• Title/Summary/Keyword: Healthy adults

Search Result 1,420, Processing Time 0.032 seconds

Effect of Tiger Step on Lower Extremities during Uphill Walking (오르막보행 시 타이거스텝 하지 움직임에 미치는 영향)

  • Kang, Jihyuk;Yoon, Sukhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.1
    • /
    • pp.17-23
    • /
    • 2022
  • Objective: The aim of this study was to investigate the effect Tiger-step walking on the movement of the lower extremities during walking. Method: Twenty healthy male adults who had no experience of musculoskeletal injuries on lower extremities in the last six months (age: 26.85 ± 3.28 yrs, height: 174.6 ± 3.72 cm, weight: 73.65 ± 7.48 kg) participated in this study. In this study, 7-segments whole-body model (pelvis, both side of thigh, shank and foot) was used and 29 reflective markers and cluster were attached to the body to identify the segments during the gait. A 3-dimensional motion analysis with 8 infrared cameras and 7 channeled EMG was performed to find the effect of tigerstep on uphill walking. To verify the tigerstep effect, a one-way ANOVA with a repeated measure was used and the statistical significance level was set at α=.05. Results: Firstly, Both Tiger-steps showed a significant increase in stance time and stride length compared with normal walking (p<.05), while both Tiger-steps shown significantly reduced cadence compared to normal walking (p<.05). Secondly, both Tiger-steps revealed significantly increased in hip and ankle joint range of motion compared with normal walking at all planes (p<.05). On the other hand, both Tiger-steps showed significantly increased knee joint range of motion compared with normal walking at the frontal and transverse planes (p<.05). Lastly, Gluteus maximus, biceps femoris, medial gastrocnemius, tibialis anterior of both tiger-step revealed significantly increased muscle activation compared with normal walking in gait cycle and stance phase (p<.05). On the other hand, in swing phase, the muscle activity of the vastus medialis, biceps femoris, tibialis anterior of both tiger-step significantly increased compared with those of normal walking (p <.05). Conclusion: As a result of this study, Tiger step revealed increased in 3d range of motion of lower extremity joints as well as the muscle activities associated with range of motion. These findings were evaluated as an increase in stride length, which is essential for efficient walking. Therefore, the finding of this study prove the effectiveness of the tiger step when walking uphill, and it is thought that it will help develop a more efficient tiger step in the future, which has not been scientifically proven.

Correlation between Isokinetic Parameters of Knee Joint and Lower Extremity Function (무릎관절의 등속성 변수와 하지 기능의 상관관계)

  • Lee, Se-yun;Park, Jong-hyun;Jeon, Jeongwoo;Hong, Jiheon;Yu, Jaeho;Kim, Jinseop;Lee, Dongyeop
    • Journal of Advanced Technology Convergence
    • /
    • v.1 no.1
    • /
    • pp.33-42
    • /
    • 2022
  • The flexors and extensors of the knee joint are essential for maintaining body stability. The purpose of this study was to investigate the correlation between the isokinetic parameters of the knee flexor and extensor muscles and the function of the lower extremity muscles. Twenty-two healthy adults participated in this study. The time to peak torque (TTP), acceleration time (AT), and peak torque (PT) of the knee flexor and extensor muscles were measured. A 20m sprint, Sargent jump, one leg hop test, and side shuffle were measured to evaluate lower extremity function. The correlation between each variable was analyzed using Pearson correlation coefficient. PT of the knee flexor showed a significant correlation with single leg hops and 6M hops in a single leg. PT of knee extensors was found to be significantly correlated with Sargent jumps and triple hops. Based on the results of this study, we suggest that the strength of the knee flexor and extensor muscles has the potential to be used to predict lower extremity function.

Lifestyle changes and perceived restrictions in daily life during the COVID-19 pandemic: Analysis of the 2020 Community Health Survey data (COVID-19 판데믹 시기 라이프스타일 변화와 일상생활 제한인식: 2020년 지역사회건강조사자료 분석)

  • Song, Inmyung
    • Journal of Industrial Convergence
    • /
    • v.20 no.8
    • /
    • pp.109-118
    • /
    • 2022
  • This study aims to examine the extent of lifestyle behavior changes, perceived restrictions in daily life, and their relationship during the COVID-19 pandemic. Using the 2020 Community Health Survey data, this study calculated perceived restrictions in daily life among adults in Korea during the pandemic by sociodemographic characteristics and lifestyle behavior category (physical activity, sleeping duration, drinking, smoking, social contact, public transport use, food delivery, instant food consumption). The generalized linear model examined the relationship between behavior change and perceived restriction on daily life. A total of 227,808 respondents were analyzed. 56.70% of the population perceived their daily lives restricted by 50% and more during the pandemic. The majority of the population decreased physical activity, social contact, and public transport use (52.71%, 89.70%, and 63.74%, respectively). Individuals who decreased physical activity, sleep duration, and social contact frequency, and those who increased drinking frequency, food delivery, and instant food consumption perceived greater restrictions in daily life than those who did not change respective behaviors (p<0.001). In conclusion, decreases in social contact and physical activity and increases in use of food delivery and instant food consumption were associated with greater perceived restrictions of daily life during the pandemic. Efforts to alleviate the negative impact of the pandemic on psychological well-being may need to involve attempts to improve healthy life behaviors.

Reliability Analysis of Finger Joint Range of Motion Measurements in Wearable Soft Sensor Gloves (웨어러블 소프트 센서 장갑의 손가락 관절 관절가동범위 측정에 대한 신뢰도 분석)

  • Eun-Kyung Kim;Jin-Hong Kim;Yu-Ri Kim;Ye-Ji Hong;Gang-Pyo Lee;Eun-Hye Jeon;Joon-bum Bae;Su-in Kim;Sang-Yi Lee
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose: The purpose of this study was to compare universal goniometry (UG), which is commonly used in clinical practice to measure the range of motion (ROM) of finger joints with a wearable soft sensor glove, and to analyze the reliability to determine its usefulness. Methods: Ten healthy adults (6 males, 4 females) participated in this study. The metacarpophalangeal joint (MCP), interphalangeal joint (IP), and proximal interphalangeal joint (PIP) of both hands were measured using UG and Mollisen HAND soft sensor gloves during active flexion, according to the American Society for Hand Therapists' measurement criteria. Measurements were taken in triplicate and averaged. The mean and standard deviation of the two methods were calculated, and the 95% limits of agreement (LOA) of the measurements were calculated using the intraclass correlation coefficient (ICC) and Bland-Altman plot to examine the reliability and discrepancies between the measurements. Results: The results of the mean values of the flexion angles for the active range of motion (AROM) of the finger joints showed large angular differences in the finger joints, except for the MCP of the thumb. In the inter-rater reliability analysis according to the measurement method, the ICC (2, 1) value showed a low level close to 0, and the mean difference by the Bland-Altman plot showed a value greater than 0, showing a pattern of discrepancy. The 95% LOA had a wide range of differences. Conclusion: This study is a preliminary study investigating the usefulness of the soft sensor glove, and the reliability analysis showed a low level of reliability and inconsistency. However, if future studies can overcome the limitations of this study and the technical problems of the soft sensor glove in the development stage, it is suggested that the measurement instrument can show more accurate measurement and higher reliability when measuring ROM with UG.

Effects of Wearing Toe Braces of Hallux Valgus on Gait during Virtual Environment Simulation (무지외반증 발가락 교정기 착용 여부가 가상 환경 시뮬레이션 시 보행에 미치는 영향)

  • Dong-Su Kim;Da-Eun Lee;Hyun-A Shin;Ji-Won Jeon;Young-Keun Woo
    • PNF and Movement
    • /
    • v.21 no.1
    • /
    • pp.27-35
    • /
    • 2023
  • Purpose: Hallux valgus (HV) is one of the most common chronic foot disorders, occurring when the first toe deviates laterally toward the other toe. HV impairs muscle strength and affects gait function (postural sway and gait speed). Thus, this study aims to investigate using the FDM system the effect of wearing braces on gait while wearing a virtual reality (VR) device. Methods: This study was conducted on 28 healthy adults with HV of 15 degrees or more. To compare differences in walking, depending on whether a toe brace can be worn, the subject walked without wearing anything, walked after wearing the VR device, and walked after wearing the VR device and the toe brace, and the FDM system was used for the gait ability measurement analysis. Results: As a result of a one-way repeated analysis of variance, the walking speed-related variables (cadence, velocity, etc.) in the HV group were higher during comfortable walking. In addition, walking while wearing a VR device and walking while wearing a VR device and a toe brace demonstrated more significant values in terms of six gait parameters (double stance phase, loading response, stage, stage, stage, and stage). The maximum pressure of the forefoot was significantly reduced when walking while wearing a VR device and a toe brace compared to comfortable walking, but in all variables, there was no statistically significant difference between walking while wearing a VR device and walking while wearing a VR device and a toe brace. Conclusion: Orthosis with a VR device during gait (OVG) and gait with a VR device (GVR) affect gait in HV patients. However, there was no significant difference between GVR and OVG. Thus, it is necessary to conduct experiments on various HV angles and increase the duration of wearing the toe brace.

Effect of Aerobic Exercise using Bruce Protocol on Heart Rate, Oxygen Saturation, and Blood Pressure after Recovery from COVID-19 Infection (COVID-19 이환자의 브루스 프로토콜을 이용한 유산소 운동이 심박수, 산소포화도, 혈압에 미치는 영향)

  • Yeon-Seop Lee;Seung-Soo Yang;Seul-Gi Jang;Ji-Hee Seol;Ji-Eun Lee;Dong-Jin Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.2
    • /
    • pp.141-147
    • /
    • 2023
  • Purpose : This study aimed to find out the effect of aerobic exercise using Bruce protocol on heart rate, oxygen saturation, and blood pressure after recovery from COVID-19 infection. Methods : In this study, 34 students from D University located in J city were targeted, COVID-19 infected group (17 people) and non-COVID-19 non-infected group (17 people). The Bruce protocol using a treadmill was applied to the aerobic exercise of this study. The Bruce protocol has in the first stage of METs 4 (slope 10 %, speed 2.7 km/h). The second stage was METs 5 (slope 12 %, speed 4 km/h), and the third stage was METs 6 (slope 14 %, speed 5.4 km/h). All measurements were measured 3 times and the average value was used. Results : As a result of this study, as a result of comparing heart rate changes according to aerobic exercise using the Bruce protocol. EG group and the CG group increased significantly according to the progressive exercise load (METs 4~5), and in the third stage of the Bruce protocol between groups, The EG group showed a significantly lower heart rate. As a result of comparing changes in oxygen saturation and blood pressure, there was no significant difference between the EG and C groups according to the gradual exercise load. Conclusion : In conclusion, there was no difference between normal and pressure when MET of moderate intensity exercise (4 to 6) was applied to the effect on heart rate, oxygen saturation, and blood pressure in healthy adults who were fully recovered from COVID-19. Secondary side effects may occur when high intensity exercise with a MET of 6 or higher, so it is strongly recommended that hospitals or specialized institutions measure exercise and physical ability according to individual exercise intensity.

Effects of Mattress Material Change on Sleep Quality: An Exploratory Study (매트리스 소재변화가 수면의 질에 미치는 영향: 탐색적 연구)

  • Su-Eun Lim;Ki-Hyun Park;Young-Hwa Baek;Si-Woo Lee;Se-Jin Park;Ho-Ryong Yoo;Kwang-Ho Bae
    • Science of Emotion and Sensibility
    • /
    • v.25 no.4
    • /
    • pp.95-106
    • /
    • 2022
  • This study evaluated the effects of latex mattresses on sleep quality and comfort. The participants were 11 healthy adults (five males, six females, mean age 37.7 years, mean height 167.8 cm, and mean weight 67.0 kg) without severe insomnia or other disease that could affect sleep, examined by a clinician. In their personal living space, participants slept on a spring mattress for 7 days, with their sleep registered using a wearable device (Fitbit), a sleep log, the Pittsburgh Sleep Quality Index (PSQI), the Insomnia Severity Index (ISI), and a satisfaction survey. The mattresses were then replaced with latex mattresses, which were used for 14 days. As a result, sleep time increased by 62.9 min on weekdays and 53.2 min on weekends after using the latex mattress, and a significant decrease, of 3.8, as seen on the ISI. As measured by the PSQI, the poor sleepers decreased from 10 to 7, but this was not statistically significant, and in the satisfaction survey, the comfort of the low back, neck, and shoulders was significantly increased. This suggests that changes to latex mattresses may positively affect objective and subjective sleep quality.

Correlation Analysis of Clinical Risk Factors and Atherosclerosis Diagnosed by Carotid Artery Ultrasonography (경동맥 초음파로 진단된 죽상동맥경화증과 위험인자의 관련성 분석)

  • Jee-Yeon Park;Sung-Hee Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.465-472
    • /
    • 2023
  • In predicting vascular disease, this study attempted to identify changes in the carotid intima-media thickness in patients who underwent carotid artery ultrasonography and hematological tests and to find out the effect of risk factors on the expression of atherosclerotic plaque. A retrospective analysis was conducted on 469 healthy adults who visited the hospital for the purpose of medical examination and performed carotid artery ultrasonography. As a result, carotid intima-media thickness, age, body mass index, waist circumference, systolic blood pressure, total cholesterol, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol and glucose were analyzed as significant predictors of atherosclerotic plaque (p<0.001). The risk ratio was calculated based on the cut off value of the risk factors of the atherosclerotic plaque determined through ROC curve analysis, followed by 8.06 times the carotid intima-media thickness, 7.53 times the age, 3.97 times the waist circumference and 2.02 times the glucose. Therefore, in this study it was possible to prepare a Korean standard for clinical risk factors that affect the presence of absence of atherosclerotic plaque and observation of carotid artery ultrasonography is thought to help diagnose or predict cardiovascular disease early.

Comparison of the nutrition quotient by types of eating behavior among male and female university students in Gwangju (광주 지역 남녀 대학생의 섭식 행동 유형별 영양 지수의 비교)

  • Geum-Bi Ryu;Young-Ran Heo
    • Journal of Nutrition and Health
    • /
    • v.56 no.3
    • /
    • pp.277-287
    • /
    • 2023
  • Purpose: This study was conducted to investigate the eating behavior (EB) and nutritional status of university students in Gwangju, and to compare their nutrition quotients (NQs) and problems according to their EB types. Methods: The subjects were 219 (127 female and 92 male) undergraduate students from Gwangju. The Student's t-test was used to compare the EB levels according to gender, and Pearson's χ2 test was used to compare the distribution of EB types by gender. A gender-adjusted analysis of covariance (ANCOVA) was conducted to examine the difference in NQs by EB types. Results: First, there were significant differences in the EB scores and the distribution of EB types according to gender. Female students showed higher levels of emotional (Emo) and external (Ext) EBs than the male students, and Emo, Ext, and combined (Com) EB types were more evident among female rather than male students. Second, there was a difference in NQs according to the EB types. The Emo EB type subjects had a lower NQ than those of the restrained (Res) EB type and showed significant differences in diversity and dietary behavior. Specifically, the Emo EB type subjects displayed significantly lower efforts to maintain a healthy diet and subjective health status than the Com EB type and their levels of checking nutrition labels, hand washing, and water intake were significantly lower than that of the Res EB type. The Ext EB type showed significantly lower moderation of Ramyeon and sweetened drink intake than the Res and Com EB types. Conclusion: The level of EBs and the distribution of EB types varied according to gender, and the NQs were different according to EB types. The results of this study are expected to contribute to the establishment of customized strategies for improvement by identifying major nutritional problems by gender and the EB types of university students.

Evaluation of the proximal contact and comparison of methods for measuring in normal dentition (건강한 자연치열에서 인접면 접촉의 평가 및 측정방법에 따른 비교분석)

  • Ji-Eun Kim;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.198-203
    • /
    • 2023
  • Purpose. The aim of this study was to evaluate the proximal contact with a dental floss compared to a celluloid strip and a metal strip in normal dental arch and investigate what the most effective method for measuring is. Materials and methods. The subjects of this study was consisted with 20 healthy adults (10 males and 10 females) who had normal dentition. A dentist with more than 5 years of clinical experience evaluated the proximal contacts using a dental floss method, a celluloid strip method, and a metal strip method. Statistical analysis were performed by the use of Mann-Whitney U test. A P-value < .05 was considered statistically significant in all analysis. In addition, in the evaluation of proximal contact using a dental floss, the measurement of proximal contact using a celluloid strip and a metal strip was compared. Results. 80 % of all proximal contact was proper. Proper proximal contact was observed at the posterior area compared to the anterior area (P < .05). And male had proper proximal contact at the anterior area, female had proper proximal contact at the posterior area (P < .05). The consistency analysis between the results of the celluloid strip and the metal strip experiment on the results obtained from the floss using the consistency scale Kappa index shows that using celluloid strip is more advantageous than using the metal strip. Conclusion. Only 80% of all proximal contact was proper. Using celluloid strips with various thickness for evaluating of proximal contact is considered to be helpful for accurate measuring of proximal contact.