• 제목/요약/키워드: Head detection

검색결과 475건 처리시간 0.025초

경증 두부외상 환자에서 MR FLAIR 영상의 임상적 유용성 (Clinical Usefulness of MR FLAIR Image in Mild Head Injuries)

  • 김세윤;황금;김헌주;이명섭
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권10호
    • /
    • pp.1182-1186
    • /
    • 2001
  • Objectives : MR fluid-attenuated inversion recovery(FLAIR) image uses paired long inversion time and relaxation time that nulls the signal from CSF. With nulling of the CSF long echo time readout could be used to increase T2-weighting, hence improving the conspicuousness of most tissue lesions without the deleterious effects of CSF artifact seen on T2 weighted sequence. We examed the usefulness of FALIR image in the diagnosis of mild head injury. Methods : A total of 38 patients with mild head injury were examined by FLAIR image. We compared those images with CT scan and T1, T2-weighted images. Careful observation of MR images were done by two well-trained neuroradiologists. Each image was compared for conspicuousness and detectability of traumatic lesions might have shown abnormal signal intensities. The Wilcoxon signed ranks test was used for statistical evaluation. Results : The FLAIR image was significantly more sensitive than those of other images(p<0.001). T2 FFE(Fast Field Echo) image was more useful for detection of small petechial hemorrhages. Conclusion : FLAIR image is considered to be more sensitive than those of conventional MR images in the evaluation of mild head injuries.

  • PDF

응시 위치 추적 기술을 이용한 인터페이스 시스템 개발 (Computer Interface Using Head-Gaze Tracking)

  • 이정준;박강령;김재희
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.516-519
    • /
    • 1999
  • Gaze detection is to find out the position on a monitor screen where a user is looking at, using the image processing and computer vision technology, We developed a computer interface system using the gaze detection technology, This system enables a user to control the computer system without using their hands. So this system will help the handicapped to use a computer and is also useful for the man whose hands are busy doing another job, especially in tasks in factory. For the practical use, command signal like mouse clicking is necessary and we used eye winking to give this command signal to the system.

  • PDF

A Lightweight Detection Mechanism against Sybil Attack in Wireless Sensor Network

  • Shi, Wei;Liu, Sanyang;Zhang, Zhaohui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권9호
    • /
    • pp.3738-3750
    • /
    • 2015
  • Sybil attack is a special kind of attack which is difficult to be detected in Wireless Sensor Network (WSN). So a lightweight detection mechanism based on LEACH-RSSI-ID (LRD) is proposed in this paper. Due to the characteristic of Low-Energy Adaptive Clustering Hierarchy (LEACH) protocol, none of nodes can be the cluster head forever.

Ad Hoc Network에서 블랙 홀 노드 탐지 향상 기법에 관한 연구 (A Study on Detection Improvement Technique of Black Hole Node in Ad Hoc Network)

  • 양환석;유승재
    • 융합보안논문지
    • /
    • 제13권6호
    • /
    • pp.11-16
    • /
    • 2013
  • 이동 노드는 임의로 이동을 하며, 라우터와 호스트 기능을 동시에 수행해야 한다. 노드들의 이러한 특성은 다양한 공격의 잠재적 위협 요소가 되고 있다. 특히 그중에서도 악의적인 노드가 패킷 손실을 유발시키는 블랙 홀 공격은 가장 중요한 문제 중에 하나이다. 본 논문에서는 블랙 홀 공격의 효율적인 탐지를 위하여 모든 노드에서 감시 테이블을 이용한 분산적 탐지와 클러스터를 기반으로 한 협업 탐지 기법을 제안하였다. 제안하는 기법에서는 공격 탐지의 정확도를 향상시키기 위하여 4단계의 과정으로 이루어진 로컬 탐지와 협업 탐지 과정으로 나누어 수행한다. 협업 탐지를 위해 클러스터 헤드는 블랙 홀 리스트를 이용하였다. Ns-2 시뮬레이터를 이용하여 제안한 기법의 성능을 평가하였으며, 실험결과에서 제안한 기법의 우수한 성능을 확인할 수 있었다.

원자로헤드 관통관 결함의 검출 정확성 연구 (A Study I on the Sizing Accuracy of the Characterized Defects of the Reactor Vessel Head Penetrations)

  • 정태훈;김한종
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.216-227
    • /
    • 2005
  • The head penetrations for control rod drive mechanism and instrumentation systems are installed at the reactor pressure vessel head of PWRs. Primary coolant water and the operating conditions of PWR plants can cause cracking of these nickel-based alloy through a process called primary water stress corrosion cracking (PWSCC). Inspection of the head penetrations to ensure the integrity of the head penetrations has been interested since reactor coolant leakages were found at U. S. reactors in 2000 and 2001. The complex geometry of the head penetrations and the very low echo amplitude from the fine, multiple flaws due to the nature of the see made it difficult to detect and size the flaws using conventional pulse-echo UT methods. Time-of-flight-diffraction technique, which utilizes the time difference between the flaw tips while pulse-echo does the flaw response amplitude from the flaw, has been selected for this inspection for it's best performance of the detection and sizing of the head penetration see flaws. This study defines the limits of the detectable and accurately sizable minimum flaw size which can be detected by the General TOFD and the Delta TOFD techniques for circumferentially and axially oriented flaws respectively. These results assures the reliability of the inspection techniques to detect and accurately size for various kind of flaws, and will also be utilized for the future development and qualifications of the TOFD techniques to enhance the detecting sensitivity and sizing accuracy of the flaws of the reactor head penetrations in nuclear power plants.

  • PDF

Femto Slider Head/Disk Interaction Detection by Acoustic Emission and Natural Frequency Analysis

  • 황평
    • KSTLE International Journal
    • /
    • 제6권1호
    • /
    • pp.17-20
    • /
    • 2005
  • The object of the present work is the natural lre%uency analysis of femto slider, HeaHdisk interaction during starustop and constant speed were detected by using the acoustic emission (AE) test system. The frequency spectrum analysis wasperformed using the AE signal obtained during the head/disk interaction. The FFT (Fast Fourier Transform) analysis of the AEsignals is used to understand the interaction between the AE signal and the state of contact. Natural frequency analysis wasperformed using the ANSYS program. The results indicate acceptable accordance of finite element calculation results with theexperimental results.

이하선수술시 안면신경의 위치에 따른 신경 보존 술식의 개선방법 (Rolling Method to Preserve Facial Nerve in Parotidectomy)

  • 유영삼
    • 대한두경부종양학회지
    • /
    • 제26권1호
    • /
    • pp.19-23
    • /
    • 2010
  • Objectives : In parotidectomy, facial nerve dissection technique had been evolved for its safety. Surgical landmarks are important and good guides to facial nerve detection. Conventional exposure and release of the nerve requires hemostat for elevation of parotid tissue from nerve and #11 blade for cutting the parotid away from the nerve. Material and Methods : The rolling the parotid tissue over the nerve after dissecting with Metzembaum scissors instead of knife, lessen pulling trauma and nerve cutting by knife. Eleven superficial parotidectomies since June 2009 were done with rolling technique and preliminary report is presented. Results : Total 11 parotidectomies were done using proposed technique with tolerable complications(temporary facial dysfunction in 4 cases). Conclusion : Rolling method using metzembaum scissors could be applied to parotid operation.

Evaluation of Head and Neck Cancer Awareness and Screening Status in Jeddah, Saudi Arabia

  • Alhazzazi, Turki Y
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권3호
    • /
    • pp.1135-1139
    • /
    • 2016
  • Background: Head and neck cancer (HNC) is one of the deadliest cancers worldwide. Early detection is a key determinant of HNC prognosis. Hence, raising awareness of this disease may improve survival rates. The present study evaluated the level of awareness and screening status for HNC in the general population of Jeddah, Saudi Arabia. Materials and Methods: An e-questionnaire was distributed during our HNC awareness campaign at the Red Sea Mall in Jeddah. The questions assessed HNC knowledge and screening status among participants. Results: Of the 112 respondents, 68% indicated that they had no knowledge of HNC. Social media was the major source of information (39%) for respondents. The majority (40%) believed that it was the joint responsibility of dentists, dental hygienists, and general physicians to screen for HNC; 82% had never been screened. Conclusions: Knowledge and awareness of HNC must be increased in the general population and among dental health professionals.

차세대 열 보조 자지기록용 마이크로 레이저 모듈 설계 및 제작 (Design and Fabrication of Micro Laser Module for Heat Assisted Magnetic Recording)

  • 이수찬;최용복;김영주;김동식
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.68-69
    • /
    • 2009
  • Heat Assisted Magnetic Recording (HAMR) is one of the most promising candidates for high density magnetic storages over 1 Tb/$in^2$ areal density. Since the precise light delivery to the head is a key factor to realize HAMR application, it is required to establish the light delivery using micro laser module and micro actuator. For the careful control of micro actuator, a laser module was designed including laser diode, optical fiber, collimating lens, and fabricated V-groove substrate. In addition, the basic aligning method between the laser module and HAMR head was studied by the detection of current change in photo diode due to the amount of reflected light from the head.

  • PDF

TOFD Technique을 이용한 원자로헤드 관통관 용접부 비파괴검사 (Reactor vessel head penetration J-groove welds inspection by TOFD technique)

  • 김왕배;이영호;문용식;김창수
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 춘계학술발표대회 개요집
    • /
    • pp.185-187
    • /
    • 2005
  • The reactor pressure vessel head of PWR has penetrations for control rod drive mechanism and instrumentation systems. The Primary coolant water and operating temperature can cause the stress-corrosion cracking of these nickel-based alloy penetrations. It is difficult to detect and size flaws such as SCC in the reactor head penetrations using conventional W methods because of complex geometry, Therefore, the utilities are using the TOFD technique for the detection and sizing of the flaw. This study shows the correlation between the ultrasonic wave direction and the orientation of the flaw and the range of flaw depth which can be detected by the TOFD techniques.

  • PDF