• Title/Summary/Keyword: Health mask

Search Result 182, Processing Time 0.019 seconds

Development of a Low Noisy Type of Air-line Mask (저소음형 송기마스크 개발)

  • Paik, Eun-Gyu;Kim, Bong-Nyun;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.277-281
    • /
    • 2005
  • Air-line mask is an important personal protective equipment for workers working under hazardous surroundings in which a fixed ventilation system is difficult to be installed. If the air-line mask make loud noise, works wearing the mask may be faced with health problems such as noise induced hearing loss(NIHL). The purpose of this study is to introduce a low noisy technology for workers using air-line mask. A traditional type air-line has been improved to an advanced air-line mask with lesser noise. In the mask, air suppling conduits consists of multi tubes are placed inside of the front of the safety helmet. The noise level reduced from 80dB(A) to less than 80dB(A) when measured by KS A 0701 method at Center for Safety Inspection, Testing and Certification for KOSHA. It is suitable for related regulation[Article 35 of the Industrial Safety and Health Act(Test of Personal Protective Equipment)]. While workers working in noise level of over 90dB(A), they may expose to 82dB(A) or less when they wear the advanced masks. This type masks can be an alternative for works suffering from loud noise generated by traditional air-line masks.

Advantages, Disadvantages, Indications, Contraindications and Surgical Technique of Laryngeal Airway Mask

  • Anubhav, Jannu;Ashim, Shekar;Ramdas, Balakrishna;Sudarshan, H.;Veena, G.C.;Bhuvaneshwari, S.
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.4
    • /
    • pp.223-229
    • /
    • 2017
  • The beauty of the laryngeal mask is that it forms an air tight seal enclosing the larynx rather than plugging the pharynx, and avoid airway obstruction in the oropharynx. The goal of its development was to create an intermediate form of airway management face mask and endotracheal tube. Indication for its use includes any procedure that would normally involve the use of a face mask. The laryngeal mask airway was designed as a new concept in airway management and has been gaining a firm position in anesthetic practice. Despite wide spread use the definitive role of the laryngeal mask airway is yet to be established. In some situations, such as after failed tracheal intubation or in oral surgery its use is controversial. There are several unresolved issues, for example the effect of the laryngeal mask on regurgitation and whether or not cricoids pressure prevents placement of mask. We review the techniques of insertion, details of misplacement, and complications associated with use of the laryngeal mask. We then attempt to clarify the role of laryngeal mask in air way management during anesthesia, discussing the advantages and disadvantages as well as indications and contraindications of its use in oral and maxillofacial surgery.

Mask-wearing Characteristics an COVID-19 in Indoor and Outdoor Environments in Seoul in 2020 (2020년 코로나바이러스감염증-19 유행 상황에서 서울시 다중이용 시설 및 실외에서의 마스크 착용 행태)

  • Kang, Sohyun;Guak, Sooyoung;Bataa, Altangerel;Kim, Donghyun;Jung, Youngdeok;Shin, Jiyoon;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.750-756
    • /
    • 2020
  • Objectives: After coronavirus disease 2019 (COVID-19) was declared a pandemic, the South Korean government announced guidelines on wearing masks to prevent its spread. The guidelines have changed depending on the severity of the spread of COVID-19. This study aimed to identify mask-wearing behaviours to counter the spread of COVID-19 in indoor and outdoor environments. Methods: The type of mask worn and proper wearing were observed in cafés, supermarkets, underground shopping malls, and streets in Seoul. Behavioral assessment was repeated in August at social distancing levels 1 and 2, in October at social distancing level 1, and in November after the mask mandates. Results: In August, 22.1% of subjects in cafés, 90.8% in supermarkets, 91.8% in underground shopping malls, and 83.6% on outdoor streets wore masks properly. In October, the proportion of correct wearers increased in all locations. After masks became mandatory in November, about 97% of users of supermarkets, underground shopping malls, and streets wore masks properly. In cafés, the proportion of proper wearers was 61.5% with both social distancing level 2 in August and the mandate in November. The number of KF-certified mask wearers continued to increase from August to November. Conclusion: This study investigated mask-wearing behaviors to counter COVID-19 through observations in indoor and outdoor places in Seoul. Mask-wearing behavior was different depending on the place and the government guidelines in place. The results could be used for evaluation of the current guidelines for COVID-19.

Assessment of Masks Used by Healthcare Workers: Development and Validation of a Mask Qualitative Assessment Tool (MQAT)

  • Gharibi, Vahid;Cousins, Rosanna;Mokarami, Hamidreza;Jahangiri, Mehdi;Keshavarz, Mohammad A.;Shirmohammadi-Bahadoran, Mohammad M.
    • Safety and Health at Work
    • /
    • v.13 no.3
    • /
    • pp.364-371
    • /
    • 2022
  • Background: Respiratory masks can provide healthcare workers with protection from biological hazards when they have good performance. There is a direct relationship between the visual specifications of a mask and its efficacy; thus, the aim of this study was to develop tools for qualitative assessment of the performance of masks used by healthcare workers. Methods: A mixed-methods design was used to develop a qualitative assessment tool for medical face masks (MFM) and particle filtering half masks (PFHM). The development of domains and items was undertaken using observation and interviews, the opinions of an expert panel, and a review of texts and international standards. The second phase evaluated the psychometric properties of tools. Finally, the validated Mask Qualitative Assessment Tools (MQAT) were used to assess six samples from 10 brands of the two types of masks. Results: MQAT-MFM and MQAT-PHFM shared 42 items across seven domains: "cleanliness," "design," "marking, labeling and packaging," "mask layers," "mask strap," "materials and construction," and "nose clip." MQAT-MFM included one additional item. MQAT-PHFM included another nine items associated with an eighth "Practical Performance" domain, and the valve version had another additional "Exhalation Valve" domain and six items. The evaluation indicated 80% compliance for MFM and 71% compliance for PFHM. "Marking, labeling and packaging" and "Layers" were associated with the least compliance in both types of masks and should be checked carefully for defining mask quality. Conclusion: MQAT can be used for immediate screening and initial assessment of MFM and PHFM through appearance, simple tools, and visual inspection.

Analysis and Implications of Korean Health Authorities' Fulfillment on World Health Organization's Recommendations for Mask Use: Focused on COVID-19 (세계보건기구의 마스크 사용 지침에 대한 한국 보건당국의 이행 분석과 함의: 코로나 바이러스 감염병을 중심으로)

  • Kim, MyungHee
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.8
    • /
    • pp.77-86
    • /
    • 2020
  • The study aims to analyze the compliance and non-compliance of the Korean health authorities regarding WHO's mask use recommendations following the spread of Covid-19, and to suggest the limitations and implications of the recommendations in the prevention of epidemics by deriving the causes of non-compliance with the results of alternative options. To this end, documents related to masks at home and abroad are reviewed, and WHO's mask recommendations and the Korean health authorities' mask guidelines are targeted for analysis. The analysis results are as follows. First, Korea's health authorities have basically accepted and applied WHO's "limited mask user perspective" in two recommendations. Second, Korea's health authorities have implemented differently from WHO mask recommendations due to the lack of supply and demand of masks. Third, Korea's health authorities were able to succeed in the initial prevention of Corona 19 based on the stabilization of the mask supply. Fourth, in the WHO mask recommendations, mask user restriction resulted in partial errors as a recommendation. The implication derived from the analysis is that even international recommendations based on medical evidence need to be allowed to follow autonomous guidelines according to the country's quarantine situation and competence, rather than strict adherence to international rules, in the infectious disease pandemic situation.

A Study of The Purchasing Tendency of Health-care Masks Based on The User-centered Design Concept-centered on the Form and Color of the Mask (사용자 중심 디자인개념에 기초한 보건용 마스크의 구매 경향성에 관한 연구 - 마스크의 형태와 색상 중심으로)

  • Ma, Lin;Kim, Myung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.9
    • /
    • pp.143-154
    • /
    • 2020
  • Due to the widespread of COVID-19 pandemics, as the health care supplies. Thus the facial mask has been transformed from personal health product into social epidemic prevention product, and its design is more inclined to be User-centered design. First employed health facial mask which is sold in the market as the method subject, under the concept of " User-centered design", this article analyzes the design elements such as appearance and color of the facial mask. Second used the analysis approach of sample, character and positioning map, this article conducts the comparative analysis research of collected sample and data and find the relationship of User-centered design, purchase tendency and health care facial mask. When the users purchase the mask, through the research on the relationship between the choice of form or color of mask and design element of mask, it can compensate for the blank spot of design and has some references.

Filtration Efficiencies of Commercial Face Masks in Korea for Biological Aerosols (국내 출시 마스크의 바이오에어로졸 여과효율 평가)

  • Choi, Sueun;Choi, Doseon;Jang, Sung Jae;Park, SungJun;Yoon, Chungsik;Lee, Kiyoung;Ko, GwangPyo;Lee, Cheonghoon
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.2
    • /
    • pp.116-122
    • /
    • 2022
  • Background: The recent COVID-19 pandemic is one of the worst disease outbreaks of the 21th century. Due to a lack of reliable antiviral therapeutics, wearing face masks is recommended to prevent airborne infection originating from virus-contaminated bioaerosols. Objectives: The aim of this study was to evaluate the filtration efficiencies of face masks that are commercially available in South Korea for a biological aerosol of Staphylococcus aureus (S. aureus) and murine coronavirus, a well-known surrogate for human coronaviruses. Methods: We collected six different kinds of commercial masks: two Korea Filter (KF)94 (KF94-1, KF94-2) masks, one surgical (Surgical-1) mask, one anti-droplet (KF-AD-1) mask, and two dust (Dust-1, Dust-2) face masks. S. aureus (ATCC 6538), a well-performing test bacteria and murine coronavirus (ATCC VR-764) were prepared under a suitable culture condition. Then, a mask biological filtration tester was used to examine the microbial filtration efficiencies of masks. Test microorganisms were quantitatively measured via cultivation methods and microbial filtration efficiencies were calculated appropriately. Results: All face masks showed over 99.6% filtration efficiency for S. aureus or murine coronavirus. There were no significant differences among the bacterial filtration efficiencies of the face masks. KF94-1 (99.97±0.08%) and Dust-1 mask (99.97±0.07%) showed the highest (over 99.9%) filtration efficiency for murine coronavirus. KF94-1 or Dust-1 masks showed a significant virus filtration efficiency compared to Surgical-1 mask (p<0.05; Mann-Whitney U test). Conclusions: All the commercially available face masks used in this study can filter S. aureus or murine coronavirus in bioaerosols efficiently, regardless of the mask type. Therefore, our results suggest that wearing a certified face mask is a reliable means to prevent the transmission of infectious airborne diseases via biological aerosols.

Microbial Contamination according to the Numbers of Mask Worn in the Community

  • Eun Ju Lee;Heechul Park;Min-A Je;Songhee Jung;Gahee Myoung;Su Bin Jo;Hyun Min Hwang;Ryeong Si;Hyunwoo Jin;Kyung-Eun Lee;Jungho Kim
    • Biomedical Science Letters
    • /
    • v.28 no.4
    • /
    • pp.317-321
    • /
    • 2022
  • Due to COVID-19 pandemic, wearing face masks is obligatory to prevent respiratory virus transmissions in the community. However, there are few studies of the desirable number of wearing a face mask, and how to store them for reuse. Therefore, in this study, a survey was conducted among 208 healthy adults, and 27 kf-94 masks worn for 1, 2, and 3 days were collected. To estimate the risk of bacterial contamination, we analyzed the extent of bacterial contamination of the BHI medium and 16S rRNA gene sequencing. With an increase in the number of days of using the mask, the degree of bacterial contamination of the used mask gradually increased. As a result of 16S rRNA PCR performed for strain identification, Staphylococcus, known as a pathogenic bacterium, was identified the most. In conclusion, we found that wearing a cotton KF mask provides an optimal environment for microbes, which are related to the skin and respiratory system, to thrive. Therefore, it is also important to reduce the risk of bacterial infection of the face mask with appropriate sterilization methods.

Half-Mask Interface Prototype Design using Korean Face Anthropometric Data (한국인 안면부 인체 데이터를 이용한 마스크 계면 프로토타입 설계)

  • Song, Young-Woong;Yang, Won-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.87-92
    • /
    • 2010
  • The mask-face interface design should consider the face shape to improve the half mask respirator's fit ratio. This study tried to design the mask-face interface using recent Korean face data. By using the data of 1536 men's 3D face scanning (Size Korea data), head clay mock-up was made and mask-face interface line was extracted from this head mock-up. Using this interface line, the half-mask prototype was made. According to the quantitative fitting test, the proposed mask was found to be well fitted (average fit-ratio > 100). The proposed method had two advantages. 1) The method could use massive head-related anthropometric data like Size Korea data. 2) The qualitative fit test (observation) could be conducted very quickly by fitting the prototype to the head mock-up. However, this method also had several limitations. 1) The head clay mock-up could be different according to the mock-up maker. 2) The average values of the head-related anthropometric data were used to make the head mock-up. Small and large size head mock-ups should be made and tested.

Correlation of Fit Factors for Respirators and Anthropometric Dimension (호흡기보호구의 밀착계수와 안면구조의 관계)

  • Han, Don-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.3 s.62
    • /
    • pp.440-448
    • /
    • 1998
  • In many developed countries, for example, USA, respirator fit testing is required before entering specific work environment to ensure that the respirator worn satisfies a minimum of fit and that the user knows when the respirator fits properly. Unfortunately because we have not fit test regulation in Korea, a lot of workers wearing respirators may be potentially exposed to hazards. This study was conducted to evaluate the fitting performance for respirators and correlation fit factors with facial dimensions of wearers. 110 subjects (70 males, 40 females) were fit tested for three quarter masks, i.e., two domestic-made Mask 2, and Y and one foreign-made Mask T using PortaCount 8020. A facial dimension survey of the same subjects was conducted to develop a facial dimension grids fer correlation fit factors with facial dimension parameters. A facial dimension grid was developed on the basis of face length and lip length for quarter masks. The results obtained were as follows : 1 Fit factors of Mask T were much higher than those of Masks Z, and Y. 2. Males were fitted more properly than females. 3. Male in box 'f' of grid would be adequately fitted Mask Y and male in box 'b', 'e', 'f', 'h' of grid would be sufficiently fitted Mask T. Female in box 'h' of grid may have a good fitting performance for both Mask Y, and T. But subjects in all boxes of grid would be inadequately fitted Mask Z.

  • PDF