EIFS legally use is limited by the use of the building. And flame spread can be prevented, such as a vertical outer wall compartment measures are urgently needed.

A Study on the Fire Spread Risk of Resident Buildings With Pilotis (필로티 건물 이격거리에 따른 화재확산 위험성 연구)

  • Choi, Seung-Bok;Choi, Doo-Chan;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.103-110
    • /
    • 2017
  • With the common tendency in the accordance with the trend, low-stories built edifices that are Pilotis-oriented structured exponentially and constantly increasing its number of buildings. It inevitably contains its risks of facing conflagrations as most of its part is used as parking lots. In the parking lots, the length of the flame has a heavy-weighted possibility that it would get increased because the heat release rate gets relatively high due to the vehicle insulation. Following on top of that, due to the nature of the Pilotisconsisting of pillars, there is a risk of flame spread to the adjacent building if the same Pilotis-structured buildings are adjacent to each other, if the flame spreads to the surroundings due to the influence of the wind. Because the most of the pilotis-structured-buildings have this entrance that makes the residents be able to enter, if the entrance were plugged the resident get a serious risk of a poisonous gas and a flame. Therefore, if the parking-lots of the pilotis-structured-buildings are adjacent to each other it requires a space to prevent the place from the spread of flame. This research studied how far is appropriate to prevent flame spreading with FDS. As a result, the study found that the distance at least 3.0 m is required.

Comparison of the Flame Height of Pool Fire according to Combustion Models in the FDS (FDS의 연소모델에 따른 풀화재의 화염높이 비교)

  • Han, Ho-Sik;Hwang, Cheol-Hong;Oh, Chang Bo;Choi, Dongwon;Lee, Sangkyu
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.42-50
    • /
    • 2018
  • The effect of sub-grid turbulence and combustion models on the mean flame height in a heptane pool fire according to the Fire Dynamics Simulator (FDS) version (5 and 6) based on Large Eddy Simulation (LES) was examined. The heat release rate for the fire simulation was provided through experiments performed under identical conditions and the predictive performance of the mean flame height according to FDS version was evaluated by a comparison with the existing correlation. As a result, the Smagorinsky and Deardorff turbulence models applied to FDS 5 and 6, respectively, had no significant effects on the mean flow field, flame shape and flame height. On the other hand, the difference in pool fire characteristics including the mean flame height was due mainly to the difference in the mixture fraction and Eddy Dissipation Concept (EDC) combustion models applied to FDS 5 and 6, respectively. Finally, compared to FDS 6, FDS 5 provided the predictive result of a significantly longer flame height and more consistent mean flame height than the existing correlation.

Study on Horizontal and Vertical Temperature Analysis of Cable Fire in Common Duct using Room Corner Experiment (룸코너 실험을 이용한 공동구 케이블 화재 시 수평·수직 방향 온도 분석에 관한 연구)

  • JaeYeop Kim;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.634-643
    • /
    • 2023
  • Purpose: Underground common duct fires are steadily occurring, and the proportion of property damage is particularly large among property and human casualties caused by fires. Especially, cable fires that occur in common areas can spread vertically quickly and pose a great risk. This paper aims to scientifically analyze the nature of the fire by reproducing the fire through experiments. Method: To analyze the characteristics of cable fires in underground common duct, heat release rate and temperature changes were measured through Room-corner (ISO 9705) test, and the vertical and horizontal propagation of cable fires was quantitatively compared and analyzed. Result: The Room Corner Test (ISO 9705) was used to compare the temperature changes at each data logger point. The results showed that the time it took for the fire to reach the ignition temperature in the horizontal and vertical directions from the center point of the first-tier cable was 589 seconds and 536 seconds, respectively, which means that the vertical fire propagation is 53 seconds faster than the horizontal propagation. This proves that the vertical propagation of fire is relatively faster than the horizontal propagation. The horizontal propagation speed of the fire was also compared for each floor cable tray. The results showed that the third-tier cable propagated at 3.4 times the speed of the second-tier cable, and the second-tier cable propagated at 1.5 times the speed of the first-tier cable. This means that the higher the cable is located, the faster the fire spreads and the larger the fire becomes. Conclusion: This study identified the risks of cable fires and analyzed the risks of vertical fire propagation during cable fires based on the results of the Room Corner Test. Studies to prevent the spread of fire and fire response policies to prevent vertical fire propagation are required. The results of this study are expected to be used to assess the fire risk of common areas and other fires.