• Title/Summary/Keyword: Heat Loss

Search Result 2,089, Processing Time 0.028 seconds

Pressure Loss and Heat Transfer Characteristics of the Glass Beads-Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • Kim, N.H.;Kim, J.S.;Lee, Y.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.550-560
    • /
    • 1996
  • Recently, fluidized bed heat exchangers with circulating liquid are widely used in a number of places-chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

Pressure Loss and Heat Transfer Characteristics of the Glass Bead - Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • 김내현;김정식;이윤표
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.121-131
    • /
    • 1996
  • Recently, circulating liquid fluidized bed heat exchangers are widely used in a number of places - chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. It also increased as the particle diameter increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

Optimization of a 3-D Thermally Asymmetric Rectangular Fin

  • Gang, Hyeong-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.11
    • /
    • pp.1541-1547
    • /
    • 2001
  • The non-dimensional fin length for optimum heat loss from a thermally asymmetric rectangular fin is represented as a function of the ratio of the bottom surface Biot number to the top surface Biot number, fin tip surface Biot number and the non-dimensional fin width. Optimum heat loss is taken as 98% of the maximum heat loss. For this analysis, three dimensional separation of variables method is used. Also, the relation between the ratio of the bottom surface Biot number to the top surface Biot number and the ratio of the right surface Biot number to the left surface Biot number is presented.

  • PDF

An Investigation of the Heat Loss Model for Predicting NO Concentration in the Downstream Region of Laminar CH4/Air Premixed Flames (층류 CH4/Air 예혼합화염의 하류영역에서 NO 농도 예측을 위한 열손실 모델의 검토)

  • Hwang, Cheol-Hong;Lee, Chang-Eon;Kum, Sung-Min;Lee, Kee-Man;Shin, Myung-Chul;Kim, Se-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.7
    • /
    • pp.486-494
    • /
    • 2009
  • One-dimensional modeling of $CH_4$/air premixed flame was conducted to validate the heat loss model and investigate NOx formation characteristics in the postflame region. The predicted temperature and NO concentration were compared to experimental data and previous heat loss model results using a constant gradient of temperature (100 K/cm). The following conclusions were drawn. In the heat loss model using steady-state heat transfer equation, the numerical results using the effective heat loss coefficient ($h_{eff}$) of $1.0\;W/m^2K$ were in very good agreement with the experiments in terms of temperature and NO concentration. On the other hand, the calculated values using the constant gradient of temperature (100 K/cm) were lower than that in the experiments. Although the effects of heat loss suppress NO production near the flame region, a significant difference in NO concentration was not found compared to that under adiabatic conditions. In the postflame region, however, there were considerable differences in NO emission index as well as the contribution of NO formation mechanisms. In particular, in the range of ${\phi}\;{\geq}\;0.8$, the prompt NO mechanism plays an important role in the NO reduction under the adiabatic condition. On the other hand, the mechanism contributes to the NO production under the heat loss conditions.

A Study on Rotor Eddy Current Loss and Thermal Analysis of PM Synchronous Generator for Wind Turbine (풍력터빈 PM형 동기발전기의 와전류손실과 열 해석에 관한 연구)

  • Choi, Man Soo;Chang, Young Hag;Park, Tae Sik;Jeong, Moon Seon;Moon, Chae Joo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1575-1581
    • /
    • 2014
  • In this paper, eddy current loss, iron loss and heat transfer of PMSG with 2,000kW capacities were analyzed for wind turbine. The PMSG with 3 split magnet was analyzed using ansoft maxwell commercial program and, generator was tested by Back to Back converter with no load condition at laboratory. Rotor surface temperature was measured by Pt100 sensors for investigating heat transfer from rotor to atmosphere. The simulation results shows 27.4kW eddy current loss in no load condition and 50.2kW eddy current loss in rated load condition with 3 split magnet, and also shows 4.3kW iron loss in no load condition and 7.3kW iron loss rated load condition. The heat transfer coefficient of convection between rotor surface and atmosphere was investigated by $9.6W/m^2{\cdot}K$. Therefore the heat transfer from rotor to atmosphere was about 17kW(54%) and from rotor to air-gap was about 14.6kW(46%) in no load condition. It is identified that the cooling system for stator have to include the 46% of iron loss, and heat dissipation structure of rotor surface have to be suggested and designed for efficiency improvement of generator.

Emission Characteristics of NOx and CO with Heat Loss Under High Efficiency Combustion Conditions of $CH_4$/Air Air Premixed Flame ($CH_4$/Air 예혼합화염의 고효율 연소조건에서 열손실에 따른 NOx 및 CO 배출특성)

  • Hyun, Seung-Ho;Hwang, Cheol-Hong;Lee, Chang-Eon;Kim, Se-Won;Jang, Gi-Hyun
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Emission characteristics of NOx and CO with heat loss under high efficiency combustion conditions of $CH_4$/Air prmixed flame were examined numerically using detailed-kinetic chemistry. The one-dimensional combustor length was fixed 5cm, and the equivalence ratio was varied from 0.75 to 0.95. To consider the effects of heat loss on NOx and CO formation, the radiative heat loss rate and combined heat loss rate of conductive and convective heat transfer are included. The following conclusions were drawn. In order to reduce the NOx and CO emission level simultaneously, the temperature of product gases must be reduced under 1,800K as soon as possible but kept over 1,300K during the residence time which is needed to converge CO to $CO_2$.

  • PDF

The Effect of Residence Time and Heat Loss on NOx Formation Characteristics in the Downstream Region of CH4/Air Premixed Flame (CH4/Air 예혼합화염의 하류영역에서 체류시간 및 열손실에 의한 NOx의 생성특성)

  • Hwang, Cheol-Hong;Hyun, Sung-Ho;Tak, Young-Jo;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.1 s.256
    • /
    • pp.99-108
    • /
    • 2007
  • In this study, the NOx formation characteristics of one-dimensional $CH_4$/Air premixed flame using detailed-kinetic chemistry are examined numerically. The combustor length and the amount of heat loss are varied to investigate the effect of residence time and heat loss on the NOx formation in a post-flame region. In the flame region, NO is mainly produced by the Prompt NO mechanism including $N_2$O-intermediate NO mechanism over all equivalence ratios. However, thermal NO mechanism is more important than Prompt NO mechanism in the post-flame region. In the case of adiabatic condition, the increase of combustor length causes the remarkable increase of NO emission at the exit due to the increase of residence time. On the other hand, NO reaches the equilibrium state in the vicinity of flame region, considering radiation and conduction heat losses. Furthermore the NO, in the case of $\phi$=1.2, is gradually reduced in the downstream region as the heat loss is increased. From these results, it can be concluded that the controls of residence time and heat loss in a combustor should be recognized as an important NOx reduction technology.

3D simulation of Heat transfer in MEMS-based microchannel (MEMS 로 제작된 마이크로 채널에서의 3 차원 열전달 해석)

  • Choi, Chi-Woong;Huh, Cheol;Kim, Dong-Eok;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1870-1875
    • /
    • 2007
  • The microchannel heat sink is promising heat dissipation method for high heat flux source. Contrary to conventional circular channel, MEMS based microchannel had rectangular or trapezoidal cross-sectional shape. In our study, we conducted three dimensional conjugate heat transfer calculation for rectangular shape microchannel. First, we simulated that channel was completely drained with known heating power. As a result we obtained calibration line, which indicates heat loss was function of temperature. Second, we simulated single phase heat transfer with various mass flux, 100-400 $kg/m^2s$. In conclusion, the single phase test verified that the present heat loss evaluation method is applicable to micro scale heat transfer devices. Heat fluxes from each side wall shows difference due to non-uniform heating. However those ratios were correlated with supplied total heat. Finally, we proposed effective area correction factor to evaluate appropriate heat flux.

  • PDF

Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange (온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.647-657
    • /
    • 2015
  • To investigate a method for calculation of the heating load for environmental designs of horticultural facilities, measurements of total heating load, infiltration rate, and floor heat flux in a large-scale plastic greenhouse were analyzed comparatively with the calculation results. Effects of ground heat exchange and infiltration loss on the greenhouse heating load were examined. The ranges of the indoor and outdoor temperatures were $13.3{\pm}1.2^{\circ}C$ and $-9.4{\sim}+7.2^{\circ}C$ respectively during the experimental period. It was confirmed that the outdoor temperatures were valid in the range of the design temperatures for the greenhouse heating design in Korea. Average infiltration rate of the experimental greenhouse measured by a gas tracer method was $0.245h^{-1}$. Applying a constant ventilation heat transfer coefficient to the covering area of the greenhouse was found to have a methodological problem in the case of various sizes of greenhouses. Thus, it was considered that the method of using the volume and the infiltration rate of greenhouses was reasonable for the infiltration loss. Floor heat flux measured in the center of the greenhouse tended to increase toward negative slightly according to the differences between indoor and outdoor temperature. By contrast, floor heat flux measured at the side of the greenhouse tended to increase greatly into plus according to the temperature differences. Based on the measured results, a new calculation method for ground heat exchange was developed by adopting the concept of heat loss through the perimeter of greenhouses. The developed method coincided closely with the experimental result. Average transmission heat loss was shown to be directly proportional to the differences between indoor and outdoor temperature, but the average overall heat transfer coefficient tended to decrease. Thus, in calculating the transmission heat loss, the overall heat transfer coefficient must be selected based on design conditions. The overall heat transfer coefficient of the experimental greenhouse averaged $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$, which represents a 60% heat savings rate compared with plastic greenhouses with a single covering. The total heating load included, transmission heat loss of 84.7~95.4%, infiltration loss of 4.4~9.5%, and ground heat exchange of -0.2~+6.3%. The transmission heat loss accounted for larger proportions in groups with low differences between indoor and outdoor temperature, whereas infiltration heat loss played the larger role in groups with high temperature differences. Ground heat exchange could either heighten or lessen the heating load, depending on the difference between indoor and outdoor temperature. Therefore, the selection of a reference temperature difference is important. Since infiltration loss takes on greater importance than ground heat exchange, measures for lessening the infiltration loss are required to conserve energy.

Change of the Warm Water Temperature for the Development of Smart Healthecare Bathing System (지능형 헬스케어 욕조시스템 개발을 위한 온수 온도변화)

  • Kim, Gi-Beom
    • Korean Chemical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.270-276
    • /
    • 2006
  • In this study, heat loss through free surface of water contained in bathtub due to conduction and evaporation has been analyzed. As a result of this study, a relational equation has been derived based on the basic theory of heat transfer to evaluate the performance of bath tubes. The derived equation was rational and quantitative. The major heat loss was found to be due to evaporation. Moreover, it has been found out that the speed of heat loss depends more on the humidity of the bathroom than the temperature of water contained in the bathtub. So, it is best to maintain the temperature of bathtub water to be between 41 to $45^{\circ}C$ and the humidity of bathroom to be 95%.