• Title/Summary/Keyword: Harmonic Currents

Search Result 343, Processing Time 0.027 seconds

A Study on Active Power Filter for Compensation of Power Factor and Harmonic Currents (역률개선 및 고조파 보상을 위한 능동전력필터에 관한 연구)

  • Kim, Y.H.;Kim, J.S.;Kwon, G.H.;Chung, Y.H.;Choi, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1074-1076
    • /
    • 1992
  • By using nonlinear loads in power line, reactive power and harmonics are occured. In this thesis, on the basis of the instantaneous reactive power theory, the calculation method of compensation current commands and the current control characteristics of active power filter using voltage source PWM converter are presented. The calculation of compensation current is performed by DSP within 50 usec. And the Pl control of current is performed by analog devices. The compensations of harmonic current in rectifier loads and unbalance currents are proved by experiments.

  • PDF

Rapid Tidal Predictions for the Inchon Bay (인천항 조석의 신속 예보)

  • 최병호
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.4
    • /
    • pp.355-367
    • /
    • 1995
  • Tidal prediction at a given location has been conventionally made by harmonic method. Another means of tidal prediction is through numerical modeling of tides. Present research focussed on whether prediction of tides and tidal currents can be made everywhere in the Inchon Bay using the numerical model directly or by harmonic constants of tides and tidal currents of the whole Bay derived from the extended model run.

  • PDF

The VSI active power filter in 3-phase unsymmetrical voltage system (3상 불평형 전압 시스템에서의 전압원 active power filter)

  • Kim, Gap-Dong;Lee, Wan-Soo;Kim, Min-Tae;Oh, Sung-Up;Joo, Hyung-Joon;Lee, Jin;Sung, Se-Jin
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.667-670
    • /
    • 1999
  • An active power filter is used to eliminate harmonic currents. This paper applied the extension pq theory to harmonic currents compensation. An active power filter based on extension pq theory is more effective than pq theory in 3-phase unsymmetrical voltage system. When extension pq theory is used, the result of simulation present source current is not distorted. Pulse-width modulation method is CRPWM(Current-Regulated PWM).

  • PDF

Winding Disposition to Minimize the Output Interference of Transformers for the High-Speed EMU (동력 분산형 고속철도용 변압기의 출력 간섭현상을 저감시키기 위한 권선 배치 방법)

  • Park, Byoung-Gun;Ahn, Sung-Kuk;Hyun, Dong-Seok
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1873-1877
    • /
    • 2010
  • In the high-speed EMU, the modularized traction converter produces the significant harmonic currents caused from the switching behavior of a power converter. These harmonic currents bring the interference among the traction equipment. One way to minimize the interference is to design the secondary windings of a power transformer decoupled magnetically as possible. This paper presents a magnetic field analysis on a winding disposition to clarify an impact on magnetic decoupling between secondary windings, under a limited height of a train. Two winding dispositions for a single-phase shell-type transformer are constructed and simulated by a three-dimensional finite elements method (FEM) model. Two different winding dispositions are constructed and simulated by three-dimensional FEM model using Maxwell3D.

  • PDF

Extension of the Operating Speed for Vector-Controlled Induction Machine Drives in the Overmodulation Range

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.477-486
    • /
    • 2012
  • This paper proposes a novel current control scheme for vector-controlled induction machine (IM) drives in the overmodulation (OVM) range, with which the voltage utilization of the voltage-source inverter (VSI) can be maximized. In the OVM region, the original voltage reference is modified by changing its magnitude and angle, which causes the motor current to be distorted, resulting in a deterioration of the current control performance. To meet with this situation, the harmonic components in the feedback currents should be eliminated before being input to the PI current controllers. For this, a composite observer is applied to extract the fundamental and harmonic components from the distorted currents, which gives a good performance without a delay and the effect of a fundamental frequency variation. In addition, through a detailed analysis of the response of the PI current controllers in the OVM range, the effectiveness of using the composite observer is demonstrated. Simulation and experimental results for a 3-kW induction motor drive are shown to verify the validity of the proposed method.

A New Low Cost Hybrid Power Filter for Thyristor-Controlled Rectifier Load (싸이리스터 정류부하를 위한 새로운 저원가 복합형 전력필터)

  • 한성룡;김수근;석원엽;조정구;송의호;전희종
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.1
    • /
    • pp.24-29
    • /
    • 2004
  • A new low cost hybrid active filter for thyristor-controlled rectifier load is presented to overcome the high cost problem of the active or the other hybrid active filters. The proposed hybrid active filter which consists of tuned (5th and 7th harmonics) LC passive filters, power factor improvement(PFI) capacitor bank, and active filter compensates power factor as well as harmonic currents. Since most of harmonic currents are filtered by the passive filter and most of reactive power is compensated by the PFI capacitor bank, the power rating of active filter can be minimized, resulting in cost minimization of the proposed hybrid active filter. A 300kVA hybrid active filter system is implemented and tested using 1MVA thyristor rectifier load to verify the operation and performance.

Feature Extraction of Fault Current using Fourier Transform in the Multi-Shot Reclosing Scheme (푸리에 변환을 이용한 다중 재폐로방식에서의 사고전류 특징 추출)

  • O, Jeong-Hwan;Yun, Sang-Yun;Kim, Jae-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.2
    • /
    • pp.50-55
    • /
    • 2000
  • This paper presents the feature extraction of fault currents related to the multi-shot reclosing scheme in the power distribution system. In order to get the fault current waveform, we have measured the fault currents by the fault recorders which have been installed at the secondary side of 154/22.9[kV] substation transformer. These waveforms are classified into temporary and permanent fault. For the classified waveforms, Fourier transform is used to extract the feature of the fault current waveforms. After the waveforms are analyzed by using Fourier transform, the magnitude spectrum and the relative variation of THD (Total Harmonic Distortion) are calculated. And then the relative variation of THD is great in the temporary faults, and is small in the permanent faults.

  • PDF

An Improved Control Approach for DSTATCOM with Distorted and Unbalanced AC Mains

  • Singh, Bhim;Solanki, Jitendra
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.131-140
    • /
    • 2008
  • This paper presents a new control approach of DSTATCOM (distribution static compensator) for compensation of reactive power, unbalanced loading and harmonic currents under unbalanced non-sinusoidal ac mains. The control of DSTATCOM is achieved using Adaline based current estimator based on LMS algorithm to maintain source currents real and undistorted. The dc bus voltage of voltage source converter (VSC) working as DSTATCOM is maintained at constant voltage using a proportional-integral (PI) controller. The DSTATCOM system alongwith proposed control scheme is modeled in MATLAB to simulate the behavior of the system. The practical implementation of the DSTATCOM is carried out using dSPACE DS1104 R&D controller having TMS320F240 as a slave DSP. Simulated and implementation results are presented to demonstrate the effectiveness of the DSTATCOM with Adaline based control to meet the severe load perturbations with different types of loads (linear and non-linear) under distorted and unbalanced AC mains.

A Revisit to the Myungryang Naval Battle through Hindcasting Tidal Currents and Tides (명량해전 당일 울돌목 조류.조석 재현을 통한 해전 전개 재해석)

  • Byun, Do-Seong;Lee, Min-Woong;Lee, Ho-Jung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.189-197
    • /
    • 2011
  • As a multidisciplinary study encompassing oceanography and history, we have attempted to reanalyze the course of a historical navel battle, Myungryang Naval Battle(September 16th, 1597 according to the lunar calendar) through hindcasting the paleo-tidal currents and -tides(PTC). Firstly, we conducted harmonic analysis using 6-month current data observed at Uldolmok and 1-year elevation data provided by Korea Ocean Research and Development Institute in order to understand their characteristics and to hindcast the PTC. Observation results show that Uldolmok, ~300m wide, relatively narrow channel, is characterized by a flood-dominant mixed mainly semidiurnal tidal regime induced by relatively-strong shallow water constituents, showing closely a standing wave type of tidal current. Further, we hindcasted PTC on the day of Myungryang Naval Battle. Our results were compared and discussed with results(time and speeds of maximum(flood and ebb) currents and high and low water times) of the previous studies estimated from different methods. Lastly, we reconstruct the course of the event of Myungryang Naval Battle recorded in the Admiral Sun-Sin Yi's War Diary(Nangjung Iigi in Korean) based on our hindcasting results.

A novel grey TMD control for structures subjected to earthquakes

  • Z.Y., Chen;Ruei-Yuan, Wang;Yahui, Meng;Timothy, Chen
    • Earthquakes and Structures
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • A model for calculating structure interacted mechanics is proposed. A structural interaction model and controller design based on tuned mass damping (TMD) was developed to control the induced vibration. A key point is to introduce a new analytical model to evaluate the properties of the TMD that recognizes the motion-dependent nonlinear response observed in the simulations. Aiming at the problem of increased current harmonics and low efficiency of permanent magnet synchronous motors for electric vehicles due to dead time effect, a dead time compensation method based on neural network filter and current polarity detection is proposed. Firstly, the DC components and the higher harmonic components of the motor currents are obtained by virtue of what the neural network filters and the extracted harmonic currents are adjusted to the required compensation voltages by virtue of what the neural network filters. Then, the extracted DC components are used for current polarity dead time compensation control to avert the false compensation when currents approach zero. The neural network filter method extracts the required compensation voltages from the speed component and the current polarity detection compensation method obtains the required compensation voltages by discriminating the current polarity. The combination of the two methods can more precisely compensate the dead time effect of the control system to improve the control performance. Furthermore, based on the relaxed method, the intelligent approach of stability criterion can be regulated appropriately and the artificial TMD was found to be effective in reducing cross-wind vibrations.