• 제목/요약/키워드: Heat Generator

검색결과 589건 처리시간 0.021초

500W 급 마이크로 가스터빈을 위한 파형 휜을 가지는 리큐퍼레이터의 열성능 비교 (Comparison of the Thermal Performance of Recuperators with Corrugated Fins for a 500W Class Micro Gas Turbine Generator)

  • 도규형;김태훈;한용식;최병일;김명배
    • 한국군사과학기술학회지
    • /
    • 제16권6호
    • /
    • pp.847-856
    • /
    • 2013
  • In this study, thermal performance of recuperators with plain and offset strip fins is investigated to enhance the thermal efficiency of a micro gas turbine. Thermal cycle analysis is conducted to determine major design parameters of a single-pass counterflow recuperator. In order to evaluate the performance of the recuperator, the effectiveness and the pressure drop in the recuperators are chosen as the objective function and the design constraint, respectively. The optimized geometries for internal structure of the recuperators with plain and offset strip fins are obtained with varying the fin spacing and height. From the result, the recuperator with offset strip fins has better thermal performance when the fin spacing, s, is smaller than 1.45mm and the thermal performance of the recuperator with plain rectangular fins is higher than that with offset strip fins in the region of $s{\geq}1.45mm$. In addition, it is found that the entrance region effect and the longitudinal wall heat conduction effect should be taken into account for accurately predicting the thermal performance of the recuperators with both plain and offset strip fins.

저 손실 레디알 전력 결합기와 수냉 시스템을 이용한 고전력 증폭기 구현 (Implementation of a High Power Amplifier using Low Loss Radial Power Combiner and Water Cooling System)

  • 최성욱;김영
    • 한국항행학회논문지
    • /
    • 제22권4호
    • /
    • pp.319-324
    • /
    • 2018
  • 본 논문은 RF 전력 반도체를 사용한 고출력 전력증폭기를 구현한 것으로 기존의 플라즈마 발생 장치에 사용되는 마그네트론 방식의 고출력 증폭기 문제점인 낮은 효율과 짧은 수명, 유지 보수의 어려움 그리고 높은 운용비용 등을 개선하기 위한 것이다. 구현된 고출력 전력증폭기는 2.45 GHz ISM (industrial scientific medical) 대역에서 공간 결합방식을 이용한 저 손실, 고출력 레디알 결합기와 반도체로 3 kW급 출력을 얻기 위해서 300 W 급 전력 증폭기 16개의 증폭기로 구성되어 있다. 또한, 이 증폭기는 개별적인 증폭기에 수냉 방식의 구조를 적용하여 고출력에 따른 발열문제를 극복하였다. 소형 시스템으로 구성된 이 전력증폭기는 원하는 출력에서 50%의 높은 효율을 얻었다.

금속연료인 과립화붕소의 입도에 따른 연료과농 고체 추진제 특성 연구 (A Study of Fuel-rich Solid Propellant Characteristic for Boron-bead Particle Size)

  • 원종웅;최성한;이원복;김준형;황갑성;박복선
    • 한국추진공학회지
    • /
    • 제18권5호
    • /
    • pp.12-18
    • /
    • 2014
  • 공기흡입형 추진기관의 가스발생기에 사용하기 위한 연료과농(Fuel-rich) 고체 추진제의 특성에 대한 연구를 수행하였다. 일반적인 고체 추진제는 평균 60%이상의 산화제를 포함하는 데, 연료과농 고체 추진제를 개발히기 위해 산화제 함량을 30%내외로 낮추고 매우 높은 부피당 열량을 가지는 비정질 붕소를 입자화(Bead)하여 금속연료 함량을 증가시켜 고체 추진제의 제조 공정성 및 연소속도 특성을 확인하였다. 과립화붕소의 입도가 작을수록 추진제 제조 공정에서 초기 점도가 높아지고, 입도가 클수록 연소속도 및 압력지수가 증가하는 것을 확인할 수 있었다.

선박의 기관실에서의 연기 검출을 위한 LBP-GLCM 알고리즘에 관한 연구 (A Study on Smoke Detection using LBP and GLCM in Engine Room)

  • 박경민
    • 해양환경안전학회지
    • /
    • 제25권1호
    • /
    • pp.111-116
    • /
    • 2019
  • 선박의 기관실에서 사용하고 있는 화재 검출기는 연기나 열이 검출기에 도달해야 하지만 기관실의 공기 흐름은 기기의 사용유무에 따라 매우 유동적이기 때문에 상부에 설치된 검출기에 도달하기에는 많은 시간이 필요하다. 이러한 단점을 보완하기 위해 근래에는 영상을 기반으로 화재를 검지하는 연구가 이루어지고 있다. 영상기반의 연기 검지는 공기의 흐름에 영향을 받지 않으며 전송속도가 빠르기 때문에 화재의 초기 검지에 효율적이다. 본 연구는 기관실에서 연기 발생기로 발생시킨 연기의 확산모습을 녹화한 영상으로 실험을 수행하였다. 연기의 질감특징을 추출하는 LBP와 GLCM연산자를 사용하여 생성된 학습 데이터를 기계학습 분류기인 SVM으로 학습한 후 분류하여 검출 성능을 평가함으로서 연기가 상부에 설치되어 있는 검출기까지 상승하지 않더라도 영상기반으로 먼저 검지 가능함을 확인하였다.

수평형 HRSG의 탈질설비에서 암모니아 분사위치 변동에 따른 암모니아 유량비교 (Comparison of Ammonia Mass Flow Rate between Two Ammonia Injection Positions in DeNOx system of a Horizontal HRSG)

  • 박재현;유호선
    • 플랜트 저널
    • /
    • 제14권4호
    • /
    • pp.48-54
    • /
    • 2018
  • 발전설비에서의 질소산화물 배출 규제치가 강화됨에 따라 1990년대에 설치된 HRSG도 탈질설비를 추가로 설치해야 하는 상황이 되었다. 그러나 HRSG 내부에 촉매와 암모니아 분사장치 모두를 설치할 수 있는 공간이 없기 때문에 그 대안으로써 HRSG 내부에는 촉매만 설치하고 암모니아 분사장치는 가스터빈 배기덕트로 변동하여 설치하는 것을 검토하였다. 본 연구에서는 인천복합발전소를 대상으로, 암모니아 분사장치를 HRSG 중압 과열기 후단과 가스터빈 배기덕트에 설치하여 암모니아를 분사였을 때 대기 배출기준 8.5 ppm을 만족하는 암모니아 소비량을 각각 측정하였다. 연구결과 가스터빈 배기덕트 암모니아 분사방식이 HRSG 중압 과열기 후단 분사방식에 비해 소비량이 1.2배 정도 증가한 것으로 나타났다. 따라서 HRSG 수명 30년 운영을 고려한다면 HRSG 내부에 암모니아 분사장치를 설치할 수 없는 경우 가스터빈 배기덕트에 암모니아 분사장치를 설치하는 것이 추천된다.

  • PDF

Facile synthesis of nanostructured n-type SiGe alloys with enhanced thermoelectric performance using rapid solidification employing melt spinning followed by spark plasma sintering

  • Vishwakarma, Avinash;Bathula, Sivaiah;Chauhan, Nagendra S.;Bhardwaj, Ruchi;Gahtori, Bhasker;Srivastava, Avanish K.;Dhar, Ajay
    • Current Applied Physics
    • /
    • 제18권12호
    • /
    • pp.1540-1545
    • /
    • 2018
  • SiGe alloy is widely used thermoelectric materials for high temperature thermoelectric generator applications. However, its high thermoelectric performance has been thus far realized only in alloys synthesized employing mechanical alloying techniques, which are time-consuming and employ several materials processing steps. In the current study, for the first time, we report an enhanced thermoelectric figure-of-merit (ZT) ~ 1.1 at $900^{\circ}C$ in ntype $Si_{80}Ge_{20}$ nano-alloys, synthesized using a facile and up-scalable methodology consisting of rapid solidification at high optimized cooling rate ${\sim}3.4{\times}10^7K/s$, employing melt spinning followed by spark plasma sintering of the resulting nano-crystalline melt-spun ribbons. This enhancement in ZT > 20% over its bulk counterpart, owes its origin to the nano-crystalline microstructure formed at high cooling rates, which results in crystallite size ~7 nm leading to high density of grain boundaries, which scatter heat-carrying phonons. This abundant scattering resulted in a very low thermal conductivity ${\sim}2.1Wm^{-1}K^{-1}$, which corresponds to ~50% reduction over its bulk counterpart and is amongst the lowest reported thus far in n-type SiGe alloys. The synthesized samples were characterized using X-ray diffraction, scanning electron microscopy and transmission electron microscopy, based on which the enhancement in their thermoelectric performance has been discussed.

Conceptual design of small modular reactor driven by natural circulation and study of design characteristics using CFD & RELAP5 code

  • Kim, Mun Soo;Jeong, Yong Hoon
    • Nuclear Engineering and Technology
    • /
    • 제52권12호
    • /
    • pp.2743-2759
    • /
    • 2020
  • A detailed computational fluid dynamics (CFD) simulation analysis model was developed using ANSYS CFX 16.1 and analyzed to simulate the basic design and internal flow characteristics of a 180 MW small modular reactor (SMR) with a natural circulation flow system. To analyze the natural circulation phenomena without a pump for the initial flow generation inside the reactor, the flow characteristics were evaluated for each output assuming various initial powers relative to the critical condition. The eddy phenomenon and the flow imbalance phenomenon at each output were confirmed, and a flow leveling structure under the core was proposed for an optimization of the internal natural circulation flow. In the steady-state analysis, the temperature distribution and heat transfer speed at each position considering an increase in the output power of the core were calculated, and the conceptual design of the SMR had a sufficient thermal margin (31.4 K). A transient model with the output ranging from 0% to 100% was analyzed, and the obtained values were close to the Thot and Tcold temperature difference value estimated in the conceptual design of the SMR. The K-factor was calculated from the flow analysis data of the CFX model and applied to an analysis model in RELAP5/MOD3.3, the optimal analysis system code for nuclear power plants. The CFX analysis results and RELAP analysis results were evaluated in terms of the internal flow characteristics per core output. The two codes, which model the same nuclear power plant, have different flow analysis schemes but can be used complementarily. In particular, it will be useful to carry out detailed studies of the timing of the steam generator intervention when an SMR is activated. The thermal and hydraulic characteristics of the models that applied porous media to the core & steam generators and the models that embodied the entire detail shape were compared and analyzed. Although there were differences in the ability to analyze detailed flow characteristics at some low powers, it was confirmed that there was no significant difference in the thermal hydraulic characteristics' analysis of the SMR system's conceptual design.

중수로 증기발생기 다중 전열관 파단사고시 파단 전열관 수에 대한 영향 분석 (Influence Analysis on the Number of Ruptured SG u-tubes During mSGTR in CANDU-6 Plants)

  • 유선오;이경원
    • 한국압력기기공학회 논문집
    • /
    • 제18권2호
    • /
    • pp.37-42
    • /
    • 2022
  • An influence analysis on multiple steam generator tube rupture (mSGTR) followed by an unmitigated station blackout is performed to compare the plant responses according to the number of ruptured u-tubes under the assumption of a total of 10 ruptured u-tubes. In all calculation cases, the transient behaviour of major thermal-hydraulic parameters, such as the discharge flow rate through the ruptured u-tubes, reactor header pressure, and void fraction in the fuel channels is found to be overall similar to that of the base case having a single SG with 10 u-tubes ruptured. Additionally, as the conditions of low-flow coolant with high void fraction in the broken loop continued, causing the degradation of decay heat removal, the peak cladding temperature (PCT) would be expected to exceed the limit criteria for ensuring nuclear fuel integrity. However, despite the same total number of ruptured u-tubes, because of the different connection configuration between the SG and pressurizer, a difference is foud in time between the pressurizer low-level signal and reactor header low-pressure signal, affecting the time to trip the reactor and to reach the PCT limit. The present study is expected to provide the technical basis for the accident management strategy for mSGTR transient conditions of CANDU-6 plants.

해상풍력발전기 직격뢰 보호용 1등급 바리스터 개발 (Development of class I surge protection device for the protection of offshore wind turbines from direct lightning)

  • 이건희;박재현;정경진;강성만;최승규;우정민
    • 풍력에너지저널
    • /
    • 제14권4호
    • /
    • pp.50-56
    • /
    • 2023
  • With the abnormal weather phenomena caused by global warming, the frequency and intensity of lightning strikes are increasing, and lightning accidents are becoming one of the biggest causes of failures and accidents in offshore wind turbines. In order to secure generator operation reliability, effective and practical measures are needed to reduce lightning damage. Because offshore wind turbines are tall structures installed at sea, the possibility of direct lightning strikes is very high compared to other structures, and the role of surge protection devices to minimize damage to the electrical and electronic circuits inside the wind turbine is very important. In this study, a varistor, which is a key element for a class 1 surge protection device for direct lightning protection, was developed. The current density was improved by changing the varistor composition, and the distance between the electrode located on the varistor surface and the edge of the varistor was optimized through a simulation program to improve the fabrication process. Considering the combined effects of heat distribution, electric field distribution, and current density on the optimized varistor surface, silver electrodes were formed with a gap of 0.5 mm. The varistor developed in this study was confirmed to have an energy tolerance of 10/350 ㎲, 50kA, which is a representative direct lightning current waveform, and good protection characteristics with a limiting voltage of 2 kV or less.

Shell 석탄가스화 복합발전 시스템의 성능해석 연구 (Performance Analysis of Shell Coal Gasification Combined Cycle systems)

  • Kim, Jong-Jin;Park, Moung-Ho;Song, Kyu-So;Cho, Sang-Ki;Seo, Seok-Bin;Kim, Chong-Young
    • 에너지공학
    • /
    • 제6권1호
    • /
    • pp.104-113
    • /
    • 1997
  • 본 연구에서는 상용공정모사기인 ASPEN PLUS를 이용하여 건식탄공급, 산소사용 분류층 가스화기인 Shell가스화공정, 저온가스정제공정, GE MS7001FA가스터빈, 삼압.자연순환식 폐열회수보일러, 재열복수식 증기터빈 및 극저온 산소분리공정을 채용한 IGCC시스템에 대하여 성능해석 모델을 개발하고 시스템 성능해석을 위한 민감도분석을 수행하였다. 본 모델의 적정성은 설계조건에서 대상탄을 이용한 정상상태 성능해석 결과를 타 시뮬레이션 결과와 비교함으로서 검증하였다.$^{1)}$ . Illinois#6탄을 대상으로 수행한 시뮬레이션 결과는 투입되는 탄에 함유된 수분의 양이 증가함에 따라 가스화기의 온도가 감소하며, 회분 및 황이 많은 경우에 현열손실이 증가하여 시스템 효율이 감소하였다. 개발된 모델을 이용하여 가스화기의 운전압력, 증기/석탄비율 및 산소/석탄비율에 따르는 시스템의 민감도분석을 수행한 결과 운전압력 증가에 따라 가스화기 노내온도가 상승하며, 가연성가스(CO+H2) 생성율이 감소하였다. 증기/석탄비율 변화분석에서는 공급증기의 양을 변화시키면 가연성가스의 최고생성점이 보다 낮은 산소/석탄비율에서 나타남을 알 수 있었다. 또한 산소/석탄비율 변화분석에서는 증기/석탄 공급비율 0.2에서 산소/석탄 공급비율이 0.77인 경우에 가장 최적의 운전조건임을 알 수 있었다.

  • PDF