• Title/Summary/Keyword: Heat Generator

Search Result 589, Processing Time 0.023 seconds

Basic Design of High Pressure LOx Lines for a Liquid Rocket Engine (액체로켓엔진 액체산소 고압 배관부 기본설계)

  • Moon, Il-Yoon;Yoo, Jae-Han;Moon, In-Sang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.107-110
    • /
    • 2009
  • A basic design for a Technical Development Model (TDM) of liquid oxygen lines from the turbopump exit to the oxidizer valves of the combustion chamber and the gas generator was conducted to develop a turbopump-fed liquid rocket engine. The TDM is composed of straight lines, elbows, bellows, a branch, an orifice, flanges and a heat insulator. Materials were determined by consideration of operation conditions, weight constraint and manufacturing procedures. The size and the location of each component were determined by flow analysis of the required flowrate and the pressure loss. Basic designs of the components were conducted by consideration of the operating temperature and the maximum expectation operating pressure. The safety factors were evaluated by structural analysis of design of each component.

  • PDF

Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System Using H2O/LiBr+HO(CH2)3OH (H2O/LiBr+HO(CH2)3OH계 공냉형 이중효용 흡수식 냉방시스템의 사이클 해석)

  • Kwon, Oh-Kyung;Moon, Choon-Geun;Yoon, Jung-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.272-280
    • /
    • 1999
  • A cycle analysis was achieved to predict the characteristics by comprehensive modeling and simulation of an air-cooled, double-effect absorption system using a new $H_2O/LiBr+HO(CH_2)_3OH$ solution. The simulation results showed that the new working fluid may provide the crystallization limit 8% higher than the conventional $H_2O/LiBr$ solution. With a crystallization margin of 3wt%(weight%), the optimal solution distribution ratio was found in the range of 36 to 40%. Variation of cooling air Inlet temperature has a sensitive effect on the cooling COP and corrosion problem. The simulation of heat exchangers with UA value revealed that the absorber and the evaporator are relatively important for an air-cooled system compared with the condenser and the low temperature generator. The effect of cooling air flow rate, circulation weak solution flow rate and chilled water inlet temperature were also examined. The new working fluid may provide the COP approximately 5% higher than the conventional $H_2O/LiBr$ solution.

20kW Turbine Development for OTEC System (20kW OTEC 터빈 개발)

  • Han, Sangjo;Seo, JongBeom
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.38-43
    • /
    • 2014
  • In Ocean, the temperature of the deep sea water is always lower than that of the surface sea water. The temperature difference between the surface water and deep sea water is about $20^{\circ}C$. Based on thermodynamics, this temperature difference can be converted into mechanical power. The mechanical power can be converted to electricity through a generator. However, the temperature difference is relatively small compared with that of traditional steam turbines. It is difficult to apply the steam turbine technology for this small temperature difference directly. Therefore, the turbine for OTEC system using low temperature difference should be designed to meet the system requirement. The present study focuses on the development of the turbine for 20 kW OTEC system using R32. The paper includes the determination of working fluids, meridional design, turbine layout and 3D CFD results. With off-design points analysis, the full performance of 20kW OTEC turbine is investigated. Through the research, one stage radial type turbine with R32 as working fluid is successfully developed and can be applied to other high temperature heat source.

Recent Insights from the International Common-Cause Failure Data Exchange Project

  • Kreuser, Albert;Johanson, Gunnar
    • Nuclear Engineering and Technology
    • /
    • v.49 no.2
    • /
    • pp.327-334
    • /
    • 2017
  • Common-cause failure (CCF) events can significantly impact the availability of safety systems of nuclear power plants. For this reason, the International Common Cause Data Exchange (ICDE) project was initiated by several countries in 1994. Since 1997 it has been operated within the Organisation for Economic Co-operation and Development (OECD)/Nuclear Energy Agency (NEA) framework and has successfully been operated over six consecutive terms (the current term being 2015-2017). The ICDE project allows multiple countries to collaborate and exchange CCF data to enhance the quality of risk analyses, which include CCF modeling. As CCF events are typically rare, most countries do not experience enough CCF events to perform meaningful analyses. Data combined from several countries, however, have yielded sufficient data for more rigorous analyses. The ICDE project has meanwhile published 11 reports on the collection and analysis of CCF events of specific component types (centrifugal pumps, emergency diesel generators, motor operated valves, safety and relief valves, check valves, circuit breakers, level measurement, control rod drive assemblies, and heat exchangers) and two topical reports. This paper presents recent activities and lessons learnt from the data collection and the results of topical analysis on emergency diesel generator CCF impacting entire exposed population.

Manufacturing 2.25Cr-1Mo Steel In Hot Rolling Strip Mill (2.25% Cr-1%Mo 합금계 열연강판 제조기술)

  • 노태훈
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.390-398
    • /
    • 1999
  • The thermomechanical control process(in hot rolling strip mill) was employed to produce 2.25Cr-1Mo steel, which is to be construction material for the steam generator for power plant. Although the Conventional processes has been the primary means of producing the 2.25Cr-1Mo steel, an alternative method was used to meet the specification of ASTM heat treatment for A387-22-Classl using autotempering after coiling in hot rolling strip mill. The microstructures, tensile properties at various temperatures, and creep-rupture properties have been investigated to compare the properties with those of materials produced by the conventional process and to certify the application of the thermomechanical control process to an actual process of manufacturing 2.25-Cr-1Mo steel, this in turn, will reduce the cost of the process. About 14 to 34% glanular bainite (remainder proetectoid ferrite) formed in a coil, and this variety of volume fraction stems from the different cooling rates, which varies with position of the coil after coiling. Tensile testing from room temperature to 700$^{\circ}C$ indicated that strength increases with test temperature showing peaks at around 600$^{\circ}C$. Creep-rupture properties have been being investigated at the temperature of 500$^{\circ}C$ with 27.5, 32kg/$\textrm{mm}^2$ loads and have showed no rupture for over 1000 hours.

  • PDF

The Voltage-fed High Frequency Resonant Inverter Using Induction Heated Dry Steam Generator

  • Kim, Chil-Ryong;Lee, Jong-Kurl;Jung, Sang-Hwa;Mun, Sang-Pil;Kim, Sang-Don;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.415-418
    • /
    • 2008
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction-based fluid beating appliance using voltage-fed type scries capacitor-compensated load resonant high-frequency IGBT inverter with a phase-shifted PWM and a power factor correction schemes. Its operating characteristics in steady-state are illustrated including unique features and evaluated on the basis of its computer simulation and experimental results of 10kw breadboard appliance for hot water producer and superheated steamer. The promising cost effective inverter-fed boiler appliances for electromagnetic induction-heated type fluid-heating in the pipeline systems are proposed for induction-heated boiler, super heat steamer, high temperature water producer, hot gas producer and metal catalyst heating for exhaust gas cleaning in engine, which are more suitable and acceptable for industrial, chemical, and consumer energy utilization for household and business from a practical point of view.

  • PDF

A SIMPLIFIED METHOD TO PREDICT FRETTING-WEAR DAMAGE IN DOUBLE $90^{\circ}$ U-BEND TUBES

  • Choi, Seog-Nam;Yoon, Ki-Seok;Choi, Taek-Sang
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.616-621
    • /
    • 2003
  • Fluid-elastic instability is believed to be a cause of the large-amplitude vibration and resulting rapid wear of heat exchanger tubes when the flow velocity exceeds a critical value. For sub-critical flow velocities, the random turbulence excitation is the main mechanism to be considered in predicting the long-term wear of steam generator tubes. Since flow-induced interactions of the tubes with tube supports in the sub-critical flow velocity can cause a localized tube wear, tube movement in the clearance between the tube and tube support as well as the normal contact force on the tubes by fluid should be maintained as low as possible. A simplified method is used for predicting fretting-wear damage of the double $90^{\circ}$U-bend tubes. The approach employed is based on the straight single-span tube analytical model proposed by Connors, the linear structural dynamic theory of Appendix N-1300 to ASME Section III and the Archard's equation for adhesive wear. Results from the presented method show a similar trend compared with the field data. This method can be utilized to predict the fretting-wear of the double $90^{\circ}$U-bend tubes in steam generators.

  • PDF

Performance Evaluation of SCR System for Generator Engine on Training Ship KAYA (가야호 발전기용 SCR System의 성능 평가)

  • Jung, Suk-Ho;Jeong, Tae-Young;Hwang, Sung-Chul
    • Journal of Power System Engineering
    • /
    • v.19 no.6
    • /
    • pp.68-74
    • /
    • 2015
  • NOx emission has been controlled because it is a major cause of the acid rain and effects considerably on formation and destruction of ozone. A SCR system on diesel engine is necessary to clear TierIII, because IMO(International Maritime Organization) plans on tightening regulations to TierIII at $1^{st}$ January 2016. In this study, flow analysis was accomplished with ANSYS Fluent program so that the SCR system would be retrofitted in training ship KAYA and the temperature distributions of exhaust gas in SCR sytem were investigated after it was installed. As a result, it was confirmed that pressure and velocity distributions in SCR system were depended on pipe line shapes, then it was designed as the pressure was lower. The temperature differential between 1 and 3 point was $15^{\circ}C$ because of evaporative latent heat of urea and the temperature of 4 point after catalyst was increased by $5^{\circ}C$ than 3 point because of exothermic reaction.

Containment Closure Time Following the Loss of Shutdown Cooling Event of YGN Units 3&4

  • Seul, Kwang-Won;Bang, Young-Seok;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.68-79
    • /
    • 1999
  • The YGN Units 3&4 plant conditions during shutdown operation were reviewed to identify the possible event scenarios following the loss of shutdown cooling (SDC) event. For the five cases of typical reactor coolant system (RCS) configurations under the worst event sequence, such as unavailable secondary cooling and no RCS inventory makeup, the thermal hydraulic analyses were performed using the RELAP5/MOD3.2 code to investigate the plant behavior following the event. The thermal hydraulic analyses include the estimation of time to boil, time to core uncovery, and time to core heat up to determine the containment closure time to prevent the uncontrolled release of fission products to atmosphere. The result indicates that the containment closure is recommended to be achieved within 42 minutes after the loss of SDC for the steam generator (SG) inlet plenum manway open case or the large cold leg open case under the worst event sequence. The containment closure time is significantly dependent on the elevation and size of the opening and the SG secondary water level condition. It is also found that the containment closure needs to be initiated before the boiling time to ensure the survivability of the workers in the containment. These results will provide useful information to operators to cope with the loss of SDC event.

  • PDF

A Study for Optimal Design of the AIG to Improve the Performance of DeNOx Facilities Installed in Combined Cycle Plant (복합화력 탈질설비 성능향상을 위한 암모니아 주입 그리드의 최적설계 방안에 관한 연구)

  • Kim, Kwang-Chu;Park, Man-Heung;Yoon, Jun-Kyu;Lim, Jong-Han
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.811-820
    • /
    • 2007
  • A Study on the optimal design of the AIG(Ammonia Injection Grid) to improve the performance of DeNOx facilities in the HRSG(Heat Recovery Steam Generator) was performed using the CFD analysis. On the basis of the flow analysis results in the case that the AIG in the HRSG was not installed, the numerical analyses according to the positions of AIG, injection angles of nozzle and the control of ammonia injection quantity were carried out. The standard deviation according to factors was calculated for quantitative comparison. As the results, the AIG in the HRSG should be installed in the position that the uniform flow field shows through the exact flow analysis in the previous of the AIG design and installation. In the case the AIG has already been installed and non uniform flow distribution shows, it is recommended that flow correction device or KoNOx catalyst should be used. Otherwise, the control of ammonia injection angle or the ammonia injection quantity using the velocity profile analysis is demanded to accomplish the optimal performance.