• Title/Summary/Keyword: Head coil

Search Result 124, Processing Time 0.031 seconds

Design of pillow type contactless recharging device for totally implantable middle ear systems (완전 이식형 인공중이를 위한 베개형 비접촉 충전장치의 설계)

  • Lim, Hyung-Gyu;Kim, Jong-Min;Kim, Min-Kyu;Yoon, Young-Ho;Park, Il-Yong;Song, Byung-Seop;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.78-84
    • /
    • 2005
  • A contactless recharging device for totally implantable middle ear systems has been designed as a pillow type that the user can recharge the implanted battery with taking a rest. The proposed device uses the electromagnetic coupling between the transmitting coil and the receiving coil. To supply sufficient power for the implanted circuits, each coil uses LC resonance and the implanted device uses voltage doubler. A power MOSFET is used for switching the DC voltage of LC parallel circuit and the switching frequency demands on a programmable frequency generator which is controlled by microcontroller. In order to improve the electromagnetic coupling efficiency at specific positions of coil which may vary with the displacement of head, the optimal location of receiving coil was studied, and the 5 transmitting coils in a pillow for recharging the implant module was designed. From such a recharging experiment, it was found that the proposed device could provide the sufficient operating voltage within the distance of 4 cm between pillow and the implanted device.

Construction of magnetic Resonance Imaging Probe for Internal Imaging Using Anti-Solenoid Coil (역-솔레노이드 코일을 이용한 내부 영상용 핵자기공명 영상 탐침의 제작)

  • Lee, D.H.;Ko, R.K.
    • The Journal of Natural Sciences
    • /
    • v.8 no.1
    • /
    • pp.27-32
    • /
    • 1995
  • Magnetic Resonance Imaging anti-solenoid probes have been constructed for the internal imaging. Signal-to-noise ratios of the images acquired by the anti-solenoid probes were compared with those obtained by commercial probes such as a head coil and a body coil. In terms of the internal imaging, the anti-solenoid probes, constructed in the present study, was performed better than the conventional commercial probes. Also, RF(radio-frequency)-field maps produced by the anti-solenoid probes have been simulated using computers. The possibility of human internal imaging using the anti-solenoid probes has been discussed as well.

  • PDF

Development of TEM Coil for Animal Experiments at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.78-78
    • /
    • 2002
  • Purpose: The purpose of this study is to describe a distributed circuit approach to high frequency volume coil design illustrated with specific coils built accordingly and results obtained from animal studies at 3.0 tesla. Method: All experiments were conducted on 3T MRI system (Medinus Co., Ltd. Korea). The tuned TEM resonator measures 15cm outer diameter. by 10cm inside diameter by 30cm in length. The inside diameter and length were determined by animals body or head size (eg. rats or small dogs, etc.) while the outer diameter was chosen for compactness with some sacrifice of the optimal coil Q predicted for a larger cavity. A spin echo sequence with a TR/TE/flip angle=500/12.4ms/$75^{\circ}$was used to check image qualities with phantom. The breed of rat which used for animal images was Sprague-dawley(SD) and was anesthetic using ketamin hydrochloride 75mg/kg.

  • PDF

Advances in Fast Vessel-Wall Magnetic Resonance Imaging Using High-Density Coil Arrays

  • Yin, Xuetong;Li, Nan;Jia, Sen;Zhang, Xiaoliang;Li, Ye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.229-251
    • /
    • 2021
  • Arteriosclerosis is the leading cause of stroke, with a fatality rate surpassing that of ischemic heart disease. High-resolution vessel wall magnetic resonance imaging is generally recognized as a non-invasive and panoramic method for the evaluation of arterial plaque; however, this method requires improved signal-to-noise ratio and scanning speed. Recent advances in high-density head and neck coil arrays are characterized by broad coverage, multiple channels, and closefitting designs. This review analyzes fast magnetic resonance imaging from the perspective of accelerated algorithms for vessel wall imaging and demonstrates the need for effective algorithms for signal acquisition using advanced radiofrequency system. We summarize different phased-array structures under various experimental objectives and equipment conditions, introduce current research results, and propose prospective research studies in the future.

A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System (실별제어 온수분배기의 유량분배 특성)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.

Membrane interaction of the coiled-coil motif of HIV gp41 and its implication in the membrane fusion process

  • Jin, Bong-Suk;Yu, Yeon-Gyu
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 2003.06a
    • /
    • pp.58-58
    • /
    • 2003
  • The envelope glycoprotein of HIV, gp41, mediates the membrane fusion with human cells. The extracellular domain of gp41 has two helical regions. The N-terminus helical region (N-helix) forms trimeric coiled coil, interacts with the C-terminus helical region (C-helix) of gp41 to form a stable helical bundle structure. In this study, we have shown that the N-helix of gp41 has membrane interacting and disrupting abilities. It was localized into the interface of the lipidic phase and head group of the membrane. In contrast, the N-helix region with membrane fusion defective mutations could not bind to membrane. In addition, the N-helix bound on the membrane was released from the membrane by the C-helix, and the complex of the N- and C-helix did not interact with membrane. These results suggested that the membrane binding ability of the N-helix is necessary for the fusion activity of gp41, and such property is possibly controlled by the C-helm.

  • PDF

Improvement of a 4-Channel Spiral-Loop RF Coil Array for TMJ MR Imaging at 7T (7T 악관절 MRI를 위한 4 채널 스파이럴 RF 코일의 성능개선)

  • Kim, Kyoung-Nam;Kim, Young-Bo;Cho, Zang-Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.103-114
    • /
    • 2012
  • Purpose : In an attempt to further improve the radiofrequency (RF) magnetic ($B_1$) field strength in temporomandibular joint (TMJ) imaging, a 4-channel spiral-loop coil array with RF circuitry was designed and compared with a 4-channel single-loop coil array in terms of $B_1$ field, RF transmit (${B_1}^+$), signal-to-noise ratio (SNR), and applicability to TMJ imaging in 7T MRI. Materials and Methods: The single- and 4-channel spiral-loop coil arrays were constructed based on the electromagnetic (EM) simulation for the investigation of $B_1$ field. To evaluate the computer simulation results, the $B_1$ field and ${B_1}^+$ maps were measured in 7T. Results: In the EM simulation result and MRI study at 7T, the 4-channel spiral-loop coil array found a superior $B_1$ performance and a higher ${B_1}^+$ profile inside the human head as well as a slightly better SNR than the 4-channel single-loop coil array. Conclusion: Although $B_1$ fields are produced under the influence of the dielectric properties of the subject rather than the coil configuration alone at 7T, each RF coil exhibited not only special but also specific characteristics that could make it suited for specific application such as TMJ imaging.

A study on Evaluating Validity of SNR Calculation Using a Conventional Two Region Method in MR Images Applied a Multichannel Coil and Parallel Imaging Technique (다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점)

  • Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Kwon, Kyung-Tae;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.403-410
    • /
    • 2015
  • The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.