• Title/Summary/Keyword: Hazardous material

Search Result 331, Processing Time 0.027 seconds

The Methodology for Prediction and Control of Hazardous Chlorine Gas Flow Releases as Meteorological Data (기상조건에 따른 유해독성염소가스의 가상흐름누출에 관한 예측 및 제어론)

  • Kim, Jong-Shik;Park, Jong-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.10 no.8
    • /
    • pp.1155-1160
    • /
    • 1999
  • The screening methodology modeling, dispersion modeling procedures for continuous and instantaneous releases of the gas phase flow from the storage tank and pressure relief valve were considered. This study was performed to develop the screening methodology for prediction and control of hazardous/toxic gas releases by estimating the 1-hr average maximum ground-level concentration of $Cl_2$ gas vs. downwind distance by incorporating source term model including the general/physical properties of released material and release mode of the $Cl_2$ storage tank of the chemical plant facilities, dispersion model, and meteorological/topographical data into the TSCREEN model. As the results of the study, it was found that dispersion modes of the dense gas were affected by the state of the released material, the released conditions, physical-chemical properties of released material, and the released modes (continuous and instantaneous releases), and especially largely affected by initial (depressurized) density of the released material and release emission rate as well as the wind velocity. Especially, this study was considered to release hazardous material as meteorological data. It was thought that this screening methodology can be useful as a preliminary guideline for application of the refined analysis model by developing the generic sliding scale methodology for various senarios selected.

  • PDF

Analysis on the Legal Control Levels and GHS Classification Information Status for Strongly Acidic Hazardous Materials (강산성 유해화학물질의 법적관리 수준 및 GHS 분류정보 제공 실태분석 연구)

  • Lee, Kwon Seob;Jo, Ji Hoon;Park, Jin Woo;Song, Se Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.384-392
    • /
    • 2013
  • Objective: This study inspected incident cases, legal control levels, and GHS(Globally Harmonized System of Classification and Labeling of Chemicals) classification results of strong acids such as hydrogen fluoride, hydrogen chloride, nitric acid, and sulfuric acid, which have been responsible for many recent chemical accidents. As a result, it is deemed necessary for legal control levels of these strong acids to be revised and GHS classification be managed nation-wide. Methods: This study inspected incident cases and legal control levels for strong acids such as hydrogen fluoride, hydrogen chloride, nitric acid, and sulfuric acid. The study analyzed and compared chemical information status and GHS classification results. Results: There were 76 domestic incidents involving strongly acidic hazardous materials over the five years between 2007 and 2011. They include 37 leakage incidents(46.7%) within a workplace, 30 leakage incidents(39.5%) during transportation, and nine leakage incidents(13.8%) following an explosion. The strongly acidic materials in question are defined and controlled as toxic chemicals according to the classes of Substances Requiring Preparation for Accidents, Managed Hazardous Substance, Hazardous Chemical(corrosive) as set forth under the Enforcement Decree of the Toxic Chemicals Control Act and Rules on Occupational Safety and Health Standards of Occupational Safety and Health Act. Among them, nitric acid is solely controlled as a class 6 hazardous material, oxidizing liquid, under the Hazardous Chemicals Control Act. The classification results of the EU ECHA(European Chemicals Agency) CLP(Commission Regulation(EC) No. 790/2009 of 10 August 2009, for the purposes of its adaptation to technical and scientific progress, Regulation(EC) No 1272/2008 of the European Parliament and of the Council on classification, labeling and packaging of substances and mixtures) and NIER (National Institute of Environmental Research) are almost identical for the three chemicals, with the exception of sulfuric acid. Much of the classification information of NITE (National Institute of Technology and Evaluation) and KOSHA(Korea Occupational Safety and Health Agency, KOSHA) is the same. NIER provides 12(41.4%) out of 29 classifications, as does KOSHA.

Proposal for Ignition Source and Flammable Material Safety Management through 3D Modeling of Hazardous Area: Focus on Indoor Mixing Processes (폭발위험장소 구분도의 3D Modeling을 통한 점화원 및 가연물 안전관리 방안 제안: 실내 혼합공정을 중심으로)

  • Hak-Jae Kim;Duk-Han Kim;Young-Woo Chon
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.47-59
    • /
    • 2024
  • Purpose: This study aims to propose measures for the prevention of fire and explosion accidents within manufacturing facilities by improving the existing classification criteria for hazardous locations based on the leakage patterns of flammable liquids. The objective is to suggest ways to safely manage ignition sources and combustible materials. Method: The hazardous locations were calculated using "KS C IEC 60079-10-1," and the calculated explosion hazard distances were visualized in 3D. Additionally, the formula for the atmospheric dispersion of flammable vapors, as outlined in "P-91-2023," was utilized to calculate the dispersion rates within the hazardous locations represented in 3D. Result: Visualization of hazardous locations in 3D enabled the identification of blind spots in the floor plan, facilitating immediate recognition of ignition sources within these areas. Furthermore, when calculating the time taken for the Lower Explosive Limit (LEL) to reach within the volumetric space of the hazardous locations represented in 3D, it was found that the risk level did not correspond identically with the explosion hazard distances. Conclusion: Considering the atmospheric dispersion of flammable liquids, it was concluded that safety management should be conducted. Therefore, a method for calculating the concentration values requiring detection and alert based on realistically achievable ventilation rates within the facility is proposed.

Study on the Emission Characteristics of Heavy metals in sewage sludge Incinerator (하수슬러지 소각시설의 중금속 배출특성에 관한 연구)

  • Park, Jung-Min;Lee, Sang-Bo;Kim, Min-Jung;Kim, Jin-Pil;Kim, Jong-Chooun;Lee, Suk-Jo;Lee, Sang-Hak
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.3
    • /
    • pp.28-36
    • /
    • 2009
  • We have closely examined the concentration change characteristics, emission amounts, and the material balance of hazardous air pollutants at both early and later stages of the prevention facilities. These results will be uses as the basic data when preparing for the regulatory and management plans for hazardous air pollutants. The results of the study on heavy metals illustrated that the content of heavy metals in sludge across five facilities were as follows: copper> zinc> chrome> nickel> cadmium> mercury. In terms of heavy metal content in swage sludge, the sludge in incinerating facilities other than the sludge in the D incinerating facility containing industrial water waste, was examined in order to satisfy the ocean contamination standard and fertilizer specifications. Most of the items were shown to have satisfied the emission tolerance standards in the latter part of the prevention facilities(The average elimination rate was over 90%). Therefore, it is concluded that swage sludge containing high-concentrate heavy metals needs to be incinerated rather than recycled as fertilizer.

A Study on Risk Assessment in Transporting Hazardous Material (위험물질 수송 시 위험성 평가에 관한 연구)

  • Ryu Byung Tae;Ko Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.4 s.18
    • /
    • pp.53-58
    • /
    • 2002
  • In this research, the goal is to ascertain the potential danger when transporting hazardous material by considering the important elements that contribute to such situation, instead of relying on the quantitative risk assessment of fixed facilities. Also, this study will verify the social and personal risk according to damage zone limits, by applying the worst case scenario and the alternative scenario that occur during the transportation process. Moreover, it has selected the optimum transportation route for maximum safety. The result of this research could be used to construct a systematic emergency system that can minimize the damage from serious industrial accidents, by effectively decreasing the danger zone and forming a connection between the community, the society, and the industries according to such evaluations.

  • PDF

The PVC Membrane Electrode for Measuring Hazardous Anion in Waste Water Process (폐수처리 공정중 유해음이온을 측정하기 위한 PVC 막 전극)

  • Woo, In-Sung;An, Hyung-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.47-59
    • /
    • 1995
  • The perchlorate, thiocyanate, and nitrate ion-selective PVC membrance electrode for measuring hazardous anion in waste water were developed by incorporating the quaternary ammonium salts as active material. Ion-selective characteristics in waste water were studied by the useful pH range, the selective coefficients to various interfering anions, and the stability of electrode potential. DBP was best as a plasticizer. The effect of the membrane thickness on the electrode characteristics was improved with decreasing the membrane thickness, but below the optimum membrane thickness the electrode exhibited an inverse trend. The electrode potential of perchlorate, thiocyanate, and nitrate electrode with TDDA, as active material, was stable within the pH range 4-11, 3-12, and 4-10 repectively. And the long-term potential stability of these electrodes were 3.0, 3.5, and 3.5 months respectively. The order of the selectivity coefficients was as shown below ; $ClO_4{^-}$ > $SCN^-$ > $I^-$ > $NO_3{^-}$ > $Br^-$ > $CN^-$ > $F^-$ > $Cl^-$ > $Ac^-$ > $H_2PO_4{^-}$, $SO_4{^-}$.

  • PDF

Evaluation of Physical, Mechanical Properties and Pollutant Emissions of Wood-Magnesium Laminated Board (WML Board) for Interior Finishing Materials

  • PARK, Hee-Jun;JO, Seok-Un
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.86-94
    • /
    • 2020
  • This study serves as basic research for the development of a new wood-based building finishing material that improved the weakness of inorganic materials such as gypsum board and magnesium board widely used as interior finishing materials and brought out the strength of the wood. The results of evaluating the physical and mechanical properties and the environmental effect related to hazardous substance discharge having manufactured a wood-magnesium laminated composite are as follows. The thermal conductivity and thermal resistance of WML board was improved by about 28~109 percent over magnesium board due to the low thermal conductivity of wood. The adhesive strength of WML board showed a similar result to that of plywood as it exceeds 0.7N/㎟, the adhesive standard of wood veneer which is presented by KS F 3101. Bending strength and screw holding strength were more improved by manufacturing WML board than magnesium board. The WML board manufactured in this study satisfied the criteria for emissions of hazardous substances prescribed in the Indoor Air Quality Control Act, and confirmed the possibility of development as a new wood-based composite material that can replace existing inorganic materials.

Measurement and Prediction of Combustion Properties of n-Phenol (페놀의 연소특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.23-29
    • /
    • 2018
  • The fire and explosion properties necessary for waste, safe storage, transport, process design and operation of handling flammable substances are lower explosion limits(LEL), upper explosion limits(UEL), flash point, AIT( minimum autoignition temperature or spontaneous ignition temperature), fire point etc., An accurate knowledge of the combustion properties is important in developing appropriate prevention and control measures fire and explosion protection in chemical plants. In order to know the accuracy of data in MSDSs(material safety data sheets), the flash point of phenol was measured by Setaflash, Pensky-Martens, Tag, and Cleveland testers. And the AIT of phenol was measured by ASTM 659E apparatus. The explosion limits of phenol was investigated in the reference data. The flash point of phenol by using Setaflash and Pensky-Martens closed-cup testers were experimented at $75^{\circ}C$ and $81^{\circ}C$, respectively. The flash points of phenol by Tag and Cleveland open cup testers were experimented at $82^{\circ}C$ and $89^{\circ}C$, respectively. The AIT of phenol was experimented at $589^{\circ}C$. The LEL and UEL calculated by using Setaflash lower and upper flash point value were calculated as 1.36vol% and 8.67vol%, respectively. By using the relationship between the spontaneous ignition temperature and the ignition delay time proposed, it is possible to predict the ignition delay time at different temperatures in the handling process of phenol.

A Study on the Awareness of Material Safety Data Sheet (MSDS) of University Laboratory Workers (대학 연구활동종사자의 물질안전보건자료(MSDS) 인식에 관한 연구)

  • Kim, Hong-Kwan;Chon, Young-Woo;Ko, Kwang-Hoon;Hwang, Yong-Woo;Kim, Jung-Soo;Lee, Ik-Mo
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.87-94
    • /
    • 2018
  • The study is aimed to analyze the MSDS awareness as per the properties, including general characteristics, of laboratory workers in university. It conducted the self-administered survey on the subject of 780 laboratory workers engaging in research activities in three university from February to May, 2017. Among them, it analyzed 686 cases except 94 of them, lacking content. As a result, education experience of MSDS, necessity of education, usage experience of MSDS, installation, comprehension, and accessibility showed a strategically significant difference in the recognition of MSDS. According to the categorical importance of MSDS, "the first aid measures" directly related to life was most significantly considered. It is estimated that it will contribute to prevention of safety accident by strengthening education on MSDS and increasing the level of awareness for laboratory workers.

HNS Detection Properties of Printed Ag:CNT Film as Liquid Sensor (Ag:CNT 인쇄박막 액체 센서의 위험유해물질 검출 특성)

  • Ko, Dongwan;Choi, Junseck;Lee, Sangtae;Chang, Jiho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.3
    • /
    • pp.223-228
    • /
    • 2019
  • We fabricated a printed Ag:CNT film as a liquid sensor for the detection of HNS (hazardous and noxious substances) in seawater. The paste required for printing was prepared using Ag powder, MWCNTs (multi-walled carbon nanotubes), and an organic binder. The heat treatment process for binder removal was optimized. In order to confirm that the sensor was operational, the resistance change characteristics in brine (3.5%) and methanol (99.8%) were assessed at $20^{\circ}C$. EDL (electrical double layer) formation and redox reactivity were confirmed as the most important reactions affect each electrical property of sensor in brine and methanol. From these results, it was determined that printed Ag:CNT film can be applied as a sensor to detect HNS in seawater.