• 제목/요약/키워드: Harmonic Tuning

검색결과 84건 처리시간 0.027초

근접장 광학계의 광학적 및 기계적 특성 분석과 근접장 간격제어 (Optical and Mechanical Characteristics of NF System and NF Gap Control)

  • 오형렬;이준희;권대갑;김수경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1528-1532
    • /
    • 2000
  • The conventional optics and near field optics are compared numerically in the view points of the spot size and propagation characteristics. The decaying characteristics of near field light require the optics to access the object within several tens of nanometers. Therefore the gap control is one of the main issues in the near field optics area. In this paper the gap control is done by using the shear force of the NF(Near Field) probe and the characteristics are examined. The probe is modeled as a 2'nd order mass-spring-damper system driven by a harmonic force. The primary cause of the decrease in vibration amplitude is due to the damping force - shear force - between the surface and the probe. Using the model, damping constant and resonance frequency of the probe is calculated as a function of probe-sample distance. Detecting the amplitude and phase shift of the NF probe attached to the high Q-factor piezoelectric tuning fork, we can control the position of the NF probe about 0 to 50nm above the sample. The feedback signal to regulate the probe-sample distance can be used independently for surface topography imaging. 3-D view of the shear force image of a testing sample with the period of $1{\mu}m$ will be shown.

  • PDF

A study on vibration characteristics and tuning of smart cantilevered beams featuring an electo-rheological fulid

  • Park, S.B.;Cheong, C.C.;Suh, M.S.
    • 한국정밀공학회지
    • /
    • 제10권1호
    • /
    • pp.134-141
    • /
    • 1993
  • Electro-Rheological(ER) fluids undergo a phase-change when subjected to an external electic field, and this phase-change typically manifests itself as a many-order-of-magnitude change in the rheological behavior. This phenomenon permits the global stiffness and energy- dissipation properties of the beam structures to be tuned in order to synthesize the desired vibration characteristics. This paper reports on a proof-of-concept experimental investigation focussed on evaluation the vibration properties of hollow cantilevered beams filled with an ER fluid. and consequently deriving an empirical model for predicting field-dependent vibration characteristics. A hydrous-based ER fluid consisting of corn starch and silicone oil is employed. The beams are considered to be uniform viscoelastic materials and modelled as a viscously-damped harmonic oscillator. Natural frequency, damping ratio and elastic modulus are evaluated with respect to the electric field and compared among three different beams: two types of different volume fraction of ER fluid and one type of different particle concentration of ER fluid by weight. Transient and forced vibration responses are examined in time domain to demonstrate the validity of the proposed empirical model and to evaluate the feasibility of using the ERfluid as an actuator in a closed-loop control system.

  • PDF

능동 집적 안테나에 관한 연구 (A Study on the Active Integrated Antenna)

  • 이병무;윤영중
    • 한국전자파학회논문지
    • /
    • 제13권1호
    • /
    • pp.19-25
    • /
    • 2002
  • 본 논문에서는 전력증폭기를 슬롯이 적재된 삼각형 마이크로스트립 패치 안테나와 동일 평면의 기판에 집적화하여 전력증폭기 출력단의 제 3 고조파 튜닝을 안테나가 수행함으로써 전력효율을 향상시키는 효과와, 실제 집적화에 따른 송.수신 신호의 분리 문제를 위해 이중공진, 이중급전을 이용한 능동 집적 안테나의 특성을 고찰하였다. 제 3 고조파에서 방사를 억제 구조로서 안테나에 슬롯을 적재시킨 능동 집적 안테나를 설계, 제작하여 측정한 결과, B급 전력증폭기와 안테나를 각각 제작하여 결합한 형태보다 약 5 %의 전력효율 개선 효과를 얻을 수 있었다. 또한, 송.수신 분리에 대하여서도 IMT-2000주파수 대역의 수신 port에서 송신 주파수의 신호를 -35 dB 이하로 격리시키는 특성을 나타냄을 관찰할 수 있었다.

Studies on control mechanism and performance of a novel pneumatic-driven active dynamic vibration absorber

  • Kunjie Rong;Xinghua Li;Zheng Lu;Siyuan Wu
    • Structural Engineering and Mechanics
    • /
    • 제87권2호
    • /
    • pp.117-127
    • /
    • 2023
  • To efficiently attenuate seismic responses of a structure, a novel pneumatic-driven active dynamic vibration absorber (PD-ADVA) is proposed in this study. PD-ADVA aims to realize closed-loop control using a simple and intuitive control algorithm, which takes the structure velocity response as the input signal and then outputs an inverse control force to primary structure. The corresponding active control theory and phase control mechanism of the system are studied by numerical and theoretical methods, the system's control performance and amplitude-frequency characteristics under seismic excitations are explored. The capability of the proposed active control system to cope with frequency-varying random excitation is evaluated by comparing with the optimum tuning TMD. The analysis results show that the control algorithm of PD-ADVA ensures the control force always output to the structure in the opposite direction of the velocity response, indicating that the presented system does not produce a negative effect. The phase difference between the response of uncontrolled and controlled structures is zero, while the phase difference between the control force and the harmonic excitation is π, the theoretical and numerical results demonstrate that PD-ADVA always generates beneficial control effects. The PD-ADVA can effectively mitigate the structural seismic responses, and its control performance is insensitive to amplitude. Compared with the optimum tuning TMD, PD-ADVA has better control performance and higher system stability, and will not have negative effects under seismic wave excitations.

Design of a New Harmonic Noise Frequency Filtering Down-Converter in InGaP/GaAs HBT Process

  • Wang, Cong;Yoon, Jae-Ho;Kim, Nam-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제9권2호
    • /
    • pp.98-104
    • /
    • 2009
  • An InGaP/GaAs MMIC LC VCO designed with Harmonic Noise Frequency Filtering(HNFF) technique is presented. In this VCO, internal inductance is found to lower the phase noise, based on an analytic understanding of phase noise. This VCO directly drives the on-chip double balanced mixer to convert RF carrier to IF frequency through local oscillator. Furthermore, final power performance is improved by output amplifier. This paper presents the design for a 1.721 GHz enhanced LC VCO, high power double balance mixer, and output amplifier that have been designed to optimize low phase noise and high output power. The presented asymmetric inductance tank(AIT) VCO exhibited a phase noise of -133.96 dBc/Hz at 1 MHz offset and a tuning range from 1.46 GHz to 1.721 GHz. In measurement, on-chip down-converter shows a third-order input intercept point(IIP3) of 12.55 dBm, a third-order output intercept point(OIP3) of 21.45 dBm, an RF return loss of -31 dB, and an IF return loss of -26 dB. The RF-IF isolation is -57 dB. Also, a conversion gain is 8.9 dB through output amplifier. The total on-chip down-converter is implanted in 2.56${\times}$1.07 mm$^2$ of chip area.

First-order Generalized Integrator Based Frequency Locked Loop and Synchronization for Three-Phase Grid-connected Converters under Adverse Grid Conditions

  • Luo, Zhaoxu;Su, Mei;Sun, Yao;Liu, Zhangjie;Dong, Mi
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1939-1949
    • /
    • 2016
  • This paper presents an alternative frequency adaptive grid synchronization technique named HDN-FLL, which can accurately extract the fundamental positive- and negative-sequence components and interested harmonics in adverse three-phase grid voltage. The HDN-FLL is based on the harmonic decoupling network (HDN) consisting of multiple first order complex vector filters (FOCVF) with a frequency-locked loop (FLL), which makes the system frequency adaptive. The stability of the proposed FLL is strictly verified to be global asymptotically stable. In addition, the linearization and parameters tuning of the FLL is also discussed. The structure of the HDN has been widely used as a prefilter in grid synchronization techniques. However, the stability of the general HDN is seldom discussed. In this paper, the transfer function expression of the general HDN is deduced and its stability is verified by the root locus method. To show the advantages of the HDN-FLL, a simulation comparison with other gird synchronization methods is carried out. Experimental results verify the excellent performance of the proposed synchronization method.

마이크로스트립 종단형 CSRR구조를 이용한 X-band 레이다용 전압제어발진기의 설계 (Design of Voltage Controlled Oscillator for X-band Radar Using CSRR loaded microstrip line)

  • 김규철
    • 한국전자통신학회논문지
    • /
    • 제8권9호
    • /
    • pp.1277-1283
    • /
    • 2013
  • 본 논문에서는 마이크로스트립라인 종단형 CSRR구조를 이용하여 X-band 레이다에 사용하는 새로운 전압 제어 발진기를 제안하였다. 마이크로스트립 종단형 CSRR을 발진기와 버퍼 사이에 삽입되는 필터로 사용하여 고주파억압특성을 개선하였다. 측정 결과 제어전압을 0~10V로 가변 하였을 때 9.28~9.39GHz가 발진 하였으며 발진주파수 9.35GHz에서 16.6dBm의 높은 출력을 얻을 수 있었다. 또한 일반적인 발진기 보다 고주파억압 특성이 10.4dB 개선되었다.

음향공이 장착된 로켓엔진 연소실의 음향장 해석 (A Numerical Study on Acoustic Behavior in Combustion Chamber with Acoustic Cavity)

  • 손채훈;김영목
    • 한국항공우주학회지
    • /
    • 제30권4호
    • /
    • pp.28-37
    • /
    • 2002
  • 음향불안정을 억제하는 수동제어기구중 하나인 음향공의 음향학적 효과를 파악하기 위해, 음향공이 장착된 로켓엔진 연소실의 음향장 특성을 수치해석적으로 조사하였다. 음향공 모델로서 Helmholtz 형태의 공명기가 채택되었고, 조화해석을 통해 주로 음향공에 의해 야기되는 음향학적 효과를 관찰하였다. 음향공의 음속을 조정하여 동조주파수를 변화시켜가면서 가진음원에 대한 연소실의 음향진동 응답을 구하고, 제1접선방향 음향모드의 감쇠인자를 구하였다. 동조주파수가 제1접선방향 음향모드의 공진주파수에 접근함에 따라 모드분할 현상이 나타났고, 이로인해 음향공을 본래의 제1접선방향 음향모드에 동조시키더라도 음향감쇠효과가 저하됨을 알았다. 모드분할 현상과 분할된 각 모드의 감쇠인자 및 음향 에너지 분포를 고려하였으며, 이를 토대로 효과적인 감쇠를 위해서는, 억제하고자 하는 음향모드로부터 모드분할 현상이 나타나지 않으면서 그 음향모드의 감쇠효과를 극대화하도록 음향공을 동조시키는 것이 바람직함을 알 수 있었다.

Output Voltage Regulation for Harmonic Compensation under Islanded Mode of Microgrid

  • Lim, Kyungbae;Choi, Jaeho
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.464-475
    • /
    • 2017
  • This study examines a P+multi resonant-based voltage control for voltage harmonics compensation under the islanded mode of a microgrid. In islanded mode, the inverter is defined as a voltage source to supply the full local load demand without the connection to the grid. On the other hand, the output voltage waveform is distorted by the negative and zero sequence components and current harmonics due to the unbalanced and nonlinear loads. In this paper, the P+multi resonant controller is used to compensate for the voltage harmonics. The gain tuning method is assessed by the tendency analysis of the controller as the variation of gain. In addition, this study analyzes the slight voltage magnitude drop due to the practical form of the P+multi resonant and proposes a counter method to solve this problem by adding the PI-based voltage restoration method. The proposed P+multi resonant controller to compensate for the voltage harmonics is verified through the PSIM simulation and experimental results.

단일동조 수동고조파필터 설계시의 동조계수($\delta$) 및 양호도(Q) 값 연구 (Study on tuning factor($\delta$) and quality factor(Q) for design of a single-tuned PHF)

  • 조영식;차한주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.903_904
    • /
    • 2009
  • 본 논문에서는 대표적인 고조파 저감기법인 단일동조 수동고조파필터(single-tuned Passive Harmonic Filter)의 설계 시에 반드시 고려해야 할 최적의 동조계수($\delta$)와 양호도(Q)값의 결정 방법을 제안하였다. 두 값들은 실 사례를 통하여 결정하였고, 결정된 값들은 보드선도를 이용한 주파수 영역 해석을 수행한 후 최종적으로 이 값들을 반영하여 설계된 수동고조파필터의 성능확인을 통하여 본 논문에서 결정한 두 값들의 적합성을 평가하였다.

  • PDF