• Title/Summary/Keyword: Handpieces

Search Result 21, Processing Time 0.032 seconds

Numerical Analysis on Performance of Dental Air Turbine Handpiece for Various Reflection Angles of Turbine Rotor (터빈 로터 반사각에 따른 의료용 에어터빈 핸드피스의 성능에 관한 수치 해석)

  • Lee, Jeong-Ho;Lee, Sang-Do;Kim, Kui-Soon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.29-32
    • /
    • 2008
  • Dental high-speed air turbine handpieces have been used as a dental cutting tool in clinical dentistry for over 50 years, yet little study has been reported on their flow and performance analysis. Therefore it is necessary to investigate turbine for the performance improvements of an air turbine handpiece. This paper presents pressure on turbine rotor and flow analysis in air turbine handpiece using CFD (computational fluid dynamics). Characteristics on each flow and pressure for four various reflection angles of turbine rotor are presented, and then performance change is analyzed about air turbine handpieces by CFD results.

  • PDF

A SCANNING ELECTRON MICROSCOPIC STUDY OF CAVITY WALL (와동면(窩洞面)의 주사전자현미경적(走査電子顯微鏡的) 연구(硏究))

  • Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.11 no.1
    • /
    • pp.11-18
    • /
    • 1985
  • The purpose of this study was to observe the facial, lingual and gingival walls of the cavity walls with various kinds of cutting tools. Class II cavities were prepared in newly extracted sound humen mandibular 1st left premolars, and observed in Sanning electron microscope. Diamond point (#201) and Tungsten Carbide burs (#170L) were used in ultra high speed handpieces (rpm 200000), and Tungsten Carbide bur (#702) and Steel bur (#560) were used in conventional handpieces (rpm 6000). All cavities were prepared under water spray, except for some which were finished with a dry abrasive stone (#57). Some cavities were finished with chisels (#41, 42, 83). The following results were obtained. 1. The cavity walls prepared with Diamond point were rougher than the cavity walls with Carbide burs and Steel burs. 2. The chisels were produced the smoothest surface. 3. The cavity walls which were prepared with cutting blades rotated toward enamel surface from outside, were smoother than cavity walls which were prepared with cutting blades rotated toward outside from the enamel surface.

  • PDF

Effect of Noise Cancelling Devices on Dental Handpieces Using Ear Model (귀 모형을 이용한 치과 핸드피스에 대한 소음 저감 장치의 효과 분석)

  • Mo, Seunghan;Kang, Jungu;Kim, Ik-Hwan;Choi, Hyung-Jun;Song, Je Seon;Shin, Yooseok
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.62-69
    • /
    • 2020
  • This study intended to evaluate noise level of dental handpieces and the effects of noise cancelling devices. An ear model was designed to measure the level of the noise delivered to the inner ear during dental handpiece operation. The level of noise was measured in various conditions using the ear model and the portable noise meter. Noise level was measured again after applying of 4 different noise cancelling devices to the model ear. The noise level of dental handpieces was 82.5 - 84.4 dB. When 4 types of noise canceling devices were applied, the noise level reduced to 67.4 - 73.8 dB. All 4 devices had statistically significant effect in reducing the noise of the handpiece. Considering the intensity and exposure time, noise in dental clinics can cause hearing damage to dentists. For protection from the risk of occupational hearing damages, noise canceling devices can be recommended.

Comparison vibration characteristics of several wireless endodontic handpieces (여러 근관치료용 무선 핸드피스의 진동양상 비교)

  • Lee, Bo-Kyung;Lee, Yoon;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.2
    • /
    • pp.81-89
    • /
    • 2022
  • Purpose: Wireless endodontic handpieces (WEH) are widely used in dental clinics due to their convenience and portability. This study aimed to compare the vibration magnitudes and patterns generated by five WEH. Materials and Methods: Vibration acceleration of five WEH (X-Smart IQ, E connect S, Endo A Class, ENDOIT, and TRAUS ENDO) in the rotary and reciprocating motion was measured with accelerometer The average vibration acceleration was analyzed using the t-test, Welch's ANOVA test, and Dunnett T3 test at P < 0.05. Results: In all WEH, the average vibration acceleration in reciprocating motion was significantly higher than that in rotary motion (P < 0.001). In rotary motion, repeated vibration graphs of constant amplitude were obtained without sudden changes in the magnitude of vibration, and the average vibration acceleration value was high in the order of X Smart IQ, Endo A Class, ENDOIT, E Connect S, and TRAUS ENDO (P < 0.001), there was no statistically significant difference between X Smart IQ and Endo A Class. In reciprocating motion, a vibration graph was obtained in which large amplitude peaks appear at specific points within one cycle are repeated. The average vibration acceleration value was highest in the order of X Smart IQ, E Connect S, Endo A class, ENDOIT, and TRAUS ENDO (P < 0.001). Conclusion: Regardless of the type of WEH, greater vibration occurred in the reciprocating motion than in the rotary motion (P < 0.001). In the reciprocating motion, there was a difference in vibration for all handpieces (P < 0.001).

Design of Brushless DC Motor Speed Control System for Handpieces (핸드피스용 BLDC 모터 속도 제어시스템의 설계)

  • Kwak, Seong-Woo;Yang, Jung-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.6
    • /
    • pp.597-604
    • /
    • 2016
  • In this paper, we develope a speed control system of a BLDC motor for handpieces used in beauty applications. To reduce implementation cost, the control system utilizes hall sensors embedded in BLDC motors for speed estimation. The developed power module of a motor uses only 220V home voltage, so that the control system does not need any other power sources. An over-speed limit controller is also developed to slow down a motor when the speed goes up rapidly for a moment upon some heavy load is removed. The control system is designed to operate a handpiece with speed in the range of 5,000~30,000 RPM. Experiment results show the validity of the developed system, which maintains the speed of a motor steady even though a load is varied.

Subcutaneous Emphysema and Pneumomediastinum during Extraction of Maxillary Third Molar: A Case Report

  • Jung, Da-Woon;Yoon, Hyun-Joong;Lee, Sang-Hwa
    • Journal of Korean Dental Science
    • /
    • v.7 no.1
    • /
    • pp.25-30
    • /
    • 2014
  • Subcutaneous emphysema and pneumomediastinum is a relatively uncommon phenomenon. It may occur secondary to dental treatment using high-speed air turbine handpieces, especially after extraction of tooth. Subcutaneous emphysema is often limited only to the areas of head and neck, but also can involve deeper structures. Thorough examination and conservative treatment of these problems are essential in preventing life-threatening complications such as airway obstruction and mediastinitis. The subject of this report is a 57-year-old woman with subcutaneous emphysema and pneumomediastinum during the extraction of maxillary third molar using high-speed air turbine handpiece. If there isn't any appropriate measure, severe complications may occur. Therefore it is important to be well-informed of proper diagnosis and treatment. This article shall present a case report with literature review.

A NUMERICAL STUDY ON PERFORMANCE CHARACTERISTICS OF DENTURE HIGH-SPEED AIR TURBINE HANDPIECE (치기공용 에어터빈 핸드피스의 성능에 대한 수치해석적 연구)

  • Koh, D.H.;Song, D.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.271-276
    • /
    • 2010
  • High-speed air turbine handpieces have been used as a denture cutting tool in clinical dentistry for over 50 years. The denture high-speed air turbine handpiece is currently used as the main means of cutting tooth structure and restorative materials in a wide range of denture manufacturing. But little study has been reported on their performance analysis. This research would show the performance characteristics of denture air turbine handpiece by using CFD.

  • PDF

A Study on Bacterial Concentrations in Dental Offices (치과 진료실내의 세균오염도와 영향인자에 관한 연구)

  • Yun, Kyoung-Ok;Park, Hee-Jin;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.6
    • /
    • pp.469-476
    • /
    • 2014
  • Objectives: The purpose of this study was to identify the stains causing infections in dental clinics by analyzing bacterial contamination, as well as to suggest improvements for infection control in dental clinics. Methods: In this study, a questionnaire survey of 47 dental hospitals and clinics located in Gyeonggi-do and Incheon, South Korea was administered from June 2013 to September 2013 and used to investigate the practice rates of infection control by dental hygienists and to analyze the bacterial contamination levels in dental offices. Results: In the studied institutions, the bacterial contamination levels of water lines were $20.9{\times}10^3$ colony forming units (CFU)/mL for three-way syringes, $12.7{\times}10^3CFU/mL$ for high-speed handpieces and $9.8{\times}10^3CFU/mL$ for gargling water. The bacterial contamination levels of surfaces were $44.9{\times}10^3CFU/mL$ in cuspidors, higher than in unit chairs ($2.9{\times}10^3CFU/mL$) and light handles ($6.7{\times}10^3CFU/mL$). The mean bacterial cell count of water lines and surfaces was relatively high in all establishments founded 11 years ago or more, and the mean bacterial cell count of waterline handpieces was $6.27{\times}10^3CFU/mL$ in establishments founded between one and five years ago, $11.16{\times}10^3CFU/mL$ six to ten years ago and $20.04{\times}10^3CFU/mL$ 11 years ago or more, which suggests that earlier foundation is associated with higher bacterial contamination levels with a statistical difference (p<0.01). Similarly, the mean bacterial cell count of cuspidors using water from water lines was also $70.16{\times}10^3CFU/mL$ in at least 11-year-old establishments, statistically significantly higher among in one- to five-year-old ($4.61{\times}10^3CFU/mL$) and six- to ten-year-old clinics ($47.89{\times}10^3CFU/mL$) (p<0.05). Conclusion: This study may be utilized to improve the bacterial contamination levels in dental offices by controlling the characteristics and environmental factors of dental offices that affect the microbial contamination of waterlines and surfaces in such institutions.

Numerical Study on the Effect of Turbine Blade Shape on Performance Characteristics of a Dental Air Turbine Handpiece (터빈 블레이드 형상에 따른 의료용 에어터빈 핸드피스의 성능 특성에 관한 수치적 연구)

  • Lee, Jeong-Ho;Kim, Kui-Soon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.1
    • /
    • pp.34-42
    • /
    • 2009
  • High-speed air turbine handpieces have been used as a dental cutting tool in clinical dentistry for over 50 years, but little study has been reported on their performance analysis. Therefore, the effect of turbine blade shape on performance characteristics of dental air turbine handpiece were studied using CFD in this paper. Computations have been performed for five different positions of turbine blade by using frozen rotor method that is one of steady-state method. The characteristics of turbine blade for shapes and reflection angles were analyzed. As a result of the computation, torque is increased by increasing the reflection angle of turbine blade.