• Title/Summary/Keyword: Hanger

Search Result 127, Processing Time 0.028 seconds

Finite Element Analysis for Application of Torsion-free Brake Shoe Holder Hanger for the Bogie of Railway Freight Car (화차대차용 비틀림 흡수구조형 제륜자 홀더행거의 적용을 위한 유한요소해석)

  • Jeon Eung-Sik;Ham Young-Sam
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.36-41
    • /
    • 2003
  • Among welded structure bogies in use for high speed freight car, a part of bogies manufactured in 1999 and 2000 have found problems that failure occurs in its end beam. In case of a freight car a difference of weight between empty and loading conditions are worse than in case of a passenger car. Moreover its brake system is tread brake without second suspension system. A failure of end beam is supposed to be due to loading by brake rather than vertical loading by freight. This failure can make brake system useless and may be a cause of derailment in the worst case. In this study, we have proposed a simple torsion-free brake shoe holder hanger to remove torsion of hanger bracket which is supposed to be one of causes of failure and performed finite element analyses for making trial manufactures and its application.

  • PDF

Analysis on piotical changes in Hanger Design: From 1850 to 2003 (시대적 흐름에 따른 옷걸이 변화에 관한 연구 -1850년경부터 2003년까지 -)

  • 조숙경
    • Journal of the Korea Furniture Society
    • /
    • v.14 no.2
    • /
    • pp.87-96
    • /
    • 2003
  • This study explores aesthetics and materials used in domestic and international hanger designs from 1850 to 2003. At the second half of the nineteenth century, most hangers were handmade and made of wood and metal. At the first half of the twentieth century, such diverse materials as paper, plastics, and leather began to use other than such typical materials as wood and metal at the previous decades. However, from the second half of the twentieth century the use of different types of plastics led to artistic abnormal shapes within typical triangular types. Moreover, this study also examines hangers by its functions: primary, portable, and multi-functional types.

  • PDF

Evaluation on Shear Behaviors of the Dapped Ends of Domestic Composite Double Tee Slabs under the Short-Term Loading (단기하중하의 국내 합성 더블티 슬래브 댑단부 전단거동 평가)

  • 유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.774-781
    • /
    • 2002
  • Shear behaviors of eight dapped ends of four full-scale domestic single-tee slabs were evaluated. The dapped ends with 10cm topping concrete were designed based on live load requirements for the domestic parking lot of m 500kgf/㎡ and for the large market of 1,200 kgf/㎡. All specimens were designed by the ACI 318-99 design. The variations of the experiment were the shape of hanger reinforcements as followings: 1) general PCI design method(currently used in domestic), 2) 90 degree bent-up, 3) 60 degree bent-up. All experiments were conducted with 1.2 m shear span. The results obtained in this study were 1) all specimens fully complied with the shear strength requirements as specified by ACI 318-99 except for one strand bond slip specimen, 2)a specimen with the 60 degree bent up hanger reinforcing detail showed the best shear behaviors under full service and ultimate load, and 3)a specimen with the 90 degree bent up hanger reinforcing detail resulted in the worst shear behaviors.

Estimating Tensile Force of Hangers in Suspension Bridges Using Frequency Based SI Technique : III. Experimental Verification (진동기반의 SI 기법을 이용한 현수교 행어의 장력 추정 : III. 실험적 검증)

  • Jang, Han Teak;Kim, Byeong Hwa;Park, Taehyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.215-222
    • /
    • 2008
  • This paper introduces an experimental verification of a tension estimation method based on system identification approach for a double hanger system on a suspension bridge. A laboratory model of such double hanger system has been made for this study. Total nine cases of the vibration tests have been conducted with respect to three levels of applied tension and three cases of the location of clamp. For a set of the collected acceleration response data, modal analysis has been followed in order to extract the natural frequencies and mode shapes of the selected cable systems. For the extracted modal parameters, the existing tension estimation methods based on the string theory and axially loaded beam theory have been firstly applied to estimate the tensile force on the double hanger cable system. Next, the tensile force on cables has been estimated by the system identification approach. It is seen that the errors in the tension estimation using the frequency-based system identification technique are about 3% for all cases while the estimation error using the existing method is up to 53.1%.

Aerodynamic Stability Assessment of PWS and CFRC Hanger Ropes for Suspension Bridge by Experiments (현수교 PWS 및 CFRC 행어로프의 내풍안정성 실험 평가)

  • Park, Hyung-Ghee;Kang, Seon-Jin
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.21-30
    • /
    • 2008
  • In this study, to evaluate the aerodynamic stability of suspension bridge hanger ropes, the wind tunnel tests are carried out. It is found that the vortex induced vibration is detected only in single PE-coated PWS cable case. And the wake galloping is occurred in twin cables spaced $3\sim6$ cable diameters of cable center to center when the incidence angle of wind is only zero degree. In case of other incidence angles of wind except zero degree, the wake galloping or the wake flutter are showed in twin cables even outside range of the bounds of $3\sim6$ cable diameters. CFRC cable shows very stable for the twin cables regardless of the distance between two cables, and also for various incidence angles of wind. Thus the characteristic of CFRC rope overwhelms one of PWS cable in aerodynamic stability.

The Design of Laundry System for Low Power and Smart Management

  • Van, Nghia Truong;Kim, Min-Chul;Jung, Kyung-Kwon;Son, Dong-Sul;Lee, Hyun-Kwan;Eom, Ki-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.274-277
    • /
    • 2012
  • In this paper, we proposes the design of laundry system for low power and smart management. The low power system configures the network with the RF communication module that turn on/off periodically, power consumption less than operating the module all the time without it toggles. The smart management is RFID Laundry Management System (LMS), in order to provide high services, low operation costs and better monitoring. The proposed system consists of RFID tag, wireless RFID hanger and MFC software. To compare with other existing RFID system, our system was developed as a web application. Therefore, customer can check their cloth status through web page or smartphone devices. RFID reader was designed on hanger to make our system enables reliable running effectively. Some results on the performance of an implementation are presented.

  • PDF

An Evaluation for Structural Performance of Suspension Bridge by using the Natural Frequency of Hanger Member (행거의 고유진동수를 이용한 현수교의 구조적 성능 평가)

  • Wu, Sang Ik;Kim, Kyoung Nam;Lee, Seong Haeng;Jung, Kyoung Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.285-293
    • /
    • 2004
  • As a special infrastructure, it is important that the suspension bridges which were designed by using the cable are carefully maintained and safely inspected after their construction, more than what is done in other cases of bridge structures. However, the structural analysis for their design and maintenance has considered only the simplified geometric shape of the structure. Particularly, it is not easy to make the modeling analyze the bridge structure including detailed steel deck plates. In this paper, we evaluated the structural behaviors and performances of the completed earth-anchored suspension bridge that was in a completed state through both the tension of hanger member and their computational analysis. We considered the frame system and the detailed steel deck plates that were especially added into the modeling to take more precision analysis about it. We also applied hanger tensions converted by the natural frequency and the natural frequency of the bridge when in normal vibration. Results of the vehicle loading test were used in the analysis. We compared the results by using our modeling with the result of the loading test and the hanger tension. Our prediction on the behavior of the structure emulates the behavior of the real structure. In applying the data measured by the typhoon "Maemi" which arrived in-land last year, we confirmed our analysis model for the possibility of applying effectively into the preliminary design and maintenance plan.

Application of Vision-based Measurement System for Estimation of Dynamic Characteristics on Hanger Cables (행어케이블의 동특성 추정을 위한 영상계측시스템 적용)

  • Kim, Sung-Wan;Kim, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1A
    • /
    • pp.1-10
    • /
    • 2012
  • Along with the development of coasts, islands and mountains, the demand of long-span bridges increases which, in turn, brings forth the construction of cable-supported bridges like suspension and cable-stayed bridges. There are various types of statically indeterminate structures widely applied that supported the main girder with stay cables, main cables, hanger cables with aesthetic structural appearance. As to the cable-supported bridges, the health monitoring of a bridge can be identified by measuring tension force on cable repeatedly. The tension force on cable is measured either by direct measurement of stress of cable using load cell or hydraulic jack, or by vibration method estimating tension force using cable shape and measured dynamic characteristics. In this study, a method to estimate dynamic characteristics of hanger cables by using a digital image processing is suggested. Digital images are acquired by a portable digital camcorder, which is the sensor to remotely measure dynamic responses considering convenient and economical aspects for use. A digital image correlation(DIC) technique is applied for digital image processing, and an image transform function(ITF) to correct the geometric distortion induced from the deformed images is used to estimate subpixel. And, the correction of motion of vision-based measurement system using a fixed object in an image without installing additional sensor can be enhanced the resolution of dynamic responses and modal frequencies of hanger cables.

A Numerical Study on Dynamic Characteristics of a Catenary

  • Kim, Jung-Soo;Kim, Woonkyung M.;Kim, Jeung-Tae;Lee, Jae-Won
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.860-869
    • /
    • 2003
  • Dynamic characteristics of a catenary that supplies electrical power to high-speed railway is investigated. The catenary is a slender structure composed of repeating spans. Each span is in turn composed of the contact and messenger wires connected by the hangers in regular intervals. A finite element based dynamic model is developed, and numerical simulations are performed to determine the dynamic characteristics of the catenary The influence of the structural parameters on the response characteristics is investigated. The structural parameters considered include tension on the contact and messenger wires, stiffness of the hangers, and the hanger and span spacing. The hanger characteristics are found to be the dominant factors that influence the overall dynamic characteristics of the catenary.

Sensitivity and vibration reduction of buffeting induced resonance of hangers

  • Zhang, Zhitian;Zhang, Weifeng
    • Wind and Structures
    • /
    • v.25 no.1
    • /
    • pp.39-61
    • /
    • 2017
  • Buffeting induced resonance (BIR) of hangers on long-suspension bridges is briefly reviewed, including mechanism and experimental verification. Taken the Xihoumen suspension bridge as a numerical example, sensitivities of the BIR of hangers to wind properties are investigated, including types of wind spectrum, turbulence intensity, and spacial coherence of wind fluctuations. Numerical simulations indicate that the BIR of hangers occur to both cases of different wind spectra, showing that it is insensitive to types of wind spectrum. On the other hand, it is found that the turbulence intensity affects buffeting of main cables almost in a linear manner, and so it does to the BIR of the hangers; however, the resonance factors, namely the ratio of the response of the hanger to that of the main cable, are little affected by the turbulence intensity. The spacial coherence of the wind fluctuations, although plays an important role on the buffeting responses of the main structure, has no substantial effects on the BIR of the hangers. Finally, replacement of steel strand with CFRP material has been verified as a very effective countermeasure against the BIR of hangers.