• 제목/요약/키워드: Head loss & discharge

검색결과 35건 처리시간 0.028초

유체동압베어링을 사용하는 하드디스크 드라이브 스핀들 시스템에서 발생하는 정전기 방전에 관한 실험적 연구 (Experimental Study on the Electrostatic Discharge in the HDD Spindle System Using Fluid Dynamic Bearings)

  • 강민구;장건희
    • 한국소음진동공학회논문집
    • /
    • 제16권1호
    • /
    • pp.75-80
    • /
    • 2006
  • This paper introduces the mechanism of the ESD(electrostatic discharge) in the HDD spindle system using FDBs(fluid dynamic bearings). When a HDD(hard disk drive) spindle system is rotating, triboelectric charging occurs in the FDBs through the friction between the lubricant and the rotating shaft or between the lubricant and stationary sleeve. And this electrostatic charge is accumulated in the rotating parts of the HDD spindle system because they are insulated from the ground by the lubricant. This research shows experimentally that the behavior of electric charge and discharge in the FDB spindle system is the same as that of a capacitor. It also measures the electrostatic voltage difference between the rotating and stationary parts in the FDB spindle system due to the change of humidity, supporting load and motor speed. This research shows that the control of ESD is required in the HDD spindle system using FDBs, because the electrostatic charge accumulated in the FDB spindle system may cause the breakdown damage of the GMR head and data loss consequently.

수중펌프의 Leakage-free 자동탈착장치 개발 (Development of Leakage-free Automatic Discharge Connect in a Submersible Pump.)

  • 최영석;이경용;이창한;이종훈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.63-68
    • /
    • 2002
  • ADC(Automatic Discharge Connector) is commonly used for the easy maintenance of the submersible pumps. However, the small gap between the flange of the base plate and that of the pipe due to the head rise, the flow momentum change and the mis-installation makes leakage flow that may be a great loss to the pumping system. In this study, the performance degradation was predicted with the simple leakage flow model through the gap. The newly developed ADC was tested and the leakage performance was compared with the old one and also no-leakage piping system. The newly developed ADC reduced the leakage flow in a satisfactory way in comparison with the old model.

  • PDF

수중펌프의 Leakage-free 자동탈착장치 개발 (Development of Leakage-free Automatic Discharge Connector in a Submersible Pump.)

  • 최영석;이경용;이창한;이종훈
    • 한국유체기계학회 논문집
    • /
    • 제6권2호
    • /
    • pp.23-28
    • /
    • 2003
  • ADC (Automatic Discharge Connector) is commonly used for the easy maintenance of the submersible pumps. However, the small gap between the flange of the base plate and that of the pipe due to the head rise, the flow momentum change and the mis-installation make a leakage flow that may be a great loss to the pumping system. In this study, the performance degradation was predicted with the simple leakage flow model through the gap. The newly developed ADC was tested, and the leakage performance was compared with the old one and also no-leakage piping system. The newly developed ADC reduced the leakage flow in a satisfactory way in comparison with the old model.

신생아 청력장애의 선별검사와 의의 (Newborn heating screening)

  • 김리석
    • Clinical and Experimental Pediatrics
    • /
    • 제50권1호
    • /
    • pp.7-13
    • /
    • 2007
  • Hearing loss in newborns is the most frequently occurring birth defect. If hearing impaired children are not identified and managed early, it is difficult for many of them to acquire the fundamental language, social and cognitive skills that provide the foundation for later schooling and success in society. All newborns, both high and low risk, should be screened for hearing loss in the birth hospital prior discharge (Universal Newborn Heaing Screening, UNHS). Objective physiologic measures must be used to detect newborns and very young infants with hearing loss. Recent technological developments have produced screening methods and both evoked otoacoustic emission (EOAE) and auditory brainstem response (ABR) have been successfully implemented for UNHS. Audiologic evaluation should be carried out before 3 months of age and infants with confirmed hearing loss should receive intervention before 6 months of age. All infants who pass newborn hearing screening but who have risk indicators for other auditory disorders and/or speech and language delay receive ongoing audiologic surveillance and monitoring for communication development. Infants with sensorineural hearing loss are managed with hearing aids and receive auditory and speech-language rehabilitation therapies. Cochlear implants can be an outstanding option for certain children aged 12 months and older with severe to profound hearing loss who show limited benefit from conventional amplifications.

25.8kV GIS 부분방전 측정전용 UHF센서 개발 (UHF Sensor Development for Partial Discharge Exclusively for Measurement in 25.8kV GIS)

  • 최문규;차한주
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.1083-1088
    • /
    • 2016
  • 25.8kV GIS part generated by sensors to measure contact an inflow of noise depending on the extent of the measured discharge occurs often not easy. Partial discharge signal measurement sensor suitable for developing a more useful measurements at the scene to this, partial discharge waveform analysis developed a sensor, and to utilize forSensor on the development of the most important is VSWR decided to (voltage standing wave ratio) voltage standing-wave ratio less than 1.5 and decided less than at the full spectrum bands that are measured, this time Return loss, as measured value by absolute criteria 14.0 dB produced the sensor, designed to or more. UHF 1.5~0.5 GHz bandwidth spectrum to be measured in GIS. UHF bands were designed to be able to measure the best signal. Recently, 25.8kV GIS production company has been increasing variety of GIS were made open spacer in partial discharge in accordance with the not very easy to detect the signal. The sensor is designed height of four cm external spacer is attachment GIS in an influx of outside noise measurement, and be so manufactured as to facilitate the least we've done. Also, since partial discharge which occur can measure the frequency of the 170kV GIS external partial-discharge signals that occur at the scene of insulation applied to the spacer. Features, and also derived good results using global positioning. Also measured discharge point about sensors that are stable and the reliability of the development and local substation equipment failure occurring signal analysis through the discharge for the prevention of widely. There should be to believe that used.

스프링클러설비 설계의 수리계산 절차에 대한 연구 (A Study on Hydraulic Calculation Procedure of Fire Sprinkler System Design)

  • 정기신
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.24-32
    • /
    • 2018
  • 수리계산방식에 의한 설계는 전산프로그램을 사용하는 방식과 직접 설계자가 계산에 의하여 설계하는 방식이 있다. 전산프로그램을 사용하는 경우 필요한 조건을 입력하면 프로그램에 의해 마찰손실, 유량, 양정 등을 계산하여 주지만 기본적인 개념과 절차를 모르게 되면 계산값이 입력자마다 다를 수가 있어 절차상의 기준을 정하는 것이 필요하다. 설계자가 직접 계산하는 경우에도 동일하다. 따라서 설계면적 내에서 수리계산의 절차를 다음과 같이 제시하였다. 가지관에 설치되는 티의 등가길이는 방출구(Outlet)의 관경이 다를지라도 설치된 배관의 관경과 동일한 관경(Run)의 등가길이를 선택한다. 가지관 중간에 손실값이 큰 다른 헤드가 있더라도 말단에서부터 계산해온 압력이 더 크다면 말단헤드에서부터 계산해온 압력으로 헤드방출량을 계산한다.

왕복동식 공기압축기의 소음저감에 관한 공학적 대책 연구 (Noise Reduction of Reciprocating Type Air Compressors)

  • 이광기;박재석
    • 한국안전학회지
    • /
    • 제21권5호
    • /
    • pp.12-16
    • /
    • 2006
  • This paper deals with the noise evaluation and noise reduction of a reciprocating air-compressor. The reciprocating air-compressor is widely used in the small and medium sized industrial firms, many employees exposed and irritated by their noise in the workplace. Thus, appropriate noise control actions should be taken to prevent hearing loss due to the its noise exposure. Lead-wrapping techniques are employed to identify the contribution of principal noise sources which are generally known to be motor, belts, suction valves, discharge valves, moving parts, and flow-induced noise caused by edges or discontinuities along the flow path including expansions, contractions, junctions and bends. As a result, the main noise sources of the air-compressor are categorized by the suction and discharge noise, valve noise, and compressed air tank noise. Based on the investigations, mufflers are designed to reduce both the suction and discharge noise and the compressed-air tank noise. Instead of the conventional valve plate, polyethylene resin is used the reduction of valve impact noise. In addition, attempts are made to reduce the valve noise propagation to the cylinder head and the compressor tank by using the insulation casings. As a result of the countermeasure plans, a noise reduction up to 10dB(A) could be achieved for the air-compressor.

화재현장에서 사용하는 소방호스의 마찰손실 감소 방안에 관한 연구 (A Study on the Friction Loss Reduction in Fire Hoses Used at a Fire Scene)

  • 민세홍;권용준
    • 한국화재소방학회논문지
    • /
    • 제27권3호
    • /
    • pp.52-59
    • /
    • 2013
  • 본 연구에서는 화재현장에서 사용하는 소방호스에 대하여 사용압력과 방수량 변화에 따른 마찰손실을 실측하였다. 소방호스의 종류, 수량, 사용압력 등 소방호스의 사용 실태를 분석하여 그 결과를 토대로 실측한 결과 화재현장에서 소방공무원이 사용하는 조건에서 소방호스의 마찰손실은 무려 56.8%까지 측정되었다. 옥내 외 소화전설비에서 펌프양정 계산시 사용하는 소방호스의 등가 길이와도 많은 차이가 난다. 관련규정조차 마찰손실에 대한 제한 규정이 없고, 소방호스를 생산하는 업체에서도 마찰손실을 측정한 자료가 없으며, 화재현장에서는 마찰손실을 고려하지 않고 소방호스를 전개함으로써 호스의 사용량이 많아지고 소방펌프차에서 고압으로 방수하게 되는 원인이 되므로 본 연구를 통하여 소방호스 마찰손실에 대한 등가길이 기준을 정립하고 화재현장에서 소방호스의 마찰손실을 고려한 전개 방법을 제안하고자 한다.

조력발전용 수문 형상에 따른 통수성능에 관한 실험적 연구 - I. 수리모형실험 (Experimental Investigation of Water Discharge Capability According to Shape of Sluice for Tidal Power Generation - I. Physical Experiment)

  • 이달수;오상호;이진학;박우선;조휴상;김덕구
    • 한국해안·해양공학회논문집
    • /
    • 제20권1호
    • /
    • pp.73-80
    • /
    • 2008
  • 이 연구에서는 조력발전소 건설의 경제성에 큰 영향을 미치는 수문(sluice)형상의 설계기술을 향상시키기 위해서 개수로 시스템에서 수리모형실험을 수행하였다. 수문 형상을 결정짓는 주요한 설계 파라미터의 변화가 수문의 통수성능에 미치는 영향이 예측 가능하게 되기 위해서는 기존의 조력발전소 타당성조사 및 설계사업 등에서의 수리모형실험 방법과 차별화 되는 정밀한 실험을 수행해야 할 필요성이 있었다. 이를 위해서 유량공급시설 및 정류수조 내에 다양한 정류장치를 그 형상 및 배치 방법을 다르게 설치하여 관측수로 내 흐름이 최대한 안정화되도록 실험시설을 구성하였다. 그리고 유량 및 수위 계측 과정에서 개입되는 계측 오차를 최소화하기 위한 실험이 이루어질 수 있도록 계측장비의 종류 및 수위 계측위치를 결정하였다. 또한, 개수로 내 흐름에서 불가피하게 발생하는 바닥 및 양측면 마찰에 의한 수두 손실효과를 고려하는 수두차 평가 방법도 제시하였다.

Mastoid osteoma: A rare incidental finding in an orthodontic patient

  • Borissova, Ioanna B.;Venturin, Jaqueline S.;Claro-Woodruff, Wanda I.;Shintaku, Werner H.
    • Imaging Science in Dentistry
    • /
    • 제50권4호
    • /
    • pp.347-351
    • /
    • 2020
  • Mastoid osteomas of the temporal bone are rare, benign, and usually asymptomatic tumors. However, depending on their size and extension, mastoid osteomas may cause facial palsy, a sensation of ear fullness, pressure-related pain, hearing loss, recurrent external ear infections, and chronic discharge. The etiology of mastoid osteomas is still unknown, but congenital, infectious, and traumatic factors have been proposed. Surgical treatment may be performed with minimal postoperative morbidity. In this article, the authors report a case of a 48-year-old woman seeking orthodontic treatment with an unusual retroauricular protruding mass, including the diagnostic process and differential diagnosis. This case supports the essential role of cone-beam computed tomography to analyze and identify the lesion as a mastoid osteoma.