• Title/Summary/Keyword: Heart tube

Search Result 124, Processing Time 0.025 seconds

Development of pulse diagnosis possible simulator using the stepper motor pumps (스텝 모터 펌프를 이용한 맥진 가능한 시뮬레이터의 개발)

  • Ryu, Geun-Taek;Woo, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.915-918
    • /
    • 2016
  • Virtual testing devices are required due to rapid changes in the health care industry and the increase of the medical or nursing workforce. The importance of devices such as the simulator, blood vessels, and lab equipment for modeling blood flow to the heart is increasing too. In this study, we made heart pump by using a step motor and developed device which simulates arterial, venous blood pressure, and blood flow. We finally evaluated the function of proposed device. The proposed system is composed of the pump for simulating, the valve device to describe the resistance of the artery and vein, and a reducing device showing the characteristics of the venous system. We used BOXER pump for heart simulator and silicon tube for arterial and venous vessels, and designed a reducing device. We also used the pressure sensor to measure arterial blood pressure. For the evaluation of the proposed system, we selected a range of 50~100mmHg of the blood circuit 60 per minute and then compared the blood pressure of a person and the measured blood pressure.

  • PDF

A Study on the Measurement of the Normal Tracheal Length in Korea adults (한국성인의 기관 길이 측정에 관한 연구)

  • 나명훈
    • Journal of Chest Surgery
    • /
    • v.28 no.8
    • /
    • pp.766-771
    • /
    • 1995
  • The trachea is defined as the airway from the inferior border of the cricoid cartilage to the top of the carinal spur. This paper would confirm the normal tracheal length of Korean adults through the actual measurement using the fiberoptic bronchoscopy. The subjects of this study were 25 patients, 13 males and 12 females between the age of 20 to 69 without abnormality on the neck, trachea, mediastinum and lung pharenchyme on the preoperative chest X-ray, who received the operations from the period of July to September, 1994. For those patients who had heart diseases, the cardiothoracic ratio was below 50%. The measurement was performed on the patients with endotracheal intubation under the general anesthesia in supine and neutral position. The tracheal length was calculated by the difference between the length from the tip of the endotracheal tube [E-tube to carina and to the needle which was inserted into the E-tube at the lower border of the palpated cricoid cartilage, by inserting the broncoscopy through the E-tube. The result was as follow : 1 The measured tracheal length for men was 11.8 0.2 cm[mean standard deviation and women was 10.5 0.3 cm, and that was longer than this [p<0.01 . The average was 11.2 1.0 cm and the standard error was 0.20 cm. 2 According to the correlation between the tracheal length to weight, height[Ht , age, and body surface area[BSA respectively, the Ht [p=0.003 , age [p=0.055 , and the BSA[p=0.017 were significant, while weight was not [p=0.314 . 3 From the regression analysis of the tracheal length[T.L. to the Ht, Age, and the BSA which were significant, the following equation was derived.i Ht : T.L.= -1.29 + 0.076 x Ht [P=0.003 ii Age: T.L.= 10.04 + 0.028 x Age [P=0.055 iii BSA : T.L.= 5.60 + 3.48 x BSA [P=0.017 iv In multi-regression : T.L. = -4.15 + 0.034 x Age + 0.085 x Ht [P=0.0002]

  • PDF

Effects of Non-nutritive Sucking on the Physiological and Behavioral States of Pre-term Infants during Tube Feeding (달래기 젖꼭지의 제공이 위관수유 중인 미숙아의 생리적 상태 및 행동적 상태에 미치는 영향)

  • Joung Kyoung-Hwa;Yoo Il-Young;Kim Hee-Soon;Kim Soo;Lee Ja-Hyung
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.5
    • /
    • pp.732-741
    • /
    • 2006
  • Purpose: This study was to investigate the effects of non-nutritive sucking on physiological and behavioral state of pre-term infants during tube feeding. Method: This nonequivalent, non-synchronized experimental study included 50 pre-term infants. An attempt was made to match gestational age and birth weight of infants in each group. Infants in the experimental group were given a pacifier 2 minutes before, during, and for 2 minutes after tube feeding. Infants in the control group did not get a pacifier. Both groups were tested at three stages for changes in the physiologic state and behavioral state - 2 minutes before, during, and 2 minutes after feeding. Date was analyzed with SPSS WIN 10.0 using an $X^2$-test, t-test, and repeated measures ANOVA. Result: Heart rates and oxygen saturation levels of the two groups were significantly different(P=.001, P=.000). The behavioral states of the two groups were significantly different during and post feeding(P=.000, P=.000). Conclusion: This result suggests non-nutritive sucking by using a pacifier is an effective intervention for pre-term infants during tube feeding.

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

Ventilator-Associated Pneumonia in Neonatal Intensive Care Unit : Clinical Manifestations, Ddiagnostic Availability of Endotracheal Tip Culture (신생아 집중치료실에서 인공 환기요법 관련 폐렴의 임상양상과 기관내 삽관의 유용성에 관한 연구)

  • Kim, Nam Young;Sung, Tae Jung;Shin, Seon Hee;Kim, Sung Koo;Lee, Kon Hee;Yoon, Hae Sun
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.1
    • /
    • pp.67-74
    • /
    • 2005
  • Purpose : The incidence of mortality associated with respiratory difficulties is decreasing nowadays contributed to the development of neonatology. However, complications associated with mechanical ventilator are increasing. This study is to determine clinical manifestations, diagnositc availability of the endotracheal tip culture in patients with Ventilator-Associated Pneumonia(VAP) in neonatal intensive care unit(NICU). Methods : A retrospective analysis of 50 neonates who were admitted to the NICU of Kangnam Sacred Heart Hospital and had given mechanical ventilator from 1 January 2000 to 30 June 2003. VAP group defined as neonates who had pneumonia with mechanical ventilation longer than 48 hours. They were classified into VAP group(n=13) and control group (n=37) and the prevalence, microorganisms cultured from the endotracheal tube tip and risk factors were investigated. Results : The prevalence of VAP was 26.0%(n=13) and the most dominant microorganism cultured in our NICU was methicillin-resistant coagulase negative staphylococcus(MR-CNS) in 4 cases. Other microorganisms were Pseudomonas, Enterobacter, methicillin-resistant Staphylococcus aureus(MRSA) and Klebsiella. Gestational age, birth weight, Apgar score, respiratory distress syndrome, retinopathy of prematurity, bronchopulmonary dysplasia, sepsis, renal failure, pulmonary hemorrhage, pneumothorax were not different significantly between two groups except intraventricular hemorrhage(P<0.001) and patent ductus arteriosus(P<0.05). Duration of hospital stay and mortality rate were also not different significantly. Conclusion : VAP occurred at a significant rate among mechanically ventilated NICU patients. Despite of limitation of encotracheal tip culture, the most common microorganism was MR-CNS. We should be aware of occurrence of VAP in NICU neonate who were with mechanical ventilator and should treat with great care.

  • PDF

Truncus Arteriosus -Report of a Case- (동맥간(動脈幹) 1례(例) 보고(報告))

  • Hong, Jang Soo;Park, Joo Chul;Rho, Joon Ryang;Kim, Chong Whan;Suh, Kyung Phil;Lee, Yung-Kyoon
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.271-275
    • /
    • 1976
  • Truncus arteriosus is a rare and highly lethal cardiac anomaly characterized by a single arterial trunk emerging from the heart and supplying the coronary, systemic, and pulmonary circulations, The first successful correction of truncus arteriosus was reported by McGoon et al. in 1968 and was based on experimental work reported by Rastelli et al. in 1967 in which a conduit consisting of a homograft of the ascending aorta and aortic valve was used to establish continuity between the right ventricle and the pulmonary arteries, Modification of this procedure using a Dacron tube valved with porcine xenograft instead of a homograft have resulted in the current definite treatment for truncus arteriosus. This report describes an 3 years and 4 months old boy with heart failure from type I truncus arteriosus who was diagnosed as the V. S. D. with pulmonary hypertension preoperatively and underwent corrective surgery employing the Rastelli procedure using a Dacron conduit valved with canine xenograft, but died due to massive bleeding from the anastomosis sites in operating room.

  • PDF

Studies on the Distribution and Accumulation of Mercury in Rat Organs after Administration of Red Mercuric Sulfide (Red Mecuric Sulfide투여 후의 백서체내 수은분포에 관한 연구)

  • 손동헌;최영호
    • YAKHAK HOEJI
    • /
    • v.26 no.4
    • /
    • pp.253-256
    • /
    • 1982
  • The organ distribution of mercury was examined in the rat after oral administration of a single dose of red mercuric sulfide (15mg Hg/kg). The concentration of total mercury in the organs and blood after 2, 4, 6, 8, 12, 24 and 72 hours of administration was determined by Quartz Tube Combustion-Gold Amalgamation Method. It was found that the maximal concentration of total mercury was in the kidneys and muscle within 24 hours and in the brain, heart, liver and blood within 48 hours. The descending order of the maximal organ and blood concentration was: kidneys(1.08ppm)>blood> muscle>heart>liver>brain. The accumulation states of total mercury in the rat organs were investigated by continuous administration of red mercuric sulfide (5mg Hg/kg/day) for 15 days. The mercury concentration increased progressively throughout the experimental period and the descending order of the highest level of mercury after 15 days was: kidneys (1.55ppm)>blood>liver. The concentration of alkyl mercury in brain, liver and kidneys also was measured after 7 and 15 days of consecutive administration of red mercuric sulfide (5mg Hg/kg/day). The concentration in the Kidneys and the liver was very low, but was significantly different from control group. The concentration in the brain was extremely low and was not significantly different from control group.

  • PDF

Critical Care Nurses' Perception, Knowledge, and Practices of Enteral Nutrition (중환자간호사의 경관영양 공급에 대한 인식과 지식 및 수행)

  • Kim, Hyunjung;Soun, Eunjin
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.23 no.4
    • /
    • pp.383-392
    • /
    • 2016
  • Purpose: The purpose of this study was to assess critical care nurses' perception, knowledge, and nursing practices regarding enteral nutrition. Methods: A descriptive study was conducted with 187 nurse participants who worked in one of the eight medical and surgical intensive care units (ICUs) from four hospitals in Korea. Data were collected using a self-administered questionnaire. Results: Although critical care nurses' perception toward enteral nutrition was high, knowledge was relatively low. The overall perception and knowledge of the nurses did not differ significantly between medical ICU and surgical ICU nurses. Perception of their own knowledge, in particular, 'nutritional goal' was lower for medical ICU nurses compared to surgical ICU nurses. Nurses also had limited knowledge about the significance of enteral nutrition, confirmation of feeding tube location, and nutritional requirements for ICU patients. They inadequately performed the following: changing the feeding tube every 24 hours, inspecting nostrils daily, and adjusting feeding schedule if feeding was stopped. Conclusion: Our results indicate that ICU nurses need up-to-date information about enteral nutrition. Based on the improved perception and knowledge, nursing practice activities with regard to enteral nutrition should be emphasized to enable nurses to provide optimal nutrition for ICU patients.

Fluoroscopic Radiation Exposure during Percutaneous Kyphoplasty

  • Choi, Hyun-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.1
    • /
    • pp.37-42
    • /
    • 2011
  • Objective: The author measured levels of fluoroscopic radiation exposure to the surgeon's body based on the different beam directions during kyphoplasty. Methods: This is an observational study. A series of 84 patients (96 vertebral bodies) were treated with kyphoplasty over one year. The patients were divided into four groups based on the horizontal and vertical directions of the X-Ray beams. We measured radiation exposure with the seven dosimetry badges which were worn by the surgeon in each group (total of 28 badges). Twenty-four procedures were measured in each group. Cumulative dose and dose rates were compared between groups. Results: Fluoroscopic radiation is received by the operator in real-time for approximately 50% (half) of the operation time. Thyroid protectors and lead aprons can block radiation almost completely. The largest dose was received in the chest irrespective of beam directions. The lowest level of radiation were received when X-ray tube was away from the surgeon and beneath the bed (dose rate of head, neck, chest, abdomen and knee: 0.2986, 0.2828, 0.9711, 0.8977, 0.8168 mSv, respectively). The radiation differences between each group were approximately 2.7-10 folds. Conclusion: When fluoroscopic guided-KP is performed, the X-Ray tube should be positioned on the opposite side of the operator and below the table, otherwise the received radiation to the surgeon's body would be 2.7-10 times higher than such condition.

Study on the Effect of Performance Factors on the Finned Tube Type Regenerator for Liquid Desiccant Dehumidification (액체 건조제 제습을 위한 핀튜브형 재생기의 성능인자 영향 연구)

  • Jang, Jun-Oh;Park, Moon-Soo;Kang, Kyung-Tae;Lee, Shin-Pyo;Lee, Jin-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.845-852
    • /
    • 2003
  • Liquid desiccant dehumidification system can be used effectively to save energy consumed in air conditioning as an alternative compared with conventional air conditioning systems by reducing latent heat load. The dehumidifier and the regenerator from the heart of this system. The latent part of the cooling load is handled using liquid desiccant. In this study, the experimental regenerator has been designed to study the regeneration characteristics of the aqueous triethylene glycol(TEG) system. The performance factors of the regenerator with finned tube heat exchanger were evaluated by a series of experimental runs. The regeneration process is highly dependent on the liquid desiccant conditions, such as, temperature, concentration and flow rate. In addition, the effects of the inlet air temperature, humidity and flow rate were discussed. Data obtained are useful for design guidance and performance analysis of a regenerator, particularly for a liquid desiccant cooling system.