• Title/Summary/Keyword: Heat Panel

Search Result 397, Processing Time 0.026 seconds

Heat and Flow Analysis for Cooling Fan for an Optical Archive System (광학식 대용량 정보저장장치의 냉각용 펜의 열유동 해석)

  • Kim, Jae Hoo;Rhim, Yoon Chul
    • Transactions of the Society of Information Storage Systems
    • /
    • v.11 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • An archive system is designed to store data for a long time without loss. However, many important factors such as temperature, dust, vibration, and humidity must be considered to design a successful archive system. Read/write devices, for example optical disk drives(ODDs), in an archive system generate heat while they are in operation. Fans are usually used to remove heat but the air flow accompanies dust into the system result in system failure. In this study, an archive system with six ODDs is chosen as an analysis model and flow together with temperature distributions are computed using a CFD simulation package. Flow analysis is focused on four cooling fans at the rear panel and temperature distribution is studied for various cases of fan operation. From the temperature point of view, fans give significant effects on $4^{th}$ to $6^{th}$ ODDs compared to the $1^{st}$ to $3^{rd}$ ODDs. Also, it is noticed which fan is the most important as far as cooling is concerned.

A Design and Application of the Ventilating and Heating System of T-103 Trainer Aircraft for Improvement (T-103 훈련기의 환기와 난방 시스템 개선에 관한 연구)

  • Jung, Daehan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.277-284
    • /
    • 2013
  • In this paper, the ventilating and heating system of T-103 trainer aircraft were investigated and redesigned to improve its poor performance. The ventilation system of the trainer was designed to increase the mass flow rate of fresh air by using air intake valves. The flow-in air through the air intake valve is supplied to the cabin by the ram effect of aircraft and the propeller. And the additional heating system was installed to improve the temperature of the cabin inside. The wasted heat from the exhaust gas of the engines was used as heat source of the additional heating system by installing an heat exchanger around the exhaust nozzle. The additional fresh air and the heated air enter the cabin via two ducts mounted under the instrument panel and behind the pedal in the cabin. The additional ventilating and heating system can be controlled by the first pilot and the secondary pilot individually using the control knob equipped separately. After mounting the additional ventilating and heating system, evaluations such as inspection of parts and component, ground run-up test, in-flight test, user test, etc. were conducted. The result of the tests was sufficient to meet the requirements of the manuals, and the pilots were satisfied with the additionally mounted systems.

The Impact of Environmental Health Factors on Extreme-heat Vulnerability Assessment in a Metropolitan City (환경보건적 요소가 도시 내 폭염 취약성 평가 결과에 미치는 영향 분석)

  • Lee, Won-Jung;Kang, Jae-Eun;Kim, Yoo-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.6
    • /
    • pp.492-504
    • /
    • 2013
  • Objectives: This analysis seeks to evaluate the impact of environmental health factors (EHF; e.g. hospital beds per capita, employees of medical institutions) on extreme-heat vulnerability assessment in Busan Metropolitan City during 2006-2010. Methods: According to the vulnerability concept suggested by the Intergovernmental Panel on Climate Change (IPCC), extreme-heat vulnerability is comprised of the categories of Exposure, Sensitivity, and Adaptive Capacity (including EHF). The indexes of the Exposure and Sensitivity categories indicate positive effects, while the Adaptive capacity index indicates a negative effect on extreme-heat vulnerability. Variables of each category were standardized by the re-scaling method, and then each regional relative vulnerability was computed with the vulnerability index calculation formula. Results: The extreme-heat vulnerability index (EVI) excepting EHF was much higher in urban areas than in suburban areas within the metropolitan area. When EHF was considered, the difference in the EVI between the two areas was reduced due to the increase of the Adaptive capacity index in urban areas. The low EVI in suburban areas was induced by a dominant effect of natural environmental factors (e.g. green area) within the Adaptive capacity category. Conclusions: To reduce the vulnerability to extreme heat in urban areas, which were more frequently exposed to extreme heat than others areas, public health and natural environments need to be improved in sensitive areas.

Heating and Cooling Performance Analysis of Ground Source Heat Pump System in Low Energy House (저에너지주택의 지열히트펌프시스템 냉·난방 성능분석)

  • Baek, Namchoon;Kim, Sungbum;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.10
    • /
    • pp.387-393
    • /
    • 2016
  • A ground source heat pump system maintains a constant efficiency due to its stable heat source and radiant heat temperature which provide a more effective thermal performance than that of the air source heat pump system. As an eco-friendly renewable energy source, it can reduce electric power and carbon dioxide. In this study, we analyzed one year of data from a web based remote monitoring system to estimate the thermal performance of GSHP with the capacity of 3RT, which is installed in a low energy house located in Daejeon, Korea. This GSHP system is a hybrid system connected to a solar hot water system. Cold and hot water stored in a buffer tank is supplied to six ceiling cassette type fan coil units and a floor panel heating system installed in each room. The results are as follows. First, the GSHP system was operated for ten minutes intermittently in summer in order to decrease the heat load caused by super-insulation. Second, the energy consumption in winter where the system was operated throughout the entire day was 7.5 times higher than that in summer. Moreover, the annual COP of the heating and cooling system was 4.1 in summer and 4.2 in winter, showing little difference. Third, the outlet temperature of the ground heat exchanger in winter decreased from $13^{\circ}C$ in November to $9^{\circ}C$ in February, while that in summer increased from $14^{\circ}C$ to $17^{\circ}C$ showing that the temperature change in winter is greater than that in summer.

Analysis on the Advanced Model for Solar Energy Harvesting (개선된 태양 에너지 하베스팅 모델에 대한 분석)

  • Nayantai, Bulganbat;Kong, In-Yeup
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.2
    • /
    • pp.99-104
    • /
    • 2013
  • Replacement of sensor nodes for monitoring a wide range area such as mountains and forests needs a lot of time and cost. Using new and renewable energy around them can maximize the lifetime of wireless sensor networks, in which solar energy is infinite energy source that is available in 365 days. To design these sensor networks, solar energy model is essential and to estimate and analyze the overall photovoltaic energy. Using this, we can figure out important data such as the size and performance of solar panel needed. However, existing researches for solar energy harvesting consider parts of many factors to influence the quantity of solar energy gathered. In this paper, we suggest advanced solar energy harvesting model considering angular loss (solar cell panel), overheat loss (solar cell), rechargeable battery heat and cooling for each monthly properties. From our experimental results according to outdoor temperature, panel angle and the surface temperature of solar panel, we show these impact factors are correctly configured.

A study on the Deformation of Variable Reactor / Capacitor for High-frequency Welder Due to the Change on the Velocity of Coolant (냉각수 유속 변화에 따른 고주파 용접기용 가변 리엑터 / 커패시터의 변형에 관한 연구)

  • Kook, Jeong-Han;Park, Gwang-Jin;Kim, Key-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4288-4295
    • /
    • 2011
  • In this paper, variable reactor and capacitor for high-frequency welder are analyzed by optimum design. As the polar panel of high-frequency welder has the role of condenser, the material with the high rate of induced electricity has to be selected in order to manufacture the condenser with the great power cut. And the area of polar panel must be large and the gap between panels must be thin. On the contrary, the resistance is generated and the heat is happened because the large current is flown. To prevent the thermal deformation of this polar panel, the temperature can be lowered by using cooling water and so on. At this point, the speed of cooling water due to deformation and temperature of polar panel can be optimized.

Evaluation of Technical Production Efficiency and Business Structure of Domestic Combined Heat and Power (CHP) Operators: Panel Stochastic Frontier Model Analysis for 16 Collective Energy Operators (국내 열병합발전사업의 기술적 생산효율성 추정 및 사업구조 평가: 16개 집단에너지사업자에 대한 패널 확률프론티어모형(SFA) 분석)

  • Lim, Hyungwoo;Kim, Jaehyeok;Shin, Donghyun
    • Environmental and Resource Economics Review
    • /
    • v.30 no.4
    • /
    • pp.557-579
    • /
    • 2021
  • Collective energy is an intermediate stage in energy conversion and has a great influence on the power structure as a distributed power source. However, the problem of the collective energy business has recently emerged due to the worsening profitability of some collective energy operators. This study measured the technical efficiency of major operators through the estimation of the production efficiency of Korean collective energy operators, and based on this, we looked at ways to improve the profit structure of operators. After collecting detailed data from 16 collective energy operators between 2016 and 2019, the production efficiency of operators was estimated using the panel stochastic frontier model. As a result of the estimation, combined steam power operators showed the highest production efficiency and reverse CHP operators showed the lowest efficiency. Furthermore, as a result of examining the factors influencing profitability, it was confirmed that production efficiency has a positive effect on overall profitability. However, businesses with a high proportion of heat production, such as small district electricity operators, profitability was lower. This phenomenon is due to the structural limitations of the current heat sales market. Hence, the adjustment of the heat sales unit price is necessary to improve profitability of collective energy operators.

Gasification of Surface Carbon Contaminant during Discharge in Plasma Display Panel (PDP)

  • Soh, Hyun;Cho, Sung-Ho;Kim, Young-Chai
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.795-798
    • /
    • 2003
  • Inside of working PDP, there exist highly reactive conditions in the gap between two glass panels. MgO layer and phosphor have been investigated as a function of discharge and temperature. A drastic reduction in carbon impurity was observed on the surfaces after discharging and heat treatment. Carbon composition on the MgO and phosphor is a dominant factor for their instability

  • PDF

Study on Low Frequency Characteristics of Rotary Compressor (로타리 압축기 저주파 특성에 관한 연구)

  • Byoungha Kwon;Park, Sinkyu;Insu Hwang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.384.2-384
    • /
    • 2002
  • Compressor is a major noise source of air-conditioner. Especially, its low frequency band noise below 1000㎐ is very important because it will not be attenuated by passing through the cover panel and heat exchanger in air-conditioner. The factors affecting the low frequency band noise are studied by geometric similarity along with several experiments, and the low frequency noise is closely related with the discharge holes of muffler as well as the cavity of lower shell. (omitted)

  • PDF

Precision analysis on the ISO 13784-1's Round Robin scenarios (ISO 13784-1 RRT 결과의 정밀도 분석)

  • Park, Kye-Won;Jeong, Jae-Gun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.333-336
    • /
    • 2012
  • ISO 13784-1 sandwich panel tests were conducted by FILK, KICT in Korea, SP in Sweden and CSIRO in Australia. Sandwich panels composed of steel sheets, EPS and glass wool supplied by FILK were tested. Mainly heat release rate was compared and equlity of distribution also analyzed on the point of statistical view based on ISO.

  • PDF