• Title/Summary/Keyword: Hard failure

Search Result 234, Processing Time 0.023 seconds

Characterization of the brittleness of hard rock at different temperatures using uniaxial compression tests

  • Chen, Guoqing;Li, Tianbin;Wang, Wei;Guo, Fan;Yin, Hongyu
    • Geomechanics and Engineering
    • /
    • v.13 no.1
    • /
    • pp.63-77
    • /
    • 2017
  • The failure mechanism of a deep hard rock tunnel under high geostress and high geothermalactivity is extremely complex. Uniaxial compression tests of granite at different temperatures were conducted. The complete stress-strain curves, mechanical parameters and macroscopic failure types of the rock were analyzed in detail. The brittleness index, which represents the possibility of a severe brittleness hazard, is proposed in this paperby comparing the peak stress and the expansion stress. The results show that the temperature range from 20 to $60^{\circ}C$ is able to aggravate the brittle failure of hard rock based on the brittleness index. The closure of internal micro cracks by thermal stress can improve the strength of hard rock and the storage capacity of elastic strain energy. The failure mode ofthe samples changes from shear failure to tensile failure as the temperature increases. In conclusion, the brittle failure mechanism of hard rock under the action of thermal coupling is revealed, and the analysis result offers significant guidance for deep buried tunnels at high temperatures and under high geostress.

Incompatible deformation and damage evolution of mixed strata specimens containing a circular hole

  • Yang, Shuo;Li, Yuanhai;Chen, Miao;Liu, Jinshan
    • Geomechanics and Engineering
    • /
    • v.20 no.5
    • /
    • pp.461-474
    • /
    • 2020
  • Analysing the incompatible deformation and damage evolution around the tunnels in mixed strata is significant for evaluating the tunnel stability, as well as the interaction between the support system and the surrounding rock mass. To investigate this issue, confined compression tests were conducted on upper-soft and lower-hard strata specimens containing a circular hole using a rock testing system, the physical mechanical properties were then investigated. Then, the incompatible deformation and failure modes of the specimens were analysed based on the digital speckle correlation method (DSCM) and Acoustic Emission (AE) data. Finally, numerical simulations were conducted to explore the damage evolution of the mixed strata. The results indicate that at low inclination angles, the deformation and v-shaped notches inside the hole are controlled by the structure plane. Progressive spalling failure occurs at the sidewalls along the structure plane in soft rock. But the transmission of the loading force between the soft rock and hard rock are different in local. At high inclination angles, v-shaped notches are approximately perpendicular to the structure plane, and the soft and hard rock bear common loads. Incompatible deformation between the soft rock and hard rock controls the failure process. At inclination angles of 0°, 30° and 90°, incompatible deformations are closely related to rock damage. At 60°, incompatible deformations and rock damage are discordant due that the soft rock and hard rock alternately bears the major loads during the failure process. The failure trend and modes of the numerical results agree very well with those observed in the experimental results. As the inclination angles increase, the proportion of the shear or tensile damage exhibits a nonlinear increase or decrease, suggesting that the inclination angle of mixed strata may promote shear damage and restrain tensile damage.

Stiction and AE Characteristics of Hard Disk Drive under Various Environmental Conditions (환경 조건에 따른 하드디스크의 Stiction 및 AE 특성)

  • 박용식;성인하;김대은
    • Tribology and Lubricants
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • Hard disk drives operate in various environmental conditions. Thus, it is necessary to assess the reliability of the head/disk interface under these conditions. In this work, stiction and acoustic emission signals were investigated under different temperature, humidity, and ambient pressure conditions. Also, track average amplitude was observed for disk failure in N$_2$environment. It is shown that failure of the head/disk interface occurs more readily at high temperature and low ambient pressure conditions.

Checkpoint Placement for Multiple Real-time Periodic Tasks with Hard Deadlines (하드 데드라인을 가지는 다중 실시간 주기적 태스크에서의 체크포인팅 기법)

  • Kwak, Seong-Woo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.8
    • /
    • pp.594-601
    • /
    • 2004
  • We analyze checkpoint strategy for multiple real-time periodic tasks with hard deadlines. Real-time tasks usually have deadlines associated with them. For multiple real-time tasks, checkpoint strategy considering deadlines of all tasks is very difficult to derive. We analyze the problem of checkpoint placement for such multiple periodic tasks. In our strategy, the interval between checkpoints is determined for each task considering its deadline. An approximated failure probability over a specified interval is derived. Then the number of checkpoints for each task is selected to minimize the approximated failure probability. To show the usefulness of our strategy, error bound between the exact and the approximated failure probability is estimated, which is revealed to be quite small.

The Study on Estimating Life Cycle of 2.5 Inch Hard disk base on PC using enviroment (PC 사용 환경에 기반한 2.5 인치 하드 디스크의 수명주기 예측에 대한 연구)

  • Cho, Euy-Hyun;Park, Jeong-Kyu;Lee, Min-Woo;Kwon, Soon-Mu
    • Journal of Digital Contents Society
    • /
    • v.15 no.2
    • /
    • pp.301-308
    • /
    • 2014
  • The mass storage of data and the importance of storage capacity lately has emerged. In this paper, we suggest the new method which estimate life cycle from acceleration life test about 2.5 inch hard disk driver as mass storage, which minimize the difference between real market annual failure rate and estimated failure rate. we obtain market transfer capacity per hours from returned 2.5inch hard disk drives about 309 numbers and accelerating transfer capacity per hours from acceleration life test. we calculate acceleration factor about duty cycle and estimate annual failure rate from failure rate and acceleration factors: temperature acceleration factor, duty cycle acceleration factor, the transfer capacity per hour represent the 93.4 % of user is 5.8 GB/hour, the transfer capacity per hour from acceleration life test is 81.4 GB/hour. the acceleration factor of duty cycle is 14.1. annual failure rate is stabilized at market one year after, annual failure rate is between 0.3 and 0.378. estimated annual failure rate is 0.4, so it is matched at 75~94 % between estimate annual failure rate and market annual failure rate. This study influence the estimate method of annual failure rate by the result of acceleration life cycle of manufacture.

The Data Transmission of Image Storage System of PACS (PACS내 영상저장 장치의 데이터 전송)

  • Cho, EuyHyun;Park, Jeongkyu
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.785-791
    • /
    • 2018
  • Recently, Disk array is widely used as a long term storage device in PACS, but reliability is not enough in relation to annual failure rate of disk. Between October 2016 and February 2017, we scanned the serial port of the hard disk while reading or storing medical images on a PACS reader. The data rate was calculated from the data stored in HDD 99ea that were used in the PCAS image storage device and in HDD 101ea that were used in the Personal Computer. When a CT image was read from a PACS reader, Reading was 87.8% and Writing was 12.2% in units of several tens of megabytes or less. When the CT image was stored in the PACS reader, Reading was 11.4% and Writing was 88.6% in units of several tens of megabytes or less. While reading the excel file on the personal computer, Reading was 75% and Writing was 25% in less than 3 MB, and In the process of storing the excel file on the personal computer, Reading was carried out by 38% and Writing was carreid out 62% in the units of 3 MB or less. The transfer rate of the hard disk used in the PACS image storage device was 10 GB/h, and the transfer rate per hour of the hard disk of the personal computer was 5 GB / h. Annual failure rate of hard disk of image storage system is 0.97 ~ 1.13%, Annual failure rate of Hard Disk of personal computer is 0.97 ~ 1.13%. the higher transfer rate is, the higher annual failure rate is. These results will be used as a basis for predicting the life expectancy of the hard disk and the annual failure rate.

Effect of Particulate Contamination on the Friction and Wear of Head-Disk Interface with Picoslider (오염입자가 Picoslider의 헤드-디스크 인테페이스 마찰 마모에 미치는 영향)

  • ;Bharat Bhushan
    • Tribology and Lubricants
    • /
    • v.16 no.5
    • /
    • pp.395-402
    • /
    • 2000
  • The effect of particulate contamination on friction and wear between a negative-pressure picoslider and a laser-textured disk was studied. Particles of different concentrations, materials and sizes were injected to the head-disk interface (HDI), consisting of disks with various textures, at the same speed. In a contaminated environment, durability of head-disk interface gradually decreased as the particle concentration increased. Large particles caused HDI failure early and resulted in an extensive damage to the slider and disk surfaces. Hard particles also caused HDI failure earlier and damages more extensive than soft ones. Based on the test results, mechanisms of HDI failure with picoslider were presented.

THE EFFECT OF DENTURE CLEANSERS ON THE BOND STRENGTH AND THE SURFACE HARDNESS OF RELINE RESIN TO DENTURE BASE RESIN (의치 세정제가 의치상 레진과 이장용 레진의 결합강도와 표면경도에 미치는 영향)

  • Kim Kyea-Soon;Jeong Hoe-Yeol;Kim Yu-Lee;Cho Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.493-502
    • /
    • 2003
  • Statement of problem : Removable partial denture and complete denture often require denture base relines to improve the fittness against tissue-bearing mucosa because of the gradual change in edentulous ridge contour and resorption of underlyng bony structure. Self-curing hard reline resins offers the immediate and relatively inexpensive means to be recondition the surface of denture base directly However weak bond between denture base resin and reline material can harbor bacteria, promote staining, or result in complete separation of the two materials. Purpose : The purpose of this study was to evaluate the effect of denture cleansers on bond strength and surface hardness of reline resin to denture base resin Denture base resin beams($60.0{\times}15.0{\times}3.0mm$) were made with Lucitone 199. Material and methods : 10mm section was removed from the center of each specimen. The samples were replaced in the molds and the space of l0mm sections were packed with Tokuso Rebase reline material. The specimens were immersed in denture cleansers (Polident, Cleadent) and were evaluated after 1 week, 2 weeks, and 4 weeks. The bond strength and surface hardness of self-curing hard reline materials to heat-curing denture base resin were measured using an UTM (universal testing machine). Results and conclusion : 1) There was no significant difference of usage, kind, and denture cleaner by application time on the bonding strength of self-curing hard reline resin to denture base resin. 2) There was no significant difference of usage, kind, and denture cleaner by application time on the surface hardness, but the surface hardness showed decreasing tendency, as the time of immersion was extended. 3) The failure modes of the specimens was initially adhesive failure and finally cohesive failure of self-curing hard reline resin.

The Reinforcement Method and Stability Analysis of Cut Slopes (절토사면의 안정해석과 보강방법)

  • 지인택;이달원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.1
    • /
    • pp.112-121
    • /
    • 1997
  • The aim of this study was to analyze the slope stability relating to the failure of cut slopes and the characteristics of stress-strain relations obtained by limit equilibrium method, finite element method, and stereographic projection method for the reinforced cut slopes. The following conclusions were made : 1.To use stereographic projection method led to little possibility to take the toppling and wedge failure while to use the other methods led to the failure. It was recommended to reduce the slope inclination from 1:1 to 1: 1.5~1 :1.8 and adopt coir mesh method to protect the slope surface. position with the horizontal displacement after final excavation moved to the excavation base. The maximum shear strain values concentrated at the excavation base indicated the possibility to induce the local failure. 3. It was recommended that the slope inclination for blast rock with the slope height larger than l0m was 1: 0.5, 1:1, and 1: 1~1 :1.5 for hard rocks, soft and ordinary rocks, and ripping and soils, respectively. 4. Berm width criteria for blast rock with the slope height larger than l0m were recommended as follow : 2~3m per 20m slope height for hard rocks, 1 ~2m per l0m slope height for soft and ordinary rocks, 1 ~ l.5m per 5m slope height for ripping and soils.

  • PDF

Cochlear Implant Failure in the Pediatric Population

  • Ozer, Fulya;Yavuz, Haluk;Yilmaz, Ismail;Ozluoglu, Levent N.
    • Journal of Audiology & Otology
    • /
    • v.25 no.4
    • /
    • pp.217-223
    • /
    • 2021
  • Background and Objectives: In cochlear implant (CI) surgery, the results and causes of revision and reimplantation may guide surgeons in establishing surgical protocols for revision surgery with safe audiological outcomes. The aim of this study was to review our experience in terms of etiology, surgical strategy, and hearing outcomes in pediatric patients who underwent CI removal and reimplantation. Subjects and Methods: All patients received implants of the same brand. Pre and postoperative Categories of Auditory Performance score and aided free-field pure tone audiometry thresholds were noted. In vivo integrity tests were performed for each patient and the results of ex vivo tests of each implant were obtained from manufacturer. Results: A total of 149 CIs were placed in 121 patients aged <18 years. The revision rate in children was 6.7% (10/121 children). Six patients had a history of head injury leading to a hard failure. The causes of reimplantation in others were soft failure (n=1), electrode migration (n=1), infection (n=1), and other (n=1). All patients showed better or similar postreimplantation audiological performance compared with pre-reimplantation results. Conclusions: It is very important to provide a safe school and home environment and educate the family for reducing reimplantation due to trauma. Especially for active children, psychiatric consultation should be continued postoperatively.