• Title/Summary/Keyword: Hazardous area

Search Result 394, Processing Time 0.027 seconds

Adsorptive Removal of Hazardous Organics from Water with Metal-organic Frameworks (금속-유기 골격체(Metal-organic Frameworks)를 활용한 물로부터의 유해 유기물의 흡착 제거)

  • Seo, Pill Won;Song, Ji Yoon;Jhung, Sung Hwa
    • Applied Chemistry for Engineering
    • /
    • v.27 no.4
    • /
    • pp.358-365
    • /
    • 2016
  • Removing hazardous materials from water resources is very important for efficient utilization of the resources, and adsorptive removal is regarded as a competitive technology when good adsorbents with high capacity/selectivity are available. Metal-organic framework (MOF), composed of both organic and inorganic (metallic) species, have been tried for various adsorptions because of huge surface area/pore volume, well-defined pore structure, and facile functionalization. In this review, we summarized technologies on adsorptive removal of hazardous organics from water mainly using MOFs as adsorbents. Instead of reporting high adsorption capacity or rate, we summarized mechanisms of interaction between adsorbates (organics) and adsorbents (MOFs) and methods to modify or functionalize MOFs for effective adsorptions. We expect for readers of this review to understand needed characteristics of adsorbents for the adsorptive removal, functionalization of MOFs for effective adsorption and so on. Moreover, they might have an idea on storage and delivery of organics via understanding of the mechanism of adsorption and interaction.

Characteristics of Exhaust Emissions from a Heavy-duty Diesel Engine (대형디젤엔진의 오염물질 배출특성)

  • 엄명도;류정호;이종태;임철수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.20-27
    • /
    • 1999
  • The proportion of diesel vehicle is very high in this country . PM and NOx emitted from diesel-posered vehicle is severely ;affecting to be air quality . Especially, diesel particulate matters(DPM) including black smoke are hazardous air pollutants to human health and environment. In order to reduce the exhaust emissions from diesel engines, it is necessary to analyze the characteristics of exhaust emissions from diesel engines in various driving conditions. Recently, there are occasion to increase the fuel consumption rate to engine power up. So, in this study we have tested a diesel engine detached from in use -diesel vehicle and analyzed exhaust emission by driving condition and fuel dispersion rate. From this results, we will prepare the comprehensive management plan for exhaust emissions from diesel vehicles and contribute to the improvement of air pollution in urban area.

  • PDF

A Study on the Ventilation in a Long Road Tunnel (종류식 도로터널내에서의 환기 거동에 관한 연구)

  • Yang, Pan-Seok;Cho, Young-Jin;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.8
    • /
    • pp.1091-1100
    • /
    • 1998
  • Longitudinal distributions of the extinction coefficient and concentrations of hazardous gases in a long tunnel located in urban area haute been predicted theoretically. The results are compared with design criteria. It is found that the maximum concentrations of both CO and $NO_X$ in the tunnel are lower than the design criteria. However, the maximum extinction coefficient, generally considered to be a governing factor for ventilating flow rate, is shown lower than the design criterion. Therefore, it is suggested that the design criterion of the extinction coefficient should be increased to a slightly larger value.

Adsorption Characteristics of Al (III), Ni (II), Sm (III) Ions on Resin with Styrene Hazardous Material in Reinforcement Water Fire Extinguishing Agent

  • Kim, Joon-Tae
    • Journal of Integrative Natural Science
    • /
    • v.6 no.3
    • /
    • pp.151-157
    • /
    • 2013
  • The ion exchange resins were synthesized from 1-aza-18-crown-6 macrocyclic ligand attached to styrene (2th petroleum in 4th class hazardous material) divinylbenzene (DVB) copolymer with crosslinks of 1%, 6%, and 15% by substitution reaction. These synthetic resins were confirmed by chlorine content, elementary analysis, surface area, and IR-spectrum. The object of this study was to seperate the metal ion absorbed in reinforcement water fire extinguishing agent. As the results of the effects of pH, equilibrium arrival time, and crosslink of synthetic resin on metal ion adsorption for resin adsorbent, the metal ions were showed high adsorption at pH 3 or over and adsorption equilibrium of metal ions was about 2 hours. In addition, adsorption selectivity for the resin in water was the order of Al (III) > Ni (II) > Sm (III) ions, adsorbability of the metal ions was in the crosslinks order of 1%, 6%, and 15%.

Adsorption of Rare Earth Metal Ion on N-Phenylaza-15-Crown-5 Synthetic Resin with Styrene Hazardous Material

  • Kim, Se-Bong;Kim, Joon-Tae
    • Journal of Integrative Natural Science
    • /
    • v.7 no.2
    • /
    • pp.130-137
    • /
    • 2014
  • Resins were synthesized by mixing N-phenylaza-15-crown-5 macrocyclic ligand attached to styrene (2th petroleum in 4th class hazardous materials) divinylbenzene (DVB) copolymer with crosslink of 1%, 2%, 6%, and 12% by substitution reaction. The synthesis of these resins was confirmed by content of chlorine, element analysis, thermo gravimetric analysis (TGA), surface area, and IR-spectroscopy. The effects of pH, equilibrium arrival time, dielectric constant of solvent and crosslink on adsorption of metal ions by the synthetic resin adsorbent were investigated. The metal ions were showed fast adsorption on the resins above pH 4. The optimum equilibrium time for adsorption of metallic ions was about two hours. The adsorption selectivity determined in ethanol was in increasing order uranium (VI) > zinc (II) > europium (III) ions. The uranium ion adsorbed in the order of 1%, 2%, 6%, and 12% crosslink resin and adsorption of resin decreased in proportion to the order of dielectric constant of solvents.

Applying a GIS to Solid and Hazardous Waste Disposal Site Selection (쓰레기매립장 부지선정을 위한 GIS 활용연구)

  • 김윤종;김원영;유일현;백종학;이현우;류중희
    • Korean Journal of Remote Sensing
    • /
    • v.6 no.2
    • /
    • pp.135-151
    • /
    • 1990
  • Solid and hazardous waste disposal site selection by using GIS(Geographic Information System) is the purpose of this study. The criteria of site selection are usually defined in accordance with geological, cultural and social characteristics. Unadequate adaptation of these criteria in a site selection may cause serious problem of water and soil pollution. The environmental information for extraction of these criteria consist of a lot of data : geology, geomorphology, hydrogeology, engineering geology, cultural and social information.... GIS could be easily applied to construct of this environmental information data base, and carry out cartography simulation using overlay mapping technique(polygon overlay). ARC/INFO(GIS system) was used for these studies, and AML(ARC/INFO Macro Language) in this system provided more variable and effective methods for cartography simulation. TM(Thematic Mapper) images were used for the evaluation of land cover/use in the studied area, by using ERDAS image processing system.

Exposure Assessment Study on Lithium-Ion Battery Fire in Explosion Test Room in Battery Testing Facility

  • Mi Sung Jo;Hoi Pin Kim;Boo Wook Kim;Richard C. Pleus;Elaine M. Faustman;Il Je Yu
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.114-117
    • /
    • 2024
  • A lithium-ion battery is a rechargeable battery that uses the reversible reduction of lithium ions to store energy and is the predominant battery type in many industrial and consumer electronics. The lithium-ion batteries are essential to ensure they operate safely. We conducted an exposure assessment five days after a fire in a battery-testing facility. We assessed some of the potentially hazardous materials after a lithium-ion battery fire.We sampled total suspended particles, hydrogen fluoride, and lithium with real-time monitoring of particulate matter (PM) 1, 2.5, and 10 micrometers (㎛). The area sampling results indicated that primary potential hazardous materials such as dust, hydrogen fluoride, and lithium were below the recommended limits suggested by the Korean Ministry of Labor and the American Conference of Governmental Industrial Hygienists Threshold Limit Values. Based on our assessment, workers were allowed to return to work.

Improvement of Marine Environmental Impact Assessment for Golf Course Projects in Southern Coastal Area of Korea (남해연안 골프장조성에 따른 해양환경영향평가 개선방안)

  • Kim, Gui-Young;Lee, Dae-In;Yu, Jun;Eom, Ki-Hyuk;Jeon, Kyeong-Am
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.5
    • /
    • pp.453-464
    • /
    • 2010
  • We evaluated the status and problems of golf course developments in the southern coast of Korea. It's adjacent waters supports nursery and fishing grounds for commercially-important fisheries species, and various sites are designated and protected as marine protection area(MPA), fisheries reserve, or clean area(blue belt) for producing shellfish. We proposed key assessment items for environmental impact assessment(EIA) and checklists in selecting golf course locations. For the protected areas, we suggest that it is essential to limit golf course establishment while setting a minimal distance from the coast to secure a buffer zone for mitigating the environmental impacts. To efficiently utilize existing regional coastal management plans, it is necessary to diagnose how a golf course development will potentially modify geomorphology and scenery, amplify pollutant loads from non-point sources, and disrupt the functions of coastal ecosystem. Especially, continued monitoring and assesssing input loads of hazardous materials originating from agricultural chemicals should be obligatory. Finally, measures for improving the QA/QC analysis were discussed to enhance reliability of environmental data with respect to golf courses and adjacent coastal waters.

Exposure Assessment of PCDD/Fs and Monitoring of Health Effects on Workers and Resident near the Waste Incinerators in Korea (국내 일부 소각장 근로자와 주변지역주민들의 PCDDs/Fs 노출과 건강 영향 평가)

  • Hong, Yun-Chul;Lee, Kwan-Hee;Kwon, Ho-Jang;Jang, Jae-Yeon;Leem, Jong-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.4
    • /
    • pp.314-322
    • /
    • 2003
  • Objectives : In this study, the exposure status of the hazardous substances from incinerators, such as polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), were studied , and the relationship between the exposure of these hazardous substances and their heath effects on the workers and residents near municipal solid waste (MSW) incinerators and an industrial incinerator investigated. Methods : Between July 2001 and Jure 2002, 13 workers at two MSW incinerators, 16 residents from the area around the two MSW incinerators, 6 residents from the control area, and further 10 residents near an industrial incinerator, estimated to emit higher levels of hazardous substances, were interviewed. Information, including sociodemographic information, personal habits, and work history, detailed gynecologic and other medical history were collected through interviews. Blood samples were also collected from 45 subjects, and analyzed for PCDD/DFs, by high resolution gas chromatography -high resolution mass spectrometry, using the US EPA 1613 method. In addition to the questionnaire survey, urinary concentrations of 8-hydroxydeoxyguanosine (8-OH-dG) and malondialdehyde (MDA) were measured as oxidative injury biomarkers. The urinary concentrations of 8-OH-dG were determined by in vitro ELISA, and the MDA by HPLC, using u adduct with thiobarbituric acid. Results : The PCDD/DFs concentrations in the residents near the industrial incinerator were higher than those in the controls, workers and residents near the MSW incinerators. The average TEQ (Toxic Equivalencies) concentrations of the PCDD/DFs in residents near the industrial incinerator were 53.4pg I-TEQs/g lipid. The estimated daily intakes were within the tolerable daily intake range (1-4 pg I-TEQ/Kg bw/day) suggested by WHO (1997) in only 30% to the people near the industrial incinerator. Animal studies have already shown that even a low body border of PCDD/DFs, such as 10 ng TEQ/kg bw, can cause oxidative damage in laboratory animals. Our study also showed that the same body burden of PCDD/DFs can cause oxidative damage to humans. Conclusions : The exposures to PCDD/DFs and the oxidative stress of residents near the industrial incinerator, were higher than those in the controls, workers and residents near the MSW incinerators. Proper protection strategies against these hazardous chemicals are needed. Because a lower body burden of PCDD/Fs, such as 10ng TEQ/kg bw, can cause oxidative damage, the tolerable daily intake range should be restrictedly limited to 1pg I-TEQ/kg bw/day.

Exposure Assessment of Hazardous gases in Confined Spaces (밀폐공간 종류별 유해가스 발생 농도 평가)

  • Park, Hyunhee;Yoo, Kye-mook;Ham, Seung-hon;Chung, Kwang-Jae;Shin, Min-a;Lee, Koo-yong;Jang, Kyung-jo;Yoon, Chung-sik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.4
    • /
    • pp.381-389
    • /
    • 2009
  • Confined spaces are inherently dangerous workplace and many fatal and nonfatal accidents have been reported. Even though these accidents occur in various kinds of confined spaces, there has rarely been reported on the health hazard agent, i.e., the types of gases and their concentration ranges. Therefore in this study, we evaluated several toxic and asphyxiating gas concentrations in various confined spaces. We surveyed 57 manholes, 3 sewage treatment plants, 2 yellow radish manufacturing companies and 7 barges to measure the concentrations of oxygen($O_2$), hydrogen sulfide($H_2S$), carbon monoxide(CO), ammonia($NH_3$). Lower Explosion Limits(LEL) and Volatile Organic Compounds (VOCs). Those four types of confined spaces occupies 56% of accidents during last 9 years in Korea. In 57 manholes, the concentration varied according to the types of manholes; rainfall and sewage, and by location; residential and industrial areas. Sewage manhole in industrial area was evaluated as the most hazardous than other types of manhole like rainfall manholes, residential sewage manholes. The highest $H_2S$ concentration and the lowest $O_2$ concentration at sewage manhole in industrial area were 300 ppm, 8.7% respectively. In 3 sewage treatment plants, $H_2S$ and $NH_3$ concentrations were reached up to the 500 ppm and 200 ppm respectively. Two yellow radish manufacturing companies showed the concentrations of 316 ppm, 505.2 ppm, 90 ppm and 15.7% for $H_2S$, CO, VOCs and $O_2$, respectively. Seven barges showed 15.9%~20.9% oxygen concentration. Gas species and concentration ranges varied by the types and location of confined spaces; CO, $H_2S$, $O_2$ could be hazardous in manhole, especially manhole connected to sewage plants. CO, $H_2S$, LEL, $O_2$, $NH_3$ should be controlled in sludge silo and sluge pumping confined spaces in sewage treatment plant. The activity of lifting out radish from the storage tank was evaluated more hazardous rather than the other activities in yellow radish manufacturing industry. The employers must conduct the survey to identify all possible confined spaces in their local workplace prior to performing the tasks. At the national level to reduce the accidents in the confined spaces, we suggest that systemic approach and active education program including possible hazards, standard operation procedures, ventilation plan, and personal protective equipment in confined spaces should be implemented.