• Title/Summary/Keyword: Hearing screening

Search Result 62, Processing Time 0.021 seconds

Effectiveness of Computer-Animated Pure Tone Audiometry for Screening (애니메이션을 이용한 순음청력선별검사 도구의 효용성에 대한 연구)

  • Kim, Young-Min;Lee, Moo-Kyung
    • Phonetics and Speech Sciences
    • /
    • v.2 no.3
    • /
    • pp.151-156
    • /
    • 2010
  • The purpose of this study was to develop a computer-animated pure tone audiometry for screening (CAPTAS) for toddler and to determine its validity and reliability. The CAPTAS utilizes an animated cartoon story producing visual and auditory stimuli. The intensities were 40 dB, 60 dB, 80 dB. The frequencies were 500 Hz, 1000 Hz, 2000 Hz, and 4000 Hz. The subjects were 20 (9 males and 11 females) severely hearing impaired children. As a result, The correlation coefficient between mean hearing threshold of children who were able to perform PTA and average hearing threshold of CAPTAS was performed and it revealed CAPTAS's high validity. And to verify the reliability of the re-test, all children had the CAPTAS and repeated it periodically. The result confirmed the reliability.

  • PDF

Investigation of Automated Neonatal Hearing Screening for Early Detection of Childhood Hearing Impairment (소아 난청의 조기진단을 위한 신생아 청력 선별검사에 대한 평가)

  • Seo, Jeong Il;Yoo, Si Uk;Gong, Sung Hyeon;Hwang, Gwang Su;Lee, Hyeon Jung;Kim, Joong Pyo;Choi, Hyeon;Lee, Bo Young;Mok, Ji Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.706-710
    • /
    • 2005
  • Purpose : Early diagnosis of congenital hearing loss through the neonatal hearing screening test minimizes language defect. This research intends to identify frequency of congenital hearing loss in infants through neonatal hearing screening test with the aim of communicating the importance of hearing test for infants. Methods : From May 20, 2003 to May 19, 2004, infants were subjected to Automated Auditory Brainstem Response test during one month of birth to conduct the test with 35 dB sound. Infants who passed the 1st round of hearing test, were classified into 'pass' group whereas those who did not were classified into 'refer' group. Infants who did not 'pass' in the hearing test conducted within one month of birth were subjected to re-test one month later, and if classified as 'refer' during the re-test, they were subjected to the diagnosis for validation of hearing loss by requesting test to the hearing loss clinic. Results : There was no difference among the 'pass' and 'refer' group in terms of form of childbirth, weight at birth and gestational age. In the 1st test, total of 45 infants were classified into 'refer' group. Six among 35 who were subjected to re-test(17%) did not pass the re-test, and all were diagnosed with congenital hearing loss. This corresponds to 0.35%(3.5 per 1,000) among total number of 1,718 subjects. Conclusion : In our study the congenital hearing loss tends to be considerably more frequently than congenital metabolic disorder. Accordingly, newly born infants are strongly recommended to undergo neonatal hearing screening test.

Application of HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version) to screening test of noise-induced hearing loss (소음성 난청 선별검사에 HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version)의 적용)

  • Lee, Mi-Young;Suh, Suk-Kwon;Lee, Choong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.539-553
    • /
    • 1996
  • The study was conducted from May to September in 1994 to investigate applicability of the Hearing Handicap Inventory for the Elderly-Screening version(HHIE-S) in parallel with the pure-tone audiometer to the initial screening test of noise-induced hearing loss(NIHL) in some noise-exposed workers. Subjects were selected by systemic sampling that took every 10th person from 6, 700 workers taking the annual occupational health examination by the department of Health Maintenance of Dongsan Hospital Keimyung University in Taegu. The authors administered the pure-tone audiometric test and self-reported questionnaire of HHIE-S including items of sociodemographic and job-related variables concurrently. The final subjects analysed were 1,019(488 males and 531 females) excluding fourteen persons who had many missing values in their questionnaires. The reliability coefficients of HHIE-S scale by Cronbach's alpha were 0.84. In the univariate analysis of hearing handicap measured by the HHIE-S, work duration, military service and the hearing threshold loss at 1KHz and 4KHz by the initial audiometer were significant in males while age, work duration and hearing threshold loss at 1KHz and 4KHz were significant in females. In the stepwise linear regression analysis, hearing threshold loss at 1KHz and 4KHz, was the only selected variable explaining the hearing handicap in males and hearing threshold loss at 1KHz and 4KHz, age, and work duration were selected in females. In ROC curves for HHIE-S scores against NIHL as gold standard which was defined by the follow-up audiogram as more than 30dB of the average of 0.5/1/2KHz and 50dB at 4KHz, the optimal cutoff for the parallel HHIE-S appeared to be 8. The results suggest that HHIE-S appeared to have some reliability and validity in this data and might be used in screening NIHL in parallel with pure-tone audiometer in noise-exposed workers.

  • PDF

Comparison of Human Responses to Transportation Noise in Monaural and Binaural Hearing, Part II: Annoyance (교통소음의 모노럴과 바이노럴 청감 비교 연구 II: 성가심)

  • Kim, Jaehwan;Lim, Chang-Woo;Hong, Jiyoung;Jeong, Wontae;Cheung, Wansup;Lee, Soogab
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1279-1286
    • /
    • 2004
  • This paper continues companion paper, part I : measurement and analysis. As shown in companion Paper, information and energy in monaural signal is quite different from that of binaural signal. In this paper, difference between monaural and binaural signal of transportation noise are investigated in subjective response test. We executed hearing screening test before giving a subject response test and excluded subjects who had physical hearing loss. An annoyance response test was conducted using headphone to avoid cross-talk effect in binaural testing. Percentage of highly annoyed under binaural signal reproduction is higher than percentage of highly annoyed under monaural signal reproduction. Result implies binaural reproduction technique is proper for a study of human response to short-term noise exposure in a headphone simulated-environment.

Neonatal Hearing Screening in Neonatal Intensive Care Unit Graduate (신생아 집중치료실 퇴원아의 신생아 청력 선별검사)

  • Cho, Sung-Hee;Kim, Han-A;Kim, El-Len A.;Chung, Jong-Woo;Lee, Byong-Sop;Kim, Ki-Soo;Pi, Soo-Young
    • Neonatal Medicine
    • /
    • v.16 no.2
    • /
    • pp.213-220
    • /
    • 2009
  • Purpose: Hearing loss is one of the common birth defects in humans, with a reported prevalence of 1-3 per 1000 newborns. We investigated the incidence of hearing loss and evaluated the use of neonatal hearing screening test in neonatal intensive care unit (NICU) graduates who are at greater risk for hearing loss than normal newborns. Methods: The neonates admitted to the NICU of Asan Medical Center from 1 March, 2003 to 30 March, 2008 who were available for follow-up were included. Those who failed the first auditory brainstem response prior to discharge were retested with the stapedial reflex test, auditory brainstem response and tympanometry in the Otolaryngology department. Results: Of 2,137 neonates, 2,000 (93.5%) neonates were tested prior to discharge. Sixty-seven neonates (3.4%) failed the first newborn hearing screening test. Of 67 infants, 52 infants were retested for a second hearing test. Excluding 10 infants (19.2%) who were lost during follow-up, 16 infants were confirmed to have hearing impairment of which 12 and 4 infants had unilateral and bilateral hearing loss, respectively. Of 16 infants, 5 did not meet the criteria set by the Korean National Health Insurance Corporation. Conclusion: The prevalence of hearing impairment in NICU graduates is about 0.8%, excluding those who were lost for follow up, necessitating a systemic and effective hearing assessment program among these high risk infants and more generous national insurance coverage.

The Correlation of the Hearing Handicap Inventory for the Elderly and Berg Balance Test-Korean Version (노인의 청력장애지수와 한국판 버그균형검사의 상관관계)

  • Cho, Gyu-Hang;Hwang, Su-Jin
    • PNF and Movement
    • /
    • v.8 no.1
    • /
    • pp.51-58
    • /
    • 2010
  • Presbycusis or related-age hearing loss is approximately 30 percent for people aged over 65 years. The purpose of this study was to compare the relationship between the Hearing Handicap Inventory for the Elderly and the Berg Balance Scale for predicting and screening risk of falls in people over 65 years with diagnosed presbycusis. Thirty-five subjects all lived at the nursing home in Wonju. Disability caused presbycusis was measured using the Hearing Handicap Inventory for the Elderly, and static and dynamic balance was measured using Berg Balance Scale. Data were analyzed using Spearman correlation. Statistically significant differences were noted between two clinical meausres (r=.862, p<0.001). In conclusion, the results suggest that presbycusis may be able to predict dangerous falls in older persons.

  • PDF

The quality of life of elderly people with hearing loss selected by Hearing handicap inventory for elderly (HHIE) (Hearing handicap inventory for elderly(HHIE)로 선별한 난청 노인들의 삶의 질)

  • Lee, Hyun-Jung;Heo, Seung-Deok;Hwang, Soo-Yeon
    • Journal of Korean Academy of Medicine & Therapy Science
    • /
    • v.10 no.2
    • /
    • pp.39-45
    • /
    • 2018
  • Objective: The aimes of this study is to analyze the effects of presbycusis on the quality of life. Method: 47-elderly were participated. The participants were divided into the suspected hearing impaired group (N=18) and the within normal limits (WNL) group (N=29). One-way ANOVA was performed to determine the association between the HHIE and WHOQOL-BREF scores by age group, and independent t-test was carried out to analyze the inter-group relations. Results: The scores in WHOQOL-BREF differed significantly by age group (p=.011): people in their sixties scored $3.7{\pm}.62$, those in their seventies $3.3{\pm}.56$, and those in their eighties $2.8{\pm}.60$, with significant differences observed. There were statistically significant inter-group differences (p=.000), with significant differences observed. Conclusion: The quality of life of the elderly were lowered depending on age and hearing impairment.

Development of A-ABR system for identifying difficulty in hearing (난청 감별을 위한 자동청성뇌간반응검사(A-ABR) 측정기 개발)

  • No, Hyung-Wook;Kim, Soo-Chan;Cha, Eun-Jong;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.141-142
    • /
    • 2008
  • Hearing loss is the most common birth defect among infants. Yet most hearing-impaired children are not identified until 1 to 3 years of age - which is well beyond the critical period(6 month) for healthy speech and language development. However, if a hearing-impairment is identified and treated in its early stages, child's speech and language skills will be comparable to his or her normal- hearing peers. For these reasons, hearing screening at birth and routinely throughout childhood is extremely important. Auditory brain-stem response(ABR) is nowadays one of the most reliable diagnostic tools in the early detection of hard of hearing. In this study, we developed the system that detects auditory evoked potential using micro-processor. Furthermore, it is required to develop a portable system to measure in not only soundproof room but also nursery for infants.

  • PDF

IoT based Pure Tone Audiometer with Software Platform Compatibility (IoT 기반의 소프트웨어 플랫폼 호환성을 갖는 순음청력 검사기)

  • Kang, Sung Ho;Lee, Jyung Hyun;Kim, Myoung Nam;Seong, Ki Woong;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.2
    • /
    • pp.261-270
    • /
    • 2018
  • Hearing-impaired people are increasing rapidly due to the global aging trend. Early detection of hearing loss requires an easy-to-use audiometry device for the public. Existing audiometry systems were developed as PC-based, PDA-based, or smartphone apps. These devices were often dependent on specific software platforms and hardware platforms. In this paper, we tried to improve software platform compatibility by using cross platform, and tried to implement IoT-based pure tone audiometry device which does not require sound pressure level correction due to hardware differences. Pure tone audiometry is available in a variety of ways depending on the type of hearing loss and age. Using the IoT-based audiometry device implemented in this paper, it will be possible for an app developer who lacks hardware knowledge to easily develop an app with various scenarios for hearing screening. The results of this study will contribute to overcoming the software and hardware dependency in the development of IoT-based healthcare device.

Current Status of Health Screening in Korea (한국의 건강검진 현황)

  • Jo, Han-Ik
    • Journal of Korea Association of Health Promotion
    • /
    • v.2 no.3
    • /
    • pp.73-96
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items and methods should be carefully selected. This study was to get hold of the test items of major health screening programs in Korea Most of the health screening programmes focused upon detection of risk factors and diagnosis of life - style related diseases (diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis) ,cancers (stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus) , infectious diseases (hepatitis, tuberculosis, sexually-transmitted diseases, parasites) , chronic obstructive respiratory diseases, chronic renal diseases (bacteriuria hematuria, proteinuria) , anemia, glaucoma, hearing loss, Alzheimer disease, stress, early psychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests (CBC, urinalysis, liver function tests, lipid tests, glucose, HbAlc, uric acid, electrolytes, serological tests (HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray (chest PA, CT) , endoscopy (gastroscopy, colonoscopy) , sonography(abdomen, thyroid, pelvis, breast) ,cytology (cervix) , bone density, tumor markets (NMP22, alpha-FP, CEA, CA-19-9, CA12S, PSA) and eye tests. Advanced technologies, like CT, PET, MRI, MRT/Angio, molecular testings) were widely used in hospital health screening programmes .In summary, a variety of tests were utilized in health screening in Korea. Those tests were utilized by stages or according to sex and age in most of health screening programmes, however a few program used tests to excess disregarding health screening subjects.

  • PDF