• 제목/요약/키워드: Harmonic Tuning

검색결과 84건 처리시간 0.021초

단일동조 수동고조파필터 설계시의 동조계수(δ) 및 양호도(Q)값 연구 (A Study on Tuning Factor(δ) and Quality Factor(Q) Values in Design of Single-Tuned Passive Harmonic Filters)

  • 조영식;차한주
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.64-70
    • /
    • 2010
  • This paper presents how to decide on tuning factor(${\delta}$) and quality factor(Q) values in design of single-tuned passive harmonic filters. Tuning factor(${\delta}$) and quality factor(Q) values have to consider before decision on circuit parameters of passive filters. A Study on these two value has not been scarcely performed and only experienced values has been used in passive harmonic filter design by far. As a experienced value, in cases of 5th and 7th filter, tuning factor(${\delta}$) is about 0.94 and 0.96 respectively and quality factor(Q) is, in all cases of, 50. If Single-tuned passive harmonic filter will be off-tuned, performance of filter will be decreased steeply and occur to parallel resonance between system reactance and filter capacitance. Therefore During the operation, In order not to off-tuning, Filter must be tuned at former order than actual tuning order. This is the same that total impedance of filter must have a reactive impedance. In this paper, Tuning factor(${\delta}$) is decided via example of real system and using the bode-plot and then performance of filters confirmed by filter current absorbtion rate. And Quality factor(Q) decided using the bode plot in example system and then performance of filters confirmed by filter current absorbtion rate also, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. Finally, Performance of the designed passive harmonic filter using the tuning factor(${\delta}$) and quality factor(Q) values, decided in this paper is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th current harmonic distortions are decreased within IEEE-519 distortion limits, respectively.

PSO를 이용한 계통연계형 인버터 전류제어기의 자동조정에 관한 연구 (A Study on Tuning of Current Controller for Grid-connected Inverter Using Particle Swarm Optimization)

  • 안종보;김원곤;황기현;박준호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.671-679
    • /
    • 2004
  • This paper presents the on-line current controller tuning method of grid-connected inverter using PSO(particle swarm optimization) technique for minimizing the harmonic current. Synchronous frame PI current regulator is commonly used in most distributed generation. However, due to the source voltage distortion, specially in weak AC power system, current may contain large harmonic components, which increase THD(total harmonic distortion) and deteriorates power quality. Therefore, some tuning method is necessary to improve response of current controller. This paper used the PSO technique to tune the current regulator and through simulation and experiments, usefulness of the tuning method has been verified. Especially in simulating the tuning process, ASM(average switching model) of inverter is used to shorten execution time.

Tuning range 개선을 위한 새로운 구조의 VCO 설계 및 제작 (Design and Implementation of the new structural VCO with improved tuning range)

  • 강동진;김동옥
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.293-297
    • /
    • 2009
  • In this thesis, design of a VCO(Voltage controlled Oscillator) with a novel tuning mechanism is presented for the Radar system. This circuit, the 9.5 GHz oscillator is designed and implemented by restructuring microstrip resonator to raise Q value and to require a wide frequency tuning range. This product is fabricated on 2.6 Teflon substrate and device is NE722S01. In this paper, The new microstrip resonator VCO is proposed to achieve the characteristic of a wide frequency tuning range. This microstrip resonator VCO shows the phase noise characteristic of -108.3 dBc/Hz at 1 MHz offset from the fundamental frequency, the output power of 5.7 dBm and the second harmonic suppression of -38 dBc for the VCO are obtained. The manufacture VCO shows a frequency tuning range of 193.8 MHz. The proposed micro trip resonator VCO can be used for X-band Radar System with required tuning range.

  • PDF

최적 부하 임피던스와 하모닉 튜닝을 이용한 B급 고효율 전력 증폭기의 설계 (Class-B high efficiency power amplifier by harmonic tuning iwth optimum load impedance)

  • 류정호;조영송;신철재
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.52-61
    • /
    • 1996
  • In this paper, harmonic-tuning method to achieve the maximum efficiency is proposed. Harmonic tuning method is applied to the optimum load impedance of a class B amplifier, which is extracted by using the modified cripps method. High efficiency power amplifier utilizing GaAs MESFET is designed and fabricated in the 835MHz band. The performance of th eamplifier is presented by having output power of 30.8dBm, drain efficiency of 80.5% and power added efficiency of 66% with an associated power gain of 7.4dB.

  • PDF

해도수준면(Chart Datum) 데이터베이스 제작 연구 (A Study on Making of Chart Datum Database)

  • 강용균;이문진
    • 한국해양학회지:바다
    • /
    • 제11권1호
    • /
    • pp.31-36
    • /
    • 2006
  • 해도상 수심으로부터 평균수심을 산정하기 위하여 검조소의 실측자료와 조석 수치모델링 결과를 결합하여 해도 수준기준면을 산정하는 방법을 연구하였다. 수준기준면은 4대분조($M_2$분조, $S_2$분조, $K_2$분조, $O_1$분조)의 진폭 합으로 결정되므로 검조소의 실측자료를 활용하여 산정할 수 있으나, 검조소의 자료는 연안에 한정되므로 해양의 수준기준면은 산정할 수 없다. 반면에 조석 수치모델링의 결과는 원하는 지점의 4대분조합을 도출할 수 있으나, 시뮬레이션 결과이므로 실제 수준기준면과는 차이를 보인다. 본 연구에서는 검조소 자료와 조석 수치모델링 결과를 상호보완하여 해양의 수준기준면을 보다 정확하게 산정할 수 있는 방법을 연구하였다 본 연구의 방법에서는 검조소의 자료와 조석 수치모델링 결과를 비교하여 보정계수를 추출하고, 각 검조소에 대한 보정계수를 내삽하여 대상해역의 임의지점에 대한 보정계수를 산정하여 조석 수치모델 결과에 적용함으로써 정확한 수준기준면을 산정한다.

Closed-form optimum tuning formulas for passive Tuned Mass Dampers under benchmark excitations

  • Salvi, Jonathan;Rizzi, Egidio
    • Smart Structures and Systems
    • /
    • 제17권2호
    • /
    • pp.231-256
    • /
    • 2016
  • This study concerns the derivation of optimum tuning formulas for a passive Tuned Mass Damper (TMD) device, for the case of benchmark ideal excitations acting on a single-degree-of-freedom (SDOF) damped primary structure. The free TMD parameters are tuned first through a non-linear gradient-based optimisation algorithm, for the case of harmonic or white noise excitations, acting either as force on the SDOF primary structure or as base acceleration. The achieved optimum TMD parameters are successively interpolated according to appropriate analytical fitting proposals, by non-linear least squares, in order to produce simple and effective TMD tuning formulas. In particular, two fitting models are presented. The main proposal is composed of a simple polynomial relationship, refined within the fitting process, and constitutes the optimum choice. A second model refers to proper modifications of literature formulas for the case of an undamped primary structure. The results in terms of final (interpolated) optimum TMD parameters and of device effectiveness in reducing the structural dynamic response are finally displayed and discussed in detail, showing the wide and ready-to-use validity of the proposed optimisation procedure and achieved tuning formulas. Several post-tuning trials have been carried out as well on SDOF and MDOF shear-type frame buildings, by confirming the effective benefit provided by the proposed optimum TMD.

혼합 우좌향 전송 선로 기반의 새로운 고조파 조절 회로를 이용한 저위상 잡음 전압 제어 발진기 (Low Phase Noise VCO Using Novel Harmonic Control Circuit Based on Composite Right/Left-Handed Transmission Line)

  • 최재원;서철헌
    • 대한전자공학회논문지TC
    • /
    • 제47권1호
    • /
    • pp.84-90
    • /
    • 2010
  • 본 논문에서는 주파수 조절 범위의 감소 없이 위상 잡음을 줄이고 회로 크기를 최소화하기 위하여 혼합 우좌향 전송 선로 기반의 고조파 조절 회로를 이용한 새로운 전압 제어 발진기를 제안하였다. 위상 잡음은 2차와 3차 고조파에서 동시에 단락임피던스를 갖는 새로운 고조파 조절 회로에 의해 줄어들었다. 제안된 고조파 조절 회로는 혼합 우좌향 전송 선로의 주파수 오프셋과 위상 기울기에 의한 이중 대역 특성을 갖는 혼합 우좌향 전송 선로를 이용하여 설계되었다. 높은 Q 특성의 공진기는 위상 잡음을 줄이기 위하여 사용되어 왔지만, 주파수 조절 범위가 감소하는 문제를 갖고 있다. 하지만 제안된 전압 제어 발진기의 주파수 조절 범위는 위상 잡음이 높은 Q 특성의 공진기 없이 감소하였기 때문에 줄어들지 않았다. 또한, 일반적인 우향 전송 선로 대신 혼합 우좌향 전송 선로를 이용하는 것을 통하여 회로의 크기를 소형화 하였다. 전압 제어 발진기의 위상 잡음은 5.731 ~ 5.938 GHz의 주파수 조절 범위 내에서 100 kHz의 오프셋 주파수에서 -119.17 ~ -117.50 dBc/Hz이다.

비 고주파동조 플라이백 트랜스포머에 관한 연구 (A Study on the Unharmonic-tuning Flyback Transformer)

  • 지철근;박지식
    • 대한전기학회논문지
    • /
    • 제35권12호
    • /
    • pp.586-593
    • /
    • 1986
  • Ringing during the scan time deteriorates the picture quality of television receiver. By tuning the stray reactance of the flyback transformer(FBT)to harmonics of the retrace pulse, the ringing can be suppressed and this is, what is called, the harmonic tuning methed. But finding the conditions for the ringing to cease in lossy FBT and satisfying these conditions at design stage require much time and experience. In this paper, the conditions for the ringing to cease in loss-included equivalent circuit are derived and a new method, unharmonic-tuning method, is suggested.

  • PDF

Class F 전력 증폭기의 드레인 전압 변화에 따른 고조파 조정 회로의 최적화 (Optimization of Harmonic Tuning Circuit vary as Drain Voltage of Class F Power Amplifier)

  • 이종민;서철헌
    • 대한전자공학회논문지TC
    • /
    • 제46권1호
    • /
    • pp.102-106
    • /
    • 2009
  • 본 논문은 EER(Envelope Elimination and Restoration)에 적용된 class F 전력 증폭기의 드레인 전압의 변화에 따른 출력 정합회로의 최적화에 대하여 연구하였다. EER 구조에 적용된 class F PA의 PAE(Power Added Efficiency)를 개선하기 위해 고조파 조정 회로에 Varactor 다이오드를 사용하였다. 포락선의 변화에 따라 2차 고조파는 단락 시키고 3차 고조파는 개방 시키도록 설계되었으며 본 논문에서 제안된 고조파 조정 회로를 통해 드레인 전압이 25 V에서 30 V까지 변화할 때 수 %의 PAE 개선 효과를 얻을 수 있었다.

Study of Harmonic Suppression of Ship Electric Propulsion Systems

  • Wang, Yifei;Yuan, Youxin;Chen, Jing
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1303-1314
    • /
    • 2019
  • This paper studies the harmonic characteristics of ship electric propulsion systems and their treatment methods. It also adopts effective measures to suppress and prevent ship power systems from affecting ship operation due to the serious damage caused by harmonics. Firstly, the harmonic characteristics of a ship electric propulsion system are reviewed and discussed. Secondly, aiming at problems such as resonant frequency and filter characteristics variations, resonance point migration, and unstable filtering performances in conventional passive filters, a method for fully tuning of a passive dynamic tunable filter (PDTF) is proposed to realize harmonic suppression. Thirdly, to address the problems of the uncontrollable inductance L of traditional air gap iron core reactors and the harmonics of power electronic impedance converters (PEICs), this paper proposes an electromagnetic coupling reactor with impedance transformation and harmonic suppression characteristics (ECRITHS), with the internal filter (IF) designed to suppress the harmonics generated by PEICs. The ECRITHS is characterized by both harmonic suppression and impedance change. Fourthly, the ECRITHS is investigated. This investigation includes the harmonic suppression characteristics and impedance transformation characteristics of the ECRITHS at the fundamental frequency, which shows the good performance of the ECRITHS. Simulation and experimental evaluations of the PDTF are carried out. Multiple PDTFs can be configured to realize multi-order simultaneous dynamic filtering, and can effectively eliminate the current harmonics of ship electric propulsion systems. This is done to reduce the total harmonic distortion (THD) of the supply currents to well below the 5% limit imposed by the IEEE-519 standard. The PDTF also can eliminate harmonic currents in different geographic places by using a low voltage distribution system. Finally, a detailed discussion is presented, with challenges and future implications discussed. The research results are intended to effectively eliminate the harmonics of ship electric power propulsion systems and to improve the power quality of ship power systems. This is of theoretical and practical significance for improving the power quality and power savings of ship power systems.