• Title/Summary/Keyword: Head motion

Search Result 681, Processing Time 0.034 seconds

Development of a Program That Computes the Position of the Instantaneous Center of Rotation on the Basis of Experimental Data(I) (실험 데이터를 이용한 회전운동 순간 중심점 분석 프로그램 개발(I))

  • Park, Jin;Shin, Ki-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.779-791
    • /
    • 2009
  • The purpose of this study is to develop a program that computes the position of the instantaneous center of rotation while an object moves in a circular motion. For this study, a mathematical algorithm was developed and implemented on the experimental data. Data for pitching (40m carry) and putting (4m) strokes were obtained from a skilled female golfer. A computer program (Centering 1.0) calculated the experimental data and found the radius of the instantaneous center of rotation. When the data were taken broadly, the program produced an error distance of radius. When the data were divided gradually, the program produced a very close instantaneous center of rotation. On comparing pitching and putting strokes, putting was found to have a greater radius than pitching. The instantaneous centers of rotation of putting were not in the golfer's body rather, they were 3m away from the club head. The Centering 1.0 program can calculate the instantaneous center of rotation with at least three sets of experimental data.

The Physiological Responses and Subjective Sensation in the Subjects Wearing Dust-free Garment for Semiconductor Industrial Environments (방진복 착용에 따른 인체의 온열생리적 특성 및 주관적 감각)

  • 권오경;이창미
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.255-263
    • /
    • 1998
  • Dust-free garment prevents contamination which otherwise is caused by skin and clothes to protect from dust or dirt. Therefore, it requires high performance and should function as a working clothes. Clothes are a medium between human and thermal environmental system, and it is required to study human enviroment to ensure comfortableness of clothes and to satisfactorily go along with enviroment .This study investigates the physical and physiological features of dust-free garment used in the clean room at a semiconductor factory in oredr to scientifically clarify what the dust-free garmint is as well as to contribute to the design and development of high performance material and clothes. Three kinds of dust-free fabrics (DFG-I, DFG-II, DFG-III) which are being developed by a local company are used to manufacture dust-free garment. These dust-free garments are dressed and tested in such an enviroment as similar to semiconmemts with temperature at 23${\pm}$1$^{\circ}C$ and humidity at 50${\pm}$5%RH in order to investigate the thermo physiological and psychological features of human body. The results of this study are as follows. The results of this study are as follows. 1.The mean skin temperature was significantly different among the clothes, subjects and experimental time. Temperature tends to rise from the time of exercising load. Continuous motion coupled sealed clothes prevents heat transmittance, and temperature rises in the order of DFG-l, DFG-ll and DFG-lll as time course. 2.As for the skin temperature by local timperature is minimun on the head and torso and increares remarkably at the terminal part of human body. 3. As for the body mass loss was significantly higher in DFG-lll than DFG-l and DFG-ll. 4. Though there is no significant difference in the temperature within clothes among the kind of clothes temperature is 1$^{\circ}C$ higher in the back. Temperature within all the dust-free garments 29.7$^{\circ}C$ in the back and 31.3$^{\circ}C$ in the chest which belong to the comfort zone(31-33$^{\circ}C$). The relative humidity is 39.7%RH in the chest and 33.8%RH in the back which is slightly below the comfort zone(40-60%RH) 5. The thermal sensation belong to the comfort zone regardless of the kinds of clothes. The subjects feels a slight fatigue as times goes. As for the subjective sense of subjects the mean skin temperature as well as temperature and humidity within clothes show similar tendency. This means that they relate with each other.

  • PDF

Comparison on the Kinematic Variables of Racket Movement According to Velocity in Tennis Serve (테니스 서브 속도에 따른 라켓 움직임의 운동학적 변인 비교)

  • Lee, Dong-Jin;Oh, Cheong-Hwan;Jeong, Ik-Su;Park, Chan-Ho;Lee, Gun-Hee
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.337-345
    • /
    • 2009
  • The purpose of this study were to find out the differences in kinematic variables of racket movement by performing the tennis serve. Three top male tennis players participated in this study. Three synchronized high-speed cameras were used to record the service action of top players for Three dimensional video analysis. The results of this study showed that (1) the velocity of the tennis racket at impact is important to the generation of racket velocity to Y-axis. This result indicates that forward motion and upward movement of the racket; (2) with respect to racket angular velocity at impact, the fast angular momentum of X-axis is important to generate the velocity of the tennis ball. This result indicate upward movement of the racket with a strong flexor of wrist joint; (3) the velocity of the tennis ball was influenced by the change of angular linking the Z-axis to -X-axis. This result indicates that the high velocity of the tennis ball is obtained from having the racket unitedly moving to the direction of the bill's flight at the acceleration interval and acquiring the distance of acceleration with the racket head vertically to the ground at the back scratching.

A Pilot Study of the Korean Version of Speech Handicap Index (SHI) (한국어판 말장애지수(The Korean Version of Speech Handicap Index)에 대한 예비연구)

  • Park, Sung Shin;Choi, Seong Hee;Cha, Wonjae;Hong, Young Hye;Jeong, Nyun Gi;Sung, Myung-Whun;Hah, J. Hun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.24 no.1
    • /
    • pp.41-46
    • /
    • 2013
  • Background & Objectives : The Speech Handicap Index (SHI) is used to assess speech problem of head and neck cancer patients. The aim of this preliminary study was to evaluate the reliability and validity the Korean version SHI. Materials and Methods : Sixteen patients with oral cavity cancer and 26 normal control were participated in the study. Test-retest reliability of the Korean version of SHI was completed by 20 out of 42 subjects after 2weeks. Mann-Whitney U test was used to compare the Korean version of SHI scores between normal population and patients group. The relationship between the Korean version of SHI and diadochokinesis (DDK) was investigated using Spearman correlation coefficients. Results : The Korean version of SHI provided a high internal consistency (${\alpha}$=0.99) and test-retest reliability (Spearman rho 0.98). The mean SHI scores [total (T), speech (S), and psychosocial (P)] in normal population were 0.8 (T), 0.2 (S) and 0.4 (P), whereas those in patients group were 58.1 (T), 27.9 (S) and 27.0 (P) respectively. There were significant differences in total SHI score as well as in all of the sub-SHI scores between two groups. Moreover, significant correlation between the Korean version of SHI parameters (T, S, P) and sequential motion rate (SMR) were yielded in patients group. Conclusion : The Korean version of SHIwas reliable and valid. It can be useful as a supplementary clinical tool for diagnosing and measuring treatment efficacy of speech problems related to oral cavity cancer.

  • PDF

Medial Retracted Large Rotator Cuff Tears (내측으로 퇴축된 대범위 회전근 개 파열)

  • Ko, Sang-Hun;Cha, Jae-Ryong;Kim, Tae-Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.212-219
    • /
    • 2009
  • Medially retracted large-sized rotator cuff tears includes large-sized tears, massive tears and irreparable tears. Generally arthroscopic repair or open repair of rotator cuff tears is used in reparable tears. However, arthroscopic repair requires long period practice and endurance. In irreparable tears, arthroscopic debridement, partial repair, latissimus dorsi transfer and retrograde arthroplasty can be the option. Arthoscopic debridement gives temporal relief who experienced improvement in pain and increase in range of motion after subacromial local anesthetic injection. Also arthroscopic partial repair gives good results in irreparable cases, especially in suprascapular nerve traction neurapraxia. Tendon transfer can be used in mild to moderate muscle weakness in shoulder abduction for long term treatment. Pectoralis major transfer can be used in anterosupeior tears and latissimus dorsi transfer can be used in posterosuperior tears. Reverse shoulder prosthesis is used in extreamly weakened shoulder pseudoparalysis. The authors discussed the method of arthroscopic repair in irreparable tears. The debridement, partial repair, and tendon transfer could be used in medially retracted large-sized rotator cuff tears.

  • PDF

The effects of muscle activity of ambulance workers carrying a patient on a stretcher with or without helmets (구급대원의 헬멧 무게에 따른 들것 들고 내릴때 근활성도에 미치는 융합 요인분석)

  • Shin, Dong-Min;Cho, Byung-Jun;Kim, Gyoung-Young
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.1
    • /
    • pp.371-380
    • /
    • 2019
  • Electromygram was measured in three different cases; not wearing of a helmet, wearing of a 920g helmet, and wearing of a 1310g helmet, and it was revealed that there was a high level of muscle activities on the opposite side (sternocleidomastoid muscle) while the head and the neck were moving right and left and muscle activities of the curve and of the hyperextension were found to be not significant. Especially, the presence of a helmet seemed to cause a difference in a level of muscle activities on the deltoid and erector spine muscles while lifting or lowering with a weight placed on the deniz backboard. Therefore, it would be possible to assume that this newly developed smart helmet would not affect muscles around the necks of paramedics if they do not move their necks and heads right and left while lowering or lifting a patient using the deniz backboard. In addition, in case of the deltoid and erector spine muscles, it is shown that an increase in the degree of movement could lead to an increase in the level of muscle activities on the muscles controlling of the corresponding action, which are waist and back muscles. Despite it, it would be possible to prevent possible injuries and/or muscular and skeletal diseases around the lumbar by fully complying with a basic rule of straightening of the waist while making a power-lifting motion.

A Study on Movement Interface in Mobile Virtual Reality (모바일 가상현실에서의 이동 인터페이스에 관한 연구)

  • Hong, Seunghyun;Na, Giri;Cho, Yunsik;Kim, Jinmo
    • Journal of the Korea Computer Graphics Society
    • /
    • v.27 no.3
    • /
    • pp.55-63
    • /
    • 2021
  • This study proposes an interface for providing mobile interaction suitable for mobile virtual reality (VR) and analyzes it through comparative experiments. The proposed interface is premised on not using additional equipment except for the mobile head-mounted display(HMD) in consideration of accessibility and usability. And the interface that controls the movement interaction using the user's gaze is designed in two phases. The key is to minimize the occurrence of negative factors such as VR sickness that can be caused by straight line movement in virtual reality. To this end, two phases are designed: an interface composed of forward/backward buttons to move the gaze toward the ground, and an interface composed of left and right buttons on the front in consideration of the gaze change in real walking motion. An application that can compare and analyze movement interactions through the proposed interface is produced, and a survey experiment is conducted to analyze the user's satisfaction with the interface experience and the negative impact on the movement process. It was confirmed that the proposed movement interaction reduced negative effects such as VR sickness along with a satisfactory interface experience for users.

Human Skeleton Keypoints based Fall Detection using GRU (PoseNet과 GRU를 이용한 Skeleton Keypoints 기반 낙상 감지)

  • Kang, Yoon Kyu;Kang, Hee Yong;Weon, Dal Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.127-133
    • /
    • 2021
  • A recent study of people physically falling focused on analyzing the motions of the falls using a recurrent neural network (RNN) and a deep learning approach to get good results from detecting 2D human poses from a single color image. In this paper, we investigate a detection method for estimating the position of the head and shoulder keypoints and the acceleration of positional change using the skeletal keypoints information extracted using PoseNet from an image obtained with a low-cost 2D RGB camera, increasing the accuracy of judgments about the falls. In particular, we propose a fall detection method based on the characteristics of post-fall posture in the fall motion-analysis method. A public data set was used to extract human skeletal features, and as a result of an experiment to find a feature extraction method that can achieve high classification accuracy, the proposed method showed a 99.8% success rate in detecting falls more effectively than a conventional, primitive skeletal data-use method.

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF