• Title/Summary/Keyword: Heat Balance

Search Result 657, Processing Time 0.029 seconds

Analysis on the Energy Balance and Performance Variation of the Power Plant by using the Heavy Residual Oil (중질잔사유 적용시 발전플랜트의 에너지 수지 및 성능 변화 분석)

  • Park, Ho-Young;Kim, Tae-Hyung
    • Journal of Energy Engineering
    • /
    • v.17 no.2
    • /
    • pp.107-115
    • /
    • 2008
  • The numerical analysis of energy and material balance, and plant performance has been carried out when applying the heavy residual oil instead of heavy oil to the existing heavy oil power station. The performance analysis model has been constructed for A heavy oil power station in Korea, and the modeling results were compared with the design data in order to ensure the validity of the model, and further compared with the plant operation data. With the heavy residual oil, the simulation gave 315 MW in power output, which is higher than that of the heavy oil combustion, but the plant efficiency turned out to be lower. The sensitivity analysis of heat rate for the changes in cooling water and ambient temperature, flue gas recirculation and power output has provided valuable information for the optimal operation of the power station.

Analysis of a Double Pipe Heat Exchanger for Waste Solvent Recovery (폐용제 회수용 이중관형 열교환기 특성 해석)

  • 구재현;이재근
    • Resources Recycling
    • /
    • v.9 no.3
    • /
    • pp.13-21
    • /
    • 2000
  • This study describes to analyze the heat transfer characteristics of waste solvent recovery system using a double pipe heat exchanger heating solvent by the hot oil. The solvent recovery system consists of the feeding pump, the double pipe heat exchanger, the vacuum spray chamber, and the condenser. A double pipe heat exchanger consists of the first section to conduct the heating of solvent to the thermal saturated point and the second section to evaporate the saturated solvent. The heat transfer area for vaporization of water, benzene and alkylbenzene was predicted by the heat balance modelling and experimentally measured from the temperature distribution as a function of solvent flow rate and heating temperature. The required heat transfer area for vaporization was increased with increasing solvent flow rates and with decreasing heating temperatures due to decreased quantity of transferred heat per the unit area. Theoretical modelling of the heat transfer area for solvents vaporization in the pipe showed good agreement with experimental results. Results showed to be suitable for the waste solvent recovery using a double pipe heat exchanger.

  • PDF

A study on the evaluation of lower heating value using heat balance method in industrial waste incineration facilities (열정산방법을 이용한 사업장폐기물 소각시설의 저위발열량 분석·평가 연구)

  • Ko, Youngjae;Kang, Jun-Gu;Kwon, Young-Hyun;Yoo, Ha-Nyoung;Kwon, Jun-Hwa;Jang, Mi-Jeong;Jeon, Tae-Wan;Shin, Sun-Kyoung
    • Analytical Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.31-38
    • /
    • 2018
  • The energy recovery rate estimation method proposed through the Waste Control Act does not take into account the energy used in practice. In addition, the method for measuring a lower heating value, which is the main factor of the energy recovery rate, was carried out through a small sampling amount, and thus the representative value of the waste was not reflected. With the revised estimation method (Notification No. 2015-215 of the Ministry of Environment), the energy recovery rate should be estimated based on the actual amount of energy used, and a heat balance method was proposed as a way to estimate the lower heating value. In this study, the lower heating value was estimated for seven industrial waste incineration facilities according to the revised estimation method. All data used in the estimations were achieved from measurement instruments applied to each of the incinerators and through direct measurements taken by the operators for the purposes of calculation. As a result, the lower heating value was estimated to be about 3,404.7 kcal/kg for the seven industrial waste incineration facilities.

Effects of Heat Treatment on the Nutritional Quality of Milk. IV. Effects of Heat Treatment on the Physical and Nutritional Properties of Milk Protein (우유의 열처리가 우유품질과 영양가에 미치는 영향: IV. 우유의 열처리가 우유단백질의 이화학적 성질과 영양에 미치는 영향)

  • Jung, Jong-Wook;Jung, Jiyoon;Mim, Tae Sun;Oh, Sejong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.35 no.4
    • /
    • pp.270-285
    • /
    • 2017
  • Among milk proteins, caseins are not subjected to chemical changes during heat treatment of milk; however, whey proteins are partially denatured following heat treatment. The degree of whey protein denaturation by heat treatment is decreased in the order of high temperature short time (HTST) > low temperature long time (LTLT) > direct-ultra-high temperature (UHT) > indirect-UHT. As a result of heat treatment, several changes, including variations in milk nitrogen, interactions between beta-lactoglobulin and k-casein, variations in calcium sulfate and casein micelle size, and delay of milk coagulation by chymosin action, were observed. Lysine, an important essential amino acid found in milk, was partially inactivated during heat treatment. Therefore, the available amount of lysine decreased slightly (1~4% decrease) after heat treatment, However, the influence of heat treatment on the nutritional value of milk was negligible. Nutritional value and nitrogen balance did not differ significantly between UHT and LTLT in milk. In conclusion, our results showed that heat treatment of milk did not alter protein quality. Whey proteins denatured to a limited extent during the heat treatment process, and the nutritional value and protein quality were unaffected by heat treatment.

A Study on Cross Type Heat Exchanger Using Element Method (직교류형 열교환기에 대한 엘리멘트를 이용한 열정산 방법에 관한 연구)

  • Jung, H.H.;Shin, H.T.;Kim, K.H.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.2
    • /
    • pp.114-122
    • /
    • 1991
  • A thermal analysis method taking into account energy balance in each elements of heat exchanger was introduced. This method has a merit in predicting the temperature field over the heat exchanger in detail. To verify this method, the results were compared with the published ones. The thermal analysis of the radiator in vehicles was also conducted and the results were compared with experimental ones. It is concluded that this method can be used in thermal analysis with relatively small error. When the velocity profile of inlet air is not uniform, the outlet temperature of cooling water is higher than that of uniform velocity profile.

  • PDF

On the Thermal Effect of Vegetation Canopy to the Surface Sublayer Environment (Vegetation Canopy의 접지층 환경에 대한 열적 영향 제2부 : 벼 식피층 관측)

  • 진병화;황수진
    • Journal of Environmental Science International
    • /
    • v.8 no.2
    • /
    • pp.151-154
    • /
    • 1999
  • To verify the accuracy of the numerical experiment of Part I, measurements at the matured rice canopy located around Junam reservoir were performed at August 14, 1995. According to the measured data, the foliage temperature recorded the highest value, and the ground temperature was the lowest around noon, and these results coincided with those of the numerical experiment using the combined model of Part I. From the estimation using measured data, the maximum value of the latent heat flux was 380$Wm^2$, the highest value among energy balance terms, and the energy redistribution ratio of the latent heat flux was averaged as 0.5, the highest values among redistribution ratios. These results are the same as those of the numerical experiment in tendency, but they reveals a little lower in the absolute values than those from the numerical experiment.

  • PDF

A Numerical Study of Heat and Mass Transfer Phenomena for Thermal Protection Material (열보호재료의 열 및 물질전달 현상에 관한 수치해석적 연구)

  • Kim, Jung-Hoon;Kwon, Chang-Oh;Seo, Jeong-Il;Bai, Cheol-Ho;Song, Dong-Joo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1201-1212
    • /
    • 1999
  • A numerical analysis is performed to predict the thermal response and ablation rate for charring or non-charring material which is designed to be used as thermal protection system (TPS). The numerical program composed of in-depth energy balance equation and the aerotherm chemical equilibrium (ACE) program. The ACE program calculates various thermochemical state from ablation products. The developed numerical program is verified by comparing the reported results from literature. The sensitivity tests for input parameters are performed. The thermal behavior of ablating material is mainly affected by density of ablating material, convective heat transfer coefficient and recovery enthalpy of flow field.

Intermittent Heating and Cooling Load Calculation Method -Comparing with ISO 13790

  • Lee, Sang-Hoon
    • Architectural research
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • College of Architecture, Georgia Institute of Technology, Atlanta, GA, US Abstract The intermittent heating and cooling energy need calculation of the ISO 13790 monthly method was examined. The current ISO 13790 method applies a reduction factor to the continuous heating and cooling need calculation result to derive the intermittent heating and cooling for each month. This paper proposes a method for the intermittent energy need calculation based on the internal mean temperature calculation. The internal temperature calculation procedure was introduced considering the heat-balance taking into account of heat gain, heat loss, and thermal inertia for reduced heating and cooling period. Then, the calculated internal mean temperature was used for the intermittent heating and cooling energy need calculation. The calculation results from the proposed method were compared to the current ISO 13790 method and validated with a dynamic simulation using EnergyPlus. The study indicates that the intermittent heating and cooling energy need calculation method using the proposed model improves transparency of the current ISO 13790 method and draws more rational outcomes in the monthly heating and cooling energy need calculation.

Thermodynamic Analysis of a Double-Effect Absorption Heating System Using Water-LiBr-LiSCN Solution with Solar Evaporator Heating (증발기 열원으로 태양열을 이용하며 LiSCN+LiBr 수용액을 사용하는 흡수식 2중효용 난방시스템의 열역학적 해석)

  • Won, Seung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.3
    • /
    • pp.27-35
    • /
    • 2005
  • In this paper, a thermodynamic analysis was performed to provide design data for a double-effect absorption heating system with water-LiBr-LiSCN mixture which utilizes solar energy as evaporator heat source. In addition, a comparative study of the water-LiBr-LiSCN mixture against the water-LiBr pair was conducted by a computer simulation. The computer simulation is based on mass, material and heat balance equations for each part of the system. Coefficients of performance and flow ratios for effects of different operating temperatures are investigated. It is found that the heating COP is higher for the water-LiBr-LiSCN mixture than for the water-LiBr pair, and FR is lower for the former.

Experimental Investigation of Thermal Stress Cracks in Mechanical Face Seals (기계평면시일의 열응력 크랙에 관한 실험적 연구)

  • 김청균
    • Tribology and Lubricants
    • /
    • v.12 no.3
    • /
    • pp.79-84
    • /
    • 1996
  • One of the greatest dangers in mechanical face seals is the formation of heat checking and thermal stress cracks on the sliding surfaces. These thermal distortions due to non-uniform heating lead to increase the leakage of the sealed fluids and wear, and with balance of the seal can cause the seal faces to part. In this study heat checking and thermal stress cracks are investigated experimentally. These thermal distortions are explained using the thermal models of the conatct geometries between the seal ring and the seal seat. To overcome these thermal problems, the thermohydrodynamic seal is presented. The newly developed mechanical seal may substantially reduce the friction torque, frictional heating which causes heat checking and thermal stress cracks, and wear.