• Title/Summary/Keyword: Heart Valve Prosthesis

Search Result 112, Processing Time 0.025 seconds

Hemodynamic Evaluation of St. Jude Medical Prosthesis (센 쥬드 판막의 혈류 역학적 고찰)

  • 문광덕
    • Journal of Chest Surgery
    • /
    • v.28 no.12
    • /
    • pp.1122-1131
    • /
    • 1995
  • One hundred eighty-eight patients[August.23,1988,through July.30,1994 underwent aortic[AVR , mitral[MVR , or double [DVR valve replacement with the St.Jude Medical prosthesis. The author analyzed 100 patients with valvular heart disease,who underwent valve replacement with the St.Jude Medical prothesis from 1990 to 1994, at Hanyang University hospital Cardiovascular department. Information on volume and functional change of the heart chamber can be obtained by cardiac echocardiography and cartheterization. Out of 100 patients, 40 patients were male[40% and 60 patients were female [60% . Age ranged from 13 years to 68 years, with mean age of 42.6 years. Mean height was 160.3cm and mean body weight was 54.9Kg. According to NYHA functional classification, class III is most frequent and 60 patients could be classfied under it. MVR [involved Redo MVR was performed in 40 patients, AVR [involved Redo AVR was performed in 18 patients, and DVR [involved Redo DVR was performed in 42 patients. Warfarin [Coumadin anticoagulation was recommended for all patients. Life long warfarin anticoagulation was necessary to all patients who underwent valve replacement with St.Jude Medical prosthesis. Ideal prothrombin time was maintained about 30% during warfarinization. There were no case of mechanical failure. It followed a comparison of echocardiography before and after valve replacement at Hanyang University hospital [30 patients and a preoperative evaluation of cardiac catheterization and angiography [64 patients . The St.Jude Medical cardiac valve is a viable alternative in the surgical therapy of valvular heart disease.

  • PDF

Clinical Experience of Carbomedics Valve (CarboMedies 기계판막의 임상적 연구)

  • 김병열
    • Journal of Chest Surgery
    • /
    • v.27 no.12
    • /
    • pp.995-1001
    • /
    • 1994
  • The CarboMedics valve prosthesis is a relatively new. low profile bileaflet prosthesis. During a 6 year period from Aug. 1988 to July 1994. 158 patients had CarboMedics prostheses implanted in the mitral [n=94], aortic [n=25], or aortic and mitral [n=39] in National Medical Center. Hospital mortality was 9.4% and the main cause of death was low output syndrome. Follow up was 96% complete, with 365.4 patient-years and a mean follow up of 30 months [ range 1 to 72 months ] . The overall actuarial 6 year survival rate was 91.61 3.47% and actuarial 6year freedom from all valve related complications was 73.9 7.67%. The linearized incidence of vavle related complications was as follows: thromboembolism 1.37%/patient-year ; valve thrombosis 0.82%/ patient-year ; anticoagulant related hemorrhage 0.85%/patient-year ; perivalvular leakage 0.55%/paitent-year: prosthetic valve endocarditis 0.82%/patient-year ; reoperation 1.37%/patient-year. There were no instances of structural failure. We conclude that the Carbomedics valve has a low rate of complications that further improves the quality of life in patients with heart valve prostheses.

  • PDF

Clinical Experience of Carbomedics Prosthetic Heart Valve (Carbomedics 인조 심장판막의 임상적 경험)

  • Jeon, Sang-Hyeop;Kim, Jong-Won
    • Journal of Chest Surgery
    • /
    • v.28 no.9
    • /
    • pp.817-821
    • /
    • 1995
  • The CarboMedics Medical valve has become our mechanical valvular prosthesis of choice because of favorable hemodynamic results that associated with marked clinical improvement and low incidence of thromboembolism after it,s uses. The data for this study was collected from August 1988 to July 1993,five years period. There were total of 57 patients[female 40,male 17 in this series with 4 isolated aortic valve,26 isolated mitral valve,11 double valve and a triple valve replacement. The mean follow up time was 32 months. Postoperatively,58% of cases were in New York Heart Association[NYHA functional class I,and mild and moderate symptoms[NYHA class II were present in 36% and there were very few patients remaining in higher functional classes. In postoperative echocardiographic study, showed marked improved cardiac function. The overall early mortality was 3.5% and the late mortality was one case after triple valve replacement due to sudden death. The causes of early death were attributed to early prosthetic valve endocarditis and heart failure.

  • PDF

Clinical Results of Double Mitral and Aortic Valve Replacement with the St. Jude Medical Prosthesis (쎈트쥬드 중복판막치환의 장기 임상성적)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.28 no.7
    • /
    • pp.666-670
    • /
    • 1995
  • A total of and consecutive 87 patients underwent concomitant double mitral and aortic valve replacement with the St. Jude Medical prosthesis between January 1985 and December 1993. They were 44 males and 43 females with the ages ranging from 18 to 59 years[mean$\pm$SD: 40.9$\pm$9.5 years . Fifteen patients[17.2% had a history of previous cardiac valve replacement. There were 2 early deaths[2.3% , and 85 early survivors were followed up for a total of 352.6 patient-years[mean$\pm$SD: 4.1 $\pm$2.6 years . All were anticoagulated with coumadin keeping the target international normalized ratio within the range of 1.5 and 2.5. There was a single late death[late mortality of 0.284%/patient-year . Thromboembolism was the most frequent complication[1.985%/patient-year , and bleeding related to anticoagulation was experienced in one patient [0.284%/patient-year . The incidences of prosthetic valve endocarditis and of paravalvular leak were also low[0.284%/patient-year, respectively . The survival including operative mortality was 96.1%$\pm$2.2% at 10 years. The actuarial probabilities of freedom from thromboembolism and from all events were 77.9%$\pm$11.1% and 72.4%$\pm$10.7%, respectively, at 10 years. There was no structural failure of the prosthesis. Results from a series of clinical studies suggest strongly that the use of lower intensity of anticoagulation therapy lowers the thromboembolic as well as bleeding rates in patients with the ST. Jude Medical prosthesis.

  • PDF

Design of a Mechanical Artificial Heart Valve Prosthesis Appliing Design Methodology (설계방법론을 이용한 기계식 인공심장판막의 설계)

  • 천길정;류형태
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.291-296
    • /
    • 1998
  • A new mechanical heart valve prosthesis has been designed appling systematic design methodology. The function of the heart valve was defined, and search for design variation has been carried out according to the functional structure, Optimal model among the various variations was determined in view of the design specificationn. Proto type valve was fabricated and test has been carried out using a mock circulation system. It has been observed that the pressure profile, cardiac output and behavior characteristics are generally satisfactory.

  • PDF

Clinical Experiences of St. Jude Medical Cardiac Valve Replacement (St. Jude Medical valve의 임상적 고찰)

  • 김종원
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.518-525
    • /
    • 1992
  • 50 months experience with St-Jude Medical Cardiac Valve Prosthesis The St. Jude Medical valve has become our mechanical valvular prosthesis of choice because of favorable hemodynamic results that associated with marked clinical improvement and low incidence of thromboembolism. The data for this study was collected from April 1986 to May 1990, four years period. There were total of 110 patients[female 53, male 58] in this series with 22 isolated aortic valve, 66 isolated mitral valve, 20 double valve, 2 tricuspid valve replacement. The mean follow up time was 23 months. Postoperatively, 77% of cases were in New York Heart Association[NYHA] functional class I, and mild and moderate symptoms[NYHA II ] were present in 20% and there were very few patients remaining in higher functional classifications. In postoperative echocardiographic study showed marked improved cardiac function. The overall early mortality was 5.4% and was higher after double[13.3%] and mitral valve replacement[5.6%] and the late mortality was one case after mitral valve replacement due to endocarditis. The cause of death in early mortality was attributed to heart failure, acute renal failure, sepsis, etc.

  • PDF

A Structural Analysis on the Leaflet Motion Induced by the Blood Flow for Design of a Bileaflet Mechanical Heart Valve Prosthesis

  • Kwon, Young-Joo;Kim, Chang-Nyung;Lee, Jae-Won
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.9
    • /
    • pp.1316-1323
    • /
    • 2003
  • This paper presents a structural analysis on the rigid and deformed motion of the leaflet induced by the blood flow required in the design of a bileaflet mechanical heart valve (MHV) prosthesis. In the study on the design and the mechanical characteristics of a bileaflet mechanical heart valve, the fluid mechanics analysis on the blood flow passing through leaflets, the kinetodynamics analysis on the rigid body motion of the leaflet induced by the pulsatile blood flow, and the structural mechanics analysis on the deformed motion of the leaflet are required sequentially and simultaneously. Fluid forces computed in the previous hemodynamics analysis on the blood flow are used in the kinetodynamics analysis on the rigid body motion of the leaflet. Thereafter, the structural mechanics analysis on the deformed motion of the leaflet follows to predict the structural strength variation of the leaflet as the leaflet thickness changes. Analysis results show that structural deformations and stresses increase as the fluid pressure increases and the leaflet thickness decreases. Analysis results also show that the leaflet becomes structurally weaker and weaker as the leaflet thickness becomes smaller than 0.6 mm.

Transcatheter Mitral Valve Implantation in Open Heart Surgery: An Off-Label Technique

  • Alfonsi, Jacopo;Murana, Giacomo;Corsini, Anna;Savini, Carlo;Di Bartolomeo, Roberto;Pacini, Davide
    • Journal of Chest Surgery
    • /
    • v.50 no.6
    • /
    • pp.467-470
    • /
    • 2017
  • Extensive mitral annulus calcifications are considered a contraindication for valve surgery. We describe the case of a 76-year-old female with severe mitral and aortic stenosis associated with extensive calcifications of the heart. The patient underwent an open mitroaortic valve replacement using transcatheter aortic valve implantation with an Edwards SAPIEN XT valve (Edwards Lifesciences Corp., Irvine, CA, USA) in the mitral position. The aortic valve was replaced using a stentless valve prosthesis (LivaNova S OLO; LivaNova PLC, London, UK). Postoperative echocardiography showed that the prosthetic valve was in the correct position and there were no paravalvular leaks. A bailout open transcatheter valve implantation can be considered a safe and effective option in selected cases with an extensively calcified mitral valve.

Dynamic Behavior Analysis of Mechanical Bileaflet Heart Valve Prosthesis (기계식 이엽심장밸브의 동적거동 해석)

  • 천길정
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.149-156
    • /
    • 1991
  • In this paper, fluttering behavior of mechanical bileaflet heart valve prosthesis was analyzed taking into consideration of the impact between valve plate and stopper Vibration system of the valve was modeled as a rotating system, and equations are induced by moment equilibrium equations. Lift force, drag force, gravity and buoyancy were considered as external forces acting on the valve plate/ The 4th order Runge-Kutta method was used to solve the equations. Valve plate does not come to the static equilibrium position at a stretch, but come to that position after under damping vibration. Damping ratio increases as the cardiac optput increases, and the mean damping ratio is in the range of 0.16~40.25. Fluttering frequency does not have any specific value, but varies as a function of time. It is in the range of 10~40Hz. Valve opening appears to be affected by the orientation of the of the valve relative to gravitational forces.

  • PDF