• 제목/요약/키워드: Heat Radiation Holes

검색결과 10건 처리시간 0.023초

모터싸이클 디스크 브레이크의 열 및 응력 해석을 통한 형상 설계 (A Study on Shape Design of Motorcycle Disk using Thermal and Stress Analysis)

  • 강석현;박시형;이성수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.363-368
    • /
    • 2001
  • Studies on brake system recently are focused on braking performance, especially the consideration on safety of braking system in an extreme situation and reduction of vibration and noise during braking operation. The thermal crack and Judder from the friction between brake disc and pad can bring the threaten of passengers' safety in the end. Braking force comes from the change of kinetic energy to friction energy. Since heat energy is developed from here, the analysis on thermal stress and thermal strain can be the good data when selecting the material of brake pad and designing heat radiation holes on the disc and it will also be the data when designing the thickness of the disc. This paper is intended to show a creative design method by suggesting the thermal analysis data through FEM study and using shape design parameters.

  • PDF

AMTEC내 저압용기에서의 열복사차단막 형상에 따른 발전량 향상 해석 (Analysis on Improving Power of Thermal Radiation Shield in Low Pressure Chamber of AMTEC)

  • 정원식;;이욱현;이계복;이석호
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.54-62
    • /
    • 2016
  • 열을 전기로 바꾸는 장치로 가장 효율이 우수한 장치인 AMTEC은 알칼리금속을 작동유체로 하여 열을 직접적으로 전기로 변환시키는 장치이다. AMTEC은 저압용기, 고압용기, 베타 알루미나 고체 전해질, 그리고 순환윅으로 이루어져있다. AMTEC에서의 열손실은 주요하게 저압용기에서의 BASE와 응축부 사이에서 발생하는 열복사손실이며, 암텍의 발전량은 BASE의 온도유지력에 영향을 받기에 BASE의 표면온도를 고온으로 유지시켜주어야 고효율 발전량은 일정하게 유지할 수 있다. 이를 위하여 저압챔버에서의 복사 열손실을 줄이고 BASE온도는 상승시키고, AMTEC 시스템의 발전량 향상을 위하여 저압용기 내부의 6가지 형태의 열복사차단막에 따른 출력을 전산유체해석을 통하여 분석하였다. 분석에서 최적의 열복사차단막 형상은 수직부에 곡률을 가질 때이며, 그 때의 온도에 대한 무차원수(응축부온도/BASE온도 비)는 0.665 정도이고 출력은 약 17.69 W 정도로 다른 형상에 대비하여 높은 발전량을 갖는 것으로 계산되었다. 높이에 따른 발전량의 차이에서는 수평차단막이 BASE 상부로부터 멀리 떨어진 경우 발전량이 가장 우수하며, 17.58W 정도로 나타났다. 여러 개의 작은 홀과 다중 수평차단막을 설계한 경우는 기준이 되는 형상보다 오히려 발전량이 감소하였으며, 각각 0.91W, 2.06W 정도 감소하였다.

NEW PROBES OF INTERGALACTIC MAGNETIC FIELDS BY RADIOMETRY AND FARADAY ROTATION

  • KRONBERG PHILIPP P.
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.343-347
    • /
    • 2004
  • The energy injection of galactic black holes (BH) into the intergalactic medium via extragalactic radio source jets and lobes is sufficient to magnetize the IGM in the filaments and walls of Large Scale Structure at < [B] > ${\~}0.l{\mu}G$ or more. It appears that this process of galaxy-IGM feedback is the primary source of IGM cosmic rays(CR) and magnetic field energy. Large scale gravitational infall energy serves to re-heat the intergalactic magnetoplasma in localities of space and time, maintaining or amplifying the IGM magnetic field, but this can be thought of as a secondary process. I briefly review observations that confirm IGM fields around this level, describe further Faraday rotation measurements in progress, and also the observational evidence that magnetic fields in galaxy systems around z=2 were approximately as strong then, ${\~}$10 Gyr ago, as now.

LNG 재기화 공정에서 LNG 누출에 따른 화재 및 폭발사고의 피해영향 분석 (Analysis of the Impact of Fire and Explosion Accidents due to LNG Leaks in the LNG Re-gasification Process)

  • 이윤호
    • 해양환경안전학회지
    • /
    • 제24권6호
    • /
    • pp.825-833
    • /
    • 2018
  • 본 연구에서는 LNG 공급계통시스템의 재기화 공정에서 배관 손상으로 인한 누출사고 발생시 LNG 성분 및 누출공의 크기에 따른 연소특성에 대한 피해범위를 산출하고, 피해영향을 해석하였다. LNG 성분에 따른 연소특성을 확인하기 위하여 7곳의 LNG 산지별 위험도를 확인한 결과 산지별 큰 차이를 보이지 않았으나, LNG 구성성분 중 메탄의 함유량이 많을수록 플래시화재 발생범위 및 증기운 폭발에 의한 과압이 발생하는 위험범위 그리고 제트화재 발생에 의한 열 복사량 피해영향이 다른 산지에 비해 비교적 낮음을 알 수 있었다. 또한 배관 누출공의 크기에 따라 누설, 파공, 파괴 3단계에 나누어 위험 범위 및 폭발에 미치는 영향에 대한 연구를 수행하였으며, 플래시화재로 인한 피해영향범위를 계산하고, 이에 따라 LNG 누출시 화재가능 위험범위를 확인했으며, 과압의 영향 및 복사열로 부터의 피해범위를 예측할 수 있었다. 이를 통해 LNG 조성 및 배관 누출공의 크기가 화재 및 폭발에 미치는 영향을 예측할 수 있었다.

카본을 첨가한 LTCC 그린 시트에서 UV 레이저를 이용한 미세 홀 터짐 현상 제어 (Control of Explosion Behavior in Micro Hole Using UV Laser on LTCC Green Sheets Containing Carbon Particles)

  • 김시연;안익준;여동훈;신효순;윤호규
    • 한국전기전자재료학회논문지
    • /
    • 제29권12호
    • /
    • pp.786-790
    • /
    • 2016
  • Hole explosion behaviors were observed during drilling fine holes with laser beam on the LTCC green bar of $320{\mu}m$ thick after lamination of green sheets prepared by tape casting of thick film process. The incidence of these hole explosions was inversely proportional to hole sizes. The incidence of hole explosion was 20 % number of hole with the size of $60{\mu}m$ exploded for the UV radiation, while the explosion did not appear for hole sizes over $100{\mu}m$. To prevent hole explosion behavior during laser-drilling of fine holes, carbon black powder was added as an additive in the LTCC composition, which has superior thermal durability. As a consequence, hole explosion rate was suppressed to 0.8 % for the hole size of $50{\mu}m$ green sheet with the carbon black amount of 10 weight % and the laser power of 3 watt. Added carbon is thought to reduce the heat-affected region during laser drilling.

발전용 희박예혼합 가스터빈에서 연소모드변환 시기의 연소특성 해석 (Numerical Analysis of Combustion Characteristics during Mode Transfer Period in a Lean Premixed Gas Turbine for Power Generation)

  • 정재화;서석빈;김종진;차동진;안달홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.279-282
    • /
    • 2002
  • Recently, gas turbines for power generation adopt multistage DLN(Dry Low NOx) type combustion, where diffusion combustion is applied at low load and, with increase in load, the combustion mode is changed to lean premixed combustion to reduce NOx emissive concentration. However, during the mode changeover from diffusion to premixed flame, unfavorable phenomena, such as flashback, high amplitude combustion oscillations, or thermal damage of combustor parts could frequently occur. In the present study, to apply for the analysis of such unfavorable phenomena, three-dimensional CFD investigations are carried out to compare the detailed flow characteristics and temperature distribution inside the gas turbine combustor before and after combustion mode changeover. The fuel considered here is pure methane gas. A standard $k-{\varepsilon}$ turbulence model with wall function and a P-N type radiation heat transfer model, have been utilized. To analyze the complex geometric effects of combustor parts on combustion characteristics, fuel nozzles, a swirl vane f3r fuel-air mixing, and cooling air holes on the combustor liner wall, are included in this simulation.

  • PDF

이동식 미분무수 노즐의 소화 특성에 대한 수치 시뮬레이션 (Thermal Numerical Simulation on Fire Suppression Characteristics through Mobile Mist Spray Nozzles)

  • 배강열;정희택;김형범;정인수;김창
    • 동력기계공학회지
    • /
    • 제13권5호
    • /
    • pp.25-33
    • /
    • 2009
  • In the present study, the numerical investigation has been carried out to see the effects of water mist sprays on the fire suppression mechanism. The special-purposed program named as FDS was used to simulate the interaction of fire plume and water mists. This program solves the fire-driven flows using LES turbulence model, the mixture fraction combustion model, the finite volume method of radiation transport for a non-scattering gray gas, and conjugate heat transfer between wall and gas flow. The computational domain was composed of a rectangular space dimensioned as $L{\times}W{\times}H=4.0{\times}4.0{\times}2.5\;m^3$ with a mist-injecting nozzle installed 1.0 m high from the fire pool. In this paper, two types of nozzles were chosen to compare the performance of the fire suppression. Numerical results showed that the nozzle, type A, with more orifices having smaller diameters had poorer performance than the other one, type B because the flow injected through side holes deteriorated the primary flow. The fire-extinguishing time of type A was 2.6 times bigger than that of type B.

  • PDF

Evaluation of the KN-12 Spent Fuel Transport Cask by Analysis

  • Chung, Sung-Hwan;Lee, Heung-Young;Song, Myung-Jae;Rudolf Diersch;Reiner Laug
    • Nuclear Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.187-201
    • /
    • 2002
  • The KN-12 cask is designed to transport 12 PWR spent nuclear fuels and to comply with the requirements of Korea Atomic Energy Act, IAEA Safety Standards Series No.57-1 and US 10 CFR Part 71 for a Type B(U)F package. It provides containment, radiation shielding, structural integrity, criticality control and heat removal for normal transport and hypothetical accident conditions. W.H 14$\times$14, 16$\times$16 and 17$\times$17 fuel assemblies with maximum allowable initial enrichment of 5.0 wt.%, maximum average burn-up of 50,000 MWD/MTU and minimum cooling time of 7 years being used in Korea will be loaded and subsequently transported under dry and wet conditions. A forged cylindrical cask body which constitutes the containment vessel is closed by a cask lid. Polyethylene rods for neutron shielding are arranged in two rows of longitudinal bore holes in the cask body wall. A fuel basket to accommodate up to 12 PWR fuel assemblies provides support of the fuels, control of criticality and a path to dissipate heat. Impact limiters to absorb the impact energy under the hypothetical accident conditions are attacked at the top and at the bottom side of the cask during transport. Handling weight loaded with water is 74.8 tons and transport weight loaded with water with the impact limiters is 84.3 tons. The cask will be licensed in accordance with Korea Atomic Energy Act 3nd fabricated in Korea in accordance with ASME B&PV Code Section 111, Division 3.

자기장이 열형광선량계의 글로우 곡선에 미치는 영향 (The Effects of Magnetic Field on TLD Glow Curve)

  • 제재용;강은보
    • 한국방사선학회논문지
    • /
    • 제7권6호
    • /
    • pp.415-418
    • /
    • 2013
  • 방사선을 조사한 시료를 가열하면 시료로부터 흡수된 에너지의 일부가 더 긴 파장의 빛으로 방출되는 것을 이용한 것이 열형광선량계이다. 본 연구의 목적은 피폭선량계로 널리 이용되는 8개의 TLD-100에 동일한 조건에서 열처리와 방사선을 조사하여 자기장을 노출하지 않은 4개와 자기장에 노출시킨 4개를 글로우 곡선을 분석 하였다. 실험 결과 방사선 조사로 포획된 전자가 자기장 노출에 의해 낮은 트랩의 전자들 중 일부는 가전자대의 정공과 결합하여 48%의 피크 면적이 감소하였다. 낮은 트랩의 면적 감소로 인하여 자기장에 노출된 TLD-100은 낮은 선량을 나타내었다. 또한 낮은 트랩의 활성화 에너지는 1.6 eV와 1.5 eV로 나타났다.

축분뇨처리를 위한 Bin형 부숙조- Sundry 시스템의 퇴비화효율 평가 (Composting Effectiveness of A Sundry System with A Bin-type Composter for Recyle of Animal Wastes)

  • 최홍림;김현태;정영윤
    • 한국농공학회지
    • /
    • 제35권2호
    • /
    • pp.92-103
    • /
    • 1993
  • A sunday system with a horizontal bin-type composter was constructed and operated to evaluate its composting performance for four days for each test in October, 1992. A sundry system is one of popular systems for composting livestock manure, of which main benefit is to utilize unlimited, clean, and free solar radiation. A rectangular concrete bin(composter) with dimension of 300cm(length) X90cm(width) X60cm(height) was bedded alternatively with four lanes of aeration pipes and heating pipes, and was insulated at three walls with 50mm styrofoam. Each aeration pipe of a diameter of 25mm had 4mm perforated holes at every 15cm longitudinally, and supplied air of about 2m$^3$/min to the composter to maintain aerobic condition . A stirrer rotating at 1 rpm made one round trip every 20 minutes on the conveying chain along the the length of the composter. Five tests (Test 1~Test 5) were implemented to evaluate the composting effectiveness of a sundry system with a horizontal bin-type composter. Treatments of two levels of the mixture ratio of swine manure and paper sludge cakes(manure : paper sludge cakes= 1 : 4 and 1 : 2) and two levels of the water content(W/C ; 70% and 50%) were made to test the significance of the physicochemical properties for decomposition of the mixture materials. Temperature, C/N ratio, water content, microbial activity of the composting materials were taken measurements to evaluate its performance with the lapse of composting time for tests. A small-scale sundry system with a bin-type composter did not appear to be an appropriate system for composting livestock manure. Since heat generation by the composting materials could not overcome heat loss due to areation in a small-scale composter, a proper thermal enviroment could not be maintained to propagate massively thermopilic microorganism relatively in a short period of time. Different from the result of Chol et al.(1992) 6), a temperature variation of the composting materials did not show the peak clearly and C/N ratio didn't lower with time as expected. Mesophilic microoragnism seemed to play an important role for decomposition of the mixture materials. A sundry system with a bin-type composter may be good for a large-scale livestock farm household which may produce enough animal manure. Therefore a decision should be made very carefully to choose a system for composting livestock waste.

  • PDF