• Title/Summary/Keyword: Heat Equation

Search Result 1,390, Processing Time 0.022 seconds

Measurement of Transient Heat Transfer Coefficient of In-cylinder Gas in the Hydrogen Fueled Engine with Dual Injection System (이중분사식 수소기관 연소실내 가스의 순간열전달계수의 측정)

  • Wei, Shin-Whan;Kim, Yun-Young;Lee, Jong-Tai
    • Journal of Hydrogen and New Energy
    • /
    • v.12 no.4
    • /
    • pp.267-275
    • /
    • 2001
  • To clear the differences of heat transfer coefficient of in-cylinder gas with fuel properties, the transient heat transfer coefficient of hydrogen gas is investigated by using the hydrogen fueled engine. The measured results were also compared with those of gasoline engine and several empirical equations. Transient heat transfer coefficients were determined by measurements of unsteady heat flux and instantaneous wall temperature in the cylinder head. As the main results, it is shown that transient heat transfer coefficients have remarkable differences according to fuel properties, and it's value for hydrogen engine is twice higher than that of gasoline engine. It means that equation of heat transfer coefficient that the effect of fuel properties is considered sufficiently, is needed to analyze or simulate the gas engine performance.

  • PDF

Flow and heat transfer analysis for the performance improvement of cross-flow fin-tube heat exchangers (에어컨 실외기용 휜-관 직교형 열교환기의 열, 유동 해석 및 휜 성능 개선을 위한 연구)

  • An C. S.;Choi D. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.183-189
    • /
    • 2004
  • The flow and the heat transfer about the cross-flow fin-tube heat exchanger in an out-door unit of a heat pump system has been numerically Investigated. Using the general purpose analysis code, FLUENT, the Navier-Stokes equations and the energy equation are solved for the three dimensional computation domain that encompasses multiple rows of the fin-tube. The temperature on the fin and tube surface is assumed constant but compensated later through the fin efficiency when predicting the heat-transfer rate. The contact resistance is also taken into consideration. The flow and temperature fields for a wide range of inlet velocity and fin-tube arrangements are examined and the results are presented in the paper. The details of the flow are very well captured and the heat transfer rate for a range of inlet velocity is in excellent agreement with the measured data. The flow solution provides the effective permeability and the inertial resistance factor of the heat exchanger if the exchanger were to be approximated by the porous medium. This information is essential in carrying out the global flow field calculation which, in turn, provides the inlet velocity lot the microscopic temperature-field calculation of the heat exchanger unit.

  • PDF

A new method to convert into seawater heat for the indoor air-conditioning resource (건물의 냉방을 위한 해수열 취득에 관한 실험적 연구)

  • Kim Ki-Cheol;Lee Seong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.8
    • /
    • pp.883-890
    • /
    • 2005
  • The industrial growth and the raised living quality have led to the massive energy consumption. As a result. the polluted environment and the limited amount of energy resources emerged as serious problems to be resolved in 21st century. Especially, in the case of Korea whose imported energy dependency rate is 98.2$\%$ in 2003 and constantly increasing every rear. more than 24$\%$ of overall energy consumption is for housing and commercial use. In order to cope with the shortage of natural energy resources, it is inevitable to develop alternative sustainable energy resources including seawater heat. so that they can replace existing resources. The heat transfer air velocity 3.5 m/s is proper to consideration with the body the pipe size 200A is more suitable than look due to the air velocity quantify and the ratio of pipe surface area. And the error between experimental data with simulation is below 5.34$\%$ so the suggested equation for calculating heat transfer capacity can be used. Therefore out of many methods utilizing seawater heat. this work Presents the efficiency of using sea water heat as a resource for air-conditioners which can be converted from the outside air through the air-to-heat conversion tube . Consequently. this method provides pretty reasonable energy efficiency.

A Study on the Characteristics of Evaporative Heat Transfer for Carbon Dioxide in a Horizontal Tube (수평원관 내 이산화탄소의 증발열전달 특성 연구)

  • Cho, E.S.;Yoon, S.H.;Kim, M.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.104-107
    • /
    • 2000
  • Evaporative heat transfer characteristics of carbon dioxide has been investigated. Experiment has been carried out for seamless stainless steel tube with outer diameter of 9.55 mm and inner diameter of 7.75 mm. Direct heating method is used for supplying heat to the refrigerant was uniformly heated by electric current which was applied to the tube wall. The saturation temperature of refrigerant is calculated from the measured saturation pressure by using an equation of state. Inner wall temperature was calculated from measured outer wall temperature, accounting for heat generation in the tube and heat conduction through the tube wall. Mass Quality of refrigerant was calculated by considering energy balance in the preheater and the test section. Heat fluxes were set at 12, 16, 20, 23, and $27kW/m^2$, mass fluxes were controlled at 212, 318, 424, and $530 kg/m^2s$, and saturation temperature of refrigerant were adjusted at 0, 3.4, 6.7 and $10.5^{\circ}C$. From this study, heat transfer coefficients of carbon dioxide have been provided with respect to quality for several mass fluxes, heat fluxes. Finally, the experimental results in this study are compared with the correaltion by Gungor and Winterton(1987).

  • PDF

2D Heat Transfer Model for the Prediction of Temperature of Slab in a Direct-Fired Reheating Furnace (가열로 내 슬랩의 온도 예측을 위한 2차원 열전달 모델)

  • Lee Dong-Eun;Park Hae-Doo;Kim Man-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.950-956
    • /
    • 2006
  • A mathematical heat transfer model for the prediction of heat flux on the slab surface and temperature distribution in the slab has been developed by considering the thermal radiation in the furnace and transient conduction governing equations in the slab, respectively. The furnace is modeled as radiating medium with spatially varying temperature and constant absorption coefficient. The slab is moved with constant speed through non-firing, charging, preheating, heating, and soaking zones in the furnace. Radiative heat flux which is calculated from the radiative heat exchange within the furnace modeled using the FVM by considering the effect of furnace wall, slab, and combustion gases is applied as the boundary condition of the transient conduction equation of the slab. Heat transfer characteristics and temperature behavior of the slab is investigated by changing such parameters as absorption coefficient and emissivity of the slab. Comparison with the experimental work shows that the present heat transfer model works well for the prediction of thermal behavior of the slab in the reheating furnace.

Analysis of the Efficiency of Improved Bubble Sheet for Heat Curing in Cold Weather

  • Choi, Hyun-Kyu;Son, Myung-Sik;Han, Cheon-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.1
    • /
    • pp.38-47
    • /
    • 2013
  • When building with concrete in cold weather, an insulation method of heat curing must be determined, and a holistic curing plan that considers the characteristics of structures, the heat loss coefficient of a curing sheet, the joint condition of the curing materials and the quantity of heat produced by a heating apparatus is an essential prerequisite for protection against early frost damage. But on a number of national construction sites, there have been serious problems in cold weather concreting due to the unreliability of the information obtained from practical experience. In the construction field in Japan, there is a specification for heat curing prepared by Japanese Architectural Society, which provides an equation for calculating heat quantity. It is also necessary to adopt a detailed specification for a standard heat curing method that is applicable to all national construction sites. In this study, the effect of bubble sheets on the economic feasibility of cold weather concrete is investigated through a comparison with the blue sheets commonly prescribed in national construction sites. In conclusion, this study found that bubble sheets had the effect of reducing the cost of curing materials and the fuel cost consumed by a heating apparatus, compared to the use of blue sheets.

A Study on the Comparison of the Combustion Characteristics between a Small HSDI and an IDI Diesel Engine by Advanced One-zone Heat Release Analysis (개선된 단일영역 열발생량 계산법을 사용한 소형 HSDI와 IDI엔진의 연소특성 비교에 관한 연구)

  • Lee, Suk-Young;Jeong, Ku-Seop;Jeon, Chung-Hwan;Jang, Young-June
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.6
    • /
    • pp.46-53
    • /
    • 2004
  • Heat release analysis is a very important method for understanding the combustion phenomena inside an engine cylinder. In this study, one-zone heat release analysis was used with the measured cylinder pressures of a HSDI(high speed direct injection) and IDI(indirect injection) diesel engines, Those have benefits of simple equation, fast speed, reliability. The objective of the study is to compare the combustion characteristics between a HSDI and an IDI. The result shoes that the maximum heat release rate of a HSDI is higher than that of an IDI because of long ignition delay period. The heat release curve of an IDI is more linear than that of a HSDI, thus is similiar to that of a SI engine. The combustion efficiency of a HSDI is higher than that of an IDI because of the smaller heat transfer loss of a HSDI. There is a suggestion here that an IDI engine has broad heat transfer area which include two combustion chambers, the connection passage of combustion chambers, etc.

Convective Boiling Two-phase Flow in Trapezoidal Microchannels : Part 2-Heat Transfer Characteristics (사다리꼴 미세유로의 대류비등 2상유동 : 2부-열전달 특성)

  • Kim, Byong-Joo;Kim, Geon-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.718-725
    • /
    • 2011
  • Characteristics of flow boiling heat transfer in microchannels were investigated experimentally. The microchannels consisted of 9 parallel trapezoidal channels with each channel having 205 ${\mu}m$ of bottom width, 800 ${\mu}m$ of depth, $3.6^{\circ}$ of sidewall angle, and 7 cm of length. Tests were performed with R113 over a mass velocity range of 150~920 $kg/m^2s$, heat flux of 10~100 $kW/m^2$ and inlet pressures of 105~195 kPa. Flow boiling heat transfer coefficient in microchannels was found to be dominated by heat-flux. However the effect of mass velocity was not significant. Contrary to macrochannel trends, the heat transfer coefficient was shown to decrease with increasing thermodynamic equilibrium quality. A new correlation suitable for predicting flow boiling heat transfer coefficient was developed based on the laminar single-phase heat transfer coefficient and the nucleate boiling dominant equation. Comparison with the experimental data showed good agreement.

A Study on the Comparison of the Combustion Characteristics among an IDI, a HSDI Diesel Engine and a SI Engine using One-zone Heat Release Analysis (단일영역 열발생량 계산법을 사용한 IDI, HSDI 디젤엔진과 SI엔진의 연소특성 비교에 관한 연구)

  • Lee Sukyoung;Jeong Kuseob;Jeon Chunghwan;Chang Yongjune
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.21-30
    • /
    • 2005
  • Heat release analysis is a very importent method in understanding the combustion phenomena inside an engine cylinder. In this study, one-zone heat release analysis was used with the mesured cylinder pressures of an IDI(indirect injection), a HSDI(high speed direct injection) and a SI(spark ignition) engine. It has benefits of simple equation, fast speed, reliability. The object of the study is to compare the combustion characteristics among an IDI, a HSDI and SI engine. Result of analysis, the maximum heat release rate of a HSDI is higher than an IDI because of long ignition delay period. The heat release curve of a IDI is more linear than an HSDI, so the combustion characteristics of a IDI is similiar to that of an SI engine. There is a suggestion here that the combustion efficiency of a HSDI is highest of that of all engines because of the smallest heat transfer loss of all engines.