• 제목/요약/키워드: Heart Valve Prosthesis

검색결과 114건 처리시간 0.037초

고속 사진기와 영상처리 기법을 이용한 인공판막의 흐름 분석. (Flow Pattern Analysis of Artificial Valves Using High Speed Camera and Image Processing Technique)

  • 이동혁;김희찬;서수원;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.81-84
    • /
    • 1993
  • Artificial Heart Valve is the one of the most important artificial organ which has been implanted to many patients. The most important problems related to the artificial heart valve prosthesis are thrombosis and hemolysis. Usual method to test against this problem in vivo experiment, which is complex and hard work. Nowadays the request for In vitro Artificial Heart Valve testing system is increasing. Several papers has announced us flow pattern of Artificial Heart Valve is highly correlated with thrombosis and hemolysis. They usually gel flow pattern by LDA, it is also hard work and has narrow measuring region. In this reason we have determined to develop PTV(Particle Tracking Velocimetry). By using High-speed camera and image processing technique, flow pattern could be relatively easily obtained. Parachute and Bileaflet Artificial Heart Valve designed by SNU were testified.

  • PDF

인공 심장판막의 재치환술 -수술 위험인자와 수술 결과의 분석- (Reoperation of Prosthetic Heart Valve; An Analysis of Operative Risks and Late Results)

  • 김관민
    • Journal of Chest Surgery
    • /
    • 제28권1호
    • /
    • pp.23-30
    • /
    • 1995
  • From January 1985 to December 1992, of 1257 patients who underwent a heart valve replacement 210 [16.8% underwent reoperation on prosthetic heart valves, and 6 of them had a second valve reoperation. The indications for reoperation were structural deterioration [176 cases, 81.5% , prosthetic valve endocarditis [25 cases, 11.6% , paravalvular leak [12 cases, 5.6% , valve thrombosis [2 cases, 0.9% and ascending aortic aneurysm [1 case, 0.4% . Prosthetic valve failure developed most frequently in mitral position [57.9% and prosthetic valve endocarditis and paravalvular leak developed significantly in the aortic valve [40%, 75% [P<0.02 . Mean intervals between the primary valve operation and reoperation were 105.3$\pm$28.4 months in the case of prosthetic valve failure, 61.5$\pm$38.5 months in prosthetic valve endocarditis, 26.8$\pm$31.2 months in paravalvualr leak, and 25.0$\pm$7.0 months in valve thrombosis. In bioprostheses, the intervals were in 102.0$\pm$23.9 months in the aortic valve, and 103.6$\pm$30.8 months in the mitral valve. The overall hospital mortality rate was 7.9% [17/26 : 15% in aortic valve reoperation [6/40 , 6.5% in reoperation on the mitral prostheses [9/135 and 5.7% in multiple valve replacement [2.35 . Low cardiac output syndrome was the most common cause of death [70.6% . Advanced New York Heart Association class [P=0.00298 , explant period [P=0.0031 , aortic cross-clamp time [P=0.0070 , prosthetic valve endocarditis [P=0.0101 , paravalvularr leak [P=0.0096 , and second reoperation [P=0.00036 were the independent risk factors, but age, sex, valve position and multiple valve replacement did not have any influence on operative mortality. Mean follow up period was 38.6$\pm$24.5 months and total patient follow up period was 633.3 patient year. Actuarial survival at 8 year was 97.3$\pm$3.0% and 5 year event-free survival was 80.0$\pm$13.7%. The surgical risk of reoperation on heart valve prostheses in the advanced NYHA class patients is higher, so reoperation before severe hemodynamic impairment occurs is recommended.

  • PDF

심장 판막 수술 후 미세색전의 변화 (Changes of Microembolic Signals after Heart Valve Surgery)

  • 조수진;이은일;백만종;오삼세;나찬영
    • Journal of Chest Surgery
    • /
    • 제36권5호
    • /
    • pp.316-320
    • /
    • 2003
  • 배경: 경두개 초음파 검사에 의한 미세색전의 진단은 향후 뇌색전증의 위험이 높은 환자의 선별에 큰 도움이 되리라 기대된다. 우리는 전향적으로 심장 판막 수술 전과 후의 미세색전의 양성률과 빈도를 검사하였다. 대상 및 방법: 심장 판막 질환이 있는 50명의 환자를 대상으로 본 연구는 진행되었다. 뇌경색의 병력이 있거나, 과거에 인공 기계 심장 판막 수술을 받은 환자는 본 연구에서 제외하였다. 경두개 초음파 검사는 중대뇌동맥에서 1시간 동안 미세색전을 감시하였고, 수술 전과 수술 후 2차례 검사하였다. 결과: 기계 심장 판막 수술은 28명, 조직 판막 수술은 10명, 승모판막 성형술은 12명에서 시행되었다. 미세색전의 양성률은 수술 전(8%)에 비하여 수술 후(50%)에 의미 있게 증가하였으며 (p=0.00), 미세색전은 항응고제 강도, 심장 부정맥, 환자의 연령, 고혈압의 병력과 관련성이 없었다. 기계 심장 판막 이식수술 후 미세색전의 양성률(71.4%)은 조직 판막 이식수술(10%)이나 승모판막 성형술(33.3%)에 비하여 의미 있게 높았다(p=0.002). 결론: 미세색전은 심장 판막 수술 후 의미 있게 증가하며 이러한 변화는 인공 기계 심장 판막 수술 후 색전증의 위험과 관련되어 있다고 추정된다.

ATS 기계판막의 단기 임상성적 (Clinical Evaluation of the ATS Valve Replacement)

  • 김학제;조성준
    • Journal of Chest Surgery
    • /
    • 제30권3호
    • /
    • pp.293-299
    • /
    • 1997
  • 고려대학교 구로병원에서는 1994년 8월부터 국내에서는 처음으로 새로운 이엽성 기계판막인 ATS(Advancing The Standard)을 이용, 21명의 환자에게 28개의 판막을 치환하였다. 환자는 평균연령 27세로 10명의 남자와 11명의 여자로 수술전후의 NYHA 기능적분류는 평균 2.9에서 1.4로 감소하였다. 심초음파상의 심박출 지수는 55.5에서 59.8으로 다소 상승하였다. 치환후 승모판 전후의 압력차는 양호하였으며,용혈 여부를 확인하기위한 LDH치는 다소 상승하였으나 임상적 중요성은 없었다. 판막과 관련된 합병증은 없었으며, 항응고제 투여와 관련된 뇌출혈이 1례 있었다. 사망례는 없었으며, 현재는 모든 환자에

  • PDF

임신중 발생한 인공승모판 혈전증의 혈전 용해제를 이용한 치료 -치험 1례 보고- (Thrombolytic Therapy for Prosthetic Mitral Valve Thrombosis of Pregnant Patient -A Case Report-)

  • 김영대
    • Journal of Chest Surgery
    • /
    • 제27권10호
    • /
    • pp.858-861
    • /
    • 1994
  • Prosthetic valve thrombosis is rare but it is one of fatal complication after heart valve surgery. Improvements of the valve design and the material have decreased the frequency of thrombosis but have not eliminated completely. And some cases of prosthetic valve thrombosis during pregnancy were reported inspite of adequate anticoagulation therapy.Urgent surgical intervention is indicated for prosthetic valve thrombosis but it is associated with high operative risk, therefore medical thrombolytic therapy such as urokinase or streptokinase therapy is regarded as an alternative therapy. This is a case report of the successful thrombolytic therapy for valve thrombosis in a pregnant patient after mechanical mitral valve replacement.

  • PDF

삼첨판막 치환술의 장기성적 (Long-Term Result of Tricuspid Valve Replacement)

  • 임청;강문철;김경환;김기봉;안혁
    • Journal of Chest Surgery
    • /
    • 제34권9호
    • /
    • pp.680-685
    • /
    • 2001
  • 배경: 삼첨판막친환술은 매우 드물게 시행되는 수술이며 그 장기 성적은 만족치 못한 수준이다. 또한 어떤 종류의 인공판막을 사용하느냐에 대하여도 논란이 많은 상황이다. 서울대학교병원 흉부외과에서는 1989년 1월부터 1998년 12월까지 10년동안 71명의 환자에서 72례의 삼첨판막 치환술을 시행하였으며 이 결과를 토대로 장단기 성적과 위험요인들을 분석하였다. 대상 및 방법: 평균나이는 42$\pm$13세(16~65세)였으며 남여비는 32/39였다. 술전진단은 50례의 후천성판막질환과 18례의 선천성심장질환이 있었고 삼첨판폐쇄부전만 단독으로 있었던 경우도 4례 있었다. 사용된 인공판막은 기계판막이 69개, 조직판막이 3개였다. 승모판막치환술 또는 대동맥판막치환술과 같이 시행된 경우는 50례였고 1례에서는 폐동맥판막 치환술이 같이 시행되었다. 결과: 조기사망은 7례(9.7%), 만기사망은 7례(13.0%)였고 10년 생존율은 59.2$\pm$7.2%였다. 삼천판막혈전증은 5례에서 11번에 결쳐 발생하였으며 그중 1례는 재수술을 시행받았다. 생존자들의 대부분은 심장기능분류 I-II의 상태로 현재까지 외래 추적관찰중이다. 결론: 삼첨판막치환술은 비록 혈전증등의 위험이 상존하기는 하지만 비교적 낮은 사망률과 이환율을 보이고 있으며 기계판막의 경우에도 조직판막과 비교하여 큰 차이 없이 좋은 장기성적을 얻을 수 있었다.

  • PDF

CarboMEdics 기계판막을 이용한 심장판막 치환술의 임상 연구 (Clinical Study of Prosthetic Heart Valve Replacement with CarboMedics.)

  • 장원기;구자홍;조중구;김공수
    • Journal of Chest Surgery
    • /
    • 제33권1호
    • /
    • pp.45-50
    • /
    • 2000
  • Background: The CarboMedics prosthetic heart valve was produced in an attempt to improve the existing valve designs and was especially concerned with easily the implantation and further reduction of turbulence. Precise positioning of the valve in situ was achieved by the abilityof the valve to rotate relative to the sewing ring. Improved monitoring is possible due to increased radiopacity and the dacron sewing ring is coated with carbon to reduce pannus overgrowth. The leaflets have an opening angle of 78 degrees that apparently allows a rapid synchronous closure The aim of this study was to analyze the clinical performance of the CarboMedics valve prostheses(45 mitral 13 aortic and 7 double aortic-mitral valve replacement) were implanted in 65 patients(mean age 48.75$\pm$9.74 years) Result: The operative mortality was 3.1%(2/65) causes of death were low cardiac output syndrome. Total follow up was 1831 patient-months and mean follow up was 29.06$\pm$10.97 months/patient. No structural failure hemorrhage valve thrombosis and late death have been observed. Embolism occurred at a rate of 0.65%/Patient-year. Actuarial survival and thrombo-mbolism free rate at 36 months were 96.9% and 98.4% respectively. Consclusions: The CarboMedics valve stands for low valve related complicatons.

  • PDF

Edwards Duromedics 기계판막엽 탈출 - 1례 보고 - (Valve Leaflet Escape of Edwards Duromedics Mechanical Valve - A Case report -)

  • 윤영남;유경종
    • Journal of Chest Surgery
    • /
    • 제35권1호
    • /
    • pp.60-63
    • /
    • 2002
  • Edwards Duromedics 기계 판막은 1982년 임상적 사용이 시작되었으며, 여러 변화를 거쳐서 현재까지 사용중이다. 기계판막과 관계되는 합병증으로 혈전색전증, 심내막염, 판막부전, 판막염 탈출 및 파손 등이 있으며 판막엽 탈출은 아주 드물게 보고되어 있다. 40세 남자가 1996년 11월 Edwards Duromedic 기계판막(#31,모델9210R)으로 승모판 치환술 및 삼첨판륜 성형술을 시행받은 후 외래 추적관찰 중 1시간 전부터 시작된 급성 호흡곤란을 주소로 응급실에 내원하였다. 심초음파 및 심장 투시촬영상 판막부전으로 진단하여 응급수술을 시행하였다. 수술 중 하나의 기계판막엽이 탈출되어 있는 것을 발견하였으며, 기계판막을 제거하고 St. Jude 기계판막으로 승모판 치환술을 시행하였다. 수술 후 시행한 복부 단층 촬영 및 투시 촬영에서 복부대동맥 분지 부위에서 탈출된 판막엽을 발견하였으며 외래 추적관찰 중 제거를 계획한 후 퇴원하였다.

기계식 一葉심장밸브의 동적거동 해석 (Dynamic Behavior Analysis of Mechanical Monoleaflet Heart Valve Prostheses)

  • 천길정
    • 대한기계학회논문집
    • /
    • 제16권11호
    • /
    • pp.2090-2097
    • /
    • 1992
  • 본 연구에서는 밸브판의 거동을 2차의 회전계로 간주하고, 양력 및 항력(drag force)을 구하는데 있어 Reif등이 구한것과 동일한 방법을 이용하되 정지핀에 의해 그 최대 열림각이 제한을 받는 물리적 사실을 고려하고, 밸브를 통과하는 유량도 단위 입 력이 아닌 정현파(sine wave)로 간주하여 밸브판의 동적거동을 해석하였다. 해석대 상의 밸브 모델로는 Bjork-Shiley 27mm 1엽 밸브를 선정하였다.