치과용 초음파 수술기의 절삭성능 평가를 위한 핸드피스 이송 시스템 구축 (Development of Handpiece Moving System (HMS) for Cutting Performance Evaluation of Dental Ultrasonic Surgery Unit)

  • 사민우;심해리;고태조;이종민;김종영
    • 한국정밀공학회지
    • /
    • 제33권5호
    • /
    • pp.377-383
    • /
    • 2016
  • Recently, research on bone fracture and osteoplasty using ultrasonic bone surgery unit has been ongoing in the fields of dentistry, plastic surgery, and otorhinolaryngology. However, detailed data evaluation with ultrasonic bone surgery unit has not been conducted to date. In this study, we developed handpiece moving system (HMS) for cutting performance evaluation. In the experimental setup of HMS, a handpiece was immobilized, and bone samples from cortical bone of bovine leg were prepared. Also, the experimental process was described in detail, and a basic experiment was carried out to evaluate the cutting performance. Future study is required on all experimental process conditions by HMS.

치과용 초음파 스케일러/수술기 통합 시스템의 스케일링 및 절삭 시 온도 변화에 관한 연구 (A Study on Temperature Changes during Bone Scaling and Cutting of Dental Ultrasonic Scaling/Surgery System)

  • 사민우;고태조;김종영
    • 한국기계가공학회지
    • /
    • 제19권2호
    • /
    • pp.1-8
    • /
    • 2020
  • While dental clinics still use the ultrasonic scaling/surgery tool for teeth scaling and cleaning the tool's use is expanding steadily to include treatment of damaged teeth and bone tissue. In this study, a handpiece moving system (HMS) was developed to evaluate bone scaling and cutting in the field of dentistry. The HMS, through a scaling test of bone using a scaler tip, it was able to identify surface damage. Additionally, a thermos-graphic camera was used to observe the temperature distribution that occurred during the bone scaling and cutting process. Consequently, we found that increasing the working load increased the amount of surface damage. Changes in temperature distribution occurred slowly and were maintained within safety bounds for 10 minutes. Going forward, we will compare the HMS performance on scaling and cutting with other devices.

골 절삭용 초음파 수술기의 실험적 평가에 관한 연구 (A Study about Experimental Evaluation of an Ultrasonic Surgery Unit for Bone-cutting)

  • 사민우;심해리;고태조;이종민;김종영
    • 한국기계가공학회지
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2016
  • In the dentistry field, an ultrasonic surgery unit is widely used in bone cutting and scaling to reduce operation time and minimize hemorrhage. The purpose of this study was to evaluate bone cutting and the effect of a specimen's temperature on the two-type ultrasonic surgery unit using a handpiece moving system(HMS). A HMS, which can cut the bone, was developed to perform the experimental procedure with precision of motion control. Bone specimens were prepared from a combination of epoxy-hardener and cortical bone of bovine leg. Through the bone-cutting experiment, the cutting depth was evaluated by not only scanning electron microscopy, but also Vernier calipers. Also, the temperature distribution was measured by a thermo-graphic camera. This study may be applied methodically in various experimental evaluations on a performance test by a HMS.