• Title/Summary/Keyword: He-Ne laser

Search Result 323, Processing Time 0.026 seconds

Improvement of Measurement Accuracy for Absolute Height by Using Two Types of Doppler and Heterodyne Optical Interferometry (도플러방식과 헤테로다인 방식의 광간섭법을 병용한 절대높이 측정 정밀도 향상)

  • Ahn, Geun-Sik;Jhang, Kyung-Young;Moon, Heui-Kwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.6
    • /
    • pp.128-135
    • /
    • 1996
  • This paper proposes a high precision measurement technique to obtain the height of gage block with a few millimeter height. The proposed technique is consisted of two steps : In the first step, laser position transducer and electric micrometer are adopted to obtain a coarse value of the height of gage block, and then, in the second step, heterodyne laser interferometry is adopted to acquire the precision value. A new kind of phase detector is constructed in the low cost for the heterodyne interferometer and its linearity with ${\pm}1%$ is confirmed by experiment. Also measurement error factors due to enviroments are discussed and methodology to reduce such errors is proposed. Preliminary experiments are carried out for the gage blocks of as high as a few millimeter.

  • PDF

Review of the Properties of the Laser and the Spectrum of Laser Instruments for Diabetic Ulcer (당뇨병성 궤양에 사용되는 레이저의 특성에 대한 연구)

  • Kang, Ki-wan;Kang, Ja-yeon;Jeong, Min-jeong;Kim, Hong-jun;Seo, Hyung-sik;Jang, In-soo
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.29 no.4
    • /
    • pp.14-23
    • /
    • 2016
  • Objectives : One of major complications of diabetes, diabetic ulcer is also one of the main reasons for amputation, and the prevalence rate is 4-10%. Laser therapy is widely used for leg ulcer and diabetic ulcer, and it is known to improve wound epithelialization, cellular content, and collagen deposition. The purpose of this study is to investigate the properties of the laser and the spectrum of laser instruments for diabetic ulcer. Methods : We performed literature search using the PubMed, Cochrane, CINAHL and Web of science for the data in English. In addition, other databases were checked for different languages such as OASIS and NDSL for the literature in Korean, CNKI in Chinese, and CiNii and J-STAGE written in Japanese. We excluded all review article and experimental studies, and only clinical studies using laser or light emitting diode (LED) for diabetic ulcer were selected. Results : A total twenty papers were selected. Different light sources were used as follows: LED, HeNe, InGaAlP, GaAlAs, GaAs, CO2, and KTP. The number of LED studies was 9, and HeNe laser was 7, and InGaAlP and GaAlAs laser was 2, GaAs, CO2, and KTP laser was 1 for each. Various energy density of the clinical study were reported. Conclusions : It is suggested that to select appropriate laser type and give the adequate output power to treat diabetic ulcer. Further evaluation and research for the condition of laser therapy to treat diabetic ulcers are warranted.

Manufacture of an Acousto-Optical Spectrometer for Radio Astronomical Observations (우주전파관측용 음향광학 전파분광기의 제작)

  • 임인성;최재현;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.1
    • /
    • pp.1-12
    • /
    • 1997
  • The acousto-optical spectrometer as a new type backend of the receiver system for radio astronomical observations is manufactured for radio signal analysis. We studied on the effect of Acousto-Optic and Acousto-Optic devices and designed the optics system. We manufactured the optical mount and the CCD detector for deflected beam and interface card. This acousto-optical spectrometer consisted of a laser, optics, acousto-optic deflector, CCD detector and Interface card. This system use He-Ne laser as a light source and use optics to get parallel beam and to focus the deflected beam. Acousto-optic deflector converts IF signal to ultrasonic wave and deflect the laser beam according to the Bragg deflection. The ultra wide band acousto-optic deflector has 1 GHz bandwidth and a total of 2,048 channel Charge Coupled Device for signal detection. In this study, we discuss the theoretical description on the effect of Acousto-optics, the design of the optics, manufacture of optical mount, CCD detector, interface card and we presented the results of experiment. As a result of measurement, we have 1,000 channels bandwidth from CCD channels.

  • PDF

Study on the Effective Focal Volume Change due to Light Intensity Using Fluorescence Correlation Spectroscopy (형광상관분광법을 이용한 광세기에 따른 유효 초점 부피 변화에 대한 연구)

  • Jeong, Chanbae;Lee, Jaeran;Kim, Sok Won
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.2
    • /
    • pp.71-76
    • /
    • 2013
  • Using fluorescence correlation spectroscopy, we analyzed the change of effective focal volume of a confocal system with light intensity. The fluorescence correlation spectroscopy system was home-built in accordance with the He-Ne laser with a wavelength of 632.8 nm, and two kinds of samples (AlexaFluor657 and Quantum dot655) suitable for the wavelength of the laser beam were used. For each sample, we analyzed and compared the correlation functions obtained while changing the intensity of the light source in a range of 1~50 ${\mu}W$. The result shows that the radius of the focal area increases linearly through the increase of particle number and diffusion time in response to an intensity change in weak light below 10 ${\mu}W$. In the higher intensity region (>10~15 ${\mu}W$), the increasing rate of particle number and diffusion time keep increasing but at a much slower rate. Through this result, it was also found that the radius increasing rate of the focal area was reduced however, the radius still increased slightly.

Laser absorption spectroscopy of ternary gas mixture of He-Ne-Xe in External Electrode Fluorescent Lamp (EEFL) (레이저 흡수 분광법을 이용한 He-Ne-Xe 상종가스의 외부전곡 램프의 $1s_4$ 공명준위와 $1s_5$ 준안정준위의 제논 원자 밀도에 대한 연구)

  • Jeong, S.H.;Oh, P.Y.;Lee, J.H.;Cho, G.S.;Choi, E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.576-580
    • /
    • 2006
  • Mercury-free lamp, external electrode fluorescent lamp (EEFL) which includes the xenon gas, is now going on the research for the replacement of mercury lamp. The densities of excited xenon atom in the $1s_4$ resonance state and the $1s_5$ metastable state are investigated in the EEFL by a laser absorption spectroscopy under various gas pressures. We have measured the absorption signals for both $1s_4$ resonance and the $1s_5$ metastable state in the EEFL by varying the discharge currents for a given pressure. This basic absorption characteristic is very important for improvement of the VUV luminous efficiency of the EEFL as well as plasma display panel.

A Study on the Photographic Characteristics of Laser Scanner Film (Laser Scanner 필름의 사진특성에 관한 연구)

  • Kim, Yeoung-Chan
    • The Journal of Information Technology
    • /
    • v.8 no.2
    • /
    • pp.53-58
    • /
    • 2005
  • In this study, we made experiments the preparation of silver halide microcrystals, physical ripening, chemical ripening, spectral sensitivity, additives and coating in order to develop medical laser scanner film which has photographic characteristic suitable for exposure to He-Ne and Ar laser. In the practice of sensitometry, the photographic material is exposed to a known quantity and quality of radiant energy, developed under standard conditions, and the densities resulting from the various exposures are then measured. The results are usually expressed in graphic form as curves, and from these curves numerical values are derived which are used to specify the characteristics of the material.

  • PDF

Crystal Growth of Nd;YCOB and Fabrication of RGB Laser Device (Nd:YCOB 단결정 성장과 RGB 레이저 소자 제조)

  • 김충렬;석상일;장원권;김도진;유영문
    • Korean Journal of Crystallography
    • /
    • v.12 no.1
    • /
    • pp.5-9
    • /
    • 2001
  • Nd/sub 0.05/Y/sub 0.95/Ca₄O(BO₃)₃(Nd:YCOB) single crystals were grown by the Czochralski method using a iridium crucible under N₂ atmosphere. Optimum growth parameters to get high quality of single crystals were 1.5∼2 mm/hr of growth rate and 10∼20 rpm of rotation rate. The grown crystals were transparent with light purple color and well-developed in cleavage planes. The crystal structure of Nd;YCOB were identified to monoclinic by XRD method. Crystal defects acting as light scattering centers, such as micro-pores, secondary phases, inclusions and cracks were not observed under the He-Ne laser illuminations. Three red, green, blue laser devices for the RGB laser oscillations were designed and then fabricated from the grown Nd:YCOB crystals according to the phase-matching angles of negative type-I which were φ=16.40°, 33.95° and θ=22.59° with the flatness of λ/6 at least, respectively.

  • PDF

Design of Precision Position Measuring System using Laser Interferometry (광간섭법을 이용한 정밀 위치측정 시스템 설계)

  • 김진상;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.145-149
    • /
    • 1997
  • A laser mesurement system, a modified Michelson interferometer,which can accurately measure high speed length and position of servomechanisms by detecting a phase shift in the measurement beam using an optical interference was developed. A frequency stabilized laser source and a 20 fold frequency interpolation and digitizing circuit were applied to the system. The refractive index of the ambient air was calibrated through the Edlen's formula. The system achieved a resolution of .lambda./40,16nm, a maximum allowable measurement speed of 600 mm/sec, and a length measurement range of 1500mm. Performance of the system was evaluated on the machining center in short and long length measurements

  • PDF

Implementation of the laser scanning using the step motor (스텝모터를 활용한 정밀 스케닝 구현에 관한 고찰)

  • Chun, Sam-Suk;Park, Chan-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.967-968
    • /
    • 2007
  • This report is the study for laser scanning. Scanning control of $CO_2$ laser, He-Ne laser, used for the treatment of body skin, has relatively low band about hundered Hz. It could be used as a substitiute for expensive galvanometer that is the established scan method, which operates the number of KHz movement by using step motor when it operates low speed. To increase the accuracy of step motor's the angle of rotation, We could materialize 100Hz low band by using open loop, closed loop method with microprocessor. This causes it to be stable even direction by attaching electric capacity sensor. Therefore, We could expect to reduce the cost by manufacturing low band scanner rather than costly feedback galvanometer.

  • PDF

Design and Analysis of Displacement/Length Measuring System Using Laser Interferometry (광간섭법을 이용한 변위/길이 측정시스템의 설계 및 해석)

  • Kim, J.S.;Kim, S.C.;Chung, S.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.151-156
    • /
    • 1997
  • A laser measurement system, a modified Michelson interferometer, which can accurately measure high speed length and displacement of servomechanisms by detecting a phase shift in the measurement beam using an optical interference was developed. A frequency stabilized laser source and a 20 fold frequency interpolation and digitizing circuit were applied to the system. The refra- ctive index of the ambient air was calibrated through the Edlens formula. The system achieved a resolution of /40, 16nm, a maximum allow-able measurement speed of 600nm/sec, and a length measure- ment range of 1500 mm. Performance of the system was evaluated on the machining center in short and long length measurements.

  • PDF