• 제목/요약/키워드: Harmonic Resonance

검색결과 258건 처리시간 0.034초

Impedance Matching Based Control for the Resonance Damping of Microgrids with Multiple Grid Connected Converters

  • Tan, Shulong;Geng, Hua;Yang, Geng
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2338-2349
    • /
    • 2016
  • This paper presents an impedance-matching-based control scheme for the harmonic resonance damping of multiple grid-connected-converters (GCCs) with LCL filters. As indicated in this paper, harmonic resonance occurs if a GCC possesses an output impedance that is not matched with the rest of the network in some specific frequency bands. It is also revealed that the resonance frequency is associated with the number of GCCs, the grid impedance and even the capacitive loads. By controlling the grid-side current instead of the converter-side current, the critical LCL filter is restricted as an internal component. Thus, the closed-loop output impedance of the GCC within the filter can be configured. The proposed scheme actively regulates the output impedance of the GCC to match the impedance of the external network, based on the detected resonance frequency. As a result, the resonance risk of multiple GCCs can be avoided, which is beneficial for the plug-and-play property of the GCCs in microgrids. Simulation and experimental results validate the effectiveness of the proposed method.

Controllable Harmonic Generating Method for Harmonic Impedance Measurement of Traction Power Supply Systems Based on Phase Shifted PWM

  • Liu, Qiujiang;Wu, Mingli;Li, Jing;Zhang, Junqi
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1140-1153
    • /
    • 2018
  • The harmonic impedance characteristic of a traction power supply system (TPSS) is necessary for taking actions to suppress the high-order harmonic resonances caused by AC electric locomotives. This paper proposes a controllable harmonic generating method (CHGM) for measuring the TPSS harmonic impedance by injecting harmonic disturbances of different frequencies and amplitudes into the TPSS. This method applies phase shifted pulse-width modulation (PSPWM) and ensures that the undesired sideband harmonics can be negligible while the desired harmonic is both controllable and adjustable. Multiple harmonics can be emitted at the same time. The implementation of the method is also presented. Simulations are carried out to validate the performance of the proposed method. Finally, experimental results on a 5 H-bridge converters platform verified the effectiveness and feasibility of the proposed method.

Novel Oscillator Incorporating a Compact Microstrip Ring Type Resonant Cell with High Efficiency and Superior Harmonic Characteristics

  • Hwang Cheol-Gyu;Myung Noh-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • 제5권2호
    • /
    • pp.92-96
    • /
    • 2005
  • This paper presents a novel microwave oscillator incorporating a simple microstrip ring type resonant cell as its terminating resonance component. Reduced chip size, higher dc-ac power efficiency, superior harmonic characteristics can be achieved from the introduction of a compact microstrip ring resonator cell. The oscillator provides a second harmonic suppression of 26.51 dB and the output power of 2.046 dBm at 2.11 GHz.

전력계통에 있어서 FC - TCR 장치의 고조파 제어에 관한 연구 (A Study on Harmonic Elimination of FC-TCR in Power System)

  • 김준현;김영만;이승주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.127-130
    • /
    • 1988
  • This paper describes digital simulation of harmonic elimination in the FC-TCR. (Fixed Capacitor and Thyristor Controlled Reactor) A model at harmonic frequency is developed for a STATIC VAR compansator. The model is shown to be useful in predicting resonance condition. A new variable filter is used for synthesized harmonic elimination.

  • PDF

오차의 허용범위를 고려한 수동형 필터의 특성 해석 (Performance Analysis for Passive Filter Considering Allowable Limits of Tolerance)

  • 김종겸;김일증
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.38-43
    • /
    • 2009
  • Reactors are connected with capacitors to passive filter circuits for reducing harmonics caused by power conversion application. This passive filter frequently gets out of order by voltage and current stress. Especially filter reactor has too much voltage harmonics components, its trouble rate is higher than capacitor. In this paper, we analyzed voltage and current of reactor and capacitor used for passive filter by simulation and measurement. If reactor has a tolerance on variation of reactance value, series resonance frequency is different from originally filter design frequency and parallel resonance can be generated at the close point of the former. Because filter absorbs harmonic component of non-linear load, much of harmonic voltage has been impacted on reactor.

1/2파장 열음향 냉동기의 공명관 길이 의존 특성 연구 (An Experimental Study that depend on the Resonance Tube Length for a Thermoacoustic Refrigerator of 1/2 wave)

  • 송규조;박종호;고득용;김효봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.217-222
    • /
    • 2001
  • The thermoacoustic refrigerator has not only considerable possibility but also commercial usability, because it has high reliability, lower vibration, no moving part, and can easily be constructed. In this study, the resonance characteristics of the thermoacoustic refrigerator were investigated for better performance, varying the length of Resonant Tube to 400mm $\sim850mm$. In order to determine the optimum position of stack in the resonance tube and the frequency, the simple $\lambda/2$ thermoacoustic refrigerator was constructed. It was used air as a coolant. in the fifth harmonic, it was taken the highest ${\Delta}t$ that was $52.6^{\circ}C$ at 827Hz in 400mm tube with 40mm stack.

  • PDF

코일스프링과 오일댐퍼를 가지는 동흡진기의 특성에 관한 연구 (A Study on the Characteristics of Dynamic Vibration Absorber with Coil Spring and Oil Damper)

  • 김광식;안찬우
    • 한국해양공학회지
    • /
    • 제2권1호
    • /
    • pp.170-175
    • /
    • 1988
  • A study on the dynamic vibration absorber with coil spring and oil damper was carried out both theoretically and experimentally. A main mass is attached to a foundation using coil spring and oil damper. A harmonic motion was applied to the foundation. The effects of the dynamic vibration sbsorber are theoretically summarized in graphs, and tested on a vibratory model for the isolation of actual mechanical vibration. As a result, the first resonance amplitude ratio increased and the second resonance amplitude ratio decreased as the absorber spring constant increased. When the absorber mass increase, the first resonance amplitude ratio is decreased and the second resonace amplitude ratio is increased.

  • PDF

Second Harmonic Generation and Frequency Stabilization of a Diode Laser Using an External Ring Resonator

  • Kwon, Taeg-Yong;Yang, Sung-Hoon;Lee, Ho-Seong
    • Journal of the Optical Society of Korea
    • /
    • 제2권1호
    • /
    • pp.1-4
    • /
    • 1998
  • The second harmonic light of an 842 nm diode laser was generated from a KNbO3 crystal in an external ring resonator. The power of the second harmonic light was about 0.8 mV at an input fundamental power of 87 mW. The laser frequency was stabilized to the resonance frequency of the ring resonator, and the frequency fluctuation was measured as about 3 MHz.

감속기에 의한 로보트 진동 특성 고찰 (Vibration of The Robot Due to Rducers)

  • 하태광
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.149-152
    • /
    • 1986
  • Vibration characteristics of harmonic drives and cyclo drives are reviewed. Both of two have two resonance frequencies inherently. Especially, the amplitudes of cyclo drives are over 1.0g. The test of the robot also shows large amplitude of vibration in the speed which is coincide with the resonance frequencies of reducers.

  • PDF

DFIG 풍력발전기가 연계된 배전선로의 고조파 공진 특성에 관한 연구 (A Study on Harmonic Resonance in a DFIG Wind Turbine-generator Connected to a Distribution Power Line)

  • 최형주;이흥호
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1383-1389
    • /
    • 2013
  • There were telecommunication noise and malfunctions of the electronic devices occurred over a wide area due to the high harmonic voltage and/or current levels of the Back-to-back converter in the DFIG wind power system even though the magnitude of all harmonics is within the international standards. The triangular carrier signals of the PWM used in the power converter system is related to the telecommunication noise because they are in the range of audible frequencies and amplified by a variety of the standing waves that were excited by harmonic voltage sources in the weak grid system such as a long distance distribution transmission lines. This paper describes the characteristics of the harmonics in the wind turbine-generator, numerical analysis and simulation of the harmonics resonance phenomena in the distribution lines as well as measuring induced voltage of the telecommunication lines in parallel with power lines in order to verify the root cause of the telecommunication noise. These noise problems can occur in a wind turbine power system with a non-linear converter at any time, as well as photovoltaic power system. So, the preliminary review of suitable filter devices and switching frequencies of the PWM have to be required by considering the stability of the controller at the design stage but as part of the measures the effect of the telecommunication cable shields was analyzed by comparing the measured data between multi-conductor with/without shields so as to attenuate the sources of the harmonics voltage induced into the telecommunication lines and to apply the most cost-effective measures in the field.