• Title/Summary/Keyword: Hard plate

Search Result 181, Processing Time 0.022 seconds

Mathematical Model of Hard Disk Drive Actuator System (하드디스크 드라이브 액추에이터 시스템의 수학적 모델)

  • Gwon, Sun-Eok;Park, No-Yeol;Kim, Jun-O;Jeong, Tae-Geon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.12
    • /
    • pp.3080-3087
    • /
    • 2000
  • We obtain the mathematical model of the hard disk drive actuator system the system response data of the finite element analysis or experimental results. The model is base on the Rayleigh-Ritz method to approximate the dynamic response of the actuator system. The basic idea is to use the curve-fit technique to obtain the approximation coefficients. It allows the dynamic analysis of the actuator system without resort to the repetitive finite element modeling work. Even though the dynamic characteristics of the system of the system are affected somewhat by the structural modification and the change of the material properties, we can use the modified size and dynamic properties of the actuator system in the mathematical model to some extent. In this study, we express the mathematical model of the simplified rectangular plate first and then proceed to the actual hard disk drive actuator system.

PLEOMORPHIC ADENOMAS WHICH OCCURED IN THE SUBMANDIBULAR GLAND AND HARD PLATE;REPORTS OF TWO CASES (악하선(顎下腺)과 경구개(硬口蓋)에 발생한 다형성(多形性) 선종(腺腫)의 치험례)

  • Ha, Jong-Woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.2
    • /
    • pp.163-166
    • /
    • 1994
  • Pleomorphic adenoma(benign mixed tumor) is the most common tumor of the major salivary glands, constituting approximately 70 per cent of benign tumors of these glands. The term mixed tumor was introduced in the nineteenth century to stress the dual origin of this neoplasm from epithelial and mesenchymal elements, and the designation pleomorphic adenoma is preferred because it emphasizes both the epithelial origin and the variety of histological patterns found in this common salivary gland lesion. Rauch, in a review of 4245 pleomorphic adenomas, found 92.5 per cent in the major salivary glands and 6.5 per cent in the minor salivary glands, 8 per cent arose in the submandibular glands, and in another large series of over 6,000 cases, approximately 4 per cent arose in the hard and soft palates with equal frequency in each. The prognosis of pleomorphic adenoma depends more upon the choice and adequacy of treatment than upon histological appearances. The accepted treatment for this tumor is excision. With adequate surgery recurrence rates of less than 1 per cent can be obtained. In this hospital, I experienced two patients who were identified PMA which occurred in the hard palate and submandibular gland. The lesions were successfully treated by surgery.

  • PDF

Development of an Impact Force Measurement Device with an Attached Strain Gauge (스트레인게이지가 부착된 충격력 측정 장비 개발)

  • Jeong, Ik-Su
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.2
    • /
    • pp.243-251
    • /
    • 2012
  • The purpose of this study was to develop an impact force measurement device in order to facilitate the acquisition of quantitative data for the analysis of various sporting events. The device was designed to include cylindrical aluminum supports of 220 mm diameter, which allows mounting and dismounting of the device on walls and frames. In addition, a hard sponge for impact absorption, as well as 4 springs, were attached to the plate. Both were attached to prevent psychological variables and injuries. When a subject applies force on the device, accurate data about the maximum repulsive force is acquired in real time, with a lag of only 0.001 s. The device was calibrated in four steps: (1) increase, (2) increase, (3) increase-decrease, and (4) increase-decrease. The maximum relative expanded uncertainty was 0.166%, indicating that the impact force measurement was sufficiently reliable. The proposed device can be applied to various sporting situations and is expected to be useful for studying kinetics.

Analyses of Fouling Mechanism using Visualization Techniques in a Lab-scale Plate-Type Heat Exchanging System (실험실용 판형 열교환 시스템에서 가시화를 이용한 파울링 기구 해석)

  • 성순경;서상호;노형운
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.349-354
    • /
    • 2004
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When the scale deposits in a heat exchanger surface, it is conventionally called fouling. The objective of the present study is to analyze the process of the fouling formation in a heat exchanger according to different types of water using visualization techniques. In order to experimentally investigate the formation of the fouling, this study built a lab-scaled heat exchanging system. Using the visualization techniques of Scanning Electron Microscopy (SEM) and X-Ray diffraction method, the three dimensional configurations of the fouling formation could be successfully obtained. Based on the experimental results, it was found that the configurations of the fouling formation were different when using tap water compared to river water.

Dynamic Analysis of HDD Air Bearing Sliders using the Mathematical Model of Actuator System (액츄에이터 시스템의 수학적 모델을 이용한 HDD 공기 베어링 슬라이더의 동특성 해석)

  • Kwon, Soon-Eog;Park, No-Yeol;Kim, Jun-O;Jeong, Tae-Gun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.485-491
    • /
    • 2000
  • We obtain the mathematical model of the hard disk drive actuator system from the system response data of the finite element analysis or experimental results. System response data including the dynamics of the considered system are expressed as the mathematical model. It allows the dynamic analysis of the actuator system without resort to the repetitive finite element modeling work. Even though the dynamic characteristics of the system are affected somewhat by the structural modification and the change of the dynamic properties, we can use the modified size and material properties of the actuator system in the mathematical model to some extent. In this study, we express the mathematical model of the simplified rectangular plate first and then proceed to the actual hard disk drive actuator system.

  • PDF

Structural Performance Evaluation of End-plate Connections According to Constructional Quality in P.E.B System (P.E.B 시스템에서 시공상태에 따른 엔드플레이트 접합부의 구조성능평가)

  • Lee, Eun-Taik
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.461-468
    • /
    • 2012
  • P.E.B (Pre-Engineering Building) system means an economical system, which designs and uses optimal section proportion of tapered members according to the magnitude of bending moment. However, it is hard to adjust the friction type bolted joint in the joint of tapered member in the P.E.B system. End-plate connection is mainly used in this system due to that difficulty. Because P.E.B system has end-plate vertical defacts by heat welding deformation, a gap between end-plates and rafter or rib can be observed. In this study, an examination of construction stability was throughly performed and analyzed by the investigation of permissible internal force of bolts in end-plate connections under the bending moment using the end-plate's initial connection-defect (gap).

Comparison of Signal Powers Generated with Metal Hammer Plate and Plastic Hammer Plate (금속 및 플라스틱 재질의 해머 타격판에 의해 발생된 신호의 파워 비교)

  • Kim, Jin-Hoo;Lee, Young-Hyun
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.4
    • /
    • pp.282-288
    • /
    • 2011
  • One of the most challenging issues facing shallow seismic survey is how to generate large amplitude of high frequency signal with small seismic sources. We tested the performance of the most commonly used shallow seismic source, hammer, with four plates: PE, nylon, aluminum, and steel plates. We compared their signal powers in terms of impulsive forces, accelerations, and ground vibration velocities caused by hammer impacts. According to a previous work, hammer blowing to an aluminum plate would generate the largest amplitude among four combinations. However, it was found in this experimental research that aluminum plate delivers seismic wave energy to the ground less than that generated with steel or PE plate. Even though the amplitude is relatively small, plastic plates could provide seismic pulses of 180 ~ 200 Hz in the bandwidth, and it seems to be very hard to generate seismic energy over the frequency of 250 Hz.

A study on structural improvement in multi-cavity mold for ham can lids (햄 뚜껑 금형의 다수 캐비티 금형구조 개선에 관한 연구)

  • Lee, Eun-jong;Choi, Kye-kwang;Kim, Sei-hwan
    • Design & Manufacturing
    • /
    • v.7 no.1
    • /
    • pp.40-44
    • /
    • 2013
  • My company develops, manufactures injection mold and produces thin-walled cosmetics and food containers. Without high quality and low production cost, it is hard to compete in the market. To be competitive, a company has to utilize mold with as many cavities as possible to lower manufacturing cost. Eject plate abrasion and deformation cut down mold lifespan, troubles during injection lower productivity and foreign substances in molds cause abrasion. This study focuses on how to improve mold life and productivity, and to slow down mold abrasion.

  • PDF

Strength Evaluation for Cap Plate on the Node Connection in Circular Steel Tube Diagrid System

  • Lee, Seong-Hui;Kim, Jin-Ho;Choi, Sung-Mo
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.1
    • /
    • pp.21-28
    • /
    • 2012
  • Diagrid system has been in the spotlight for its superiority in terms of the resistance to lateral force when applied to skyscrapers. In diagrid system, most of columns can be eliminated because vertical loads (gravity loads) and horizontal loads (lateral loads) are delivered simultaneously thanks to the triangular shape of diagrid. However, lack of studies on connection shape and node connection details makes it hard to employ the system to the buildings. In this study, the structural safety of the node connections in circular steel tube diagrid system which has been considered in the Cyclone Tower in Korea (Seven stories below and fifty-one above the ground) was evaluated using the 4 full-scale specimens. The parameters are the extended length (20 mm, 40 mm & 60 mm), thickness (40 mm & 50 mm).