• Title/Summary/Keyword: Header shape

Search Result 21, Processing Time 0.026 seconds

Investigation of Flow Distribution Characteristics at the Channel Location according to the Header Shape of Welded Plate Heat Exchanger (용접식 판형열교환기 헤더형상에 따른 채널 위치별 유량 분배 특성 고찰)

  • Ham, Jeonggyun;Kim, Eui;An, Sungkook;Cho, Honghyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.3
    • /
    • pp.7-13
    • /
    • 2019
  • To improve the flow distribution at channel locations in the welded plate heat exchanger with "L"-type inflow, the flow visualization of Model 1 was carried out. Besides, the characteristics of flow distribution was investigated experimentally according to the header shape. The inlet flow rate for each channel location was increased at the side channels but decreased at the central channels. In the case of Model 2, which has a slant structure added to the basic header of Model 1, the unevenness of inlet flow increased by 23% from 0.019 to 0.023 as compared to Model 1. On the other hand, Model 3, which has a baffle structure added to Model 2, showed 0.064 unevenness in inlet flow, which was a 36% reduction one compared to Model 1. To improve the distribution at each channel in the welded plate heat exchanger with "L"-type flow, it is necessary to improve the header external shape for the guide of flow as well as the baffle structure for reduction of vortex flow.

A Study on the Basic Shape of an MF Evaporator (MF증발기 기초 형상 설계에 관한 연구)

  • Park, Yong-Seok;Seong, Hong-Seok;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.6
    • /
    • pp.39-44
    • /
    • 2019
  • The evaporator is a key driver of an air conditioning system's efficiency. In this study, we study methods of maximizing the efficiency of a Massey Ferguson (MF) evaporator by measuring how the cooling performance of different shapes vary with temperature. We varied the tube insertion depth as well as the shape of the evaporator's header and tube. When we compare header shapes of "D", "Ellipse", and "Quadrangle" types, we find that the elliptical header creates the smallest pressure loss and the highest temperature difference. Between tube shapes of "Rectangular", "Projection", and "Circular" types, the "Projection" type tube creates the most temperature difference. We also investigated the depth of tube insertion in the header and find that tube insertion of 5 - 10 mm is feasible; we selected the depths of 5, 7, and 10 mm since they corresponded to approximately 30%, 50%, and 70% of the total width of the header. The tube insertion test demonstrated that a tube insertion depth of 7 mm creates the least pressure loss and the highest temperature difference. In conclusion, the optimal evaporator design uses an "Ellipse" type header, "Projection" type tube, and a tube insertion depth between 30 and 50% of the header width.

Thermal and Flow Analysis inside the Header of a Parallel Flow Heat Exchanger (평행류 열교환기의 헤더내 열유동 해석)

  • 이관수;오석진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.802-809
    • /
    • 2000
  • This study numerically analyzes the thermal and flow characteristics inside the header in PFHE(parallel-flow heat exchanger) by employing a three-dimensional turbulence modeling. The following quantities are examined by varying the injection angle of the working fluid, the location of entrance and the shape of entrance: flow nonuniformity, heat transfer rate, and flow distribution in each passage. The result shows that the degree of significance among the parameters affecting the header part is in the order of the injection angle, the shape of entrance, and the location of entrance. The result also indicates that heat transfer rates compared to the reference model are increased by about 152% for the angle of injection of -$20^{\circ}C$, by about 127% for the shape of entrance with right and left long rectangular form, and by about 108% for the location of entrance located at the lowest Position.

  • PDF

A Study on the Use and Features of Bangyeon on the Seungtap (방연(方椽)이 표현된 승탑의 용례와 특징에 관한 연구)

  • Cho, Hyun-Jung;Kim, Wang-Jik
    • Journal of architectural history
    • /
    • v.26 no.2
    • /
    • pp.7-14
    • /
    • 2017
  • Rafter is a member for roof and plays a role in protecting shaft members under rafter such as pillar, beam and girder from natural environment and to fix by supporting finished materials of roof. It is common in the Korean architecture that rafter cross-section is paired with circular form and Buyeon cross-section is paired with the square shape. However, while there are not many, some architectures have rafter end header in the square shape. The aim of this study is to examine the square shape cases of rafter end header with special reference to stone structure. As a result, among stone structure related to Bangyeon, the majority case is seen at Palgakwondang type Seungtap. It was shown in the Seungtap of monk of Gusanseonmun school in the later Unified Silla to the early Goryeo period that succeeded Seodang Jijang.

Efficient Coding of Motion Vector and Mode Information for H.264/AVC (H.264/AVC에서 효율적인 움직임 벡터와 모드 정보의 압축)

  • Lee, Dong-Shik;Kim, Young-Mo
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.10
    • /
    • pp.1359-1365
    • /
    • 2008
  • The portion of header in H.264 gets higher than those of previous standards instead of its better compression efficiency. Therefore, this paper proposes a new technique to compress the header of H.264. Unifying a sentence elementary in H.264, H.264 does not consider the distribution of element which be encoded and uses existing Exp-Golomb method, but it is uneffective for variable length coding. Most of the header are block type(s) and motion vector difference(s), and there are redundancies in the header of H.264. The redundancies in the header of H.264 which are analyzed in this paper are three. There are frequently appearing symbols and non-frequently appearing symbols in block types. And when mode 8 is selected in macroblock, all of four sub-macroblock types are transferred. At last, same values come in motion vector difference, especially '0.' This paper proposes the algorithm using type code and quadtree, and with them presents the redundant information of header in H.264. The type code indicates shape of the macroblock and the quadtree does the tree structured motion compensation. Experimental results show that proposed algorithm achieves lower total number of encoded bits over JM12.4 up to 32.51% bit reduction.

  • PDF

A Study on Thermal Performance of Microchannel Waterblock for Cooling of CPU in Desktop (컴퓨터 CPU 냉각용 미세채널 워터블록의 열성능에 관한 연구)

  • Choi, Mi-Jin;Kwon, Oh-Kyung;Cha, Dong-An;Yun, Jae-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.264-269
    • /
    • 2007
  • The microchannel waterblock has a good capability in the cooling of electronic devices. The object of this paper is to study on thermal performance of microchannel water block for cooling of CPU in desktop. The effects of header shape, liquid flow rate, and inlet temperature on the thermal performances of microchannel waterblock are investigated experimentally. Three types of waterblock with different header shape are manufactured from the micro milling and brazing processing. The experiments are conducted using water, over a liquid flow rate ranging from 0.7 to 2.0 LPM and inlet temperature ranging from 20 to $35^{\circ}C$. Waterblocks are attached both horizontally and vertically on the test section to anticipate a performance of waterblock under the actual state in computer. The base temperature and thermal resistance decrease with increasing of liquid flow rate. It was found that the sample #1 was appropriate for the prototype of liquid cooling system.

  • PDF

Optimal Shape of a Parallel-Flow Heat Exchanger by Using a Response Surface Method (반응표면법을 이용한 평행류 열교환기의 형상 최적화)

  • Oh, Seok-Jin;Lee, Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.296-303
    • /
    • 2004
  • The heat and flow characteristics in a single-phase parallel-flow heat exchanger was examined numerically to obtain its optimal shape. A response surface method was introduced to approximately predict its performance with respect to the design parameters over the design domain. The inflow/outflow angle of the working fluid, the location of inlet/outlet, the protruding height of flat tube and the height of header were chosen as a design parameter The evaluation of the relative importance of the design parameters was performed based on a sensitivity analysis. An efficiency index was used as an evaluation characteristics value to simultaneously consider both the heat transfer and the pressure drop. The efficiency index of the optimum model, compared to that of the base model, was increased by 9.3%.

Numerical Analysis of Flow Rate Distribution of Diffusers with Various Shapes (다양한 디퓨저 형상의 유량 분배 특성에 관한 수치해석 연구)

  • Kim, Myoung Soo;Kim, Hoo Bae;Choi, Hyoung Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.789-795
    • /
    • 2014
  • In this study, the distribution characteristics of diffusers with various shapes that are installed in an open-type thermal storage system are numerically investigated. Four diffusers are designed to distribute a working fluid evenly through the holes on bifurcated pipes. Three-dimensional steady simulations of incompressible laminar flow are conducted using commercial software (ANSYS-FLUENT). The simulation results show that both the bidirectional header-type diffuser and the H-type diffuser distribute the working fluid evenly whereas both the unidirectional and the bidirectional diffusers distribute the working fluid unevenly. The results also show that the H-type diffuser requires a higher head of pump than the bidirectional header-type diffuser. Therefore, the bidirectional header-type diffuser is recommended for use because it enables even distribution of the working fluid and requires a low head of pump.

A study of heat transfer characteristics on the Multi-pass Heat exchanger with Minichannel (다분지 미니 채널 열교환기의 액단상 열전달 특성에 관한 연구)

  • Im, Yong-Bin;Lee, Seung-Hun;Kim, Jeung-Hoon;Kim, Jong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.357-362
    • /
    • 2006
  • This research focused on the multi-pass heat exchanger using the minichannel possessing the spring fin. An air-water was used as working fluid. The characteristics of liquid single phase heat transfer were verified. The compact heat exchanger (heat transfer area density : ${\beta}=2,146 m^2/m^3$), based on the shape of header(Top combining header), 63 minichannels ($D_i$ : 1.4 mm, L : 0.25 m) and the air side adopting the copper wire spring fin, was fabricated. The heat transfer area density of the air side was improved up to 161% when compared with the conventional fin-tube heat exchanger that adopts the heat transfer tube with the inner diameter of 5 mm. With regard to heat transfer performance, heat transfer rate per unit volume increased up to 142% when compared with the fin-tube heat exchanger adopting the heat transfer tube with the inner diameter of 5 mm.

  • PDF

A Study on the Use of Bangyeon on Wooden Architecture (목조건축의 방연(方椽) 용례 연구)

  • Cho, Hyun-Jun;Kim, Wang-Jik
    • Journal of architectural history
    • /
    • v.26 no.1
    • /
    • pp.17-30
    • /
    • 2017
  • The aim of this study is to examine the square shape cases of rafter end header with special reference to wooden architecture and Uigwe records. In Uigwe, the member Bangyeon is widely used in multiple Changung and Chansil, and it is the most used in various gates in the buildings. It is also found in Haenggak and Subokbang. In the surviving wooden architecture, Bangyeon is found in pavilion, colonnade and gate in Changdeokgung Palace, and it is often seen in palace architecture. It is rare in private sector, and it is shown in Sangju Yangjindang and Andong Songsojongtaek. A total of 48 cases in Uigwe, can found records of Bangyeon. According to the records, mainly Yeonggeon Uigwe and Salleung Uigwe, it can be found that gates, also Bangyeon was used.