• 제목/요약/키워드: Heart Rate Monitoring

검색결과 194건 처리시간 0.033초

A Development of Healthcare Monitoring System Based on Internet of Things Effective

  • KIM, Song-Eun;MUN, Ji-Hui;KIM, Kyoung-Sook;KANG, Min-Soo
    • 한국인공지능학회지
    • /
    • 제8권1호
    • /
    • pp.1-6
    • /
    • 2020
  • The Recently there has been a growing interest in health care due to the COVID-19 situation. In this paper, we intend to develop a healthcare monitoring system to provide users with smart healthcare systems in line with the healthcare 3.0 era. The system consists of a wireless network between various sensors, Android smartphones, and OLEDs using Bluetooth, and through this, a health care monitoring system capable of collecting user's biometric information and managing health by receiving data values of sensors connected to Arduino. In conclusion, the user's BPM value was calculated using the heart rate sensor, and the exercise intensity can be adjusted through this. In addition, a step derivation algorithm is implemented using an acceleration sensor, and calorie consumption can be measured using the step and weight values. As such, the heart rate, step count, calorie consumption data can be transmitted to a smartphone application through a Bluetooth module and output, and can be output to an OLED for users who are not easy to access the smartphone. This healthcare monitoring system can be applied to various groups and technologies.

MISO 필터 기반의 동잡음 모델링을 이용한 심박수 모니터링 (Heart Rate Monitoring Using Motion Artifact Modeling with MISO Filters)

  • 김선호;이정섭;강현일;온백산;백계현;정민규;임성빈
    • 전자공학회논문지
    • /
    • 제52권8호
    • /
    • pp.18-26
    • /
    • 2015
  • 올바른 운동량 조절을 위해선 운동중의 심박수 측정이 중요하다. 최근 스마트 디바이스가 활발하게 사용됨에 따라, 운동중의 실시간 심박수 측정에 대한 관심이 급격하게 증가하고 있다. 고강도 운동 중에는 동잡음으로 인하여 손목 밴드 유형의 광혈류 (PPG : photoplethysmography) 측정기 신호로부터 정확한 심박수를 추정하는 것이 매우 어렵다. 본 논문에서는 손목밴드 유형의 광혈류 측정기 신호로부터 정확한 심박수 추정을 위한 효율적인 알고리즘을 제안하였다. 12개의 데이터 세트에 대하여 제안하는 알고리즘을 적용한 결과, 1.38의 분당심박수(BPM) 평균 절대 오차를 기록하였고, 0.9922의 추정 심박수와 실제 심박수간의 Pearson 상관계수를 얻었다. 제안하는 알고리즘은 웨어러블 디바이스에 적합한 빠른 연산속도와 정확한 추정을 가능케 한다.

최근 소개된 손목형 심박수 측정 장치의 유용성에 관한 연구 (Study on the Validity of Recently Introduced Wrist Watch Type Heart Rate Monitoring Device)

  • 유승훈
    • 대한소아치과학회지
    • /
    • 제41권1호
    • /
    • pp.27-33
    • /
    • 2014
  • 소아 환자가 치과 진료실에서 느끼는 불안감과 공포에 의해 발생하는 스트레스를 측정하기 위한 다양한 방법이 있다. 치료받은 환아나 보호자를 통한 설문을 이용하는 방법과 생체 반응을 측정하는 방법이 가장 많이 사용되고 있다. 스트레스와 관련한 심박수를 측정하는 방법으로 가장 많이 사용하는 것은 포화도 측정기가 있으나 움직이는 소아에게는 적절하지 못한 문제가 있다. 이러한 단점을 극복하기 위해 최근 개발되어 소개된 손목형 심박수 측정 장치(Alpha, MIO, USA)를 포화도 측정기(MP110, MECKIS, Republic of Korea)와 비교하였으며 이를 위해 10명의 성인을 대상으로 안정시와 운동 직후의 심박수를 두 기기를 동시에 장착하여 측정된 데이터를 Wilcoxon Singed Rank test를 시행하였다(p < 0.05). 두 기기에서 측정된 데이터 간의 유의한 차이가 없었다(p < 0.05).

지그비 기반의 휴대형 심전도 모니터링 시스템 설계 (Design of Zigbee based Portable ECG monitoring system)

  • 홍주현;김남진;차은종;이태수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.51-53
    • /
    • 2006
  • This paper proposes a portable ECG monitoring system, which integrates uptodate PDA and RF communication technology. The aim of the study is to acquire the subject's biomedical signal without any constraint. It has two types of transmission mode, which are total signal transmission mode and HR(heart rate)/SC(step count) transmission mode. In audition, wireless communication technology uses Zigbee Wireless PAN and can work in low-power mode, which is one of the advantages of ZiBbee communication technology. The developed system is composed of a transmitter and a receiver. The transmitter has three-axial acceleration sensor. ECG amplifier and Zigbee communication controller. In total signal transmission mode, it can send data 50 packets per second whose transmission speed corresponds to 300 ECG samples and 60 acceleration samples. In HR/SG transmission mode, it can calculate heart rate from EEG data with 216 samples per second and step count from acceleration data and send a packet every cardiac cycle. The receiver forwards the received data to PDA, where the data can be stored and displayed. Therefore, the developed device enables to continuous monitoring for Activities of Daily Living(ADL). Also, this method will reduce medical costs in the aged society.

  • PDF

개인용 컴퓨터를 이용한 전자 태아심음 감시장치의 개발에 관한 연구 (A Study on The Davelopement of Electronic Fetal Heart Rate Monitoring System Using Personal Computer)

  • 정지환;김선일
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권3호
    • /
    • pp.209-214
    • /
    • 1991
  • Digital fetal monitoring system based on the personal computer combined with the digital signal processing (DSP) board was implemented. The DSP board acquires and digitally processes ultra- sound fetal Doppler signal for digital signal conditioning, rectification, low -pass filtering, autocorrealtion function calculation and its peak detection. The personal computer interfaced with the DSP board is in charge of graphic display, hardcopy, data transmission and on -line analysis of fetal heart rate change including on - line warning system, base -line estmation, acceleration, deceleration and variability. It is one of the most suitable situation to apply the DSP chip for siganl conditioning, digital filtering of ultrasound fetal Dopier signal and fetal heart rate estimation using autocorrelation technique .

  • PDF

자전거 운동량 평가를 위한 전도성 직물 기반의 사용자 무구속 심전계 및 스마트폰 어플리케이션 (Unrestrained Electrocardiograph Based on Textile Electrode and Smartphone Application for Assessment of Bicycle Exercise)

  • 황라영;신영은;최우혁;신태민
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.111-118
    • /
    • 2014
  • As assessment of quantitative energy expenditure for effective exercise is becoming more important, many researches about the monitoring system for exercise status or result have been actively carried out. In this case, however, bicycle riders feel restrained and uncomfortable because the riders should wear a belt-type electrocardiograph or a watch-type accelerometer or GPS system during the assessment of bicycle exercise. In this study, therefore, an electrocardiograph based on textile electrode was developed for measuring ECG and calculating heart rate from the bicycle rider without feeling restraint, and smartphone application was also developed for monitoring the heart rate.

Effect of Cellular Phone on Fetal Heart Rate Patterns

  • Jafarabadi, Mina;Jafarabadi, Ladan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.181-184
    • /
    • 2004
  • There are reports showing that electromagnetic fields (EMFs) emitted at non-thermal levels may be associated with biological alterations in target cells. In this study it is objected to assess the potential influences of EMFs produced by cellular phones on fetal heart rate. Non Stress Test (NST) is a widely used method of fetal monitoring and assessing fetal health and well-being. Sixty volunteers with uncomplicated term pregnancies were studied by a Spacelabs AM-67 Doppler ultrasound monitor. Fetal Heart Rate recordings were obtained while there were no Cellular Phone around for 10 minutes. Afterwards, all patients were exposed to EMFs for 10 minutes. NST was performed while they were holding the CP on stand-by mode and then on dialing mode, each for 5 minutes. The recordings were analyzed with respect to baseline heart rate, accelerations and decelerations. The Wilcoxon matched-pairs signed-ranks test was used to compare these variables. The results indicate that EMFs emitted by CP do not cause any demonstrable effects on baseline FHR, acceleration or deceleration.

  • PDF

착용형 심장활동 모니터링 시스템을 활용한 정신적 스트레스 평가 (The Assessment of Dynamic Mental Stress with Wearable Heart Activity Monitoring System)

  • 김경섭;신승원;이정환;최희정
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.1109-1115
    • /
    • 2008
  • In the ubiquitous health monitoring environments, it is quite important not only to evaluate the physiological health condition but also mental stress condition. In order to achieve this goal, a heart activity monitoring system utilizing a wearable bipolar electrode is devised and the heart rate variability(HRV) is extracted and interpreted in both frequency and time feature domains. Consequently, to evaluate the emotional stress condition of the subjects, a stress-induced experimental protocol was applied to healthy subjects and the time and frequency features of heart activity were analyzed in terms of the ratio of low frequency components v.s., high frequency components and the relevant the moving average distributions compromising the successive RR peaks intervals in the ambulatory ECG measurement system.

감각적 자극에 따른 신생아 반응에 관한 연구 -심박동수를 중심으로- (A Study of the influence of stimulus on newborn infant생s response -Specifically in heart rate change-)

  • 이자형;하영수
    • 대한간호학회지
    • /
    • 제13권3호
    • /
    • pp.119-126
    • /
    • 1983
  • Early extra-uterine development of the newborn infant has the potential for clarifying important questions of nature and care taking environment. In this study, tactile and auditory stimulation is used on .a group of infants to determine the effects of their response. Infants were tested by EKG at 24∼48 hrs after birth ana all they are free from complication. Stimuli presented were-touch and sound (40dB, 70dB and 40∼70dB). The result of the study were as follows: 1) The heart rate was seen to depend on their sleep-wake state. (light sleep ; 125/min, eyes: open & motor activity increase ; 151/min crying ; 185/min). 2) The heart rate affected by tactile & auditory stimulus. The heart rate response was acceleration above the prestimulus level. (tactile, 231min increase, auditory ; 16∼21/min increase), and heart rate change was seen to depend on prestimulus rate. (γ=.73) 3) There was a decrease in heart rate when they were soothe. (touch ; 24.8sec, 21/min decrease, pacifier ; 14.5sec, 26/min decrease) and significant difference in time between touch and pacifier (t= 1.76, p<0.05). This result support the evaluation of newborn infant's sensory abilitics, and has even begin to influence changes in nursing care. But systemic monitoring of newborn infants response would. further define.

  • PDF

손목형 심박수 측정 장치를 이용한 어린이의 치과진료 시 스트레스 평가 (The Assessment of Stress of Children under Dental Procedures Using Wrist Watch Type Heart Rate Monitoring Devices - Using New Device for Stress Assessment in Children During Restorative Dental Treatment)

  • 오정은;김종수;유승훈
    • 대한소아치과학회지
    • /
    • 제42권2호
    • /
    • pp.119-125
    • /
    • 2015
  • 치과 의사는 어린이들이 치과에서 받는 스트레스로 인해 행동 관리에서 어려움을 주로 겪게 된다. 스트레스에 대한 평가는 생체적 표지자인 심박수를 이용하는 방법이 유용하게 사용되고 있다. 본 연구는 치과에서 침윤 마취를 행한 후 이루어지는 수복 진료에서 아이들이 받는 스트레스 정도를 손목형 심박수 측정 장치를 사용하여 알아보기 위해서 계획되었다. 첫 치과 치료를 받은 어린이에서 심박수 변화는 국소 마취 단계에서 가장 높게 나타났으며, 심박수는 치아 삭제에서 가장 높았으나, 단계별 유의한 차이는 관찰되지 않았다(p > 0.05). 이 중 3회 내원하여 치료를 마무리한 어린이에서는, 두 번째 내원의 심박수가 첫 번째 내원과 세 번째 내원에 비해 유의하게 높았으며(p < 0.05), 첫 번째와 세 번째 내원의 심박수는 유의한 차이가 관찰되지 않았다(p > 0.05). 기존 치과 진료 경험이 없는 환아는 국소 마취를 포함한 치과 진료 시 두 번째 내원에서 스트레스를 많이 받는 것으로 생각되며, 치과의 진료 환경에 익숙해지려면 적어도 3회 이상의 내원이 필요할 것으로 생각된다.