• Title/Summary/Keyword: Heart development

Search Result 1,082, Processing Time 0.034 seconds

Development of the ubiquitous health care module for a bidet (비데용 유비쿼터스 헬스케어 모듈 개발)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.931-936
    • /
    • 2012
  • In this paper, the module which can measure body fat, heart rate and $SpO_2$ has been developed for being mounted on widespread bidets in the home. This moudule was manufactured by a structure that can be mounted on a bidet, users such as elderly, patients with chronic fatigue, heart disease and overworked workers checking their health status in every life through monitoring their body fat, heart rate and $SpO_2$ and preventing of sudden death.

Review of Simulators for Cardiovascular System (심혈관계 시뮬레이터의 연구동향)

  • Shin, Sang-Hoon;Lee, Ju-Yeon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.1
    • /
    • pp.55-66
    • /
    • 2011
  • Objectives: The purpose of this study is to review the simulator for cardiovascular system. Methods & Results: Simulators were classified according to the structure and function of cardiovascular system. Heart and blood vessel were selected as the represent of structure. Blood pressure and blood flow were chose as the functional index. With the view points of four keywords, four kinds of simulators were selected: artificial heart, pressure simulator, flow simulator, and pulse simulator. Conclusions: This paper discussed the state of the art of research and development of the selected four kinds of simulators.

Development of Evacuee Support Using Heart Rate Variability

  • Hayashida, Yukuo;Kidou, Keiko;Mishima, Nobuo;Kitagawa, Keiko;Oh, Yong-sun;Yoo, Jaesoo
    • International Journal of Contents
    • /
    • v.13 no.2
    • /
    • pp.1-5
    • /
    • 2017
  • Residents under hazard and disaster conditions should be evacuating to the pre-assigned nearest safety facilities, community hall, local schools, friend's houses, etc. in a safety zone, quickly as soon as possible. The small percentage of evacuees shows serious economy class syndrome after the quake, because those people are forced to a stressful dairy evacuee-life in scattered homes and/or in-vehicle, for instance. Then, we consider on supporting evacuees using heart rate variability, Geospatial Positioning System (GPS) and WiFi functions of a smartphone, and Web-server on the Internet to keep their health in good conditions.

Development of the Rolling-cylinder Type Motor-driven Total Artificial Heart System

  • Min, Byoung-G.;Kim, Hee-C.;Cheon, Gill-J.
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.161-170
    • /
    • 1987
  • A new type of motor-driven total artificial heart system with a rolloing-cylinder mechanism has been developed. The prototype system consists of a brushless DC motor inside of a rolling-cylinder, two arc shaped pusher-plate s, and two ventricles of smooth, seamless polyurethane sacs. The motor-driven pump has the advantages of being portable and quiet compared to the present air-driven pump. It can also be controlled more accurately. This rolling-cylinder type electromechanical pump has several structural advantages including small size and weight, as compared to other research groups' motor-driven pumps. The results of mock circulation tests confirm sufficient pump output capacity(cardiac output . 9 L/min, at aortic pressure'120mmHg, with heart rate . 120 BPM) for animal implantation of our prototype system.

  • PDF

A Numerical Analysis on the Motion of a Curved Bileaflet in Mechanical Heart Valve(MHV) and the Characteristics of Blood Flow in an Elastic Blood Vessel (탄성혈관 내 곡면형 이엽 기계식 인공심장판막의 거동 및 혈액 유동 특성에 관한 수치해석적 연구)

  • Bang J. S.;Choi C. R.;Kim C. N.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.203-206
    • /
    • 2004
  • In this study, a numerical analysis has been performed for a three-dimensional pulsatile blood flow associated with the elastic blood vessel and curved bileaflet for multiple cycles in terms of fluid-structure interaction. Here, blood has been assumed as a Newtonian, incompressible fluid. Pressure profiles have been used as boundary conditions at the ventricle and the aorta. From this analysis, the motion of the leaflet has been observed with fluttering phenomenon and rebound, and the flow fields of blood have been obtained with recirculation and regurgitation. The results can contribute to the development of design methodology for the curved bileaflet mechanical heart valve.

  • PDF

Development of a Microcontroller-based Brushless DC Motor Control System for an Total aAtificial Heart

  • Choi, Won-Woo;Park, Seong-Keun;Choi, Jae-Soon;Min, Byoung-Goo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.509-513
    • /
    • 1995
  • A microcontroller-based DC motor control system for a total artificial heart(TAH) was developed. Using a one-chip microcontroller, 87Cl96KB, the design of digital motor speed control system and servo control system is demonstrated. Functionally, the control system consists of a position control unit, a speed control unit, and a communication unit. The performance and the reliability of the developed control system were assessed through a series of mock circulation system experiments.

  • PDF

Development of an Automatic Cardiac Output Control Algorithm for the Total Artificial Heart (완전 이식형 인공심장의 심박출량 자동 제어 알고리즘 개발에 관한 연구)

  • 최원우;김희찬;민병구
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.3
    • /
    • pp.38-47
    • /
    • 1995
  • A new automatic cardiac output control algorithm for the motor-driven electromechanical total artificial heart(TAH) was developed based on the motor current waveform analysis without using any extra transducer. The basic control requirements of artificial heart can be described in terms of three features : preload sensitivity, afterload insensitivity, and balanced ventricular outputs. In the previous studies, many transducers were utilized to obtain informations of hemodynamic states for the automatic cardiac output control, But such automatic control systems with sensors have had reliability problems. We proposed a new sensorless automatic cardiac output control algorithm providing adequate cardiac output to the time-varying physiological demand without causing right atrial collapse, which is one of the critical problem in an active-filling type device. In-vitro tests were performed on a mock circulation system to evaluate the performance of the developed algorithm and the results show that the new algorithm satisfied the basic control requirements on the cardiac output response and the possibility of application of the developed algorithm to in vivo experiments.

  • PDF

Development of an integrative cardiovascular system model including cell-system and arterial network (세포-시스템 차원의 혈류역학적 심혈관 시스템 모델의 개발)

  • Shim, Eun-Bo;Jun, Hyung-Min
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.542-546
    • /
    • 2008
  • In this study, we developed a whole cardiovascular system model combined with a Laplace heart based on the numerical cardiac cell model and a detailed arterial network structure. The present model incorporates the Laplace heart model and pulmonary model using the lumped parameter model with the distributed arterial system model. The Laplace heart plays a role of the pump consisted of the atrium and ventricle. We applied a cellular contraction model modulated by calcium concentration and action potential in the single cell. The numerical arterial model is based upon a numerical solution of the one-dimensional momentum equations and continuity equation of flow and vessel wall motion in a geometrically accurate branching network of the arterial system including energy losses at bifurcations. For validation of the present method, the computed pressure waves are compared with the existing experimental observations. Using the cell-system-arterial network combined model, the pathophysiological events from cells to arterial network are delineated.

  • PDF

Real-time Heart Rate Measurement based on Photoplethysmography using Android Smartphone Camera

  • Hoan, Nguyen Viet;Park, Jin-Hyeok;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.2
    • /
    • pp.234-243
    • /
    • 2017
  • With the development of smartphone technologies enable photoplethysmogram (PPG) acquisition by camera and heart rate (HR) measurement. This papers presents improved algorithm to extract HR from PPG signal recorded by smartphone camera and to develop real-time PPG signal processing Android application. 400 video samples recorded by Samsung smartphone camera are imported as input data for further processing and evaluating algorithm on MATLAB. An optimized algorithm is developed and tested on Android platform with different kind of Samsung smartphones. To assess algorithm's performance, medical device Beurer BC08 is used as reference. According to related works, accuracy parameters includes 90% number of samples that has relative errors less than 5%, Person correlation (r) more than 0.9, and standard estimated error (SEE) less than 5 beats-per-minutes (bpm).

A review of rare complications of maxillary sinus floor augmentation

  • On, Sung Woon;Cho, Seoung-Won;Yang, Byoung-Eun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.6
    • /
    • pp.351-356
    • /
    • 2019
  • Maxillary sinus floor augmentation (MSFA) is an essential procedure for implant installation in the posterior maxillary area with vertical alveolar bone deficiency. For the past several decades, MSFA has been refined in terms of surgical methods along with technical progress, accumulation of clinical studies, and development of graft materials and surgical instruments. Although some complications in MSFA are inevitable in clinical situations, management of those complications in MSFA has been well established thanks to many clinicians and researchers. Nevertheless, some rare complications may arise and can result in fatal results. Therefore, clinicians should be well aware of such rare situations and complications associated with MSFA. In this review, the authors present several rare complications regarding MSFA, along with corresponding management strategies through a thorough review of the literature.