• Title/Summary/Keyword: Heart valves

Search Result 227, Processing Time 0.029 seconds

The relation of the bioprosthetic valve failure to its calcification (조직판막의 실패와 석회화에 관한 연구)

  • 홍유선
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.1001-1012
    • /
    • 1989
  • In 1968, Carpentier and his associates introduced glutaraldehyde as a compound for preparing cardiac tissue valve, and this technique has provided a considerably more suitable and durable tissue valve substitute. To increase further durability of valve tissue, Reis and his colleagues designed a flexible stent to reduce the stress on the heterogeneous tissue valve mounted. However with the advent of more innovative mechanical valve currently, many bioprosthetic valves are being substituted by mechanical valves at our department of cardiothoracic surgery because of bioprosthetic valve failure. Main cause of bioprosthetic valves failure were calcification or/and tear of tissue valves. The purpose of this retrospective study is to clarify the relationship between the patients clinical profile during implantation of tissue valves and pathologic features of the failed bioprosthetic valve. From March, 1982 through June, 1988, 53 bioprosthetic heart valves that had been ex-planted from 45 patients at the department of cardiac surgery of Yonsei University Hospital were subjected to this study. The patients were 10 to 65 year-old [mean age: 30.3 yr] with 17 males and 28 females. Re-replacements of prosthetic valves were carried out twenty nine in mitral position, eight in aortic position and eight in both aortic and mitral position simultaneously. The grading and location for calcification of valves were verified by radiograms. The calcification of the explanted valves leaflets was graded from 0 to 4 plus according to Cipriano and associates method. The types of tear and perforation of leaflet were classified into four types as Ishihara has adopted initially in 1981. In younger age group under thirty three years, explanted tissue valves were significantly more affected in terms of grades of severity of valve calcification as compared with older age group [p < 0.035]. Valve calcification appeared more severe in male as compared to female [p< 0.002]. Ionescu-Shiley bovine pericardial bioprosthetic valves showed more severe calcification than Hancock porcine tissue valves [p< 0.035]. Calcium deposit was found very prevalent at the area of commissural attachment [86 % of all]. Type I of valve rupture was shown to be related with simultaneous calcification. However, the relation of explanted valve position, duration of implanted prosthetic valve, atrial fibrillation and anticoagulant therapy to the severity of bioprosthetic valve calcification were not significantly clear statistically [p > 0.05].

  • PDF

A Study of the Acoustical Properties of the Mechanical Heart Valve Using MUSIC (MUSIC을 이용한 기계식 심장 판막의 음향 신호 특성 연구)

  • Yi S. W.;Choi M. J.;Min B. G.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.131-134
    • /
    • 1999
  • This paper considers the acoustical characteristics of the mechanical valve employed in the Korean type Artificial Heart. $Bj\"{o}rk-Shiley$ tilting disc valve was chosen for the study and acoustic measurements were performed for the artificial heart operated in a mock circulation system as well as implanted to an animal as a Bi Ventricular Assist Device (BVAD). In the mock system, three different conditions of the valve were examined which were normal, damaged (torn off), pseudothrombus attached. Microphone measurements for the BVAD were carried out at a regular time interval for 5 days after the implantation operation. Of the recorded acoustic emissions from the artificial heart, click sounds mainly originated from the valves were further analyzed using Multiple Signal Classification (MUSIC) for estimating their spectral properties. It was shown that the spectral peaks below 4 kHz and the optimal order number for MUSIC, equivalent to the number of the spectral component, might be the key parameters which were highly correlated to the physiological states of the valve like the mechanical damage of the valve or the formation of thrombus on the valves.

  • PDF

The Clinical Experience of 1000 Cases in Open Heart Surgery (개심술 1000예의 임상적 고찰)

  • 정정기
    • Journal of Chest Surgery
    • /
    • v.24 no.3
    • /
    • pp.271-279
    • /
    • 1991
  • From May 1977 to April 1990, 1000 cases of open heart surgery were performed under the cardiopulmonary bypass. There were divided into group A[500 cases, from May 1977 to June 23rd 1986] and group B[500 cases, from June 23rd 1986 to April 1990] which were analyzed, summarized, and compared. Of 1000 cases of open heart surgery, 677 cases[67.7%] were congenital heart diseases, and 323 cases[32.3%] were acquired heart diseases. In 677 cases of congenital heart disease, there were 545 cases with acyanotic congenital heart anomaly[A: 279, B: 266] and 132 cases with cyanotic congenital heart anomaly[A: 87, B: 45]. In 323 cases of acquired heart disease, most cases were valvular heart disease[315 cases, A: 133, B: 182] in which 357 valves were implanted. The operative mortality of congenital R acquired heart disease was 7.8% & 8.0%, and then overall mortality was 7.9%. The operative mortality was markedly decreased. [about half] from 10.0% of A group to 5.6% of B group.

  • PDF

Valve Replacement: Report of 100 Cases (심장 판막 이식 100례 보고)

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.11 no.2
    • /
    • pp.199-212
    • /
    • 1978
  • One hundred cases of cardiac valve replacement were done at this Department in the period from June 1968 to May 15, 1978. Seventy-one cases of mitral, 12 aortic, and one tricuspd valve were replaced. There were 16 cases of double valve replacement, 10 aortic with mitral and 6 mitral with tricuspid valve replacement. Prosthetic valves-Beall, Bjoerk-Shiley, Starr-Edwards, Wada-Cutter, Magovern-Cromie, and Smeloff-Cutter valves-were used. But in recent years bioprosthetic valves-Hancock, Carpentier-Edwards, and Angell-Shiley valves-were used mainly due to the difficulties of postoperative anticoagulation, especially for the rural Korean patients. Over all operative mortality was 2896, 26.2% for single and 37.5% for double valve replacement cases. There were 4 postoperative thrombo-embolism cases with 2 deaths. Four postoperative subacute bacterial endocardities cases with 2 deaths were noted. Three cases of postoperative congestive heart failure succumbed. Two cases of peri valvular leakage, one of which needs reopration, were found. There were 28 operative and 9 late deaths, leaving 63 long-tel m survivors, who showed marked improvements.

  • PDF

clinical results of the xenograft cardiac valves (이종심보직판막의 임상적 평가)

  • 박창권
    • Journal of Chest Surgery
    • /
    • v.22 no.1
    • /
    • pp.106-115
    • /
    • 1989
  • Clinical results with the xenograft cardiac valves were reviewed for 212 patients who underwent heart valve replacement from January 1981 to December 1987. One hundred and twenty-four Carpentier-Edwards k 88 Ionescu Shiley valves were used. Overall operative mortality was 11 out of 212[5.1%]: 5 out of 153[3.39o] for mitral valve replacement [MVR], 2 out of 34[5.9%] for aortic valve replacement [AVR], 0 out of 4[0%] for Tricuspid valve replacement [TVR], and 4 out of 21[19.1%] for double valve replacement [DVR;MVR+ AVR]. Two hundred and one operative survivors were followed up for a total of 824.3 patient-years [a mean 3.9*1.8 yrs], and the follow up was 78.1%. The linealized complication rates were 0.1% emboli / patient-year, 1.0% endocarditis/ patient-year and 2.2% overall valve failure / patient-year. A linealized rate of primary tissue failure was 0.7*/o/ patient-year. The actuarial survival rates including the operative mortality were 92*2.8% at 4 years and 85*4.3% at 7 years after surgery using the Xenograft cardiac valves. Probabilities of freedom from thromboembolism and overall valve failure were 73*11.0% and 69*2.4% at 7 years after surgery using the Xenograft cardiac valves respectively. The intrinsic durability of the Xenograft cardiac valves appears to be relatively well satisfactory over the long term [4 to 7 years] and the risk of failure appears well balanced by the advantages of a low incidence of thromboembolism and no mandatory anticoagulant therapy.

  • PDF

Noninvasive assessment of pressure gradients across prosthetic heart valve by doppler ultrasound -A comparative studyof the duromedics bileaflet valves in mitral position and normal mitral valves- (도플러 초음파를 이용한 인공판막 상하의 압력차 측정에 관한 연구 -승모판막 치환에 사용한 Duromedics 인공판막과 정사인의 승모판막과의 비교연구-)

  • Jin, Seong-Hun;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.223-229
    • /
    • 1987
  • Doppler echocardiography provides valuable information regarding prosthetic heart valve function rather than structure. There are three methods of expressing the severity of mitral valve obstruction: the transvalvular pressure gradient, effective valve area, and pressure half-time. Of these, the transvalvular pressure gradient [~p] can be determined by the measurement of maximum transvalvular blood flow velocity [V] according to the modified Bernoulli`s equation [gp=4V*]. Eleven patients, who underwent mitral valve replacement with Duromedics mechanical prostheses, and 17 normal persons were investigated. There were significantly higher calculated pressure gradients in prosthetic than normal mitral valves [9.*10*2.22mmHg-vs-3.26*0.99mmHg:p<0,01], and there was a inverse relationship between pressure gradient and prosthetic valve size [11.17*0.%mmHg in size 27mm and 29mm -v- 7.38*1.12mmHg in size 31mm and 33mm; r=0.85, p<0.01] The noninvasive Doppler technique should be useful in the diagnosis of prosthetic valve obstruction.

  • PDF

개심술에 관한 연구1979년도 320례 분석

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.13 no.1
    • /
    • pp.1-12
    • /
    • 1980
  • In 1979 during the period of about 10 months 320 cases of open heart surgery were done in Seoul National University Hospital. There were 220 Congenital anomaly cases consisting of 113 acyanotic and 107 cyanotic varieties, and 1 O0 acquired cardiac lesions. Out of 100 acquired lesions 96 were valvular cues. Among 97 valve replacement cases 3 were Ebstein anomaly treated with plication and tricuspid valve replacement. Operative mortality rate for congenital anomaly was 10.6%, with 2.7% for acyanotic and 22.4% for cyanotic group. For acquired lesions over all operative mortality was 7%. Tetralogy of Fallot, ventricular septal defect, and atrial septal defect were the 3 main congenital anomalies, with 88 cues, 69 cases, and 27 cues respectively. In 61 simple ventricular septal defect without other anomalies operative mortality rate was 1.6%, in 27 atrial septal defect no death and, in tetralogy of Fallot 12.2%. Among 69 ventricular septal defect cases 19[27.5%] type I VSDs, after Kirklin-Becu classification, were found, rather high relative incidence of type I compared with Caucasian patients. Among 97 valve replacement cases 20 double valves were replaced-11 mitral with aortic and 9 mitral with tricuspid valves. Over all operative mortality rate for valve replacement was 8.2% with 3.3% in 61 mitral valve replace-merit. The over all operative mortality rate for 320 open heart surgery cases was 10.6%. Bubble type oxygenator and xenograft bioprosthetic valves were utilized In almost all cases.

  • PDF

Re-replacement of prosthetic heart valves: report of 7 cases (인공심장판막의 재치환수술: 7례 보)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • v.17 no.1
    • /
    • pp.3-11
    • /
    • 1984
  • Prosthetic valve replacement has resulted in marked improvement in the functional status of many patients with valvular heart disease. But valve failure from various causes has necessitated re-replacement of prosthetic valve in some of these patients. This selective group of patients has many inherent problems. This report presents our experience with seven patients who received re-replacement of prosthetic valve in the Seoul National University Hospital from 1981, to 1983. The patients included one woman and six men in the range of 9 and 49 years old. As the first valve operations, there were five MVR using tissue valves, one DVR [Bjork-Shiley and Ionescu-Shiley valve] and one case of modified Bentall operation with composite graft [Ionescu-Shiley valve]. Reoperations on prosthetic valve failure were performed 17 to 54 months after the first operation [mean 34 months]. Amon8 seven patients, there were two cases of prosthetic valve endocarditis and five cases of primary tissue failure. Gross calcification of the xenograft was found in two children with Ionescu-Shiley valve. All except one had relatively successful operative results. The unsuccessful one died intraoperatively from low output syndrome.

  • PDF

Effects of chemical restraint drugs on Doppler echocardiography in normal dogs (화학적 보정약이 정상견의 도플러 심초음파에 미치는 영향)

  • Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.2
    • /
    • pp.413-418
    • /
    • 1998
  • Intracardiac velocities were determined and the wave-forms described for 4 flow areas of the normal canine heart following administration of chemical restraint drugs including xylazine HCl, ketamine HCl, and thiopental sodium using pulsed wave Doppler echocardiography. The result was that xylazine HCl and thiopental sodium reduced intracardiac flow velocities through mitral, tricuspid, aortic and pulmonary valves. It is also thought that precautions are required before using these drugs. Patterns of wave-forms had no changes between control and treatment groups. Doppler echocardiography allows the clinician to determine flow velocities across the different valves and within the various chambers of the heart. It is shown that establishing normal values and those related to chemical restraint administrations and knowing what influences them should allow the clinician to non-invasively diagnose a variety of pathological cardiac conditions.

  • PDF

In Vitro Analysis of Supplementary Valve (보조판막의 생채외 실험 연구)

  • Kim, S.H.;Park, Y.H.;Yoon, C.S.;Kim, H.M.;Cho, B.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.329-332
    • /
    • 1997
  • To develop the supplementary heart valve which could reduce the complications of prosthetic heart valve, in vitro experiments were performed to analyze the movement of the supplementary valves. The autologous pericardium was attached to deficient portion of the porcine valve which was dissected completely and partially. The instantaneous motion of the leaflet was pictured by the 35mm camera and the pressure drop through the valve and cardiac output were measured in mock circulatory system. The durability of the valves were tested in severe hemodynamic conditions.

  • PDF