• 제목/요약/키워드: Heat Loss Effect

검색결과 520건 처리시간 0.026초

주위의 열대류계수가 다를때 사각핀으로부터의 열손실에 대한 비대칭적인 핀바닥온도의 영향 (Effect of Asymmetric Root Temperature on the Heat Loss From a Rectangular Fin Under Unequal Surrounding Heat Convection Coefficient)

  • 강형석;김성준
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1567-1571
    • /
    • 1994
  • Under the assumption that thermal conductivity of the fin is constant and the conditions ate steady state, effects of non-constant and thermally asymmetric root temperature and unequal surrounding convection coefficients of the fin on the heat loss from a fin of rectangular profile are investigated. The heat loss form a rectangular fin becomes maximum when the highest root temperature deviates from the fin center to the fin side which has a higher convection coefficient as surrounding convection coefficients of the fin increase and as the difference between the convection coefficient of fin top side and that of fin bottom side increases.

기존 노후건축물의 최적 리모델링 개선안 연구 (Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds)

  • 김대원;정광섭;김영일;남아리새;오세민
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.207-216
    • /
    • 2014
  • 에너지손실을 분석해 보면 열전달에 의한 손실과 공기유동에 의한 손실로 구분할수 있다. 열전달은 외벽, 지붕, 바닥의 열관류율에 의한 손실로 기존건축물의 가장 취약한 부분의 한 요소이다. 이런 손실을 방지 하려면 창을 포함한 외벽 전체의 평균 열관류율을 지역 기준값 이상으로 올리고 창의 기밀성을 확보함에 따라 방지 할수 있다. 노후건축물의 가장 취약한 부분이 외벽과 창호 이지만 출입문을 통한 침기량은 연돌효과에 의해 층계단을 타고 올라감과 동시에 각층의 공기를 흡입하여 더큰 유동을 잃으켜 층의 단열성 까지 취약하게 만드는 구조로 되어 있다. 현장 조사를 통한 진단과 에너지 개선처방이 제시될 때 반드시 건물전체에 대한 진단과 각층 부분에 대한 개선안이 함께 제출되어 단순히 창 교체만 하면 에너지절감을 이룰수 있다는 착각에서 벗어나야 할 것이다.

수분 섭취의 증가가 닭의 고온 스트레스 완화에 미치는 효과 (Effect of Increased Water Intake on the Alleviation of Heat Stress in Chicken)

  • 이봉덕
    • 한국가금학회지
    • /
    • 제21권2호
    • /
    • pp.93-99
    • /
    • 1994
  • Chickens subjected to heat stress decrease their heat production by consuming less feed. The lowered feed intake naturally brings about decreased production performance of chicken. The only exception to this is the increased survivability. Birds drink less when they eat less. In hot enviror-mental temperature, chicken need more water for increased heat loss through evaporation an increased urine excretion. Thus, the increased water intake may alleviate the heat stress of chicken. Various electrolytes supplementation to feed or drinking water can alleviate the heat stress of chicken by their effect of increasing water intake. Lasalocid, an ionophorous coccidiostat, was found to have the effect of increasing water consumption of chicken, thereby improving the lowered production performance of heat-stressed chicken. Finally, dietary fiber could be another possible element which can exert beneficial effects on heat-stressed chicken.

  • PDF

지하 열저장 공동의 종횡비와 저장용량에 따른 열성층화 및 열손실 (Thermal Stratification and Heat Loss in Underground Thermal Storage Caverns with Different Aspect Ratios and Storage Volumes)

  • 박도현;류동우;최병희;선우춘;한공창
    • 터널과지하공간
    • /
    • 제23권4호
    • /
    • pp.308-318
    • /
    • 2013
  • 열저장소 내 열성층화는 에너지저장 시스템의 효율을 향상시키고 수요 발생시 더 많은 유효에너지를 공급하기 위해 필수적인 기술이다. 일반적으로 저장소의 종횡비(폭에 대한 높이의 비)와 크기에 따라 열성층도가 달라지는 것으로 알려져 있다. 본 논문은 열수 저장을 위한 암반공동의 종횡비와 저장용량이 저장공동 내 열성층화와 외부로의 열손실에 미치는 영향을 조사하는 데 연구 목적이 있다. 이를 위해 전산유체역학 코드인 FLUENT를 이용하여 암반공동의 종횡비와 저장용량에 따른 열전달 시뮬레이션을 수행하였다. 성층도 정량화 지수를 이용하여 시간경과에 따른 열성층화의 변화를 분석하였으며, 저장공동 외부로의 열손실을 평가하였다. 분석 결과, 종횡비가 증가함에 따라 공동 내 열성층화가 향상되는 경향을 보였으나, 종횡비 3-4 이상부터는 이러한 영향이 크지 않은 것으로 분석되었다. 저장용량이 작은 암반공동에 비해 용량이 큰 암반공동에서 상대적으로 긴 시간 동안 열성층화가 높게 유지되는 것으로 분석되었으나, 종횡비 증가에 따라 저장용량이 다른 공동들간의 성층화 차이가 줄어드는 경향을 나타냈다. 암반공동의 종횡비가 커질수록 공동의 표면적이 늘어나 종횡비의 증가에 따라 주변 암반으로의 열손실이 증가하는 경향을 보였으며, 단위 저장용량을 줄여 소규모 다중공동을 적용하는 경우, 총 저장용량이 동일한 단일공동에 비해 전체 열손실량이 증가하는 것으로 분석되었다.

EFFECTS OF NICARBAZIN AND HOT TEMPERATURE ON EVAPORATIVE WATER LOSS, ACID-BASE BALANCE, BODY TEMPERATURE AND CARBON DIOXIDE EXHALATION IN ADULT ROOSTERS

  • Lee, B.D.;Lee, S.K.;Hyun, W.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제7권1호
    • /
    • pp.97-101
    • /
    • 1994
  • Two experiments were conducted to study the effect of ambient temperature and nicarbazin on SCWL adult roosters. In Experiment 1, the effects of nicarbazin supplementation (125 ppm) on the water metabolism, blood acid-base balance; and rectal temperature of 16 birds in normal ($21^{\circ}C$) and hot ($35-36^{\circ}C$) temperature were investigated. In Experiment 2, the evaporative water loss and $CO_2$ exhalation from 8 birds were measured individually with an open-circuit gravimetric respiration apparatus in normal ($21^{\circ}C$) and hot ($33.5-34^{\circ}C$) temperature. The amount of water intake and evaporative water loss increased in birds under heat stress (HS). Nicarbazin exacerbated these effect in hot temperature. Also, nicarbazin decreased the blood $pCO_2$ and increased pH of HS birds. The rectal temperature of birds increased in hot temperature, and nicarbazin worsened this effect. The evaporative water loss, measured directly with respiration apparatus (Experiment 2), was increased in hot temperature. HS decreased the amount of $CO_2$ exhalation. Nicarbazin did not exert ant effect on either of these measurements, probably due to the limited duration (2 h) of the trial. The decrease in $CO_2$ exhalation by HS birds could be explained by reduced metabolic rate, which helps homeothermy of birds in hot temperature.

코발트기 자융성합금 코팅의 마모특성에 미치는 후열처리의 영향 (Effect of Post Heat Treatment on Wear Characteristics of Thermally Sprayed Co-based Self-flux Alloy Coating)

  • 이재홍;김영식
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.106-111
    • /
    • 2014
  • This article describes effect of post heat treatment on wear characteristics of thermally sprayed Co-based self-flux alloy coating. Co-based self-flux alloy coatings were deposited on steel substrates using a flame spray process. Post heat treatments were carried out at 800, 900, 1000 and $1100^{\circ}C$ for 30min in a vacuum chamber. For analysis of effect of post heat treatment on mechanical properties, wear test and hardness test were performed for post heat-treated coating specimen. Microstructures of heat treated coating layer and wear track were examined using SEM and EDS. Wear loss and hardness became lower with increasing post heat treatment temperature.

튜브뱅크 배열특성에 따른 전열특성변화 수치모사 (Numerical Simulation of Heat Transfer Characteristics of Tube Banks with Non-conventional Arrangement)

  • 전용두;남명환;구병수;이금배
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1129-1134
    • /
    • 2009
  • A numerical study has been conducted to investigate the effect of tube arrangement on the heat transfer and the pressure loss for cross flow heat exchangers. By defining a transverse deviation factor, ${\varepsilon}_t=l_T/S_T$, the flow pattern and the heat transfer characteristics are compared for selected ${\varepsilon}_t$ values of 0.0(in-lined), 0.1, 0.2, 0.3, 0.4, 0.5(staggered) by using a commercial software. Computational domain includes 1 pitch in the transverse direction and 5 pitches in the flow direction with due periodic boundary conditions.

  • PDF

암반공동 열에너지저장과 지상식 열에너지저장의 열손실 비교 분석 (A Comparative Study on Heat Loss in Rock Cavern Type and Above-Ground Type Thermal Energy Storages)

  • 박정욱;류동우;박도현;최병희;신중호;선우춘
    • 터널과지하공간
    • /
    • 제23권5호
    • /
    • pp.442-453
    • /
    • 2013
  • 본 연구에서는 FLAC3D를 이용해 대용량 고온 열에너지저장소가 암반공동과 지상에 위치하는 경우를 각각 모델링하고 운영기간 5년 동안의 비정상상태해석을 수행하여 저장소 외벽을 통한 열손실을 비교 분석하였다. 두 저장모델의 운영 조건 및 입력물성은 모두 동일하나, 암반공동 열에너지저장소는 주변 암반의 전도 열전달에 의해서만 열손실이 발생하고, 지상 저장소는 대기의 대류 열전달에 의해서 열손실이 발생하는 것으로 가정하였다. 열에너지의 반복적인 주입과 토출에 따른 저장온도의 변화를 고려하여 수치해석모델을 작성하였으며, 단열재 두께에 따른 열손실 특성을 함께 검토하였다. 해석 결과, 지상식 저장시설은 운영 기간이 경과하더라도 일정한 열손실률을 보이는 반면 암반공동 저장시설의 열손실률은 운영 초기 단계에서 급격히 감소하여 일정한 값으로 수렴하는 경향을 보였다. 이러한 열손실의 감소는 시간 경과에 따라 주변 암반의 온도가 상승함으로써 저장소외벽에서의 열유속이 감소하기 때문으로 판단할 수 있다. 운영 후 5년 경과 시 암반공동 열에너지저장소의 누적열손실량은 지상저장소에 비해 약 72.7%로 나타났으며, 암반공동 저장시설의 열손실 특성은 주변 암반의 히팅 효과로 인해 지상식 저장시설에 비해 단열재 두께에 대한 민감도 및 의존도가 상대적으로 낮은 것으로 분석되었다.

EVALUATION OF HEAT-FLUX DISTRIBUTION AT THE INNER AND OUTER REACTOR VESSEL WALLS UNDER THE IN-VESSEL RETENTION THROUGH EXTERNAL REACTOR VESSEL COOLING CONDITION

  • JUNG, JAEHOON;AN, SANG MO;HA, KWANG SOON;KIM, HWAN YEOL
    • Nuclear Engineering and Technology
    • /
    • 제47권1호
    • /
    • pp.66-73
    • /
    • 2015
  • Background: A numerical simulation was carried out to investigate the difference between internal and external heat-flux distributions at the reactor vessel wall under in-vessel retention through external reactor vessel cooling (IVR-ERVC). Methods: Total loss of feed water, station blackout, and large break loss of coolant accidents were selected as the severe accident scenarios, and a transient analysis using the element-birth-and-death technique was conducted to reflect the vessel erosion (vessel wall thickness change) effect. Results: It was found that the maximum heat flux at the focusing region was decreased at least 10% when considering the two-dimensional heat conduction at the reactor vessel wall. Conclusion: The results show that a higher thermal margin for the IVR-ERVC strategy can be achieved in the focusing region. In addition, sensitivity studies revealed that the heat flux and reactor vessel thickness are dominantly affected by the molten corium pool formation according to the accident scenario.

희박혼합기에 대한 다점점화의 점화능력 및 연소특성 (Ignitability and Combustion Characteristics of Lean Mixture by Multi-Point Ignition)

  • 이상준;나성오;이용균
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2607-2616
    • /
    • 1995
  • The influences of number of spark plug on ignitability, combustion characteristics and combustion promotion effect were examined to establish the design conception of spark ignition system for lean burn. Ignitability was increased remarkably by increasing of number of spark plug at combustion wall. Combustion duration was shortened and maximum combustion pressure was increased in accordance with increasing of spark plug number. Rate of overall combustion promotion considered of combustion duration and combustion pressure was 28% in two point ignition and 40% in four point ignition. It was verified that heat release, heat loss and combustion duration were affected by flame area, heat transfer area and maximum flame travel distance respectively.