• Title/Summary/Keyword: Heart valves

Search Result 234, Processing Time 0.023 seconds

Clinical Experience of Cardiovascular Surgery : A Report Of 2032 Cases (심장 혈관질환 2032 수술 례 보고)

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.375-384
    • /
    • 1980
  • Since 1958 up to the end of October 31, 1980, 2032 cases of cardiovascular lesions were operated, including 1225 open heart surgery and 354 valve replacement patients. There were 1271 Congenital anomaly cases and 761 acquired lesions including 149 vascular lesions. Among 1~271 congenital malformations 819 cases belong to acyanotic and 452 to cyanotic group. Over all mortality was 11.1 %, consisting of 12.4% for congenital and 8.9% for acquired lesions. Mortality for 1225 open heart surgery cases was 15% and 13.8% for various 354 valve replacement cases. In most of the open heart surgery cases Shiley oxygenator was utilized and Ionescu-Shiley bovine pericardial xenograft bioprosthesis**** valves were used mainly for valve replacement.

  • PDF

의공산업의 현황과 전망

  • 고영환
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.91-93
    • /
    • 1989
  • We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate.

  • PDF

Hemodynamic Evaluation of Monoleaflet Polymer Valve (단엽식 고분자판막의 혈역학적 성능평가)

  • 김상현;장병철
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.61-66
    • /
    • 1995
  • We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane. To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medicals prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volllme and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate.

  • PDF

Clinical Evaluation of Multiple Valve Replacement (심장다판치환술의 임상적 고찰)

  • 오상기
    • Journal of Chest Surgery
    • /
    • v.33 no.2
    • /
    • pp.160-166
    • /
    • 2000
  • Background: The purpose of this study is to evaluate and analyze the surgical results in patients undergoing operations for multiple for multiple valvular heart diseases. Material and method: From April 1982 to June 1997 multiple valve replacement was performed in 150 patients mitral and aortic valve replacement were done in 135 patients mitral and tricuspid valve replacements in 10 patients triple replacements in 4 patients and aortic and tricuspid valve replacement in 1 patient. Of the valves implanted 157 were St. Jude 104 Duromedics 20 Carpenter-Edwards 6 Bjork-Shiley 6 Ionescu-Shiley and 2 Medtronics. Result: The hospital mortality rate was 10.7% (16/150) and the late mortality rate was 7.2% (8/134) The mortality rate was high in early operative period but decreased with time. The causes of death were low cardiac output in 9 sudden death in 3 congestive heart failure in 3 bleeding in 2 cerebral thrombosis in 1 leukemia in 1 multiorgan failure in 1 and so on . The actuarial survival rate excluding operative death was 83.1% at 15 years. Conclusion: With a follow-up now extending to 15 years the multiple valve replacement continues to be reliable procedure with relatively low mortality and morbidity.

  • PDF

Application of Homograft in the Surgical Correction of Complex Congenital Cardiac Malformations (선천성 복잡 심기형 환자의 외과적 교정술시 동종이식편의 적용에 관한 연구)

  • 지현근
    • Journal of Chest Surgery
    • /
    • v.28 no.11
    • /
    • pp.1038-1044
    • /
    • 1995
  • We have been used cryopreserved homograft valves for right ventricular outflow tract[RVOT reconstruction since November 1993. The homograft valves were harvested from the hearts of brain dead patients or hearts of transplant recipients. There were 12 male and 10 female patients. Their ages ranged from 5 months to 13 years[mean age,39.2 $\pm$ 37.4 months and the weight ranged from 5 to 48kg [mean weight, 13.7$\pm$ 9. l kg . The diagnoses included pulmonary atresia with ventricular septal defect [n=14 , tetralogy of Fallot[n=4 , truncus arteriosus[n=3 , and double outlet right ventricle with pulmonic stenosis[n=l .Monocuspid homograft patches were used for RVOT widening or REV[reparation l`etage ventriculaire operations in 4 patients. We also used homograft as valved conduits for RVOT reconstruction in 17 patients and left ventricular outflow tract reconstruction in anatomically corrected transposition in 1 patient. Among them size-reducing technique [converting a tricuspid valved conduit into a bicuspid valved conduit were applied to six patients for the correction of size mismatching. The mean follow-up period was 10.6 $\pm$ 5.4 months. There was one operative death[4.5% due to bleeding and one reoperation for removal of vegetation on the homograft leaflet. Postoperative echocardiography documented no significant homograft insufficiency and RVOT obstructions.In short-term, the homograft valves provide excellent hemodynamic characteristics, even though further studies are necessary to evaluate the long-term results.

  • PDF

Heart Valve Stenosis Region Detection Algorithm on Heart Sounds (심음에서의 심장판막협착 영역 검출 알고리듬)

  • Lee, G.H.;Lee, Y.J.;Kim, M.N.
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.11
    • /
    • pp.1330-1340
    • /
    • 2012
  • In this paper, a new algorithm is proposed for the heart valves stenosis region detection using heart sounds. Many researches for detecting primary components or removing heart murmurs have been studied, but their performances are degraded at abnormal heart sounds such as aortic stenosis and mitral stenosis because of large heart murmurs. In this paper, heart murmur detection method is proposed based on noise intensity function. The proposed noise intensity function detect the primary components S1, S2, then set session up using S1, S2. And then noise intensity function was computed using autocorrelation value of each session. The proposed noise intensity function estimated noise intensity of each sessions and detected heart murmurs. According to simulation results, the proposed algorithm has better performance than former study for detecting heart valve stenosis region.

Clinical Analysis of Open Heart Surgery -Review of 450 Cases (개심술 450례의 임상적 고찰)

  • 이서원;이계선
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.770-779
    • /
    • 1997
  • From Feb. 1985 to Aug. 1996, 450 patients underwent open heart surgery with hypothermic cardiopulmonary bypass. In 450 cases of open heart surgery, 222 cases(49.3%) were congenital heart diseases and 228 cases(5 .7%) were acquired heart diseases. In 222 cases of congenital heart diseases, there were 201 cases of acyanotic heart disease and 21 cases of cyanotic heart diseases. Among the 228 cases of acquired heart diseases, most cases were valvular heart diseases in which 206 valves were implanted. There were 32 cases of ischemic heart disease and the average graft anastomoses were 2.37 sites per operation. The operative mortality of congenital and acquired disease was 9.0% and 10.l% respectively and then overall mortality rate was 9.6% .

  • PDF

Numerical Study on the Pulsatile Blood Flow through a Bileaflet Mechanical Heart Valve and Leaflet Behavior Using Fluid-Structure Interaction (FSI) Technique (유체-고체 상호작용 (FSI)기법을 이용한 이엽기계식 인공심장판막을 지나는 혈액유동과 판첨거동에 관한 수치해석적 연구)

  • Choi, Choeng-Ryul;Kim, Chang-Nyung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.3 s.24
    • /
    • pp.14-22
    • /
    • 2004
  • Bileaflet mechanical valves have the complications such as hemolysis and thromboembolism, leaflet damage, and leaflet break. These complications are related with the fluid velocity and shear stress characteristics of mechanical heart valves. The first aim of the current study is to introduce fluid-structure interaction method for calculation of unsteady and three-dimensional blood flow through bileaflet valve and leaflet behavior interacted with its flow, and to overcome the shortness of the previous studies, where the leaflet motion has been ignored or simplified, by using FSI method. A finite volume computational fluid dynamics code and a finite element structure dynamics code have been used concurrently to solve the flow and structure equations, respectively, to investigate the interaction between the blood flow and leaflet. As a result, it is observed that the leaflet is closing very slowly at the first stage of processing but it goes too fast at the last stage. And the results noted that the low pressure is formed behind leaflet to make the cavitation because of closing velocity three times faster than opening velocity. Also it is observed some fluttering phenomenon when the leaflet is completely opened. And the rebounce phenomenon due to the sudden pressure change of before and after the leaflet just before closing completely. The some of time-delay is presented between the inversion point of ventricle and aorta pressure and closing point of leaflet. The shear stress is bigger and the time of exposure is longer when the flow rate is maximum. So it is concluded that the distribution of shear stress at complete opening stage has big effect on the blood damage, and that the low-pressure region appeared behind leaflet at complete closing stage has also effect on the blood damage.

A Bicentric Propensity Matched Analysis of 158 Patients Comparing Porcine Versus Bovine Stented Bioprosthetic Valves in Pulmonary Position

  • Bunty Ramchandani;Raul Sanchez;Juvenal Rey;Luz Polo;Alvaro Gonzalez;Maria-Jesus Lamas;Tomasa Centella;Jesus Diez;Angel Aroca
    • Korean Circulation Journal
    • /
    • v.52 no.8
    • /
    • pp.623-631
    • /
    • 2022
  • Background and Objectives: Pulmonary valve replacement (PVR) is the most common operation in adults with congenital heart disease (CHD). There is controversy regarding the best bioprosthesis. We compare the performance of stented bioprosthetic valves (the Mosaic [MedtronicTM] porcine pericardial against Carpentier Perimount Magna Ease [EdwardsTM] bovine) in pulmonary position in patients with CHD. Methods: Between January 1999 and December 2019, all the PVRs were identified from hospital databases in 2 congenital heart centres in Spain. Valve performance was evaluated using clinical and echocardiographic criteria. Propensity score matching was used to balance the 2 treatment groups. Results: Three hundred nineteen patients were retrospectively identified. After statistical adjustment, 79 propensity-matched pairs were available for comparison Freedom from reintervention for the porcine cohort was 98.3%, 96.1%, and 91.9% at 3, 5, and 10 years and 100%, 98%, and 90.8% for the bovine cohort (p=0.88). Freedom from structural valve degeneration (SVD) for the porcine cohort was 96.9%, 92.8% and 88.7% at 3, 5, and 10 years and 100%, 98%, and 79.1% for the bovine cohort (p=0.38). Bovine prosthesis was associated with a reintervention hazard ratio (HR), 1.12; 95% confidence intervals (CIs), 0.24-5.26; p=0.89 and SVD HR, 1.69 (0.52-5.58); p=0.38. In the first 5 years, there was no difference in outcomes. After 5 years, the recipients of the bovine bioprosthesis were at higher risk for SVD (reintervention HR, 2.08 [0.27-16.0]; p=0.49; SVD HR, 6.99 [1.23-39.8]; p=0.03). Conclusions: Both bioprosthesis have similar outcomes up to 5 years, afterwards, porcine bioprosthesis seem to have less SVD.

Biocompatibility of Tissue-Engineered Heart Valve Leaflets Based on Acellular Xenografts (세포를 제거한 이종 심장 판막 이식편을 사용한 조직공학 심장 판막첨의 생체 적합성에 대한 연구)

  • 이원용;성상현;김원곤
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.297-306
    • /
    • 2004
  • Current artificial heart valves have several disadvantages, such as thromboembolism, limited durability, infection, and inability to grow. The solution to these problems would be to develop a tissue-engineered heart valves containing autologous cells. The aim of this study was to optimize the protocol to obtain a porcine acellular matrix and seed goat autologous endothelial cells on it, and to evaluate the biological responses of xenograft and xeno-autograft heart valves in goats. Material and Method: Fresh porcine pulmonic valves were treated with one method among 3 representative decellularization protocols (Triton-X, freeze-thawing, and NaCl-SDS). Goat venous endothelial cells were isolated and seeded onto the acellularized xenograft leaflets. Microscopic examinations were done to select the most effective method of decellularizing xenogeneic cells and seeding autologous endothelial cells. Two pulmonic valve leaflets of. 6 goats were replaced by acellularized porcine leaflets with or without seeding autologous endothelial cells while on cardiopulmonary bypass. Goats were sacrificed electively at 6 hours, 1 day, 1 week, 1 month, 3 months, and 6. months after operation. Morphologic examinations were done to see the biological responses of replaced valve leaflets. Result: The microscopic examinations showed that porcine cells were almost completely removed in the leaflets treated with NaCl-SDS. The seeded endothelial cells were more evenly preserved in NaCl-SDS treatment. All 6 goats survived the operation without complications. The xeno- autografts and xenografts showed the appearance, the remodeling process, and the cellular functions of myofibroblasts, 1 day, 1 month, and 3 months after operation, respectively. They were compatible with the native pulmonary leaflet (control group) except for the increased cellularity at 6 months. The xenografts revealed the new endothelial cell lining at that time. Conclusion: Treatment with NaCl-SDS was most effective in obtaining decellularized xenografts and facilitate seeding autologous endothelial cells. The xenografts and xeno-autografts were repopulated with myofibroblasts and endothelial cells in situ serially. Both of grafts served as a matrix for a tissue engineered heart valve and developed into autologous tissue for 6 months.