• Title/Summary/Keyword: Harmful air

Search Result 418, Processing Time 0.03 seconds

Qualitative and quantitative analysis of furosine in fresh and processed ginsengs

  • Li, Yali;Liu, Xiaoxu;Meng, Lulu;Wang, Yingping
    • Journal of Ginseng Research
    • /
    • v.42 no.1
    • /
    • pp.21-26
    • /
    • 2018
  • Background: Furosine (${\varepsilon}$-N-2-furoylmethyl-L-lysine, FML) is an amino acid derivative, which is considered to be an important indicator of the extent of damage (deteriorating the quality of amino acid and proteins due to a blockage of lysine and a decrease in the digestibility of proteins) during the early stages of the Maillard reaction. In addition, FML has been proven to be harmful because it is closely related to a variety of diseases such as diabetes. The qualitative analysis of FML in fresh and processed ginsengs was confirmed using HPLC-MS. Methods: An ion-pair reversed-phase LC method was used for the quantitative analysis of FML in various ginseng samples. Results: The contents of FML in the ginseng samples were 3.35-42.28 g/kg protein. The lowest value was observed in the freshly collected ginseng samples, and the highest value was found in the black ginseng concentrate. Heat treatment and honey addition significantly increased the FML content from 3.35 g/kg protein to 42.28 g/kg protein. Conclusion: These results indicate that FML is a promising indicator to estimate the heat treatment degree and honey addition level during the manufacture of ginseng products. The FML content is also an important parameter to identity the quality of ginseng products. In addition, the generation and regulation of potentially harmful Maillard reaction products-FML in ginseng processing was also investigated, providing a solid theoretical foundation and valuable reference for safe ginseng processing.

Characteristics of Bovine Teeth Whitening in Accordance with Gas Environments of Atmospheric Pressure Nonthermal Plasma Jet

  • Sim, Geon Bo;Kim, Yong Hee;Kwon, Jae Sung;Park, Daehoon;Hong, Seok Jun;Kim, Young Seok;Lee, Jae Lyun;Lee, Gwang Jin;Lim, Hwan Uk;Kim, Kyung Nam;Jung, Gye Dong;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.250.2-250.2
    • /
    • 2014
  • Currently, teeth whitening method which is applicable to dental surgery is that physician expertises give medical treatment to teeth directly dealed with a high concentration of hydrogen peroxide and carbamide peroxide. If hydrogen peroxide concentration is too high for treatment of maximized teeth whitening effect [1], it is harmful to the human body [2]. To the maximum effective and no harmful teeth whitening effect in a short period of time at home, we have observed the whitening effect using carbamide peroxide (15%) and a low-temperature atmospheric pressure plasma jet which is regulated by the Food and Drug Administration. The gas supplied conditions of the non-thermal atmospheric pressure plasma jet was with the humidified (0.6%) gas in nitrogen or air at gas flow rate of 1000 sccm. Also, the measurement of chemical species from the jet was carried out using the optical emission spectroscopy (OES), the evidence of increased reactive oxygen species compared to non-humidified plasma jet. We have found that the whitening effect of the plasma is very excellent through this experiment, when bovine teeth are treated in carbamide peroxide (15%) and water vapor (0.2 to 1%). The brightness of whitening teeth was increased up to 2 times longer in the CIE chromaticity coordinates. The colorimetric spectrometer (CM-3500d) can measure color degree of whitening effect.

  • PDF

Reduction and Decomposition of Hazardous NOx by Discharge Plasma with $TiO_2$ ($TiO_2$ 촉매를 이용한 플라즈마반응에 의한 NOx의 분해)

  • Park, Sung-Gug;Woo, In-Sung;Hwang, Myung-Whan
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.54-60
    • /
    • 2008
  • The objective of this study is to obtain the optimal process condition and the maximum decomposition efficiency by measuring the decomposition efficiency, electricity consumption, and voltage in accordance with the change of the process variables such as the frequency, maintaining time period, concentration, electrode material, thickness of the electrode, the number of windings of the electrode, and added materials etc. of the harmful atmospheric contamination gases such as NO, $NO_2$, and $SO_2$ etc. with the plasma which is generated by the discharging of the specially designed and manufactured $TiO_2$ catalysis reactor and SPCP reactor. The decomposition efficiency of the NO, the standard samples, is obtained with the plasma which is being generated by the discharge of the combination effect of the $TiO_2$ catalysis reactor and SPCP reactor with the variation of those process variables such as the frequency of the high voltage generator($5{\sim}50kHz$), maintaining time of the harmful gases($1{\sim}10.5sec$), initial concentration($100{\sim}1,000ppm$), the material of the electrode(W, Cu, Al), the thickness of the electrode(1, 2, 3mm), the number of the windings of the electrode(7, 9, 11turns), basic gases($N_2$, $O_2$, air), and the simulated gas($CO_2$) and the resulting substances are analyzed by utilizing FT-IR & GC.

Performance Evaluation of Eco-friendly Insulating Finish According to the Addition Ratio of Granular Cork (입상 코르크 첨가율에 따른 친환경 단열마감재의 성능평가)

  • Kim, Yong-Gu;Kim, Yeon-Ho;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.148-149
    • /
    • 2020
  • Currently, the most commonly used EPS insulation material has been mainly used because its ease of adhesion with concrete. However, due to poor adhesion with wallpaper, separate adhesion needs to be strengthened and there are cases of breakage or grooves in the process of dismantling the mold. The biggest problem is that when a fire breaks out, various harmful substances are present and highly flammable. Cork used in this study is a truly eco-friendly building material that is taken from between the outer and inner bark of cork trees and does not damage the wood. Also, it is a porous material that is made up of countless cells and contains an air gap between the cells. It is very light in weight between 0.06 and 0.07 and has excellent insulation with a heat conductivity of 0.04W/mK. In addition, it has high stability in the topic of conversation because it does not produce harmful gas when burned and has self-sustaining properties. However, research on cork, an eco-friendly building material with excellent performance to date, is scarce Therefore, we encourage existing scholars to raise interest in new eco-friendly building materials through this study. It also aims to manufacture insulation boards with new inorganic properties using the low weight and heat conductivity held by the cork.

  • PDF

A Time-Series Study of Ambient Air Pollution in Relation to Daily Mortality in Seoul, 1998∼2001 (서울시 대기오염과 일별 사망의 상관성에 관한 시계열적 연구 (1998∼2001년))

  • Cho, Yong-Sung;Lee, Jong-Tae;Kim, Yoon-Sin;Hong, Seung-Cheol;Kim, Ho;Ha, Eun-Hee;Park, Hye-Sook;Lee, Bo-Eun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.625-637
    • /
    • 2003
  • This study was performed to examine the relationship between air pollution exposure and mortality in Seoul for the years of 1998∼2001. Daily counts of death were analyzed by general additive Poisson model, with adjustment for effects of seasonal trend, air temperature, humidity, and day of the week as confounders in a nonparametric approach. Daily death counts were associated with CO (current day),O$_3$ (current day), PM$_{10}$ (current day), NO$_2$ (1 day before), SO$_2$ (1 day before). Increase of 41.71 $\mu\textrm{g}$/㎥ (interquartile range) in PM$_{10}$ was associated with 1.3% (95% CI = 0.7∼1.9%) increase in the daily number of death. $O_3$ concentrations resulted in an increased risk of 1.3% for 23.86 ppb in all-aged mortality [RR = 1.013 (1.004-1.023)1. This effect was greater in children (less than 15 aged) and elderly (more than 65 aged). After ozone level exceeds 25 ppb, the dose-response relationship between mortality and ozone was almost linear. We concluded that Seoul had 1∼5% increase in mortality in association with IQR (interquartile range) in air pollutants. Daily variations in air pollution within the range currently occurring in Seoul might have an adverse effect on daily mortality. These findings also support the hypothesis that air pollution, at levels below the current ambient air quality standards of Korea, is harmful to sensitive subjects, such as children or elderly.rly.

Estimation of Benzene Emissions from Mobile Sources in Korea (국내 이동오염원에서 발생되는 벤젠 배출량 산정)

  • Lee, Ju-Hyoung;Cha, Jun-Seok;Hong, Ji-Hyung;Jung, Dong-Il;Kim, Ji-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.72-82
    • /
    • 2008
  • Benzene is a very harmful and toxic compound known as human carcinogen by all routes of exposure. Owing to the risky feature of benzene, several countries such as Japan, UK and EU have established the ambient air quality standard and protect from that risk of it. Korea also has designated it as one of the criteria air pollutants and established the concentration limit ($5\;{\mu}g/m^3$) in the air and is going to apply the standard from 2010. Benzene is emitted from various sources such as combustion plants, production processes, waste treatment facilities and also automobiles. Mobile source is known as one of the major emission sources of benzene. In this study, we estimated the domestic emissions of benzene from mobile source and compared the results with those of advanced countries. Mobile source was divided into 2 categories, Le., on-road source and non-road source. The total emissions of benzene from mobile source were estimated as 3,106 tons/yr and 1,612 tons/yr was emitted from on-road source and 1,494 tons/yr was from non-road source. Emission ratio of benzene from on-road source showed that 80.0% was from passenger cars, 10.1% was from taxis, 7.2% was from light-duty vehicles, 2.5% was from heavy-duty vehicles and 0.2% was from buses. In the case of non-road source, the distribution showed that 66.3% was from construction machineries, 14.5% was from locomotives, 11.7% was from ships, 7.1% was from agriculture equipments and 0.5% was from aircrafts. The cold-start emissions were estimated as 942 tons/yr and this value was almost 1.5 times greater than that for hot engine emissions (608 tons/yr). In addition, the fuel-based distribution was 65.9%, 31.1% and 2.8% from gasoline, LPG and diesel vehicles, respectively. The emission ratio from mobile source occupied 65% and 30% of total benzene emissions in USA and UK, respectively. In case of Korea, the emission ratio of benzene from mobile source occupied 29% (15% from on-road source, 14% from non-road source) which showed similar value with UK.

The Risk Assessment of Carbon Monoxide Poisoning by Gas Boiler Exhaust System and Development of Fundamental Preventive Technology (가스보일러 CO중독 위험성 예측 및 근원적 예방기술 개발)

  • Park, Chan Il;Yoo, Kee-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.27-38
    • /
    • 2021
  • We devised the system to automatically shutdown the boiler and to fundamentally block the harmful gases, including carbon monoxide, into the indoor when the exhaust system swerves: (1) The discharge pressure of the exhaust gas decreases when the exhaust pipe is disconnected. The monitoring system of the exhaust pipe is implemented by measuring the output voltage of APS(Air Pressure Sensor) installed to control the amount of combustion air. (2) The operating software was modified so that when the system recognizes the fault condition of a flue pipe, the boiler control unit displays the fault status on the indoor regulator while shutting down the boiler. In accordance with the ventilation facility standards in the "Rules for Building Equipment Standards" by the Ministry of Land, Infrastructure and Transport, experiments were conducted to ventilate indoor air. When carbon monoxide leaked in worst-case scenario, it was possible to prevent poisoning accidents. However, since 2013, the number of indoor air exchange times has been mitigated from 0.7 to 0.5 times per hour. We observed the concentration exceeding TWA 30 ppm occasionally and thus recommend to reinforce this criterion. In conclusion, if the flue pipe fault detection and the indoor air ventilation system are introduced, carbon monoxide poisoning accidents are expected to decrease significantly. Also when the manufacturing and inspection steps, the correct installation and repair are supplemented with the user's attention in missing flue, it will be served to prevent human casualties from carbon monoxide poisoning.

International Space Law on the Protection of the Environment (환경보호에 관한 국제 우주법연구)

  • Kim, Han-Taek
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.25 no.1
    • /
    • pp.205-236
    • /
    • 2010
  • This article deals with international space law for the environmental protection in outer space especially for space debris arising from space activities. After studying 1967 Outer Space Treaty, 1968 Rescue Agreement, 1972 Liability Convention, 1975 Registration Convention and 1979 Moon Agreement, we could find few provisions dealing with space environment in those treaties. During the earlier stages of the space age, which began in the late 1950s, the focus of international law makers was the establishment of the basic rules of space law governing the states' activities in outer space. Consequently the environmental issues and the risks that might arise from the generation of the space debris did not receive priority attention within the context of the development international space law. Although the phrases such as 'harmful contamination', 'harmful interference', 'disruption of the environment', 'adverse changes in the environment' and 'harmfully affecting' in relation to space environment were used in 1967 Outer Space Treaty and 1979 Moon Agreement, their true meaning was not definitely settled. Although 1972 Liability Convention deals with compensation, whether the space object covers space debris is unclear despite the case of Cosmos 954. In this respect international lawyers suggest the amendment of the space treaties and new space treaty covering the space environmental problems including the space debris. The resolutions, guidelines and draft convention are also studied to deal with space environment and space debris. In 1992 the General Assembly of the United Nations passed resolution 47/68 titled "Principles Relevant to the Use of Nuclear Power Sources in Outer Space" for the NPS use in outer space. The Inter-Agency Space Debris Coordination Committee; IADC) issued some guidelines for the space debris which were the basis of "the UN Space Debris Mitigation Guidelines" approved by COPUOS in its 527th meeting. In 1994 the 66th conference of ILA adopted "International Instrument on the Protection of the Environment from Damage Caused by Space Debris". Although those resolutions, guidelines and draft convention are not binding states, there are some provisions which have a fundamentally norm-creating character and softs laws.

  • PDF

A Study on the Integrated Fusion Technology Between a Carbon Dioxide Emission and a District Cooling Energy Using a Cold Energy ($CO_2$ 배출문제와 냉열이용 지역집단 냉방에너지에 관한 통합적 융합기술 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.34-40
    • /
    • 2006
  • This paper provides a fusion technology between a district cooling energy system and an environment conservation policy based on the energy savings and reusable cold energy resources. The district heating and cooling systems are very effective ways for an energy saving, a cost reduction and a safety control. It is necessary to equalize the energy savings and an environmental preservation policy for an improved human lift. A gasification process of a liquefied natural gas, cooling water from deep seawater and an ice water thermal storage system may produce a cold energy. A district cooling system is used to cool an apartment, office buildings and factory facilities with a cooling energy supply pipeline. LNG cooling energy will switch a conventional air-conditioning system, which is operated by on electrical energy and a Freon refrigerant. Coincident with significant clean energy and operating cost savings, LNG cold energy system owen radical reductions in an air-borne pollutant, $CO_2$ and the release of environmentally harmful refrigerants compared with that of the conventional air-conditioning system. This study provides useful information on the fusion technology of a LNG cold energy usage and energy savings, and environmental conservation.

  • PDF

Foam Separation in Recirculating Aquaculture System (순환여과식 양어장의 포말분리)

  • SUH Kuen-Hack;LEE Min-Gyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.2
    • /
    • pp.239-243
    • /
    • 1997
  • A continuous foam separator has been used to remove TSS, $NH_3\;and\;NO_2^-$ from the recirculating water in aquaculture. Experimental runs were carried out to determine the foam separation variables, such as, hydraulic retention time, superficial air velocity and foam .height. The removal efficiency of TSS, $NH_3\;and\;NO_2^-$ was increased with hydraulic retention time and superficial air velocity, and removal efficiency of $NH_3$ was increased steadily with foam height. As DO concentration was increased with superficial air velocity and foam height, foam separator is also used for oxygen addition. It was concluded that foam separator might offer better perspective for removal of harmful components in fish culture water.

  • PDF