• 제목/요약/키워드: Harmonic injection method

검색결과 55건 처리시간 0.033초

능동형 교류 전력 필터에 의한 고조파 보상전류의 새로운 주입방식 (A New Injection Method of Harmonic Compensation Current by Active AC Power Filter)

  • 박민호;최규하
    • 대한전기학회논문지
    • /
    • 제34권9호
    • /
    • pp.361-367
    • /
    • 1985
  • A new injection method is proposed for active power filters to eliminate AC harmonics in ac input current of nonlinear loads such as rectifiers. By injecting the PWM current determined by the proposed injection method, all the harmonics up to order nn can be eliminated to exactly zero. This PWM injection current can be generated by sampling total harmonic wave at the rate of M and the sampled values are converted into the proposed PWM wave with N pulse-width variables and adjustable current magnitude Im. These variables are deetermined by solving a set of N nonlinear harmonic equations and the harmonic-elimination characteristics of the new injection are investigated through digital computer sinmulation. Also by comparing between the simulated results and the ones synthesized by data stored in EPROM, the possibility of the suggested injection method can be shown.

  • PDF

밀리미터파 대역 제2고조파 출력 발진기의 주입동기 특성 (Injection Locked Synchronization Characteristics of a Millimeter Wave Second Harmonic Oscillator)

  • 최영규
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1700-1705
    • /
    • 2013
  • A second harmonic millimeter wave oscillator utilizing sub-harmonic injection-synchronization is presented. A 8.7GHz oscillator with MES-FET is designed, and is driven as a harmonic output oscillator at 17.4GHz by means of sub-harmonic injection-synchronization. The oscillator operates as a multiplier as well as a oscillator in this scheme. Adopting this method, a high sable, high frequency millimeter wave source is obtainable even though self-oscillating frequency of an oscillator is relatively low. The range of injection-synchronization is about 26MHz, and is proportional to the input sub-harmonic power. The spectrum analysis of the 2nd harmonic output frequency shows remarkably decreased the phase noise level.

Parameters On-line Identification of Dual Three Phase Induction Motor by Voltage Vector Injection in Harmonic Subspace

  • Sheng, Shuang;Lu, Haifeng;Qu, Wenlong;Guo, Ruijie;Yang, Jinlei
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권3호
    • /
    • pp.288-294
    • /
    • 2013
  • This paper introduces a novel method of on-line identifying the stator resistance and leakage inductance of dual three phase induction motor (DTPIM). According to the machine mathematical model, the stator resistance and leakage inductance can be estimated using the voltage and current values in harmonic subspace. Thus a method of voltage vector injection in harmonic subspace (VVIHS) is proposed, which causes currents in harmonic space. Then the errors between command and actual harmonic currents are utilized to regulate the machine parameters, including stator resistance and leakage inductance. The principle is presented and analyzed in detail. Experimental results prove the feasibility and validity of proposed method.

고조파 주입법에 의한 3상 부스트 정류기의 고조파 저감 (Harmonic Reduction of a Single-Switch Three-Phase Boost Rectifier using Harmonic-Injection Method)

  • 이준구;박석하;김진성;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.134-136
    • /
    • 1998
  • In this paper, we present harmonic reduction of a Single-Switch Three-Phase Boost Rectifier which is operated at 25kHz. A simulation result shows that input current harmonics of Single-Switch Three-Phase Rectifier are reduced by Harmonic-Injection Method. Sixth harmonic is used for Harmonic-Injection Method.

  • PDF

전류주입식 능동전력 필터를 위한 최적주입방법의 해석 (Analysis of Optimized Injection Method for Active Power Filter of Current Injection Type)

  • 박민호;최규하
    • 대한전기학회논문지
    • /
    • 제35권7호
    • /
    • pp.296-303
    • /
    • 1986
  • The active filter of current injection type is the device which eliminates the harmonics in ac line by injecting the harmonic compensating current into the ac side. And its harmonic reduction performance is entirely dependent on the control scheme of the current-fed inverter and the harmonic compensating current becomes the PWM wave by the inverter. This PWM compensating current can be determined by selecting the switching function properly which eliminates the harmonics up to any order with using no independent sources. The new injection current model is derived by the proposed method which is called the optimized injection method. The overall characteristics of the proposed method are investigated through digital computation and the feasibility is proved with experimental results obtained from the Z-80 microcomputer control of the active filter.

  • PDF

Islanding Prevention Method for Photovoltaic System by Harmonic Injection Synchronized with Exciting Current Harmonics of Pole Transformer

  • Yoshida, Yoshiaki;Fujiwara, Koji;Ishihara, Yoshiyuki;Suzuki, Hirokazu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권3호
    • /
    • pp.331-338
    • /
    • 2014
  • When large penetration of the distributed generators (DGs) such as photovoltaic (PV) systems is growing up in grid system, it is important to quickly prevent islanding caused by power system fault to ensure electrical safety. We propose a novel active method for islanding prevention by harmonic injection synchronized with the exciting current harmonics of the pole transformer to avoid mutual interference between active signals. We confirm the validity of the proposed method by performing the basic tests of islanding by using a current source superimposed the harmonic active signal. Further, we carry out the simulation using PSCAD/EMTDC, and verify the fast islanding detection.

Islanding Detection Method for Inverter-Based Distributed Generation through Injection of Second Order Harmonic Current

  • Lee, Yoon-Seok;Yang, Won-Mo;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1513-1522
    • /
    • 2018
  • This paper proposes a new islanding detection method for inverter-based distributed generators by continuously injecting a negligible amount of 2nd order harmonic current. The proposed method adopts a proportional resonant (PR) controller for the output current control of the inverter, and a PR filter to extract the 2nd order harmonic voltage at the point of common coupling (PCC). The islanding state can be detected by measuring the magnitude ratio of the 2nd order harmonic voltage to the fundamental voltage at the PCC by injecting a 2nd order harmonic current with a 0.8% magnitude. The proposed method provides accurate and fast detection under grid voltage unbalance and load unbalance. The operation of the proposed method has been verified through simulations and experiments with a 5kW hardware set-up, considering the islanding test circuit suggested in UL1741.

전력계통 고조파 유입 유출 분석에 관한 연구 (A Study on the Analysis of Harmonic Injection and Emission for Power System)

  • 왕용필;정종원;김세동;곽노홍;전영수;박상호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.203-205
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF

Cascaded NPC/H-bridge 컨버터의 DC링크 리플 저감을 위한 3차 고조파 주입 기법 (DC-link Ripple Reduction of Cascaded NPC/H-bridge Converter using Third Harmonic Injection)

  • 박우호;강진욱;현승욱;홍석진;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.218-219
    • /
    • 2016
  • This paper present Phase Shifted with carrier based on Sinusoidal PWM(SPWM) by using Cascaded NPC/H-birdge converter. The proposed Phase Shifted PWM method is adding third harmonic injection in switching signal. The advantage of the proposed method is reducing the voltage and capacity of the capacitor. This paper compare general Phase Shifted method with proposed Phase Shifted method that added the third harmonic injection. Each PWM method is tested without considering the switching loss by using PSIM 9.1.4 simulation.

  • PDF

새로운 영상전류 주입법에 의한 다이오드 정류기의 고조파 저감 (Harmonic Reduction of Diode Rectifiers by a New Zero-Sequence Current Injection Method)

  • 김현정;장민수;최세완;원충연;김규식
    • 전력전자학회논문지
    • /
    • 제7권6호
    • /
    • pp.596-603
    • /
    • 2002
  • 본 논문에서는 영상고조파 주입법을 사용하여 3상 다이오드 정류기의 입력전류를 개선하는 새로운 방식의 고조파 저감기술을 제안한다. 3고조파 주입을 근간으로 하는 본 방식은 다이오드 정류기의 상측과 하측의 전류를 독립적으로 제어하기 위하여 두 대의 단상 반파 인버터와 두 대의 단상 변압기로 구성되어져 있다. 이렇게 만들어진 영상전류는 zigzag 변압기에 의해서 다이오드 정류기의 상측과 하측으로 주입이 되어진다. 이 결과 3상 다이오드 정류기의 입력전류는 순수한 정현파 전류가 된다. 본 방식의 타당성을 1.5kVA 시작품의 실험을 통하여 입증하였다.