• Title/Summary/Keyword: Hard X-ray

Search Result 206, Processing Time 0.04 seconds

The 105-month Swift-BAT all-sky hard X-ray survey

  • Oh, Kyuseok;Koss, Michael;Markwardt, Craig B.;Schawinski, Kevin;Baumgartner, Wayne H.;Barthelmy, Scott D.;Cenko, Bradley;Gehrels, Neil;Mushotzky, Richard;Petulante, Abigail;Ricci, Claudio;Lien, Amy;Trakhtenbrot, Benny
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.36.3-37
    • /
    • 2018
  • We present a new catalog of hard X-ray sources detected in the first 105 months of observations with the Burst Alert Telescope (BAT) on board the Neil Gehrels Swift observatory. The 105 month Swift-BAT survey is a uniform hard X-ray all-sky survey performed in the 14-195 keV band. The Swift-BAT 105 month catalog provides 1632 (422 new detections) hard X-ray sources in the 14 - 195 keV band above the 4.8 sigma significance level. Adding to the previously known hard X-ray sources, 34% (144/422) of the new detections are identified as Seyfert AGN in nearby galaxies (z < 0.2). The majority of the remaining identified sources are X-ray binaries (7%, 31) and blazars/BL Lac objects (10%, 43). As part of this new edition of the Swift-BAT catalog, we release eight-channel spectra and monthly sampled light curves for each object in the online journal and at the Swift-BAT 105 month Web site.

  • PDF

Synchrotron Radiation Imaging of Breast Tissue Using a Phase-contrast Hard X-ray Microscope (경 엑스선 위상차 현미경을 이용한 유방 조직의 방사광 영상)

  • Jeong, Young-Ju;Bong, Jin-Gu;Park, Sung-Hwan
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.117-123
    • /
    • 2011
  • Synchrotron radiation (SR) imaging enables us to observe internal structures of biologic samples without staining. In this study, we obtained X-ray microscopic images of human breast tissues with 11.1 KeV hard X-ray microscope of the Pohang light source and used zone plates and phase-contrast technique to get high resolution X-ray images. Hard X-ray microscopic images of fibrocystic change and breast cancer tissues with a spatial resolution of 60 nm were obtained and from these images, we could observe the micro-structures of human breast tissue. Also we analyzed and compared these images, which revealed distinct features of each condition. In conclusion, SR imaging with phase-contrast hard X-ray microscope for medical application, especially in breast disease can give some useful information for clinical research.

Anti-correlated hard and soft X-ray lags in the Z source GX 5-1

  • Sriram, K.;Choi, C.S.;Rao, A.R.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.149.2-149.2
    • /
    • 2011
  • We performed the cross-correlation analysis on energy-dependent light curves of the Z-type source GX 5-1. We observed X-ray delays of a few hundred seconds between hard (16-30 keV) and soft (2-5 keV) X-ray light curves. During these phenomena, the centroid frequency of horizontal branch oscillation (HBO) was found to shift to lower or higher frequency indicating towards the dynamical movement of a Compton cloud or an inner disk front. Both eastern and western approaches were used to unfold the X-ray continuum and systematic changes were observed in soft and hard X-ray spectral components. Simultaneous energy spectral and power density spectral study shows that the production of HBOs is closely related to the Comptonizing region rather than the accretion disk. We discuss the results in the context of re-condensation of coronal material in the inner accretion disk region.

  • PDF

HARD X-RAY PULSATIONS IN GX 1+4

  • AGRAWAL P. C.;PAUL B.;RAO A. R.;CHANDA R. K. MAN
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.219-221
    • /
    • 1996
  • The x-ray pulsar GX 1+4 was observed by us in four balloon- borne experiments carried out from Hyderabad, India during 1991-1995 period with a hard x-ray telescope. The x-ray telescope consists of two collimated large area xenon-filled proportional counters with an effective area of $2400 cm^2$, a field of view of $5^{\circ}{\times}5^{\circ}$ and sensitive in the energy band of 20 - 100 keV. The pulsar was detected in bright state in two of the four experiments and x-ray pulsations with 120 second period were detected clearly. Pulsation period, rate of change of period with time, pulse fraction, pulse profile and energy spectra of the source were determined from these studies. During March 1995 observation, the x-ray pulse of GX 1+4 was found to be double-peaked compared to a single-peak pulse profile detected in December 1993. Details of these results are presented and their interpretation discussed in terms of the current accretion models of x-ray binaries.

  • PDF

Design and Fabrication of Hard X-ray Zone Plate (경 엑스선 존 플레이트(Zone Plate) 설계 및 제작)

  • Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.27-31
    • /
    • 2010
  • Spatial resolution is determined by the performance of x-ray optics used in the x-ray imaging system. A zone plate was designed for obtaining a high spatial resolution image at x-ray energy of 8.5keV. A spatial resolution of 80 nm was estimated by the ray tracing when an x-ray tube of tungsten targe was used instead of synchrotron radiation. The designed zone plate of outermost zone width of 40nm was successfully fabricated by the electron-beam lithography.

Radio and Hard X-ray Study of the 2011 August 09 Flare

  • Hwangbo, Jung-Eun;Bong, Su-Chan;Lee, Jeongwoo;Lee, Dae-Young;Park, Seong-Hong;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.65.1-65.1
    • /
    • 2013
  • The 2011 August 09 Flare is one of the largest X-ray flares of Sunspot Cycle 24 to attract a lot of attention for its various activities detected in coronal images. In this study we concern ourselves mostly on information of high energy electrons produced during this flare provided by hard X ray data from the Reuven Ramaty High-Energy Solar Spectroscopic Imager (RHESSI) and radio data from the Korean Solar Radio Burst Locator (KSRBL) and Ondrejov. EUV images obtained by the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamic Observatory are used to provide the context of magnetic reconnection. In our results, (1) HXR spectra have a rich spectral morphology. Initially it could be fit by one thermal component (T~30MK) and one single power law nonthermal spectrum, but later a better fit could be made by introducing an additional thermal component (T~55 MK). (2) Time delays between the KSRBL burst and the RHESSI hard X-ray emission were found which are more obvious at low frequencies and insignificant at high frequencies. (3) The HXR source lies in the core of the quadrupolar active region. In our interpretation based on AIA 94 A images, the outer part of the active region erupted to be blown out, leaving the intense hard X-ray emission concentrated in the core. We relate the appearance of the second thermal component to the evolution of the AIA 171 and 94 A images. The time delays of microwave peaks to HXR peaks are interpreted as indicating presence of trapped electrons in larger closed magnetic loops. With these result we conclude that the hard X ray and microwaves are due to impulsive acceleration in the low and high heights and a sigmoidal reconnection scenario.

  • PDF

The Compound Refractive Lens for Hard X-ray Focusing

  • Choi, J.;Jung, J.;Park, S.;Kwon, T.
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.76-81
    • /
    • 2007
  • The compound refractive X-ray lens (CRL) for focusing hard X-rays is investigated to determine the parameters such as the focal length, the focal spot size, and spatial distribution at the focal spot using a simple theoretical calculations and CRLs fabricated by the self-assembly method. The number of individual compound lenses are defined for the given focal length of 1 m. The X-ray energy of 1 to 40 keV is used in the calculations. The CRL for focusing hard X-rays which generated from the X-ray tube is fabricated by nanoparticle-polymer composite in the form of circular concaves. The self-assembly method is applied to form the nanoaluminum-poly (methly meth-acrylate) composite and carbon-polymer composite CRL lenses. Aluminum nanoparticles of 100 nm and carbon microparticles are diffused in the polymer solution then the high gravity up to 6000G is applied in it to form the concave lens shape. X-ray energy at 8 keV is used for characterization of the composite CRLs. The FWHM of intensity for the fabricated nanoaluminium composite CRL system, N=10 is measured as 1.8 mm, which would give about $70{\mu}m$ in FWHM at 1 m of the focal length.

Analysis of Rolling Contact Fatigue of Ball Bearing with Various Hardness by X-ray Diffraction (BEARING소재 경도에 따른 구름접촉피로의 X선적 해석)

  • 이한영
    • Tribology and Lubricants
    • /
    • v.17 no.3
    • /
    • pp.209-215
    • /
    • 2001
  • In view of the effects of the hardness of material on fatigue, rolling contact fatigue process in hard metals seems to differ from it in soft metals. This paper has been aimed to compare the rolling contact fatigue process according to the hardness of materials. Rolling contact fatigue tests using the ball bearings assembled with the inner race of four different hardness have been carried out. In addition, residual stress and half-value breadth on/below the inner raceway during individual rolling contact fatigue have been measured by X-ray diffraction. The results of this study showed that the change of residual stress and half-value breadth during the rolling contact fatigue on race way in hard metals is the same as in soft metals. However, plastic deformation by rolling contact in hard metals is in microscopic scale but only for soft metals in macroscopic scale.