• 제목/요약/키워드: HeNe

검색결과 448건 처리시간 0.03초

1칩 마이크로 프로세서를 이용한 He-Ne 레이저의 주파수 안정화 (Frequency Stabilization of He-Ne laser using One Chip Micro-Processor)

  • 최현승;엄태봉;이선규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.102-105
    • /
    • 2000
  • A simple digital control system has been developed for the frequency stabilization of an internal mirror He-Ne laser. The system is based on one chip microprocessor with embedded Basic interpreter. To stabilize the laser output frequency, the signal such as power difference or beat frequency between two modes is supplied and processed by a microprocessor, and control signal is fed to the heating coil would round the laser tube for adjusting the spacing of the laser cavity mirror. Newly developed frequency stabilization system is totally digitized. The system and the frequency stability performance are briefly described.

  • PDF

Effects of the Low Power He-Ne IR Laser Treatment on the Liver Damage Induced with $CCI_4$ in Rats

  • Rho Min-Hee;Kim Jai-Young
    • 대한의생명과학회지
    • /
    • 제10권3호
    • /
    • pp.231-235
    • /
    • 2004
  • This study was investigated the effects of the lower power He-Ne IR laser treatment on the changes of blood biochemical components in the rat liver damaged by the carbon tetrachloride (CCl₄). The twenty one Sprague-Dawley adult male rats weights (260±18.6 g) were designed to the three groups: one control group and two experimental groups, the experimental groups were divided into the CCl₄-treated groups and the laser therapy group (CCl₄+ Laser). The experimental groups were injected twice with CCl₄(1.0 ml/kg body weight) intraperitoneal for two days. Each group was sacrificed after two weeks irradiated with the lower power He-Ne IR laser for ten minutes per every day. The activity of alanine aminotransferase (ALT), lactic dehydrogenase (LDH), alkaline phosphatase (ALP) and the concentration of serum glucose treated with He-Ne IR laser groups was significantly decreased to the conrtol (treated with carbon CCl₄) group. The activity of aspartate aminotransferase (AST) was decreased in the laser group but not significantly, the concentration of the serum cholesterol in the laser group was significantly increased comparing with the control and case control groups. In conclusion, the effect of the lower power He-Ne IR laser treatment is believed to be a possible protective effects for CCl₄ induced acute hepatotoxicity in rats.

  • PDF

무 수은 면광원에서의 가스 조성 변화에 따른 전기 광학 특성에 관한 연구

  • 오병주;정재철;서인우;황기웅
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.431-431
    • /
    • 2010
  • 본 논문은 기존의 수은 형광 램프와 LED를 대체할 수 있는 무 수은 면광원의 방전 가스 조성 변화(He, Ne, Ar, Xe)에 따른 전기 광학 특성에 관한 연구이다.[1]~[4] 무 수은 면광원의 기본 구조는 그림 1과 같이 방전 공간 내에 유전체에 의해 방전 공간과 분리된 한 쌍의 평행한 전극으로 이루어져 있다. 그리고 방전 공간 내면에는 일정한 두께와 형상을 가지는 형광체가 도포되어 있고 주 전극의 반대 평판유리 외벽에 보조전극을 형성하였다. 방전을 발생시키기 위한 기본적인 구동 방법은 5~25kHz의 주파수와 $0.7{\sim}1.5{\mu}s$의 폭을 가지는 사각 펄스를 사용한다.[4] 그림 2는 Ne-Xe 가스를 기본으로 하여 He 첨가에 따른 전기 광학 특성을 보여준다. He 첨가량이 증가할수록 동작 전압이 높아지면서 방전 개시와 동시에 수축 방전으로 전이되는 형태를 보이며, 효율 또한 감소함을 보였다. 이것은 무 수은 면광원에서는 높은 He의 이차전자 방출 계수보다 He의 높은 이온화 에너지가 더 크게 작용하기 때문이라 생각된다. 그림 3은 Ne-Xe 가스를 기본으로 하여 Ar 첨가에 따른 특성을 보여준다. He과는 다르게 Ar 첨가량이 증가할수록 동작 전압 마진이 넓어진다. 그러나 동작 전압이 상승하고, 효율 역시 감소하는 단점이 있다. 이것은 Ar은 Ne에 비해 이온화 에너지가 낮지만 Ar-Xe 조합은 Penning 효과를 얻을 수 있는 혼합 가스가 아니며, Ar의 2차전자 방출 계수 역시 Ne에 비해 낮기 때문에 결과적으로 방전 전압은 상승하고 효율이 감소하는 결과를 보여준다. 그러므로 무 수은 면광원에서 낮은 구동 전압과 높은 휘도 효율을 얻기 위해서는 Ne-Xe 가스조건이 가장 적합한 가스 조건이다. 효율 개선을 위해서는 Ne-Xe 가스 조건에서 압력을 높이거나 높은 Xe 함량의 가스 조성비를 사용하여 자외선 발광원인 Xe 가스량을 높이는 방법이 가장 유리하다. 그림 4는 Ne-Xe 가스 조건에서 Xe 가스량을 높이면 효율이 증가하는 경향성을 보여준다. 가스 최적화 연구와 더불어 형광체 최적화 연구[5]를 통해서 Ne-Xe25% 100Torr 가스 조건에서 그림 5와 같은 19,000nit의 높은 휘도와 75lm/W의 고 효율 특성을 얻을 수 있었다.

  • PDF

Discharge Characteristics of Low Xe and High Xe Content in He-Ne-Xe Gas Mixture in PDP

  • Kwon, Oh-Yung;Bae, Hyun-Sook;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.366-368
    • /
    • 2008
  • The discharge characteristics of He-Ne-Xe gas mixture with the variation of Xe content are investigated through the numerical simulation. VUV efficacy in the gas condition of low Xe content increases due to more excitation and the case of high Xe content shows the improvement of VUV efficacy with the increase of He content but decreased VUV efficacy after tthe He mixing ratio of He and Ne is 0.5 due to frequent ionization.

  • PDF

AC plasma display panel의 페닝 방전가스 혼합비 변화에 따른 방전특성 연구 (A Study on the Discharge Characteristics with New Penning Gas Mixture for AC plasma display panel)

  • 박문필;이승준;이재경;황호정
    • 한국진공학회지
    • /
    • 제11권2호
    • /
    • pp.127-134
    • /
    • 2002
  • 본 논문은 AC PDP에서 사용하는 가스의 혼합비, 압력, 페닝 효과를 고려한 가스 조합의 최적화를 통해 낮은 방전전압으로 휘도의 증가를 얻을 수 있는 고휘도, 고효율 PDP 페닝 기체 혼합비를 찾고자 하였다. He(70%)-Ne(27%)-Xe(3%)의 3원 혼합기체와 Ne(96%)Xe(4%)의 2원 혼합기체에 페닝 효과를 극대화하기 위한 소량의 Ar, Kr을 첨가하여 각각의 첨가비에 따른 방전 개시전압, 방전 유지전압, 휘도, 발광효율 등을 측정하였다. 또한 페닝효과에 의한 방전 공간상의 전자수 증가를 확인하기 위해 셀 내의 전극 위에 쌓이는 벽전하 양을 측정하였다. 소량의 Ar(0.01%-0.03%) 또는 Kr(0.01%-0.03%)을 HE-Ne-Xe과 Ne-Xe 혼합가스에 첨가했을 때 페닝효과에 기인하여 휘도 및 발광효율이 각각 최고 10%-20% 증가하였다. 또한 페닝효과를 확인하기 위한 벽전하의 양은 10%-25% 증가를 보였다. 방전개시전압 및 최소방전유지전압은 대략 2V-3V정도 감소하였다.

Optimum Condition for Xe Gas Excitation in Plasma Display Panels through Ternary Gas of He, Ne, Xe

  • Khorami, Alireza;Ghanbari, Shirin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.744-747
    • /
    • 2009
  • Plasma Display Panels (PDPs) have illustrated impressive results in terms of light emission efficiency of the Ne-Xe mixture compared with the He-Xe mixture. However, He-Xe has shown to achieve superior color purity. This paper presents the optimization of excitation efficiency and color purity for He-Ne-Xe ternary gas mixtures. Furthermore, we investigate the effect that a protective dielectric layer has on UV photon efficiency in a matrix known as electrode type PDP.

  • PDF

He-Cd 레이져를 이용한 비정질 칼코계나이드 박막의 relief 격자 형성 (Amorphous chalcogenide thin films of relief grating formation by using He-Cd laser)

  • 이기남;박정일;양성준;이영종;정홍배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1058-1061
    • /
    • 2003
  • In this thesis, we observed the optical characteristic of amorphous chalcogenide thin films by He-Cd laser. Also, grating formation by He-Ne laser and He-Cd laser. After analyze diffraction efficiency of the time on the $Ag(200{\AA})/As_{40}Ge_{10}Se_{15}S_{35}$ thin films. The result diffraction efficiency of Maximun 0.2% reduced according to time grating formation by He-Ne laser. Diffraction efficiency of Maximun 0.1% showed stabiliy characteristic according to time grating formation by He-Cd laser.

  • PDF

저용량(低容量) He-Ne 레이저침의 혈락적용(血絡適用) 연구(硏究) (The Study on the Application of He-Ne Laser with Low Energy ILIB to the Superficial Venules)

  • 김성철;조은희;나창수
    • Korean Journal of Acupuncture
    • /
    • 제20권3호
    • /
    • pp.35-47
    • /
    • 2003
  • Objective : The purpose of this study was to investigate the significance of the Oriental medical treatment using He-Ne laser with low energy intravascular Laser Irradiation of Blood(ILIB) through the superficial venules. Methods : The investigation of details connected with the superficial venules in the literature is performed. The investigation of details connected with the pricking blood techniques through the superficial venules in the literature is performed. The classification of the pricking blood techniques through the superficial venules by the blood-letting puncture methods in the literature is performed. The arrangement of domestic clinical treatises on the effectiveness of medical treatment using He-Ne laser with low energy ILIB through the superficial venules is performed. The consideration on the methodology for the improvement of the clinical effectiveness of He-Ne laser with low energy ILIB through superficial venules is performed. Results and Conclusions : The superficial venules are small arteries, veins and capillaries in the superficial region of the human body. In the pricking blood techniques, there are the blood-letting puncture using the implement of acupuncture to the Jing points, Extra points and superficial blood vessels and the acupuncture using the Hirudo. The methods of the blood-letting puncture are classified into the venous blood-letting puncture, the pricking , the picking out white fiber-like substances from the subcutaneous tissue, the cluster needling, the scattered needling, the blood-letting puncture of the tready collateral branch of the large channel and the blood-letting puncture of skin. The He-Ne laser with low energy ILIB through the superficial venules belongs to the Oriental medical treatment as the method of the blood-letting puncture in the vein of cubital fossa. The He-Ne laser with low energy ILIB has an effect on hyperfibrinogenemia, hyperlipidemia, speech and motor dysfunction in the case of cerebral infarction, headache, dizziness, pain and numbness. It is considered that fundamental research on the biological change of the human body, the experimental animal and the unicellular animal, and research on the effectiveness and the safety, and the development of He-Ne laser with low energy ILIB of an effective wavelength range are necessary.

  • PDF

Influence of gas mixture He-Ne-Xe on the vacuum ultraviolet intensity in ac-PDPs.

  • Yoo, N.L.;Jung, K.B.;Lee, J.H.;Lee, S.B.;Han, Y.K.;Jeong, S.H.;Lee, H.J.;Son, C.G.;Lim, J.E.;Oh, P.Y.;Moon, M.W.;Jeoung, J.M.;Ko, B.D.;Cho, G.S.;Uhm, H.S.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1221-1224
    • /
    • 2005
  • The improvement of luminance and luminous efficiency is the one of the most important parts in AC-PDPs. To achieve high luminance and luminous efficiency, high VUV emission efficiency is needed. We measured the emission spectra of the vacuum ultraviolet(VUV) rays in surface discharge AC-PDP with ternary gas mixture of He-Ne-Xe. The influence of He-Ne-Xe gas-mixture ratio on excited $Xe^{\ast}$ resonant atoms and $Xe_2\;^{\ast}$ dimers has been investigated. It is found that luminous efficiency of ternary gas mixture, He-Ne-Xe, is shown to be much higher than that of binary gas mixture of Ne-Xe. For improving discharge luminous efficiency, we have studied VUV emission characteristics of ternary gas mixture, He(50%)-Ne-Xe and He(70%)-Ne-Xe with Xe concentration and filling gas pressure.

  • PDF

Binary and ternary gas mixtures of He-Ne-Xe for improvement of vacuum ultraviolet luminous efficiency in ac-PDPs.

  • Jung, Kyu-Bong;Lee, Jun-Ho;Park, Won-Bae;Jeon, Wook;Oh, Phil-Young;Cho, Guang-Sup;Uhm, Han-Sup;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.522-524
    • /
    • 2004
  • The improvement of luminance and luminous efficiency is the one of the most important part in AC-PDPs. To achieve high luminance and luminous efficiency, high VUV emission efficiency is needed. We measured the emission spectra of vacuum ultraviolet(VUV) rays in surface discharge AC-PDP with binary and ternary gas mixtures of Ne-Xe and He-Ne-Xe. The influence of He-Ne-Xe gas-mixture ratio on excited $Xe^{\ast}$ resonant atoms and $Xe_2$$^{\ast}$ dimers has been investigated. It is found that luminous efficiency of ternary gas mixture, He-Ne-Xe, is shown to be much higher than that of binary gas mixture of Ne-Xe.

  • PDF