• Title/Summary/Keyword: Head and neck.

Search Result 4,532, Processing Time 0.034 seconds

'Hwawang': A Good Quality and Early-Maturing Rice Variety Adaptable for Rice-Cash Crop Rotation System (소득작물 후작용 고품질 조생 벼품종 '화왕')

  • Lee, Jong-Hee;Lee, Ji-Yoon;Yeo, Un-Sang;Song, You-Chun;Park, Dong-Soo;Hwang, Un-Hwa;Park, Soo-Gwan;Park, No-Bong;Kim, Sang-Yeol;Oh, Seong-Hwan;Han, Sang-Ik;Nam, Min-Hee;Lee, Jong-Gi;Cho, Jun-Hyeon
    • Korean Journal of Breeding Science
    • /
    • v.50 no.4
    • /
    • pp.534-539
    • /
    • 2018
  • 'Hwawang' is an early maturing and short statured rice cultivar adaptable to the rice-cash crop rotation system that was developed by the rice breeding team of the Department of Southern Crop, National Institute of Crop Science (NICS), Rural Development Administration (RDA), Korea, in 2012. This cultivar was derived from the cross of YR25867 (Hitomebore//YR21247-B-B-B-49-1/Sasanishiki BL4) and YR25866 (Akidagomachi//YR21247-B-B-B-49-1/Sasanishiki BL4) during the 2005/2006 winter season and was fixed as a homozygous line by a doubled haploid breeding system. In the replicated yield trial in 2009, a promising line (YR26253Acp26-1) showed a good phenotype and high yield potential, and so it was selected and designated as 'Milyang256'. The local adaptability test of 'Milyang256' was carried out at three locations from 2010 to 2012. It was named 'Hwawang' and had a high head rice ratio and good eating quality. The culm length of 'Hwawang' averaged 62 cm during the yield trials and was 10 cm shorter than that of 'Keumo'. The number of spikelets per panicle of 'Hwawang' was significantly lower than that of 'Keumo', but the number of tillers per hill was higher. This variety showed resistance to bacterial blight disease but was moderately susceptible to both leaf and neck blast. The milled rice yield of 'Hwawang' was 452 kg/10 a at the late transplanting stage of the local adaptability test. Thus, 'Hwawang' is well adapted to the rice-cash crop rotation system in the southern plain area. (Registration No. 5106)

Immunohistochemical and Immunogold Electron Microscopic Studies on Effects of Cis-platin on the Ciliogenesis of Rat Oviducts (Cis-Platin이 흰쥐 난관의 섬모형성에 미치는 영향에 대한 면역조직학적 및 면역도금법에 의한 전자현미경적 연구)

  • Kim, Jin-Kook;Kim, Won-Kyu;Paik, Doo-Jin;Chung, Ho-Sam
    • Applied Microscopy
    • /
    • v.30 no.1
    • /
    • pp.45-59
    • /
    • 2000
  • Cis-platin is a widely used anticancer drug against certain solid tumors such as malignant ovarian tumor, malignant carcinoma of head and neck, bladder cancer and cervical cancer of uterus, and its major mechanism of action is inhibition of DNA synthesis of the tumor cell. To investigate the inhibitory effects of cis-platin on the ciliogensis of the ciliated cells in the mucosa of oviduct, the author pursued the alterations of $\alpha-tubulin$, which is the main constituent of the microtubles in cilia, after cis-platin treatment. To eliminate the possible variations due to ovarian cycle, female Spargue-Dawley rats ($150\sim200gm$ in B.W.) were pretreated with estradiol benzoate (20 mg/kg, once a day, for 4 consecutive days). Animals were administrated with cis-platin (6 mg/kg, i.p.) and sacrificed at 1day, 3days, 5days and 7days after treatment, respectively. Immunohistochemistry for $\alpha-tubulin$ using mouse anti-rat $\alpha-tubulin$ monoclonal antibody as primary antibody was done. Immunogold electronmicroscopy for intracellular distributions of $\alpha-tubulin$ was also performed with same primary antibody and Goat anti- mouse IgM which is preconjugated with gold particles of 15 nm as secondary antibody. The results obtained were as follows; 1. Strong immunoreactivity of $\alpha-tubulin$ was observed in ciliated cells of oviducts at 1, 3 and 5 days after estradiol pretreatment. 2. Weak immunoreactivity of $\alpha-tubulin$ was observed in ciliated cells of oviducts at 1 and 3 days after cis-platin treatment but it was recovered to strong immunoreactivity in 5 days 3. In immunogold electronmicroscopy, density of gold particles for $\alpha-tubulin$ reactions was decreased in apical cytoplasm, but few changes were observed in basal body or cilia at 1 and 3 days after cis-platin treatment. From these above results, it is indicated that synthesis of $\alpha-tubulin$ in ciliated cells of rat oviduct is inhibited by cis-platin treatment.

  • PDF

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

Injuries of the Elite Taekwondo Players in the International Tournament Performance - Analysis of the 2011 Gyeongju World Taekwondo Championship - (엘리트 태권도 선수의 국제 대회 경기 중의 손상 - 2011 경주 세계 태권도 선수권 대회의 분석 -)

  • Kim, Jong Pil;Chung, Phil Hyun;Kang, Suk;Kim, Young Sung;Lee, Ho Min;Choi, Young Hwa
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.86-93
    • /
    • 2011
  • Purpose: The purpose of this study was to analyze the characteristics of the injuries of the national elite Taekwondo players with the best performance in the international championship competition. Materials and Methods: Fifty-two athletes who got the injury in the 2011 Gyeongju World Taekwondo Championship competition were included in this sturdy. 950 members of national team of 146 countries participated in this game, 1,063 matches were performed. We analyzed the characteristics of the injuries such as injury rate by gender, age, weight class, injured region and injury type. Results: Fifty-two athletes of 950 athletes in 1,063 matches got injured and injury rate was 5.47 per 100 participants and 24.47/1,000 athlete-exposures. Injury rate of female athletes was higher than mail, but there was no significant statistical difference (p=0.512). Injury rate of over 30 years old was 17.39 per 100 participants, and injury rate of over 87 kg in male weight class and 68 to 73kg in female weight class were highest than other groups, but there was no significant statistical difference (p=0.838). Overall injury rate of the lower extremity was 13.17/1,000 A-E, higher than upper extremity or head and neck or trunk, but injury rate of the hand was 5.17/1,000 A-E, highest as a specific injured region, followed by the knee, 4.70/1,000 A-E (p=0.714). Injury rate of the sprain was 10.81/1,000 A-E, highest as an injury type, the second most common injury type was the fracture, 5.40/1,000 A-E in men, and was the contusion, 9.63/1,000 A-E in women (p=0.033). As one of the most serious injury, 4 of 8 fractures were occurred in hand. Conclusion: Overall injury rate of the elite Taekwondo players in 2011 Gyeongju World Taekwondo Championship was 5.47 per 100 participants and 24.46 per 1,000 athlete exposures. Although the most common type of injury was the sprain of the knee and ankle, the fractures were more commonly occurred in hand.

  • PDF

Improvement of the Dose Calculation Accuracy Using MVCBCT Image Processing (Megavoltage Cone-Beam CT 영상의 변환을 이용한 선량 계산의 정확성 향상)

  • Kim, Min-Joo;Cho, Woong;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.62-69
    • /
    • 2012
  • The dose re-calculation process using Megavoltage cone-beam CT images is inevitable process to perform the Adaptive Radiation Therapy (ART). The purpose of this study is to improve dose re-calculation accuracy using MVCBCT images by applying intensity calibration method and three dimensional rigid body transform and filtering process. The three dimensional rigid body transform and Gaussian smoothing filtering process to MVCBCT Rando phantom images was applied to reduce image orientation error and the noise of the MVCBCT images. Then, to obtain the predefined modification level for intensity calibration, the cheese phantom images from kilo-voltage CT (kV CT), MVCBCT was acquired. From these cheese phantom images, the calibration table for MVCBCT images was defined from the relationship between Hounsfield Units (HUs) of kV CT and MVCBCT images at the same electron density plugs. The intensity of MVCBCT images from Rando phantom was calibrated using the predefined modification level as discussed above to have the intensity of the kV CT images to make the two images have the same intensity range as if they were obtained from the same modality. Finally, the dose calculation using kV CT, MVCBCT with/without intensity calibration was applied using radiation treatment planning system. As a result, the percentage difference of dose distributions between dose calculation based on kVCT and MVCBCT with intensity calibration was reduced comparing to the percentage difference of dose distribution between dose calculation based on kVCT and MVCBCT without intensity calibration. For head and neck, lung images, the percentage difference between kV CT and non-calibrated MVCBCT images was 1.08%, 2.44%, respectively. In summary, our method has quantitatively improved the accuracy of dose calculation and could be a useful solution to enhance the dose calculation accuracy using MVCBCT images.

A study on dosimetric comparison of craniospinal irradiation using tomotherpy and reproducibility of position (토모테라피를 이용한 뇌척수조사의 선량적 비교와 자세 재현성에 대한 고찰)

  • Lee, Heejeong;Kim, Jooho;Lee, Sangkyu;Yoon, Jongwon;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.69-76
    • /
    • 2017
  • Purpose: The purpose of this study was to verify dosimetric results and reproducibility of position during craniospinal irradiation (CSI) using tomotherapy (Accuray Incorporated, USA). Also, by comparing with conventional CSI Technique, we confirmed the efficiency of using a Tomotherapy. Materials and Methods: 10 CSI patients who get tomotherapy participate. Patient-specific quality assurances (QA) for each patient are conducted before treatment. When treating, we took Megavoltage Computed Tomography (MVCT) that range of head and neck before treatment, L spine area after treatment. Also we conducted in-vivo dosimetry to check a scalp dose. Finally, we made a 3D conventional radiation therapy(3D-CRT) of those patients to compare dosimetric differences with tomotherapy treatment planning. Results: V107, V95 of brain is 0 %, 97.2 % in tomotherapy, and 0.3 %, 95.1 % in 3D-CRT. In spine, value of V107, V95 is 0.2 %, 18.6 % in tomotherapy and 89.6 %, 69.9 % in 3D-CRT. Except kidney and lung, tomotherapy reduced normal organ doses than 3D-CRT. The maximum positioning error value of X, Y, Z was 10.2 mm, -8.9 mm, -11.9 mm. Through in-vivo dosimetry, the average of scalp dose was 67.8 % of prescription dose. All patient-specific QA were passed by tolerance value. Conclusion: CSI using tomotherapy had a risk of parallel organ such as lung and kidney because of integral dose in low dose area. However, it demonstrated dosimetric superiority at a target and saved normal organ to reduce high dose. Also results of reproducibility were not exceeded margins that estimated treatment planning and invivo dosimetry showed to reduce scalp dose. Therefore, CSI using tomotherapy is considered to efficient method to make up for 3D-CRT.

  • PDF

Effect of environmental temperature on respiration rate, rectal temperature and body-surface temperatures in finishing pigs (환경온도가 비육돈의 호흡수, 직장 온도 및 체표면 온도에 미치는 영향)

  • Cheon, Si-Nae;Park, Kyu-Hyun;Choi, Hee-Chul;Kim, Jong-bok;Kwon, Kyeong-Seok;Lee, Jun-Yeob;Woo, Saem-Ee;Yang, Ga-Yeong;Jeon, Jung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.103-110
    • /
    • 2019
  • Recently, Korea has been affected by extreme weather events including extended summers and increased temperatures caused by global warming and climate change. Environmental temperature is especially important to the livestock industry because it is closely related to livestock productivity. This study was conducted to investigate the influence of different environmental temperatures on respiration rate, rectal temperature and body-surface temperature in finishing pigs. Pigs ($98.3{\pm}6.6kg$) were housed in individual cages inside an experimental chamber and exposed continuously to one of five environmental treatments ($22^{\circ}C$, $24^{\circ}C$, $26^{\circ}C$, $28^{\circ}C$, $30^{\circ}C$) for 10 days without providing additional rest time. Feed and water intake, respiration rate, rectal temperature and body-surface (head, ear, neck, back, side) temperature were measured two times daily during the experimental period. A significant increase in respiration rate from $26^{\circ}C$ and in body-surface temperature from $24^{\circ}C$ (p<0.05) was observed. At $30^{\circ}C$, the respiration rate had almost doubled and the body-surface temperature increased by about $5^{\circ}C-7^{\circ}C$. Moreover, ear skin temperature was very sensitive to environmental temperature. However, feed intake, water intake and rectal temperature did not change significantly during the experiment.

Research to Establish a Common Standard for Assent by Assessing the Current State of the Assent Process and Conducting Interviews with Pediatrician/Pediatric Neurologist (소아승낙 현황조사와 소아청소년과/소아신경과 전문의를 대상으로 면담조사를 통한 소아승낙서 공통기준 수립 연구)

  • Yoon Jin Lee;Sun Ju Lee;Su Jin Kang;Dae Ho Lee;Kyun-Seop Bae;Jong Woo Chung;Byung Soo Kim;Jin Seok Kim;Myung Ah Lee
    • The Journal of KAIRB
    • /
    • v.6 no.1
    • /
    • pp.5-16
    • /
    • 2024
  • Purpose: The purpose of this study is to investigate the current status of pediatric assent in nationwide hospitals and to assess the children's comprehension for pediatric assent by interviewing pediatricians/pediatric neurologists to determine whether children of the age (elementary and middle school students) can understand the purpose, risks, benefits, and concepts of voluntary participation in clinical research described in the assent form, and to help improve the administrative efficiency of multicenter clinical trials. Methods: The status of pediatric assent was surveyed online using Google Forms at 141 university hospitals with administrative staff who are members of the Institutional Review Board (IRB) administrative staff subcommittee with in Korean Association of Institutional Review Boards (KAIRB). Additionally, face-to-face interviews were conducted with 7 pediatricians/pediatric neurologists. Survey and interview responses were summarized using descriptive statistics. Results: Out of the 141 institutions surveyed, 35 institutions (24.8%) responded. Among them, 30 institutions (85.7%) reported having age criteria for acquiring pediatric assent forms in the case of children. The age range for pediatric assent acquisition have been from 7 years old to 12 years old (15 institutions, 50%), and from 7 years old to 15 years old (7 institutions, 23.3%). Nine institutions (25.7%) have had criteria for obtaining both parents' consent in cases involving the participation of children. Nineteen institutions (54.3%) have had checklists or guidelines available for use by IRB members in study protocols involving vulnerable research subjects. Three pediatricians/pediatric neurologists have believed that upper-grade elementary school students (5th-6th grade) could comprehensively understand informed consent forms. Two have believed that middle school students would be able to understand them if they included personal information. Two pediatricians/pediatric neurologists have believed that even lower-grade elementary school students (1st-4th grade) could understand the explanations if they were made simpler. Conclusion: It is suggested that not only elementary school students (7-12 years old) but also middle school students (13-15 years old) should receive pediatric assent forms, as it would facilitate a comprehensive understanding of the forms. To enhance the comprehension of assent form content, it is necessary to use age-appropriate words, language, and expressions in the forms hospital. It is also recommended to create comics or videos to make the content of the assent forms more accessible for children.

  • PDF

Convolution-Superposition Based IMRT Plan Study for the PTV Containing the Air Region: A Prostate Cancer Case (Convolution-Superposition 알고리즘을 이용한 치료계획시스템에서 공기가 포함된 표적체적에 대한 IMRT 플랜: 전립선 케이스)

  • Kang, Sei-Kwon;Yoon, Jai-Woong;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.271-277
    • /
    • 2013
  • In prostate IMRT planning, the planning target volume (PTV), extended from a clinical target volume (CTV), often contains an overlap air volume from the rectum, which poses a problem inoptimization and prescription. This study was aimed to establish a planning method for such a case. There can be three options in which volume should be considered the target during optimization process; PTV including the air volume of air density ('airOpt'), PTV including the air volume of density value one, mimicking the tissue material ('density1Opt'), and PTV excluding the air volume ('noAirOpt'). Using 10 MV photon beams, seven field IMRT plans for each target were created with the same parameter condition. For these three cases, DVHs for the PTV, bladder and the rectum were compared. Also, the dose coverage for the CTV and the shifted CTV were evaluated in which the shifted CTV was a copied and translated virtual CTV toward the rectum inside the PTV, thus occupying the initial position of the overlap air volume, simulating the worst condition for the dose coverage in the target. Among the three options, only density1Opt plan gave clinically acceptable result in terms of target coverage and maximum dose. The airOpt plan gave exceedingly higher dose and excessive dose coverage for the target volume whereas noAirOpt plan gave underdose for the shifted CTV. Therefore, for prostate IMRT plan, having an air region in the PTV, density modification of the included air to the value of one, is suggested, prior to optimization and prescription for the PTV. This idea can be equally applied to any cases including the head and neck cancer with the PTV having the overlapped air region. Further study is being under process.

Molecular Diagnosis of Streptococcus pneumoniae in Middle Ear Fluids from Children with Otitis Media with Effusion (삼출성 중이염 소아의 중이액에서 폐구균의 분자적 진단)

  • Byun, Sung Wan;Kim, Han Wool;Yoon, Seo Hee;Park, In Ho;Kim, Kyung-Hyo
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.2
    • /
    • pp.106-112
    • /
    • 2015
  • Purpose: The long-term administration of antibiotics interferes with bacterial culture in the middle ear fluids (MEFs) of young children with otitis media with effusion (OME). The purpose of this study is to determine whether molecular diagnostics can be used for rapid and direct detection of the bacterial pathogen in culture-negative MEFs. Methods: The specificity and sensitivity of both polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) to the lytA gene of Streptococcus pneumoniae were comparatively tested and then applied for pneumococcal detection in the clinical MEFs. Results: The detection limit of the PCR assay was approximately $10^4$ colony forming units (CFU), whereas that of LAMP was less than 10 CFU for the detection of S. pneumoniae. Both PCR and LAMP did not amplify nucleic acid at over $10^6$ CFU of H. influenzae or M. catarrhalis, both of which were irrelevant bacterial species. Of 22 culture-negative MEFs from children with OME, LAMP positivity was found in twelve MEFs (54.5%, 12/22), only three of which were PCR-positive (25%, 3/12). Our results showed that the ability of LAMP to detect pneumococcal DNA is over four times higher than that of PCR (P<0.01). Conclusions: As a high-resolution tool able to detect nucleic acid levels equivalent to <10 CFU of S. pneumoniae in MEFs without any cross-reaction with other pathogens, lytA -specific LAMP may be applied for diagnosing pneumococcus infection in OME as well as evaluating the impact of a pneumococcal conjugate vaccine against OME.