• Title/Summary/Keyword: Heat Load Analysis

Search Result 629, Processing Time 0.031 seconds

The Development of Methodology in order to consider Combined Heat and Power in the Basic Plan of Long Term Electricity Supply & Demand (전력수급기본계획에 열병합발전 설비 반영 방법론의 개발)

  • Kim, Yong-Ha;Kim, Mi-Ye;Woo, Sung-Min;Cho, Sung-Rin;Lim, Hyun-Sung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.570-575
    • /
    • 2006
  • This paper develops methodology in order to consider CHP(Combined Heat and Power) capacity in the Basic Plan of Long Term Electricity Supply & Demand. We develop generating cost of CHP considering electric and heat. Also we develop mixed load duration curve which includes the electric load and heat load and then apply CHP capacity to SCM(Screening Curve Method) considering CHP feature. Accordingly, it decide the optimal CHP capacity in the Basic Plan of Long Term Electricity Supply & Demand. Also, We perform the sensitivity analysis according to cost variation.

Thermohydrodynamic Lubrication Analysis of High Speed Journal Bearing Considering Variable Density and Specific Heat: Part II - Shaft Misalignment Effect (변화하는 밀도와 비열을 고려한 고속 저어널 베어링의 열유체 윤활해석 II-축 경사도 영향)

  • Chun, Sang-Myung;Jang, Si-Youl
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.305-310
    • /
    • 2001
  • Within some degree of journal misalignment, maximum pressure, maximum temperature, bearing load, friction and side leakage in high-speed journal bearing operation are examined under the condition of variable density and specific heat. The results are compared with the calculation results under the conditions of constant density and specific heat, and variable density and constant specific heat. It is found that the effects of variable density and specific heat on shaft misalignment are significant in determining the load capacity of a journal bearing operating at high speed.

  • PDF

Thermohydrodynamic Lubrication Analysis of High Speed Journal Bearing Considering Variable Density and Specific Heat: Part I - Shaft Speed Effect (변화하는 밀도와 비열을 고려한 고속 저어널 베어링의 열유체 윤활해석 I-축 속고영향)

  • Chun, Sang-Myung;Jang, Si-Youl
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.287-292
    • /
    • 2001
  • Under the condition of variable density and specific heat, maximum pressure, maximum temperature, bearing load, friction and side leakage in high-speed journal bearing operation are examined. The results are compared with the calculation results under the conditions of constant density and specific heat, and variable density and constant specific heat. It is found that the condition of variable density and specific heat play important roles in determining friction and load of journal bearing at high speed operation.

  • PDF

Theoretical Analysis of a Recuperative Refrigeration Dehumidifier (열회수 냉각 제습기의 이론적 해석)

  • Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.1
    • /
    • pp.48-54
    • /
    • 2014
  • A refrigeration dehumidifier with a recuperative heat exchanger is theoretically analyzed. The recuperative heat exchanger is located between the two air streams from and to the dehumidifying coil, and reduces the sensible heat load in dehumidification process. A simple model is developed to predict performance of the dehumidifier. The model predicts that the recuperative heat exchanger is effective especially in the low humidity condition, where the sensible heat load is relatively large. It is predicted that, by adopting a recuperative heat exchanger, a maximum 30~110% increase in COP is possible for indoor air at $27^{\circ}C$, and 40~60% relative humidity.

Performance Analysis of Heat Pump System for Greenhouse Cooling (온실 냉방을 위한 히트펌프의 성능 분석)

  • 윤용철;서원명;이석건
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.6
    • /
    • pp.120-126
    • /
    • 2001
  • This experiment was carried out to analyse on the cooling and dehumidifying effects of greenhouse by air-to-water heat pump system employing the air as cooling source. following results were obtained ; 1. The coefficients of performance (COP) of heat pump itself and total heat pump system were approximately 2.71~2.88 and 1.99~2.22, respectively. 2. The night-time cooling load of experimental greenhouse was 64.9 MJ/h, and the heat absorbed (cooling load) from heat pump system was 816.3~1,004.6 MJ/day. 3. The dehumidified moisture amount from experimental greenhouse was 7.0~15.0 kg/h. 4. The night time temperature of experimental greenhouse cooled by heat pump system could be maintained 4~6$^{\circ}C$ lower than that of control greenhouse which was almost equal to outside air temperature.

  • PDF

Heat Transfer Analysis of Hydropneumatic Suspension Unit By Finite Element Method (유한요소법을 이용한 유기압 현수장치의 열전달 해석)

  • Bae, Jing-Do;Cho, Jin-Rae;Lee, Hong-Woo;Song, Jung-In;Lee, Jin-Kyoo
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.531-536
    • /
    • 2004
  • In-arm type hydropeumatic suspension unit(ISU) is an equipment of armed tracked vehicle to absorb impact load and vibration from the irregular ground. During the operation of ISU, main piston moves forward and backward and oil flowing through damper transmits the external impact load to floating piston. Heat is generated in ISU by the oil pressure drop through the damper orifice and the friction between cylinder wall and two pistons. On the other hand, internal heat dissipatis outside via heat convection. Occurrence of high temperature can deteriorate durability of major components and basic function of ISU. And, it can cause fatal problem in the ISU life time and the sealing performance of piston rings. As well, the spring constant change of nitrogen gas that is caused by the temperature rise exerts the negative effect to the vehicle stability. Therefore, in this paper, we analyze the heat transfer analysis of the entire ISU unit, by finite element method, with the outside flow velocities 8m/s and 10m/s.

  • PDF

Empirical Results and Operational Cost Analysis of Geothermal Heat Pump System using Thermal Energy Storage in Cooling Season (축열식 지열원 히트펌프 시스템의 냉방기간 실증운전 결과 및 운영비용 분석)

  • Kim, Deukwon;Lee, Dongwon;Heo, Jaehyeok;Kim, Minhwi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.4
    • /
    • pp.167-174
    • /
    • 2018
  • The geothermal heat pump systems were installed for heating and cooling of public buildings in Jincheon Eco-friendly Energy town. The heat pump system was operated at night to save on operational costs, and the cold heat was stored in thermal energy storage (TES). In this study, the performance of geothermal heat pump systems with the TES during the summer season was analyzed, and the operational costs with and without the TES were compared. The electric chiller model was used to simulate a heat pump applied without the TES system. Electric rates of each system were measured to calculate operational costs. When the TES is used in the air conditioning system, the electric load (30.4 MWh) calculated in the daytime can move to off-peak load time, and the operational cost is reduced by 36~54%.

Thermal analysis of a thermal capacitor for the current lead cooling in conduction-cooled superconducting systems (전도냉각형 초전도시스템의 전류도입선 냉각을 위한 열커패시터의 열적해석)

  • 권기범;양형석;정은수;장호명
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.31-34
    • /
    • 2002
  • In this study, thermal analysis of a thermal capacitor, which is used to cool the current lead in conduction-cooled superconducting systems, was done. The temperature difference across a thermal capacitor was calculated by using heat conduction equation. Effect of heat load, total thickness, height and length of a thermal capacitor on the temperature difference were show. Using the results in this work, total thickness and heat height of a thermal capacitor can be determined for given heat load and given temperature difference. This work can be used practically in design for every superconduction system using a current lead.

  • PDF

Characteristics of Heat Transfer for Small-size Marine Diesel Engine (소형박용 디젤엔진의 전열특성)

  • 최준섭
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.36-42
    • /
    • 1996
  • Analysis of heat transfer on small-size Diesel engine is required for the development of high performance and efficiency engine. This basic study aims to establish heat transfer technique for marine Diesel engine. The main results from this study are as follows : 1) Overall engine heat transfer correlation of Re-Nu. 2) Radiant heat flux as fraction of total heat flux over the load range of several different Diesel engine. 3) Characteristics of heating curves on piston, cylinder liner and head. 4) Surface heat flux versus injection timing.

  • PDF

A Study on the Cooling Load of South and East Facing Apartment Houses (남향과 동향 집합주택의 냉방부하에 관한 연구)

  • 박근우;이경희
    • Journal of the Korean housing association
    • /
    • v.11 no.2
    • /
    • pp.129-137
    • /
    • 2000
  • This study is about the difference of South and East facing Cooling load of Apartment s Houses using Dynamic Heat-flow Calculation. Therefore, the purpose of this study is come in to use Material for the Thermal Environments of Apartment Houses. The results of the analysis are below. (1) For the peak load of degree hour; The highest is "I" unit and the next high load is H, F, E, C, B, G, D and A unit for the south facing Apartment houses. The higher load is "H" unit and the next high load is I, E, F, B, C, G, D, A Unit for the east facing Apartment houses. (2) For the total load of degree day; The highest load is "I" unit and the next high load is H, G, F, E, C, B, D and A Unit for the south facing Apartment houses. The highest load is "H" unit and the next high load is I, G, E, F, B, C, D, A Unit for the east facing Apartment houses. (3) For the total load of degree day; The highest load is "H" Unit for the east facing Apartment houses and the Lowest load is "A" Unit for the south facing Apartment houses.is "A" Unit for the south facing Apartment houses.nt houses.

  • PDF