• Title/Summary/Keyword: Harmonic simulation

Search Result 977, Processing Time 0.028 seconds

Harmonic and Torque Ripple Reduction of Electric Propulsion System using 12-Pulse Diode Rectifier by Auxiliary Supply (보조 전원을 이용한 12 펄스 다이오드 정류기를 사용하는 추진시스템의 고조파 및 토크 리플 저감)

  • Kim, Jong-Su;Seo, Dong-Hoan;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.1
    • /
    • pp.66-70
    • /
    • 2013
  • The input current of three phase rectifier which is mainly used in the propulsion system of the electric propulsion ship includes a variety of low order harmonics. To reduce these harmonics, the power conversion system, used in the large vessels which high power is required, is currently used the rectifiers of 12-pulse output, but it still has a problem that occurs $12{\pm}1$ harmonics. Also, in the case of the direct torque control technique which is widely used for the speed and torque control, the torque ripple is severe and the input current of motor has greatly included harmonics by the switching of the inverter. In order to reduce harmonics and improve the performance of torque control, this paper presents that the auxiliary supply assisted into the 12-pulse rectifier of the electric propulsion system using direct torque control technique. We confirm the validity of the proposed method through the simulation under the environment of a real vessel system.

The Characteristics of Tidal Residual Current in Youngil Bay (영일만의 조석잔차류 거동 특성)

  • Kim Jong-Kyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.1
    • /
    • pp.14-23
    • /
    • 2001
  • The characteristics of tidal circulation with Hyungsan River discharges in Youngil Bay by the numerical experiments is elucidated. For the simulation of tidal residual currents related to inflow by the river discharges in Youngil Bay located in the southeastern part of Korean Peninsula, the two-dimensional numerical experiment is peformed. The tidal elevation boundary conditions of the 4 main tidal harmonic constituents (M₂, S₂, K₁ and O₁) on the open boundary and river discharges at the river boundary are considered. The computed results obtained from numerical experiment showed good agreements with the field observation ones. The residual currents generally flow toward the inner bay through the western (Dalman-Gap) and central areas of the bay, and then the currents go toward the outer bay along the eastern shore (Changgi-Gap) of the bay with anti-clockwise circulation. Especially, in the numerical experiment without Hyungsan River discharges, these flow patterns are disappeared. Based on the results, it showed that the Hyungsan River discharges play the dominant role in the patterns of tidal residual currents. This flow pattern of tidal residual currents are important mechanism of water quality, material transport in Youngil Bay.

  • PDF

Design and Fabrication of 5.5 GHz VCO for DSRC (근거리 무선통신용 5.5 GHz 대역 VCO 설계 및 제작)

  • 한상철;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.3
    • /
    • pp.401-408
    • /
    • 2001
  • This paper shows the design, fabrication and performance analysis of VCO which plays a major role in 5.8 GHz RF module for ITS. The design specifications of the VCO are determined on the basis of 5.8 GHz RF modul performance requirements. The design parameters are optimized through ADS simulation tool. The operating characteristic and performance analysis of the implemented VCO based on the design parameters are accomplished. The frequency variations according to the voltage change(0 ~5 V) of varactor diode are from 5.42 GHz to 5.518 GHz and the power level is 6.5 dBm. The second harmonic suppression are -21.5 dBc at 5.51 GHz and the phase noise characteristics are -83.81 dBc at 10 kHz offset frequency. The implemented VCO is available to not only DSRC and also, 5.8 GHz other systems.

  • PDF

Development of a Linear Power Amplifier Module for PCS Handy Phone (휴대용 PCS 단말기를 위한 선형 전력증폭기 모듈의 구현)

  • 노태문;한기천;김영식;박위상;김범만
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.6
    • /
    • pp.558-567
    • /
    • 1997
  • Linear power amplifier modules with high-efficiency have been developed for PCS handy phone. These modules were designed using extracted large-signal models of MESFETs and harmonic balance simulation. The modules are intended for low-tier and high-tier at the operation frequency range of 1750 ~ 1780 MHz. For low-tier module, the output power and $IMD_3$ were 23.2 dBm and 31 dBc, respectively, at power-added efficiency of 34% with the supply drain bias of 3.6 V. For high-tier module, the output power and $IMD_3$ were 272.2 dBm and 31 dBc, respectively, at power-added efficiency of 33% with the supply drain bias of 4.2 V. These linear power amplifier modules are suitable for PCS handy phone.

  • PDF

A study on analysis of DVR(Dynamic Voltage Restorer) in electric traction network by using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 전기철도급전계통에 DVR(Dynamic Voltage Restorer)해석에 관한 연구)

  • Choi, J.H.;Kim, J.C.;Park, S.M.;Kim, T.S.;Choo, D.W.;Chung, I.Y.;Park, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.283-286
    • /
    • 2003
  • The electric traction load is quite differ from general power system load which is single-phase, high-speed heavy load receiving power from 3-phase power system and also has variable load characteristics over time and space. Therefore, there are inevitably power quality problems such as steady state or transient voltage drop, voltage imbalance and harmonic distortion. In addition, it is expected that transient voltage sag could affect the safety of feeding system. Thus, in this paper transient analysis and voltage sag compensation of AT(Auto Transformer) feeding system are studied. The fault study of traction network is analysed by using PSCAD/SMTDC simulation tool. In addition, application of DVR in electric traction system is proposed to compensate the voltage sag of traction network which is occurred by the fault of utility source. The results of fault study will be a useful research works for operation and setting of electric traction relay. Also, it can be shown that application of the DVR in electric system is very useful to compensate the voltage sag from the result of related simulated work. The results of study will be a useful research works for management and planning of power quality in electric traction system.

  • PDF

Jeju 80kV HVDC Controller Modeling Using PSCAD/EMTDC Program (PSCAD/EMTDC 프로그램을 이용한 제주 80kV HVDC 제어기 모델링)

  • Choi, Soon-Ho;Lee, Seong-Doo;Kim, Chan-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.533-541
    • /
    • 2011
  • This paper studies modeling of Jeju 80kV HVDC system and its controller by using PSCAD/EMTDC program. Reduced ac network is applied to verify interaction between ac network and dc system. Design parameter is applied to the converter transformer, harmonic filter and dc transmisstion line to simulate dc system. HVDC controller is divided into a rectifier controller and a inverter controller according to the converter operating mode. The inverter controller is composed of current control, voltage control and extingtion angle control. The rectifier controller is composed of current control and voltage control. Both controller has VDCOL characteristics so that current order is dependant on voltage variation. Step response, ac network single phase fault, three phase fault is simulated to verify the dynamic performance of controller model in both transient state and steady state.

Evaluation of Wind-Induced Vibration for Multiple Stacks Using Numerical Analysis (전산 해석을 이용한 다중연돌의 유체유발진동)

  • Yang, Kwangheok;Park, Chaegwan;Kim, Hyeonjoon;Baek, Songyoul;Park, Soontae
    • Plant Journal
    • /
    • v.12 no.3
    • /
    • pp.24-31
    • /
    • 2016
  • Wind-induced vibration is a phenomenon that a struture is oscillated due to wind force such as buffeting, vortex shedding wake and etc., which is one of important characteristics to be considered for design in case that stack has significant slenderness ratio or low natural frequency. International design standards of stack define several criteria for evaluating the suitability of stack design, which describe the required design considerations for each range of design parameters and provide the instruction to verify the stack design against wind-induced vibration simply. However, there is a limitation that they cannot provide quantitative information in case code requirement cannot be satisfied due to constraints of plant space or economical design. In order to overcome the limiation of code, integrated numerical analysis of computational fluid dynamics, harmonic analysis and finite element analysis were proposed to investigate wind-induced vibration for multiple stacks in actual plant. Simulated results of mutual wake interference effect between adjacent stacks were evaluated and compared to the criteria in international standards.

  • PDF

Computer Simulation on the Poling Mechanism for the Control of 2nd Order Optical Nonlinearity in Silica Glass (2차 비선형 광특성의 제어를 위한 실리카 유리의 전기분극 기구 전산모사)

  • Yu, Ung-Hyeon;Lee, Seung-Gyu;Sin, Dong-Uk;Jeong, Yong-Jae
    • Korean Journal of Materials Research
    • /
    • v.11 no.3
    • /
    • pp.207-214
    • /
    • 2001
  • Silica glass is a core material for optical fiber in optical telecommunications, but its centrosymmetry eliminates the second order nonlinearity. But it is experimentally well known that the space charge polarization induces the Second Harmonic Generation (SHG) when a strong DC voltage is applied to silica glass for a long period of time with metal blocking electrodes. In this report, the results of a theoretical calculation of the nonlinear optical property caused by the space charge polarization, and a model of a numerical analysis to predict the small chance in nonlinear optical property as functions of time and space are provided. Assuming that amorphous silica is a solid state electrolyte and sodium ion is the only mobile charge carrier, 'Finite Difference Method' was employed for modeling of numerical analysis. The distributions of the concentration of sodium ion and electric field as functions of a normalized length of the specimen and a normalized applied voltage were simulated.

  • PDF

Coplanar Waveguide Bandpass Filter Using the Folded-line Stepped- Impedance Restorator (접힌 스텝 임피던스 공진기를 이용한 CPW 대역 통과 여파기)

  • 이진택;이창언;신철재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.8A
    • /
    • pp.620-625
    • /
    • 2003
  • The coplanar waveguide bandpass filter using folded-line stepped-impedance resonators(SIRs) is proposed. The folded-line SIR has about λ/8 length using the short-circuited end on coplanar waveguide. It make that the bandpass filter has the half size in comparison with general λ/4 SIR filter. In this paper, we derive the equivalent circuit and design the bandpass filter by using that. We design and fabricate the bandpass filter which has 5 GHz center frequency and 3 % fractional bandwidth. The measurement results fur 4-pole folded SIR bandpass filter agreed well with full-wave simulation and equivalent circuit results. The fabricated bandpass filter has a good spurious characteristic, which the harmonic frequency appeared at 2.5f$\_$0/). The proposed folded-line SIR bandpass filter are applicable for MMIC and High-Tc superconducting filters. bandwidth.

A Study on the Improvement of Efficiency and Linearity of Power Amplifier using PBG Structure (PBG 구조를 이용한 전력 증폭기의 효율 및 선형성 개선에 관한 연구)

  • 김병희;박천석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1182-1190
    • /
    • 2001
  • In this paper, microstrip photonic bandgap (PBG) structure with special perforation patterns etched on the line itself is analyzed and optimized in shape, then used for harmonic tuning of power amplifier. This PBG has an advantage in being fabricated and grounded. The dimension of unit lattice is enlarged vertically, but its input and output line maintain 50 Ω using tapered line. This modification from original structure can lessen possible error in etching PCB. The analysis and design of PBG structure are acquired from using EM simulation. The measured insertion loss of the final structure is 0.3 ∼0.4 dB, and its bandwidth of stopband is 6∼7 GHz. Measured results of improved characteristics by using PBG structure at the output of the power amplifier are 0.72∼0.99 dB in output power, 1.14∼7.8 % in PAE, and 1 dBc in the third IMD.

  • PDF