• Title/Summary/Keyword: Head and neck MR

검색결과 29건 처리시간 0.023초

Gadoteridol을 이용한 Head & Neck MR Angiography에서의 적정 Flip Angle (Optimization of Flip Angle at Head & Neck MR Angiography using Gadoteridol)

  • 정현근;김민기;송재준;남기창;최현성;정현도;김호철
    • 전자공학회논문지
    • /
    • 제53권3호
    • /
    • pp.151-159
    • /
    • 2016
  • 본 연구의 목적은 가돌리늄 조영제를 사용한 Head & Neck MR Angio검사에 있어서 매개변수인 FA(Flip Angle)이 MR신호에 미치는 영향에 대해서 알아보고자 하였으며, 이에 따른 FA의 적정 값을 제시하는 것이다. 실험은 FA증가에 따른 MR팬텀실험과 임상실험으로 진행하였고, 이에 대한 정량적 분석이 이루어졌다. 실험결과 팬텀실험에서의 조영증강 반응시작 지점인 RSP(Reaction Starting Point)는 FA증가에 따라 300~400 mmol 사이에서 반응하였고, 최대 신호강도인 MPSI(Max Peak Signal Intensity)는 2,086, 3,705, 5,109, 6,194, 7.096, 7,192 [a.u]를 기록하였다. MPSI가 형성되는 몰농도 지점인 MPP(Max Peak Point)는 FA에 증가에 따라 40, 50, 50, 40, 50, 40 mmol에서 보였으며, MPSI의 증가율인 IRMPSI(Increase Rate of MPSI)는 77.6%, 37.9%, 21.2%, 14.6%, 1.4%임을 확인하였다. 임상실험에서의 평가기준인 SICB(Signal Intensity of Carotid artery Bifurcation)는 FA증가에 따라 각 평균값 2392.5, 4165.2, 4270, 3502.2, 3263.7, 3119.6 [a.u]를 기록하였고, 아티팩트 발생율인 ORA(Occurence Rate of Artifact)는 0, 0, 20, 40, 50, 70%로 점차 증가하였다. 본 연구를 통하여 FA의 증가는 혈관 내 가돌리늄과 결합한 H1스핀의 신호강도와 아티팩트에 영향을 미친다는 사실을 확인하였고, 이는 실제 임상에서의 CE(Contrast Enhanced)-Head&Neck MR Angio검사에 있어서 본 연구의 데이터를 활용한다면 진단학적으로 효율적인 MR Angiography 영상을 구현할 수 있을 것으로 사료된다.

ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰 (A study of usefulness for the plan based on only MRI using ViewRay MRIdian system)

  • 전창우;이호진;안범석;김찬용;이제희
    • 대한방사선치료학회지
    • /
    • 제27권2호
    • /
    • pp.131-143
    • /
    • 2015
  • 목 적 : MRI를 기반으로 한 CT fusion plan과 MRI only based plan을 비교함으로써 MRI only plan의 유용성을 평가하고, 나아가 Simulation과 치료계획을 포함한 방사선치료의 전 과정을 CT 촬영 없이 MRI 영상으로 구성하여 실시간 MR-IGRT를 구현하고자 한다. 대상 및 방법 : 본원에서 사용중인 BBB CT (Brilliance Big Bore CT, 16slice, Philips)와 Viewray MRIdian System (Viewray, USA)으로 환자 11명(Head and Neck 1명, Breast 5명, Lung 1명, Liver 3명, Prostate 1명)을 대상으로 CT & MR simulation 및 치료계획을 세웠다. Head and Neck, Breast, Prostate환자는 자유호흡(Free Breathing) 상태로, Lung과 Liver 환자는 흡기 호흡중지(Inhalation Breathing Holdng)상태로 Simulation을 진행하였다. Viewray의 Bore 크기 및 Coil 위치를 고려하여 환자 자세 및 고정기구를 동일한 조건을 유지하여 CT simulation을 시행하였다. Viewray MRIdian 시스템을 이용하여 MR 영상을 기반으로 한 CT fusion plan과 CT fusion 없이 [ICRU 46]에서 권고하는 폐, 공기, 뼈의 전자밀도를 입력한 동일한 조건의 MR only plan을 세웠다. Head and Neck, Breast, Prostate는 IMRT, Lung과 Liver 는 Gating치료계획을 세웠고, 치료계획의 평가는 PTV의 균질성 지표 (Homogeneity Index, HI)와 일치성 지표 (Conformity Index, CI), 그리고 각 PTV와 OAR의 DVH와 선량차이를 각각 비교하였다. 결 과 : 두 치료계획간 치료부위별 PTV에 대한 HI 값의 차이는 Head and Neck, Breast, Lung, Liver, Prostate 부위별로 각각 0.089, 0.26, 0.67, 0.2, 0.4%로 나타났으며, CI 값의 차이는 부위별로 각각 0.043, 0.84, 0.68, 0.46, 0.3%로 두가지 평가 값 모두 Head and Neck 부위가 가장 작은 차이를 나타냈다. PTV에 대한 평균선량 차이는 치료부위별로 각각 0.07, 0.29, 0.18, 0.3, 0.18 Gy로 나타났다. 이를 백분율로 나타냈을 때 0.06, 0.7, 0.29, 0.69, 0.44%으로 모두 1% 이하의 차이를 보였다. 두경부암의 각 OAR은 전체적으로 0.01~0.12 Gy의 평균선량 차이를 보였으며, 유방암은 0.04~0.06 Gy, 폐암에서는 0.01~0.21 Gy, 간암은 0.06~0.27 Gy, 전립선암은 0.02~0.23 Gy의 평균선량 차이를 나타냈다. 결 론 : MR 영상을 이용한 치료계획은 연부조직에서 탁월한 대조도를 나타낼 뿐만 아니라 CT fusion한 MR 치료계획과 비교했을 때 PTV의 HI, CI, 선량차이 모두 1%미만의 차이를 보였으며, OAR의 경우 비균질한 조직이 많은 부위일수록 최대 0.89 Gy 선량차이를 보였다. 이결과를 토대로 두경부암, 부분적 유방암이나 전립선암등 비균질도 차이가 적은 부위에는 CT촬영 없이 MR 영상만을 이용한 방사선치료의 가능성을 확인 할 수 있었다.

  • PDF

대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성 (Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • 제2권1호
    • /
    • pp.96-103
    • /
    • 1998
  • 목적 : 고식적인 자기공명혈관조영술 (MR Angiography, MRA) 기법으로는 영상화가 어려웠던 대동맥궁의 주요 분지들의 평가에 있어서 새로운 MR기법인 조영증강 MRA의 임상적 유용성을 알아보고, 그 화질을 사용한 코일의 종류에 따라 비교해 보고자 한다. 대상 및 방법 : 뇌혈관 질환을 의심하여 고식적인 기법으로 뇌 및 경동맥 MRA를 시행한 29명에서 전향적으로 Gd-DAPA 15-20ml를 일시에 손으로 주입한 후 대동맥궁과 그의 주요 분지들에 대해 3시기의 고속 MRA를 시행하여 그 화질을 분석하였다. MRA는 1.0T MR기종에서 3D-FISP기법으로 얻었으며 총 영상 획득 시간은 40-60초였다. 영상 분석은 무명동맥, 양측 총경동맥, 양측 쇄골하동맥과 양측 척추 동맥들의 기시부로부터 전장에 걸쳐 화질을 주관적으로 3등급(good; 명백히 정상소견을 보이는 경우, fair; 약간 낮은 신호를 보이나 정상으로 진단하기에 비교적 만족할 만한 경우, poor; 협착이 모호하거나, 인공물이나 너무 낮은 신호로 혈관을 볼 수 없어 카테터 혈관조영술을 요하는 경우)으로 나누어 평가하였으며, 양측 총경동맥의 분기(bifurcation) 부위에서는 고식적인 기법의 영상과 그 화질을 비교평가하였다. 또한 세가지 사용한 코일의 종류(CP body array 12예, CP neck array 9예, head-and-neck 8예)에 따른 화질 차이를 정성적 및 정량적(신호대 잡음비)으로 분석하였다. 결과 : 대동맥궁 주요 분지들의 전반적인 화질은 55% (16/29)에서 'good', 34%(10/29)에서 'fair'로 평가되어 대부분 고식적인 카테터 혈과조영술이 피요치 않을 정도로 만족할 만한 화질을 보였다. 양측 총경 동맥분지 부위에서는 65%(17/26)에서 고식적인 3D-TOF기법과 같거나 나은 영상을 보였다. CP body array 코일을 사용한 경우가 CP neck array 코일이나 head-and-neck 코일을 사용한 경우보다 정성적 및 정량적으로 유의하게 나은 영상을 보였다(p<0.05). 결론 : 고속 조영증강 MRA기법은 단시간내 (40-60초)에 대동맥구의 주요 분지들을 그 기시부위부터 두개골 저부에 이르기까지 대부분에서 잘 나타내주므로 선별검사로서 임상적으로 유용하리라 생각되며 CP body array 코일을 사용하였을 경우에 CP neck array 코일이나 head-and-neck 코일을 사용한 경우보다 좀더 나은 화질을 얻을 수 있으리라 생각된다.

  • PDF

두경부암 림프절 전이 평가에서 PET-MRI의 임상적 유용성 (Clinical Usefulness of PET-MRI in Lymph Node Metastasis Evaluation of Head and Neck Cancer)

  • 김정수;이홍재;김진의
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.26-32
    • /
    • 2014
  • 수술 전 림프절 전이 여부를 진단하고 병리학적 소견 및 원발 주위조직 전이 평가법을 이용하여 두경부암 PET-MRI 검사의 임상적 유용성을 평가하였다. 두경부암 환자 100명을 대상으로 $^{18}F-FDG$ (5.18 MBq/kg)를 정맥주사하고 60분 안정을 취한 후, BiographTM mMR 3T를 사용하여 torso(body tim coil, Vibe-Dixon)와 dedication (head/neck tim coil, UTE, Dotarem injection) 검사를 시행하였다. 반복계산법을 적용하여 데이터를 재구성한 후 workstation으로 림프절 전이 여부를 판독하고, 본원 종합의료정보시스템으로 수술 전/후 병리학적 검사 소견을 조사하였다. 환자의 진단 정보를 $2{\times}2$ 판정행렬의 각 항목에 기입하여 진양성, 진음성, 위양성, 위음성으로 구분하고 이렇게 구분된 검사결과를 토대로 예민도, 특이도, 정확도, 위음성률, 위양성률을 산출하였다. 두경부암 환자의 PET-MRI 검사 결과에서 림프절 전이 양성 및 음성 판정을 받은 경우는 각 49건, 51건이었으며 수술 전-후 병리학적 결과를 통해 림프절 전이 양성 및 음성 판정을 받은 경우는 각 46건, 54건으로 나타났다. 이 중 두 검사 모두 림프절 전이 양성 판정을 받은 진양성은 45건, PET-MRI 검사에서는 림프절 전이 양성이지만 병리학적 검사에서 림프절 전이 음성 판정을 받은 위양성은 4건, PET-MRI 검사에서 림프절 전이 음성이지만 병리학적 검사에서 양성 판정을 받은 위음성은 1건, 두 검사 모두 림프절 전이 음성 판정을 받은 진음성은 50건으로 분석되었다. 따라서 두경부암 환자의 PET-MRI 검사의 예민도는 97.8%, 특이도는 92.5%, 정확도는 95%, 위음성률은 2.1%, 위양성률은 7.0%로 나타났다. 따라서 PET-MRI는 두경부암의 진단에 있어 수술 전 병기 결정이나 치료 후 재발 및 원격전이의 발견, 불분명한 원발 경부 림프절 전이 등의 평가에 유용할 것으로 판단된다.

  • PDF

의료 영상을 이용한 인체 역학적 구조물 특징 추출 및 영상 분할 (Feature Extraction and Image Segmentation of Mechanical Structures from Human Medical Images)

  • 호동수;김성현;김도일;서태석;최보영;김의녕;이진희;이형구
    • 한국의학물리학회지:의학물리
    • /
    • 제15권2호
    • /
    • pp.112-119
    • /
    • 2004
  • 인체에 대한 표준데이터를 사용하지 않고 실제 한국인의 의료 영상 데이터를 사용하여 인체 모델을 만들고자 하였다. 먼저 CT와 MRI를 통해 획득한 인체의 의료영상에 대한 특징을 분석하였다. 인체의 해부학적인 구성요소에 대해 CT는 gray level로 MR 영상은 펄스시퀀스 별로 분석하여 특징을 추출하였다. 해부학적 구성요소의 특징을 바탕으로 인체 각 부위별로 영상을 얻기 위해 CT와 MR 영상에 대해 영상분할을 수행하였다. 인체의 부위 중 특히 인체의 네 가지 인체 역학적 구조물인 골조직, 근육, 인대, 건 부위를 CT와 MR 영상을 이용하여 구별하였다. 이미지 분할 방법에는 일반적으로 많이 사용되고 있는 경계선 검출(Edge detection), 영역 선택(Region Growing), 문턱치(Intensity Threshold) 방법 등을 선택하여 인체별로 가장 적합한 알고리듬을 적용시켰다. Head/Neck 부위에 대한 영상 분할 결과를 인체 역학적 구성요소별로 3차원 영상으로 재구성하였다.

  • PDF

Improvement of Fat Suppression and Artifact Reduction Using IDEAL Technique in Head and Neck MRI at 3T

  • Hong, Jin Ho;Lee, Ha Young;Kang, Young Hye;Lim, Myung Kwan;Kim, Yeo Ju;Cho, Soon Gu;Kim, Mi Young
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권1호
    • /
    • pp.44-52
    • /
    • 2016
  • Purpose: To quantitatively and qualitatively compare fat-suppressed MRI quality using iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) with that using frequency selective fat-suppression (FSFS) T2- and postcontrast T1-weighted fast spin-echo images of the head and neck at 3T. Materials and Methods: The study was approved by our Institutional Review Board. Prospective MR image analysis was performed in 36 individuals at a single-center. Axial fat suppressed T2- and postcontrast T1-weighted images with IDEAL and FSFS were compared. Visual assessment was performed by two independent readers with respect to; 1) metallic artifacts around oral cavity, 2) susceptibility artifacts around upper airway, paranasal sinus, and head-neck junction, 3) homogeneity of fat suppression, 4) image sharpness, 5) tissue contrast of pathologies and lymph nodes. The signal-to-noise ratios (SNR) for each image sequence were assessed. Results: Both IDEAL fat suppressed T2- and T1-weighted images significantly reduced artifacts around airway, paranasal sinus, and head-neck junction, and significantly improved homogeneous fat suppression in compared to those using FSFS (P < 0.05 for all). IDEAL significantly decreased artifacts around oral cavity on T2-weighted images (P < 0.05, respectively) and improved sharpness, lesion-to-tissue, and lymph node-to-tissue contrast on T1-weighted images (P < 0.05 for all). The mean SNRs were significantly improved on both T1- and T2-weighted IDEAL images (P < 0.05 for all). Conclusion: IDEAL technique improves image quality in the head and neck by reducing artifacts with homogeneous fat suppression, while maintaining a high SNR.

Elliptical Centric과 TRICKS 기법의 임상 적용에 관한 유용성 연구 (Elliptical Centric Techniques and Tricks About the Usefulness of the Clinical Application)

  • 김새싹;구은회;동경래;권대철;이재승;조재환;박창희
    • 대한디지털의료영상학회논문지
    • /
    • 제13권2호
    • /
    • pp.83-90
    • /
    • 2011
  • To prospectively determine the diagnostic performance a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of the head and neck vascular diseases. Over a period of two months, A total of 100 patients(average ages : $50{\pm}8$, male : 60, female : 40) with head and neck vascular diseases were performed on the GE excite 3.0 T units with 8-channel head coil and 4-channel NV coil. Imaging parameters for a typical study were as follow: SBC(TR/ TE/ FA/ SliceThicken./ Slab/ Freq./ FOV/ BW/Scan Time) = 5.4/ min/ 30/ 2/ zip2/ 70/ $224{\times}448$/ 30/ 62.50/ 28, TRICKS(TR/ TE/ FA/ Slice Thicken/Slab/ Freq./ FOV/ BW/ Temp Res./ Scan Time = 3.6/ min/ 25/ 4/ 30/ $160{\pm}384$, zip512/ 30/ 100/ 1 to 1.5/ 23). The analysis of all MR images, which have respect-ively classified two techniques into some diseases. The results of the former were divided into two groups(SBC, TRICKS)with 4 grading of two reader, respectively. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed(p < 0.05). In 33 of 100 patients, arterio-venous malformation was 11% at TRICKS, subclavian vein stenosis : 8%, fistular sinus : 4%, jugular vein stenosis:6%, Middle Cerebral Artery bypass surgery : 4%, p < 0.05). The rest of 67 patients were considered as the results of SBC(14% in the basilar artery stenosis, carotid stenosis : 16%, vertebral stenosis : 17%, central neuro-cytoma : 5%, meningioma : 5%, Not appliable : 10%, p < 0.05). Sensitivity and specificity of TRICKS MR angiography in SVS, FS, JVS, MCABS were improved compared with those at standard MR angiography. In SBS MR angiography which were improved in BAS, CS, VS, CN, Meningioma. In conclusion, TRICKS MR angiography of the SVS, FS, JVS, MCABS is superior to standard MR angiography regarding the number of diagnostic grading. The SBS MR angiography were improved in BAS, CS, VS, CN, Meningioma. and assessment of the degree of luminal narrowing on both TRICKS and SBS.

  • PDF

자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가 (Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원;한지현;이시내;김민지;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

새로운 건강보험 보장성 강화 대책 1부: 뇌 MRI, 뇌혈관/경부혈관 MRA, 두경부 MRI 급여 확대 (A New Healthcare Policy in Korea Part 1: Expanded Reimbursement Coverage of Brain MRI, Brain/Neck MRA, and Head and Neck MRI by National Health Insurance)

  • 김은희
    • 대한영상의학회지
    • /
    • 제81권5호
    • /
    • pp.1053-1068
    • /
    • 2020
  • 문재인 정부의 새로운 건강보험 보장성 강화 대책에 따라 2018년부터 뇌 MRI, 뇌혈관/경부혈관 MRA, 두경부 MRI 급여가 확대되어 시행 중이다. 2018년 10월부터 2020년 4월까지 개정되어 현재 시행 중인 MRI 급여와 관련된 '요양급여의 적용기준 및 방법에 관한 세부사항'을 중심으로 정리해 보았다. 이 종설은 MRI 요양급여체계, 두통, 어지럼증 환자의 급여기준조정, 뇌 MRI, 뇌혈관/경부혈관 MRA, 두경부 MRI의 급여기준, 표준영상, 판독소견서 등을 포함하였다. 이 글을 통해 영상의학과 전문의가 보험 영역에서도 전문적인 지식을 갖추어 영상의학과 전문의의 전문성을 확보하고, 소속병원에서 주도적인 역할을 하는데 도움이 되고자 한다. MRI 급여화 확대 정책이 진행 중으로 관련 보건복지부의 세부고시가 개정될 수 있다. 따라서 MRI와 보험과 관련된 사안을 지속적으로 업데이트하는 것이 요망된다.

대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성 (Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type))

  • 곽영곤;김종일;조영기
    • 한국콘텐츠학회논문지
    • /
    • 제15권11호
    • /
    • pp.313-321
    • /
    • 2015
  • Hip FAI 진단과 수술 계획 시 Hip FAI MRI 검사시 3D 영상을 추가로 활용하여 CT 영상으로 이루어지는 Hip Clock face 영상을 MRI 3D 영상으로 대체할 수 있는지 비교 평가 하였다. Hip 자기공명 영상검사(MRI)와 3D Hip 컴퓨터 단층 촬영(CT)을 동시 시행한 환자 31명 (남: 21명 평균연령: 35세 여: 10명 평균연령: 40.3세)을 대상으로 분석하였으며, 영상평가는 정형외과 전문의 1명과 영상의학과 전문의 1명이 MR과 CT modality에서 Hip joint articular transverse ligament의 6 o'clock을 중심으로 Superior을 12 o'clock, Labrum의 전면을 3 o'clock, 반대쪽을 9 o'clock로 기술하는 Clock face을 재구성 한 후 11 o'clock에서 A. retinacular vessel, B. head neck junction, 12 o'clock A. Epiphyseal line, B. Cam lesion, 1,2,3,4 o'clock의 Cam lesion, Posterior Cam lesion확인 여부를 리커트(Likert scale) 5점 척도로 평가하였다(Independent t-test p<0.05). 리커드 척도 결과 11 o'clock A. retinacular vessel MR 평균 값 $3.69{\pm}1.0$, CT 평균값 $2.8{\pm}0.78$이며 통계적으로 유의하였다(p<0.001). B. head neck junction은 두 평가자간 차이가 없었다(p<0.416). 12 o'clock A. Epiphyseal line MR 평균값 $3.54{\pm}1.00$, CT 평균값 $4.5{\pm}0.62$이었다(p<0.000). B. Cam lesion은 두 평가자간 차이가 없었다(p<0.532). 1,2,3,4 o'clock 의 Cam lesion과 Posterior Cam lesion은 통계적으로 유의하지 않았다(p<0.656, p<0.658). weighted Kappa 검증 결과 11 o'clock A.retinacular vessel CT K값이 0.663으로 가장 낮은 일치도였으며, 각각의 평가 항목의 일치도 평가 결과 매우 높은 결과로 두 평가자간 높은 신뢰도를 보여주었다.