• Title/Summary/Keyword: Hardware complications

Search Result 27, Processing Time 0.022 seconds

Clinical Experience of Anterior Cervical Interbody Fusion with the PCB System (전방 경추 유합술에서의 PCB System의 임상적 경험)

  • Kim, Sung Han;Kim, Ho Jin;Kang, Jae Kyu;Doh, Jong Oung;Lee, Chun Dae
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1170-1176
    • /
    • 2001
  • Objective : The purpose of the study was to evaluate the clinical and radiological results after discectomy and Lubboc bone graft in the surgical management of the cervical diseases with a new titanium interbody implant and integrated screw fixation(PCB) by anterior approach. Methods : The authors retrospectively analyzed 28 cases of anterior cervical fusion with PCB system and Lubboc bone(xeno graft) from september 1998 to december 2000. Twenty-eight patients with cervical diseases underwent decompression cervical lesion and followed from 5 to 27 months with a mean follow-up of 14 months. There patients were evaluated with clinically and radiologically at immediate postoperative period and at 3, 6, 9, and 12 months. Result : The authors investigated the pre- and postoperative intervertebral disc space, clinical outcomes, radiography fusion rate, and Cobb angle in the fixed segments by anterior approach. The lordotic angles and height of disc space were increased after the operation. The clinical outcome of patients follow-up was good or excellent result based on Odom's criteria with improvement of clinical symptom in about 92.9% of the cervical diseases. Two patients showed loosening of the lower and upper cervical screw of PCB instruments, and two patients showed swallowing difficulty and wound infection Conclusion : The PCB system is a new implant for anterior cervical interbody fusion in the degenerative cervical disease and disc herniations. It provides immediate stability and segment distraction. The results of this study indicate that the PCB system is safe, easy handling of hardware, less complications, high fusion rate, and has provide the keeping the intervertebral disc space height and lordotic angles.

  • PDF

Bone Cement Augmentation of Short Segment Fixation for Unstable Burst Fracture in Severe Osteoporosis

  • Kim, Hyeun-Sung;Park, Sung-Keun;Joy, Hoon;Ryu, Jae-Kwang;Kim, Seok-Won;Ju, Chang-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.1
    • /
    • pp.8-14
    • /
    • 2008
  • Objective : The purpose of this study was to determine the efficacy of short segment fixation following postural reduction for the re-expansion and stabilization of unstable burst fractures in patients with osteoporosis. Methods : Twenty patients underwent short segment fixation following postural reduction using a soft roll at the involved vertebra in cases of severely collapsed vertebrae of more than half their original height. All patients had unstable burst fracture with canal compromise, but their motor power was intact. The surgical procedure included postural reduction for 2 days and bone cement-augmented pedicle screw fixations at one level above, one level below and the fractured level itself. Imaging and clinical findings, including the level of the vertebra involved, vertebral height restoration, injected cement volume, local kyphosis, clinical outcome and complications were analyzed. Results : The mean follow-up period was 15 months. The mean pain score (visual analogue scale) prior to surgery was 8.1, which decreased to 2.8 at 7 days after surgery. The kyphotic angle improved significantly from $21.6{\pm}5.8^{\circ}$ before surgery to $5.2{\pm}3.7^{\circ}$ after surgery. The fraction of the height of the vertebra increased from 35% and 40% to 70% in the anterior and middle portion. There were no signs of hardware pull-out, cement leakage into the spinal canal or aggravation of kyphotic deformities. Conclusion : In the management of unstable burst fracture in patients with severe osteoporosis, short segment pedicle screw fixation with bone cement augmentation following postural reduction can be used to reduce the total levels of pedicle screw fixation and to correct kyphotic deformities.

Anterior Cervical Instrumentation Using Intradiscal Cage with Integrated Plate

  • Ahn, Kyoung-Rok;Ryu, Kyeong-Sik;Chang, In-Bok;Cho, Byung-Moon;Park, Se-Hyuck;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.260-264
    • /
    • 2006
  • Objective : The retrospective study is undertaken to report clinical results of anterior cervical interbody fusion with an intradiscal cage with an integrated plate [PCB cervical plating system]. Methods : 38 patients underwent anterior cervical interbody fusion with PCB cervical plating system and followed $6{\sim}24\;months$. The authors investigated overall surgical results; clinical outcome, fusion rate, change of interspace height & lordotic angle, and complications. Results : No complication was observed during the operation. Clinical improvement was identified in 34 cases [89.5%]. Bone fusion observed in 44 out of 49 sites [90.7%]. After operation, the interspace height increased from $5.4{\pm}1.3mm$ to $7.8{\pm}1.5mm$ and maintained $7.4{\pm}1.1mm$ and, interspace angle went up from $4.2{\pm}0.7^{\circ}$ to $4.8{\pm}1.1^{\circ}$ and maintained $4.6{\pm}$0.9^{\circ}. The loosening of screw was observed in 6 cases, one of which had reoperation because of the expulsion of the device accompanied. Conclusion : PCB cervical plating system could restore interbody height and lordosis in anterior cervical interbody fusion. But, if the insertion of the spacer is not precise, the frequencies of hardware failure are relatively high. It is considered necessary for the operator to be careful in the procedure.

Cement Augmentation of Dynamic Hip Screw to Prevent Screw Cut Out in Osteoporotic Patients with Intertrochanteric Fractures: A Case Series

  • Rai, Avinash Kumar;Goel, Rajesh;Bhatia, Chirag;Singh, Sumer;Thalanki, Srikiran;Gondane, Ashwin
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.269-275
    • /
    • 2018
  • Purpose: The purpose of this study is to describe a method of inserting cement in the femoral head before fixation with dynamic hip screw to prevent screw cut out due to osteoporosis and to evaluate its clinical outcome in these patients. Materials and Methods: In this prospective study, 30 patients aged 60 years and older with intertrochanteric fracture were included. Bone mineral density was measured. After reaming of the femoral head and neck with a triple reamer and polymethyl methacrylate, bone cement was introduced into the femoral head using a customized nozzle and a barrel fitted on a cement gun. A Richard screw was inserted and the plate was fixed over the femoral shaft. Patients were mobilized and clinical outcomes were rated using the Salvati and Wilson's scoring system. Results: More patients included in this study were between 66 and 70 years old than any other age group. The most common fracture according to the Orthopaedic Trauma Association classification was type 31A2.2 (46.7%). The T-score was found to be $-2.506{\pm}0.22$ (mean${\pm}$standard deviation); all patients were within the range of -2.0 to -2.8. The duration of radiological union was $13.67{\pm}1.77$ weeks. Salvati and Wilson's scoring at 12 months of follow up was $30.96{\pm}4.97$. The majority of patients were able to perform their normal routine activities; none experienced implant failure or screw cut out. Conclusion: Bone cement augmentation may effectively prevent osteoporosis-related hardware complications like screw cut out in elderly patients experiencing intertrochanteric fractures.

Arthroscopic Cannulated Screw Fixation Technique for Avulsion Fracture of the Intercondylar Eminence of the Tibia (삽관 나사못(Cannulated screw)을 사용한 경골 과간 융기부 견열 골절의 관절경적 치료 기법)

  • Lee, Kee-Byoung;Chang, Ho-Guen;Lee, Seok-Beom;Moon, Young-Wan;Kang, Ki-Hoon;Lee, Wook-Hyung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.127-131
    • /
    • 1999
  • Avulsion fractures of the intercondylar eminence of the tibia are not uncommon. In the displaced avulsion fracture, anatomical reduction and firm fixation of fracture fragments are needed but the most of the conventional operative techniques including arthroscopic technique are relatively complex and need. The results were not always satisfactory due to the risk of postoperative complications such as wound infection, premature epiphyseal closure and loss of fixation after early motion etc. So we describe a simple and safe modified method of arthroscopic reduction and fixation for avulsion fractures of the intercondylar eminence of the tibia. In our thirteen cases, we achieved anatomical reduction and secure fixation using cannulated screw through the three arthroscopic portals (anterolateral, medial mid-patellar and central). Postoperatively, immediate limited range of motion of the knee and partial weight bearing were possible. Additional use of the washer afforded safe fixation of comminuted avulsion fracture. The advantage of this technique includes its technical simplicity, easy removal of hardware, ability to treat comminuted type IV fracture with washer, no additional skin incision, no damage to growing plate in growth children and less morbidity.

  • PDF

Clinical Outcomes of Anterior Open Reduction and Posterior Percutaneous Screw Fixation for Displaced Talar neck Fractures (전방 정복술 및 경피적 후방 압박나사 내고정술을 이용한 전위성 거골 경부 골절의 치료 결과)

  • Park, Ji-Kang;Kim, Yong-Min;Choi, Eui-Sung;Shon, Hyun-Chul;Cho, Byung-Ki;Cha, Jung-Kwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.106-114
    • /
    • 2013
  • Purpose: Posteroanterior screw fixation is biomechanically stronger than anteroposterior screw fixation. However, there are few literature about the correlation between clinical results and more strength by posteroanterior fixation. This study was performed to evaluate the clinical outcomes of the accelerated rehabilitation following anterior open reduction and posterior percutaneous screw fixation for displaced talar neck fractures. Materials and Methods: Eighteen cases were followed up for more than 1 year after posteroanterior fixation using headless compression screw for talar neck fractures. The clinical evaluation was performed according to American Orthopaedic Foot and Ankle Society (AOFAS) score and Hawkins criteria. As radiographic evaluation, the degree of fracture displacement, period to union, and occurrence rate of complications such as avascular necrosis through MRI were measured. Results: The AOFAS score was average 90.4 points at the last follow-up. There were 7 excellent, 9 good, and 2 fair results according to the Hawkins criteria. Therefore, 16 cases(88.8%) achieved satisfactory results. The degree of fracture displacement had improved significantly from preoperative average 5.6 mm to 1.2 mm immediate postoperatively, and maintained to 1.1mm at the last follow-up. All cases achieved bone union, and the period to union was average 12.4 weeks. There were 3 cases of avascular necrosis of talar body and 2 cases of post-traumatic arthritis. Conclusion: Anterior open reduction and posterior percutaneous headless screw fixation seems to be an effective surgical method for displaced talar neck fractures, because of the possibility of accurate restoration of articular surface, fixation strength enough to early rehabilitation, and needlessness of hardware removal.

Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures (AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과)

  • Kim, Young-Mo;Lee, June-Kyu;Yang, Jae-Hoon;Kim, Bo-Kun;Lee, Won-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Purpose: To evaluate the usefulness of minimally invasive arthroscopy-assisted plate removal of a laterally inserted periarticular distal femur plate used for the treatment of AO type-C distal femur fractures. Materials and Methods: From October 2002 to November 2005, we evaluated 17 patients whose plates were removed through minimally invasive arthroscopy-assisted plate-removal technique and 15 patients who got their plates removed through conventional method without using arthroscopy, 32 patients in total. All these patients included in this study initially underwent open reduction and internal fixation of the distal femoral fractures with a lateral plate, and complained of continued pain over the lateral femoral condyle after the fracture fixation. The average age was 42.6 (ranges: 20~66) and initial fracture types included 16 cases of C1, 11 cases of C2, and 5 cases of C3 following AO/ASIF classification guidelines. Measured outcomes included: associated intra-articular pathologies, time needed to return to activities of daily living, patients' overall satisfaction, complications following the removal of hardware, and pain before and 6 months after the operation. Results: The distal-most end of the plate was placed in the knee joint in all cases and damage of the lateral articular capsule was found in 23 cases. Continuous wound discharge after surgery was found in one case who underwent arthroscopy-assisted plate removal, and it was treated by irrigation and re-suture. Average time needed to return to activities of daily living was 7 days in arthroscopy assisted group and 7.6 days in conventionally removed group. Fourteen patients (82.4%) who underwent arthroscopyassisted plate-removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 4.9 to 1.9, six months after the plate removal. Thirteen patients(86.7%) who underwent conventional plate removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 5.2 to 2.5, six months after the operation. Conclusion: Through minimally invasive arthroscopic-assisted plate removal, intrarticular pathology of the knee joint was able to be simultaneously identified and treated at the time of hardware removal. Damage of lateral capsule of the knee joint caused by the inserted plate for the treatment of type C distal femoral fracture was very frequently found and following the plate removal, patients experienced an improvement in pain score. We therefore recommend routine lateral distal femoral plate removal if the bony union is attained in such cases as type C distal femoral fractures whose distal most end of the plates are located in the joint.

  • PDF